• Title/Summary/Keyword: Device to Device (D2D)

Search Result 1,734, Processing Time 0.038 seconds

Synthesis of Novel Y-type Nonlinear Optical Polyester with Enhanced Thermal Stability of Second Harmonic Generation for Electro-Optic Applications

  • Cho, You-Jin;Lee, Ju-Suk;Lee, Ju-Yeon
    • Bulletin of the Korean Chemical Society
    • /
    • v.31 no.6
    • /
    • pp.1509-1514
    • /
    • 2010
  • Methyl 3,4-di-(2'-hydroxyethoxy)benzylidenecyanoacetate (3) was prepared and condensed with terephthaloyl chloride to yield novel Y-type polyester (4) containing 3,4-dioxybenzylidenecyanoacetate groups as NLO-chromophores, which constituted parts of the polymer main chains. The resulting polymer 4 is soluble in common organic solvents such as acetone and N,N-dimethylformamide. Polymer 4 shows thermal stability up to $280^{\circ}C$ in thermogravimetric analysis with glass-transition temperature obtained from differential scanning calorimetry near $105^{\circ}C$. The second harmonic generation (SHG) coefficient ($d_{33}$) of poled polymer films at the 1064 nm fundamental wavelength is around 2.42 pm/V. The dipole alignment exhibits high thermal stability up to near $T_g$, and there is no SHG decay below $100^{\circ}C$ due to the partial main-chain character of polymer structure, which is acceptable for NLO device applications.

Evaluation of Manufactured Device for Radiation therapy in Head and Neck Cancer (두경부암 환자의 방사선 치료시 자체 제작한 고정용구 (Shoulder Retractor)에 대한 유용성 평가)

  • Kim, Tae Jun;Jin, Sun Sik;Kim, Dong Hyun;Kim, Dong Wook;Chung, Weon Kuu;Kim, Kyoung Tae
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.26 no.1
    • /
    • pp.99-105
    • /
    • 2014
  • Purpose : We compared the set-up accuracy and right-left Shoulder position variation of the manufactured device and other commercial shoulder-retractors in the head and neck radiation treatment. Materials and Methods : Six patients consist of three groups which were used three different Shoulder retractors. We measured position corrections of left and right Shoulder and the couch after the image guidance by using on board imager (OBI) for six head and neck patients who has the extended target to the neck node lower region. Results : The position variation correction of left (right) Shoulder after image guidance were $1.07{\pm}3.99mm$ ($-4.35{\pm}2.09mm$), $-0.37{\pm}5.91mm$ ($1.26{\pm}5.28mm$), $-0.63{\pm}2.44mm$ ($0.25{\pm}1.61mm$) for group A, B and C. The vertical, lateral, longitudinal position and angular corrections of the couch after image guidance were $-2.06{\pm}2.68$, $-1.11{\pm}8.15$, $0.34{\pm}3.78mm$, and $0.51{\pm}0.77$ degree for group A, $-1.18{\pm}1.82$, $-0.94{\pm}2.13$, $-0.67{\pm}1.98mm$, and $0.91{\pm}1.04$ degree for group B and $0.12{\pm}2.18$, $-0.79{\pm}2.64$, $0.79{\pm}2.64$, and $0.00{\pm}0.49$ degree for group C. Conclusion : In this preliminary study, we found the positioning accuracy of the manufactured Shoulder retractor is comparable to other commercial Shoulder retractors. We expect that the reproducibility and accuracy of the patient set-up could be improved by using the home made Shoulder retractor in the head and neck radiation treatment.

Structural, Optical, and Electrical Characterization of p-type Graphene for Various AuCl3 Doping Concentrations (AuCl3를 도핑하여 제작한 p형 그래핀의 도핑농도에 따른 구조적, 광학적, 및 전기적 특성 연구)

  • Kim, Sung;Shin, Dong Hee;Choi, Suk-Ho
    • Journal of the Korean Vacuum Society
    • /
    • v.22 no.5
    • /
    • pp.270-275
    • /
    • 2013
  • Single-layer graphene layers have been synthesized by using chemical vapor deposition, subsequently transferred on 300 nm $SiO_2/Si$ and quartz substrates, and doped with $AuCl_3$ by spin coating for various doping concentrations ($n_D$) from 1 to 10 mM. Based on the $n_D$-dependent variations of Raman frequencies/peak-intensity ratios, sheet resistance, work function, and Dirac point, measured by structural, optical, and electrical analysis techniques, the p-type nature of graphene is shown to be strengthened with increasing $n_D$. Especially, as estimated from the drain current-gate voltage curves of graphene field effect transistors, the hole mobility is very little varied with increasing $n_D$, in strong contrast with the $n_D$-dependent large variation of electron mobility. These results suggest that $AuCl_3$ is one of the best p-type dopants for graphene and is promising for device applications of the doped graphene.

Investigation on the P3HT-based Organic Thin Film Transistors (P3HT를 이용한 유기 박막 트랜지스터에 관한 연구)

  • Kim, Y.H.;Park, S.K.;Han, J.I.;Moon, D.G.;Kim, W.G.;Lee, C.J.
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2002.04b
    • /
    • pp.45-48
    • /
    • 2002
  • Poly(3-hexylthiophene) or P3HT based organic thin film transistor (OTFT) array was fabricated on flexible poly carbonate substrates and the electrical characteristics were investigated. As the gate dielectric, a dual layer structure of polyimide-$SiO_2$ was used to improve the roughness of $SiO_2$ surface and further enhancing the device performance and also source-drain electrodes were $O_2$ plasma treated for improvement of the electrical properties, such as drain current and field effect mobility. For the active layer, polymer semiconductor, P3HT layer was printed by contact-printing and spin-coating method. The electrical properties of OTFT devices printed by both methods were evaluated for the comparison. Based on the experiments, P3HT-based OTFT array with field effect mobility of 0.02~0.025 $cm^{2}/V{\cdot}s$ and current modulation (or $I_{on}/I_{off}$ ratio) of $10^{3}\sim10^{4}$ was fabricated.

  • PDF

Polymer Optical Microring Resonator Using Nanoimprint Technique (나노 임프린트 기술을 이용한 폴리머 링 광공진기)

  • Kim, Do-Hwan;Im, Jung-Gyu;Lee, Sang-Shin;Ahn, Seh-Won;Lee, Ki-Dong
    • Korean Journal of Optics and Photonics
    • /
    • v.16 no.4
    • /
    • pp.384-391
    • /
    • 2005
  • A polymer optical microring resonator, which is laterally coupled to a straight bus waveguide, has been proposed and demonstrated using a nanoimprint technique. The propagation loss of the ring waveguide and the optical power coupling between the ring and bus waveguides was calculated by using a beam propagation method, then the dependence of the device performance on them was investigated using a transfer matrix method. We have especially introduced an imprint stamp incorporating a smoothing buffer layer made of a silicon nitride thin film. This layer played an efficient role in improving the sidewall roughness of the waveguide pattern engraved on the stamp and thus reducing the scattering loss. As a result the overall Q factor of the resonator was greatly increased. Also it reduced the gap between the ring and bus waveguides effectively to enhance the coupling between them, without relying on the direct writing method based on an e-beam writer. As for the achieved device performance at the wavelength of 1550 nm, the quality factor, the extinction ratio, and the free spectral range were ~103800, ~11 dB, and 1.16 m, respectively.

Fabrication and characteristics for the organic light emitting device from single layer poly(N-vinylcarbazole) (단층 poly(N-vinylcarbazole) 유기물 전기발광 소자의 제작 및 특성)

  • 윤석범;오환술
    • Journal of the Korean Institute of Telematics and Electronics D
    • /
    • v.35D no.11
    • /
    • pp.55-61
    • /
    • 1998
  • Organic light emitting devices from a single layer thin film with a hole transport polymer, poly(N-vinylcarbazole) (PVK) doped with 2-(4-bi phenyl)-5-(4-t-butyl-phenyl) -1,3,4-oxadiazole (Bu-PBD) as electron transporting molecules and Coumurine 6(C6), 1,1,4,4-tetraphenyl-1,3-butadiene (TPB), Rhodamine B as a emitter dye were fabricated. The sing1e layer structure and the use of soluble materials simplify the fabrication of devices by spin coating technique. The active layer consists of one polymer layer that is simply sandwiched between two electrodes, indium-tin oxide (ITO), and aluminum. In this structure, electron and hole inject from the electrodes to the PVK : Bu-PBD active layer. Respectively, Blue, green and orange colored emission spectrum by the use of TPB, C6, Rhodamine B dye emitted at 481nm, 500nm and 585nm were achieved during applied voltages. PVK materials can be useful as the host polymer to be molecularly doped with other organic dyes of the different luminescence colors. And EL color can be tuned to the full visible wavelength.

  • PDF

Gesture interface with 3D accelerometer for mobile users (모바일 사용자를 위한 3 차원 가속도기반 제스처 인터페이스)

  • Choe, Bong-Whan;Hong, Jin-Hyuk;Cho, Sung-Bae
    • 한국HCI학회:학술대회논문집
    • /
    • 2009.02a
    • /
    • pp.378-383
    • /
    • 2009
  • In these days, many systems are equipped with people to infer their intention and provide the corresponding service. People always carry their own mobile device with various sensors, and the accelerator takes a role in this environment. The accelerator collects motion information, which is useful for the development of gesture-based user interfaces. Generally, it needs to develop an effective method for the mobile environment that supports relatively less computational capability since huge computation is required to recognize time-series patterns such as gestures. In this paper, we propose a 2-stage motion recognizer composed of low-level and high-level motions based on the motion library. The low-level motion recognizer uses the dynamic time warping with 3D acceleration data, and the high-level motion is defined linguistically with the low-level motions.

  • PDF

Design of piezoelectric micro-machined ultrasonic transducer for wideband ultasonic radiation in air (공기 중 광대역 초음파 방사용 압전 박막 기반 초소형 초음파 트랜스듀서의 설계)

  • Ahn, Hongmin;Jin, JaeHyeok;Moon, Wonkyu
    • The Journal of the Acoustical Society of Korea
    • /
    • v.39 no.2
    • /
    • pp.87-97
    • /
    • 2020
  • In this paper, the design of piezoelectric Micro-machined Ultrasonic Transducer (pMUT) for wideband ultrasonic radiation in air was investigated. One of the methods to achieve wide frequency bandwidth in single device is modeling the transducer to multi-resonance system. The new pMUT was designed as a multi-resonance system with the addition of a suitable acoustic structure to the front and back of a thin film structure. A new pMUT consisting of thin film parts, radiation parts, and packaging parts is designed with a Lumped Parameter Model (L.P.M). Finally, it was validated as a Finite Element Method (FEM) simulation. The final designed pMUT achieved a frequency band of 102 kHz ~ 132 kHz (-3 dB).

Study on Frequency Selection Method Using Case-Based Reasoning for Cognitive Radio (사례기반 추론 기법을 이용한 인지 라디오 주파수 선택 방법 연구)

  • Park, Jae-Hoon;Choi, Jeung Won;Um, Soo-Bin;Lee, Won-Cheol
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.12 no.1
    • /
    • pp.58-71
    • /
    • 2019
  • This paper proposes architecture of a cognitive radio engine platform and the allowable frequency channel reasoning method that enables acquisition of the allowable channels for the military tactical network environment. The current military tactical wireless communication system is increasing need to secure a supplementary radio frequency to ensure that multiple wireless networks for different military wireless devices coexist, so that tactical wireless communication between the same or different systems can be operated effectively. This paper presents the allowable frequency channel reasoning method based on cognitive radio engine for realizing DSA(Dynamic Spectrum Access) as an optimal available frequency channel. To this end, a case-based allowable frequency channel reasoning method for cognitive radio devices is proposed through modeling of primary user's traffic status and calculation of channel occupancy probability. Also through the simulation of the performance analysis, changing rate of collision probability between the primary users' occupancy channel and the available channel acquisition information that can be used by the cognitive radio device was analysed.

Direction detection technique of radioactive contaminants based on rotating collimator (회전형 콜리메이터 기반 방사능 오염원의 방향탐지 기법)

  • Hwang, Young-Gwan;Song, Keun-Young;Lee, Nam-Ho
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.24 no.11
    • /
    • pp.1519-1527
    • /
    • 2020
  • AGeneral radiation measuring devices have been developed in the form of spatial dose rate detection devices that measure dose rates to radioactive contaminant and 2D or 3D imaging devices for radioactive contamination information. Each of these radiation detection techniques has advantages. The advantages of both detection devices are necessary to minimize personal injury and rapid decontamination in the area of a radioactive accident. In this paper, we proposed a technique that can measure the dose rate and direction information about the radioactive pollutant source in real time using a detection sensor, a rotating body, and a directional shield for radioactive pollutant detection. The rotational-based detection device is configured to check the dose rate and direction using the location information of the rotator and measurement value. We proposed a measurement technique for vertical and horizontal directions through multiple holes. It was confirmed that the measurement error for direction information was less than 1% when detected in the horizontal direction.