• Title/Summary/Keyword: Device to Device (D2D)

Search Result 1,734, Processing Time 0.043 seconds

Integrated RT-PCR Microdevice with an Immunochromatographic Strip for Colorimetric Influenza H1N1 virus detection

  • Heo, Hyun Young;Kim, Yong Tae;Chen, Yuchao;Choi, Jong Young;Seo, Tae Seok
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2013.08a
    • /
    • pp.273-273
    • /
    • 2013
  • Recently, Point-of-care (POC) testing microdevices enable to do the patient monitoring, drug screening, pathogen detection in the outside of hospital. Immunochromatographic strip (ICS) is one of the diagnostic technologies which are widely applied to POC detection. Relatively low cost, simplicity to use, easy interpretations of the diagnostic results and high stability under any circumstances are representative advantages of POC diagnosis. It would provide colorimetric results more conveniently, if the genetic analysis microsystem incorporates the ICS as a detector part. In this work, we develop a reverse transcriptase-polymerase chain reaction (RT-PCR) microfluidic device integrated with a ROSGENE strip for colorimetric influenza H1N1 virus detection. The integrated RT-PCR- ROSGENE device is consist of four functional units which are a pneumatic micropump for sample loading, 2 ${\mu}L$ volume RT-PCR chamber for target gene amplification, a resistance temperature detector (RTD) electrode for temperature control, and a ROSGENE strip for target gene detection. The device was fabricated by combining four layers: First wafer is for RTD microfabrication, the second wafer is for PCR chamber at the bottom and micropump channel on the top, the third is the monolithic PDMS, and the fourth is the manifold for micropump operation. The RT-PCR was performed with subtype specific forward and reverse primers which were labeled with Texas-red, serving as a fluorescent hapten. A biotin-dUTP was used to insert biotin moieties in the PCR amplicons, during the RT-PCR. The RT-PCR amplicons were loaded in the sample application area, and they were conjugated with Au NP-labeled hapten-antibody. The test band embedded with streptavidins captures the biotin labeled amplicons and we can see violet colorimetric signals if the target gene was amplified with the control line. The off-chip RT-PCR amplicons of the influenza H1N1 virus were analyzed with a ROSGENE strip in comparison with an agarose gel electrophoresis. The intensities of test line was proportional to the template quantity and the detection sensitivity of the strip was better than that of the agarose gel. The test band of the ROSGENE strip could be observed with only 10 copies of a RNA template by the naked eyes. For the on-chip RT-PCR-ROSGENE experiments, a RT-PCR cocktail was injected into the chamber from the inlet reservoir to the waste outlet by the micro-pump actuation. After filling without bubbles inside the chamber, a RT-PCR thermal cycling was executed for 2 hours with all the microvalves closed to isolate the PCR chamber. After thermal cycling, the RT-PCR product was delivered to the attached ROSGENE strip through the outlet reservoir. After dropping 40 ${\mu}L$ of an eluant buffer at the end of the strip, the violet test line was detected as a H1N1 virus indicator, while the negative experiment only revealed a control line and while the positive experiment a control and a test line was appeared.

  • PDF

Development of Device Measuring Real-time Air Flow in Greenhouse (온실 공기유동 계측 시스템 개발)

  • Noh, Jae Seung;Kwon, Jinkyoung;Kim, Yu Yong
    • Journal of Bio-Environment Control
    • /
    • v.27 no.1
    • /
    • pp.20-26
    • /
    • 2018
  • This study was conducted to develop a device for measuring the air flow by space variation through monitoring program, which acquires data by each point from each environmental sensor located in the greenhouse. The distribution of environmental factors(air temperature, humidity, wind speed, etc.) in the greenhouse is arranged at 12 points according to the spatial variation and a large number of measurement points (36 points in total) on the X, Y and Z axes were selected. Considering data loss and various greenhouse conditions, a bit rate was at 125kbit/s at low speed, so that the number of sensors can be expanded to 90 within greenhouse with dimensions of 100m by 100m. Those system programmed using MATLAB and LabVIEW was conducted to measure distributions of the air flow along the greenhouse in real time. It was also visualized interpolated the spatial distribution in the greenhouse. In order to verify the accuracy of CFD modeling and to improve the accuracy, it will compare the environmental variation such as air temperature, humidity, wind speed and $CO_2$ concentration in the greenhouse.

Development of Electronic Circuit for Korotkoff Sounds Detecting Signal on Forearm Electronic Blood Pressure Monitor (팔뚝 전자혈압계의 코로트코프 음 신호 검출을 위한 전자 회로 개발)

  • Lee, Sangsik;Cho, Yoehan;Goo, Jihyun;Lee, Choongho
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.3 no.1
    • /
    • pp.3-7
    • /
    • 2010
  • In this study, we developed a circuit device detecting korotkoff sounds of forearm electronic blood pressure monitor by digital signal. In order to test a circuit detecting signal from korotkoff sounds, systolic and diastolic pressure were compared our developed circuit device with the existing forearm electronic blood pressure monitor (Model: SE-7000, Korea). Devices for an experiment composed of a forearm cuff, a stethoscope, an amplifier, a PC with A/D board, etc. Results of korotkoff sounds was similar to a pattern of oscilometric signals from the existing forearm electronic blood pressure monitor. We thought it is possible to measure blood pressures, if blood pressures were detected precisely using signals of korotkoff sounds.

  • PDF

Objective Evaluation of Beamforming Techniques for Hearing Devices with Two-channel Microphone (2채널 마이크로폰을 이용한 청각 기기에서의 빔포밍에 대한 객관적 검증)

  • Cho, Kyeong-Won;Han, Jong-Hee;Hong, Sung-Hwa;Lee, Sang-Min;Kim, Dong-Wook;Kim, In-Young;Kim, Sun-I.
    • Journal of Biomedical Engineering Research
    • /
    • v.32 no.3
    • /
    • pp.198-206
    • /
    • 2011
  • Hearing devices like cochlear implant, vibrant soundbridge, etc. try to offer better sound for people. In hearing devices, several beamformers including conventional directional microphone are applicable to noise reduction. Each beamformer has different directional response and it could change sound intelligibility or quality for listeners. Therefore, we investigated the performance of three beamformers, which are first and second order directional microphone, and broadband beamformer(BBF) with a computer simulation assuming hearing device microphone configuration. We also calculated objective measurements which have been used to evaluate speech enhancement algorithms. In the simulation, a single speech and a single babble noisewere propagated from the front and $135^{\circ}$ azimuth degrees respectively. Microphones were configured in an end-fire array and the spacing was varied in comparison. With 3 cm spacing, BBF had about 3 dB higher enhanced SNR than that of directional microphones. However, enhancement of segmental SNR and frequency weighted segmental SNR were similar between the first order directional microphone and broadband beamformer. In addition when steady state noise was used, broadband beamformer showed the increased performance and had the highest enhanced SNR, and segmental SNR.

Fabrication Method of OPV using ESD Spray Coating (ESD 스프레이를 이용한 OPV 제작 기법)

  • Kim, Jungsu;Jo, Jeongdai;Kim, Dongsoo
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2010.06a
    • /
    • pp.84.2-84.2
    • /
    • 2010
  • PEMS (printed electro-mechanical system) is fabricated by means of various printing technologies. Passive and active components in 2D or 3D such as conducting lines, resistors, capacitors, inductors and TFT, which are printed with functional materials, can be classified in this category. And the issue of PEMS is applied to a R2R process in the manufacturing process. In many electro-devices, the vacuum process is used as the manufacturing process. However, the vacuum process has a problem: it is difficult to apply toa continuous process as a R2R printing process. In this paper, we propose an ESD (electro static deposition) printing process has been used to apply an organic solar cell of thin film forming. ESD is a method of liquid atomization by electrical forces, anelectrostatic atomizer sprays micro-drops from the solution injected into the capillary, with electrostatic force generated by electric potential of about tens of kV. ESD method is usable in the thin film coating process of organic materials and continuous process as a R2R manufacturing process. Therefore, we experiment the thin films forming of PEDOT:PSS layer and Active layer which consist of the P3HT:PCBM. The result of experiment, organic solar cell using ESD thin film coated method is occurred efficiency of about 1.4%. Also, the case of only used to ESD method in the active layer coating is occurred efficiency of about 1.86% as the applying a spin coating in the PEDOT:PSS layer. We can expect that ESD method is possible for continuous process to manufacture in the organic solar cell or OLED device.

  • PDF

SINTERED $Al_{2}O_{3}$-TiC SUBSTRATE FOR THIN FILM MAGNETIC HEAD

  • Nakano, Osamu;Hirayama, Takasi
    • Proceedings of the Korean Powder Metallurgy Institute Conference
    • /
    • 1998.04b
    • /
    • pp.6-6
    • /
    • 1998
  • In 1957, the first magnetic disk drive compatible with a movable head was introduced as an external file memory device for computer system. Since then, magnetic disks have been improved by increasing the recording density, which has brought about the development of a high performance thin film magnetic head. The thin film magnetic head has a magnetic circuit on a ceramic substrate using IC technology. The physical property of the substrate material is very important because it influences the tribology of head/disk interface and also manufacturing process of the head. $Al_{2}O_{3}$-TiC ceramics, so called ALTIC, is known to be one of the best substrate materials which satisfies this property requirement. Even though the head is not in direct contact with the disk, frequent instantaneous contacts are unavoidable due to its high rotating speed and the close gap between them. This may cause damage in the magnetic recording media and, thus, it is very important that the magnetic head has a good wear resistance. $Al_{2}O_{3}$-TiC ceramics has an excellent tribological property in head/disk interface. Manufacturing process of thin film head is similar to that of IC, which requires extremely smooth and flat surface of the substrate. The substrate must be readily sliced into the heads without chipping. $Al_{2}O_{3}$-TiC ceramics has excellent machineability and mechanical properties. $Al_{2}O_{3}$-TiC ceramics was first developed at Nippon Tungsten Co. as cutting tool materials in 1968, which was further developed to be used as the substrate materials for thin film head in collaboration with Sumitomo Special Metals Co., Ltd. in 1981. Today, we supply more than 60% of the substrates for thin film head market in the world. In this paper, we would like to present the sintering process of $Al_{2}O_{3}$-TiC ceramics and its property in detail.

  • PDF

Effect of Critical Cooling Rate on the Formation of Intermetallic Phase During Rapid Solidification of FeNbHfBPC Alloy

  • Kim, Song-Yi;Oh, Hye-Ryeong;Lee, A-Young;Jang, Haneul;Lee, Seok-Jae;Kim, Hwi-Jun;Lee, Min-Ha
    • Journal of Korea Foundry Society
    • /
    • v.41 no.3
    • /
    • pp.235-240
    • /
    • 2021
  • We present the effect of the critical cooling rate during rapid solidification on the nucleation of precipitates in an Fe75B13P5Nb2Hf1C4 (at.%) alloy. The thermophysical properties of the rapidly solidified Fe75B13P5Nb2Hf1C4 liquids, which were obtained at various cooling rates with various sizes of gas-atomized powder during a high-pressure inert gas-atomization process, were evaluated. The cooling rate of the small-particle powder (≤20 ㎛) was 8.4×105 K/s, which was 13.5 times faster than that of the large-particle powder (20 to 45 mm; 6.2×104 K/s) under an atomized temperature. A thermodynamic calculation model used to predict the nucleation of the precipitates was confirmed by the microstructural observation of MC-type carbide in the Fe75B13P5Nb2Hf1C4 alloy. The primary carbide phase was only formed in the large-particle gas-atomized powder obtained during solidification at a slow cooling rate compared to that of the small-particle powder.

A Study on Efficiency Improvement and Optimization of Operating Characteristics of Pulsed $CO_2$ Laser System using Ring Blower (링 블로우를 이용한 펄스형 $CO_2$ 레이저 시스템의 효율 향상과 동작 특성에 관한 연구)

  • Kim, D.H.;Chung, H.J.;Park, S.J.;Joung, J.H.;Lee, D.H.;Kim, H.J.;Cho, J.S.
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2000.05b
    • /
    • pp.57-60
    • /
    • 2000
  • In this paper, it is purpose to develop a pulsed $CO_2$ laser with stable output at pulse repetition rate range of 2 KHz. We used a IGBT as a switching device. The laser cavity was fabricated as an axial and water cooled type. It was used a ring blower to increase a cooling effect The laser performance characteristics as parameters, such as pulse repetition rate, gas pressure have been investigated. The experiment was done under 3 electrode-type instead of 2 electrode-type. To achieve 3 electrode-type, we used two pulse-transformers which is operated parallel. As a result, the maximum output was about 28 W at the total pressure of 20 Torr, the gas mixture $Co_2$:$N_2$:He=1:9:15 and the pulse repetition rate of 1300 Hz.

  • PDF

Device and Piezoelectric Characteristics of Pb(Mn1/3Sb2/3) O3-PZT Ceramics for Piezoelectric Transformer

  • Sohn, Joon-Ho;Heo, Soo-Jeong;Sohn, Jeong-Ho;Lee, Joon-Hyung;Jung, Woo-Hwan;Kim, Dong-Bum;Cho, Sang-Hee
    • The Korean Journal of Ceramics
    • /
    • v.5 no.2
    • /
    • pp.171-177
    • /
    • 1999
  • In the $(Pb_{1-x}M_x)[(Mn_{1/3}Sb_{2/3})_{0.05}Zr_yTi_{0.95-y}]O_3$ system, where M=Ca and Sr, the piezoelectric properties were evaluated to examine the possibility of application to piezoelectric transformer. A Rosen-type piezoelectric transformer was formed, then the electrical properties of voltage step-up ratio, frequency characteristics etc. were analysed. The morphotropic phase boundary was determined to be y=0.475 in $Pb[(Mn_{1/3}Sb_{2/3})_{0.05}Zr_yTi_{0.95-y}]O_3$ system and the piezoelectric properties of this composition was kp=0.59, Qm=1600 and $\varepsilon_r$=1150. Moreover, when 1-2 mol% of Sr are substituted, enhanced piezoelectric properties of kp=0.61, Qm=1600 and $\varepsilon_r$=1400 were shown. The temperature rising (ΔT) of a piezoelectric transformer with $Pb[Mn_{1/3}Sb_{2/3})_{0.05}Zr_{0.475}Ti_{0.475})]O_3 $ composition was $10^{\circ}C$, and the voltage step-up ratio was 500 when the output voltage was 4000V, whereas the ΔT was below $3^{\circ}C$ and the resonant frequency variation ($\Delta f_r$) as a function of load resistance was below 5% when the output voltage was 2000 V. These characteristics are superior to the properties of materials, which were substituted by Ca or without substitution.

  • PDF

A Study on Efficiency Improvement and Optimization of Operating Characteristics of Pulsed $CO_2$ Laser System using 3 Electrode-type and Ring Blower (3전극 방식과 링 블로우를 이용한 펄스형 $CO_2$ 레이저 시스템의 효율 향상과 동작 특성에 관한 연구)

  • Kim, D.W.;Chung, H.J.;Park, S.J.;Lee, Y.S.;Lee, D.H.;Kim, H.J.;Cho, J.S.
    • Proceedings of the KIEE Conference
    • /
    • 2000.07c
    • /
    • pp.2101-2103
    • /
    • 2000
  • In this paper, it is purpose to develop a pulsed $CO_2$ laser with stable output at pulse repetition rate range of 2 kHz. We used a IGBT as a switching device. The laser cavity was fabricated as an axial and water cooled type. It was used a ring blower to increase a cooling effect. The laser performance characteristics as parameters, such as pulse repetition rate, gas pressure have been investigated. The experiment was done under 3 electrode-type instead of 2 electrode-type. To achieve 3 electrode-type, we used two pulse-transformers which is operated parallel. As a result. the maximum output was about 28 W at the total pressure, of 20 Torr(the gas mixture $CO_2$:$N_2$:He=1:9:15 and the pulse repetition rate of 1300 Hz).

  • PDF