• Title/Summary/Keyword: Device to Device (D2D)

Search Result 1,734, Processing Time 0.036 seconds

Parallel Implementations of Digital Focus Indices Based on Minimax Search Using Multi-Core Processors

  • HyungTae, Kim;Duk-Yeon, Lee;Dongwoon, Choi;Jaehyeon, Kang;Dong-Wook, Lee
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.17 no.2
    • /
    • pp.542-558
    • /
    • 2023
  • A digital focus index (DFI) is a value used to determine image focus in scientific apparatus and smart devices. Automatic focus (AF) is an iterative and time-consuming procedure; however, its processing time can be reduced using a general processing unit (GPU) and a multi-core processor (MCP). In this study, parallel architectures of a minimax search algorithm (MSA) are applied to two DFIs: range algorithm (RA) and image contrast (CT). The DFIs are based on a histogram; however, the parallel computation of the histogram is conventionally inefficient because of the bank conflict in shared memory. The parallel architectures of RA and CT are constructed using parallel reduction for MSA, which is performed through parallel relative rating of the image pixel pairs and halved the rating in every step. The array size is then decreased to one, and the minimax is determined at the final reduction. Kernels for the architectures are constructed using open source software to make it relatively platform independent. The kernels are tested in a hexa-core PC and an embedded device using Lenna images of various sizes based on the resolutions of industrial cameras. The performance of the kernels for the DFIs was investigated in terms of processing speed and computational acceleration; the maximum acceleration was 32.6× in the best case and the MCP exhibited a higher performance.

A Study on Poly-Si TFT characteristics with string structure for 3D SONOS NAND Flash Memory Cell (3차원 SONOS 낸드 플래쉬 메모리 셀 적용을 위한 String 형태의 폴리실리콘 박막형 트랜지스터의 특성 연구)

  • Choi, Chae-Hyoung;Choi, Deuk-Sung;Jeong, Seung-Hyun
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.24 no.3
    • /
    • pp.7-11
    • /
    • 2017
  • In this paper, we have studied the characteristics of NAND Flash memory in SONOS Poly-Si Thin Film Transistor (Poly-Si TFT) device. Source/drain junctions(S/D) of cells were not implanted and selective transistors were located in the end of cells. We found the optimum conditions of process by means of the estimation for the doping concentration of channel and source/drain of selective transistor. As the doping concentration was increased, the channel current was increased and the characteristic of erase was improved. It was believed that the improvement of erase characteristic was probably due to the higher channel potential induced by GIDL current at the abrupt junction. In the condition of process optimum, program windows of threshold voltages were about 2.5V after writing and erasing. In addition, it was obtained that the swing value of poly Si TFT and the reliability by bake were enhanced by increasing process temperature of tunnel oxide.

Measurement of fMCG Signals using an Axial Type First-Order SQUID Gradiometer System (권선형 1차 미분계를 이용한 태아심자도 신호 측정)

  • Yu, K.K.;Kim, K.;Kang, C.S.;Kim, J.M.;Lee, Y.H.
    • Progress in Superconductivity
    • /
    • v.10 no.2
    • /
    • pp.139-143
    • /
    • 2009
  • We have fabricated a low-noise 61-channel axial-type first-order gradiometer system for measuring fetal magnetocardiography(MCG) signals. Superconducting quantum interference device(SQUID) sensor was based on double relaxation oscillation SQUID(DROS) for detecting biomagnetic signal, such as MCG, magnetoencphalogram(MEG) and fetal-MCG. The SQUID sensor detected axial component of fetal MCG signal. The pickup coil of SQUID sensor was wound with 120 ${\mu}m$ NbTi wire on bobbin(20 mm diameter) and was a first-order gradiometer to reject the environment noise. The sensors have low white noise of 3 $fT/Hz^{1/2}$ at 100 Hz on average. The fetal MCG was measured from $24{\sim}36$ weeks fetus in a magnetically shielded room(MSR) with shielding factor of 35 dB at 0.1 Hz and 80 dB at 100 Hz(comparatively mild shielding). The MCG signal contained maternal and fetal MCG. Fetal MCG could be distinguished relatively easily from maternal MCG by using independent component analysis(ICA) filter. In addition, we could observe T peak as well as QRS wave, respectively. It will be useful in detecting fetal cardiac diseases.

  • PDF

Design and Implementation of $\pi/4$ QPSK Satellite IP Modem Part ($\pi/4$ QPSK 위성 IP 모뎀부 설계 및 구현)

  • Kang, Jung-Mo;Jung, Jae-Wook;Kim, Myung-Sik;Oh, Woo-Jin
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.11 no.10
    • /
    • pp.1858-1865
    • /
    • 2007
  • In this paper, we introduce the design and implementation of satellite IP modem. The designed satellite IP modem shows the performance of 0.2% overhead, BER=10-5 when Eb/No=6dB, frequency offset of 8KHz, data rate up to 1536Kbps, $F_{if}=140MHz$. The designed system is verified through software simulation and then implemented with MPC86x communication processor, TMS320C6416 DSP, and Altera FPGA. Since each hardware unit is implemented in daughter board for modularity, we can reduce the development time and easily improve the performance with using better processor. Linux is used for embedded OS because it shows better performance in IP manipulation multitask processing, and hardware control through device driver. The implemented system is tested and verified with channel simulator. Since the proposed IP modem shows small size and light weight, that can be used anywhere with easy if you need IP environment.

Effect of Adding Fermented Organic Matter on the Performance of Benthic Microbial Fuel Cell (BMFC) (저생 미생물 연료전지(BMFC)의 성능에 미치는 발효 유기물 첨가 효과)

  • Lee, Mi-Hwa;Yang, Seol-Hwa;Kim, Young-Sook;Chu, Cheun-Ho;Park, Kwonpil
    • Korean Chemical Engineering Research
    • /
    • v.60 no.4
    • /
    • pp.486-491
    • /
    • 2022
  • A benthic microbial fuel cell (BMFC) is an eco-friendly energy conversion device that uses electricity generated by benthic microorganisms decomposing organic matter in the mud of the sea or lake. In this study, in order to understand how domestic wastewater flowing into tidal flats affects the performance of BMFC. BMFC performance was compared and reviewed by fermenting organic substances in food and mixing them with tidal flats. Performance of the BMFC was improved by 49% by adding fermented food rich in vitamins (B2, B6, B12, C, D, E) and soft flour. The maximum power density increased as the amount of fermented organic matter increased, and it was shown that the fermented organic matter fermented during 25~29 days was optimal for BMFC.

Development of SWIR 3D Lidar System with Low Optical Power Using 1 Channel Single Photon Detector (1채널 단일광자검출기를 이용한 낮은 광출력의 SWIR(Short Wave Infrared) 3D 라이다 시스템 개발)

  • Kwon, Oh-Soung;Lee, Seung-Pil;Shin, Seung-Min;Park, Min-Young;Ban, Chang-Woo
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.25 no.6_3
    • /
    • pp.1147-1154
    • /
    • 2022
  • Now that the development of autonomous driving is progressing, LiDAR has become an indispensable element. However, LiDAR is a device that uses lasers, and laser side effects may occur. One of them is the much-talked-about eye-safety, and developers have been satisfying this through laser characteristics and operation methods. But eye-safety is just one of the problems lasers pose. For example, irradiating a laser with a specific energy level or higher in a dusty environment can cause deterioration of the dust particles, leading to a sudden explosion. For this reason, the dust ignition proof regulations clearly state that "a source with a pulse period of less than 5 seconds is considered a continuous light source, and the average energy does not exceed 5 mJ/mm 2 or 35 mW" [2]. Energy of output optical power is limited by the law. In this way, the manufacturer cannot define the usage environment of the LiDAR, and the development of a LiDAR that can be used in such an environment can increase the ripple effect in terms of use in application fields using the LiDAR. In this paper, we develop a LiDAR with low optical power that can be used in environments where high power lasers can cause problems, evaluate its performance. Also, we discuss and present one of the directions for the development of LiDAR with laser power limited by dust ignition proof regulations.

The Study on a sensitive current limiting breaking device using RF Sputtering (RF Sputtering을 이용한 전류 민감성 차단 디바이스에 관한 연구)

  • Lee, S.H.;Jeong, K.H.;Park, D.K.;Kim, Y.L.;Lee, J.C.;Koo, K.W.;Han, S.O.
    • Proceedings of the KIEE Conference
    • /
    • 1995.07c
    • /
    • pp.1088-1092
    • /
    • 1995
  • In this paper, we evaluated the sputter-deposited Cr/Cu thin film fuses on $Al_2O_3$ substrates by the adhesive, breaking and repetitive over-current test as a function of temperature on them. Each Cr and Cu was deposited $1700{\pm}300{\AA},\;3700{\pm}300{\AA}$ using RF sputtering unit. The electroplated Cu of $25{\mu}m$ thickness was added in order to make sensitive thin film fuse of the normal current 15[A]. The adhesive strength and the number of repetition were Increasing and then decreasing with the temperature. The maximum adhesive strength of over $9kgf/9mm^2$ was obtained at $400^{\circ}C$. In the breaking test, the post-arc time characteristic was better than any other factor.

  • PDF

Development of Image Capture Program for a Mobile Mapping System along CCD Camera Characteristics (차량측량시스템을 위한 영상취득 프로그램 개발)

  • Jeong, Dong-Hoon;Kim, Byung-Guk
    • Journal of Korea Spatial Information System Society
    • /
    • v.4 no.2 s.8
    • /
    • pp.35-40
    • /
    • 2002
  • In this study we developed a CCD camera image capture program for Mobile Mapping System. Especially, two high resolution color images could be captured and saved simultaneously through this program to apply digital photogrammetry. Program developed in this study could be used more effectively on the 3D positioning of road facilities, the state understanding of maintenance and etc. using Mobile Mapping System with GPS-IMU. Most programs currently developed and used are for the panchromatic images. But, newly developed program is for the high resolution color images. Therefore newly developed program could expand application field of Mobile Mapping System widely, and users. This research can improve the usability of 4S' products with stable and reliable.

  • PDF

The Effect of TiAlN coated Ball End Mill and MQL Cutting Condition on Cutting characteristic of High Hardness Steels (고경도 강재의 MQL 가공시 초경 볼 엔드밀의 TiAlN 코팅 조건이 절삭 특성에 미치는 영향)

  • Park D. S.;Won S. T.;Lee Y. J.;Hur J. H.
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 2004.10a
    • /
    • pp.245-251
    • /
    • 2004
  • This paper is studied on the effect of TiAlN coated Ball End Mill and MQL(Minimum Quantity Lubrication) cutting condition on cutting characteristic of high hardness steels. KP4 steels[HRC32] and STD11[HRC60] heat treated steels were used as the workpiece and WC-Co ball end mill and single and multi layer TiAlN coated ball end mill were utilized in the cutting tests. MQL device was used to spray botanical oil coolant. Result showed that TiAlN coated ball end mill were increased the cutting length than WC-Co ball end mill in the cutting speed[$245{\sim}320m/min$] about $2.3{\sim}5.7$ times for KP4 steels and about $2.5{\sim}4.3$ times far STD11 heat treated steels. The multi layer TiAlN coated ball end mill is good for KP4 steels than single layer coated.

  • PDF

Development of a 3.6 MW, $4\;{\mu}s$, 200 pps Pulse Modulator for a High Power Magnetron (고출력 마그네트론 구동용 3.6 MW, $4\;{\mu}s$, 200 pps 펄스 모듈레이터 개발)

  • Jang Sung-Duck;Kwon Sei-Jin;Bae Young-Soon;Oh Jong-Seok;Cho Moo-Hyun;Namkung Won;Son Yoon-Kyoo
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.54 no.3
    • /
    • pp.120-126
    • /
    • 2005
  • The Korean Superconducting Tokamak Advanced Research (KSTAR) tokamak device is being constructed to perform long-pulse, high-beta, advanced tokamak fusion physics experiments. The long-pulse operation requires the non-inductive current drive system such as the Lower-Hybrid Current Drive (LHCD) system. The LHCD system drives the non-inductive plasma current by means of C-band RF with 2-MW CW power and 5-GHz frequency. For the LHCD test experiments, an RF test system is developed. It is composed of a 5-GHz, 1.5-MW pulsed magnetron and a compact pulse modulator with $4\;{\mu}s$ of pulse width. The pulse modulator provides the maximum output voltage of 45 kV and the maximum current of 90 A. It is composed of 7 stages of Pulse Forming Network (PFN), a thyratron tube (E2V, CX1191D), and a pulse transformer with 1:4 step-up ratio. In this paper, the detailed design and the performance test of the pulse modulator are presented.