• Title/Summary/Keyword: Device error

Search Result 1,154, Processing Time 0.023 seconds

Implementation of Vehicle Navigation System using GNSS, INS, Odometer and Barometer

  • Park, Jungi;Lee, DongSun;Park, Chansik
    • Journal of Positioning, Navigation, and Timing
    • /
    • v.4 no.3
    • /
    • pp.141-150
    • /
    • 2015
  • In this study, a Global Navigation Satellite System (GNSS) / Inertial Navigation System (INS) / odometer / barometer integrated navigation system that uses a commercial navigation device including Micro Electro Mechanical Systems (MEMS) accelerometer and gyroscope in addition to GNSS, odometer information obtained from a vehicle, and a separate MEMS barometer sensor was implemented, and the performance was verified. In the case of GNSS and GNSS/INS integrated navigation system that are generally used in a navigation device, the performance would deteriorate in areas where GNSS signals are not available. Therefore, an integrated navigation system that calculates a better navigation solution in areas where GNSS signals are not available compared to general GNSS/INS by correcting the velocity error of GNSS/INS using an odometer and by correcting the cumulative altitude error of GNSS/INS using a barometer was suggested. To verify the performance of the navigation system, a commercial navigation device (Softman, Hyundai Mnsoft, http://www.hyundai-mnsoft.com) and a barometer sensor (ST Company) were installed at a vehicle, and an actual driving test was performed. To examine the performance of the algorithm, the navigation solutions of general GNSS/INS and the GNSS/INS/odometer/barometer integrated navigation system were compared in an area where GNSS signals are not available. As a result, a navigation solution that has a smaller position error than that of GNSS/INS could be obtained in the area where GNSS signals are not available.

A Correcting Method of the GPS Location Information using one CCTV in Smart Care Surveillance System (스마트 케어 감시 시스템에서 한 대의 CCTV를 이용한 GPS 위치정보의 보정 방법)

  • Park, Eunsung;Kim, Kiyong
    • Journal of IKEEE
    • /
    • v.20 no.2
    • /
    • pp.143-151
    • /
    • 2016
  • Smart care surveillance system can take the position information of the user and monitor by controlling neighbor CCTVs using GPS receiver built into smart device. But because the position information contains a significant error, in general smart device, it is necessary to be corrected for precise monitoring. In previous smart care system, this error is corrected by using a plurality of CCTV. But it has disadvantage that two or more CCTVs pointed toward the same point at the same time. In this paper, we propose the method to correct error of the GPS location information by using only one CCTV. With experiment result, we find that the accuracy of GPS location information corrected with only one CCTV is as improved as two CCTVs.

A Mobile Flash File System - MJFFS (모바일 플래시 파일 시스템 - MJFFS)

  • 김영관;박현주
    • Journal of Information Technology Applications and Management
    • /
    • v.11 no.2
    • /
    • pp.29-43
    • /
    • 2004
  • As the development of an information technique, gradually, mobile device is going to be miniaturized and operates at high speed. By such the requirements, the devices using a flash memory as a storage media are increasing. The flash memory consumes low power, is a small size, and has a fast access time like the main memory. But the flash memory must erase for recording and the erase cycle is limited. JFFS is a representative filesystem which reflects the characteristics of the flash memory. JFFS to be consisted of LSF structure, writes new data to the flash memory in sequential, which is not related to a file size. Mounting a filesystem or an error recovery is achieved through the sequential approach. Therefore, the mounting delay time is happened according to the file system size. This paper proposes a MJFFS to use a multi-checkpoint information to manage a mass flash file system efficiently. A MJFFS, which improves JFFS, divides a flash memory into the block for suitable to the block device, and stores file information of a checkpoint structure at fixed interval. Therefore mounting and error recovery processing reduce efficiently a number of filesystem access by collecting a smaller checkpoint information than capacity of actual files. A MJFFS will be suitable to a mobile device owing to accomplish fast mounting and error recovery using advantage of log foundation filesystem and overcoming defect of JFFS.

  • PDF

Development of Wireless Device for Inspecting Crankshaft Deflection Using Linear Encoder (리니어 엔코더를 이용한 선박 엔진용 무선 크랭크 샤프트 디플렉션 검사 장치 개발)

  • Kim, Jang-Kyu;Lee, Min-Cheol
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.26 no.5
    • /
    • pp.104-111
    • /
    • 2009
  • A ship engine operator should compensate the crankshaft assembly of ship engine after inspecting crankshaft deflection error in the crank throw regularly to avoid engine vibration and abrasions. In the previous method, the operator enters the bed plate and measures crankshaft deflection using dial gauge on rotating crankshaft manually. However, this method can cause dangerous situation to the operator as well as uncomfortable in an inferior environment. In order to solve the problems, this paper studies the method which makes the operator measure the error outside of the bed plate. In this paper, it is suggested that BlueTooth wireless communication transfers the error data to the outer standing operator with digitalized crankshaft deflection inspection device developed in this paper. So, the wireless measurement system is developed and applied to a medium-speed marine engine through size-miniaturization. After applying test, the developed inspection device showed that it provides much safe and ease inspection method. Furthermore, in the result, the measuring accuracy is more improved.

A Study on the Improvement Method for Preventing Lift Stop Position Error using Double Sensor Based Lift Stop Sensing Device (Double Sensor Type 감지장치를 통한 리프트 정지위치 오차누적 개선 방안 제안)

  • Lee, Jong-Hyun;Kwon, Soon-Wook;Park, Sung-Ung;Lee, Mi-Na
    • Korean Journal of Construction Engineering and Management
    • /
    • v.13 no.2
    • /
    • pp.110-119
    • /
    • 2012
  • The Plan and equipment of vertical lifting are very important in high-rise building construction site, and unmanned lifts usage is increasing for financial and efficient reason. However if lift stop position error occur, It can be accumulated. And the lift can not be available during an engineer fix the problem. So loss of time and cost will occur when lifts have problems. This paper reports an improved lift stop position sensing device for preventing loss of time and cost from lift stop position error. The result of tests showed that the system has a correction function of lift stop position error, and the accuracy of device which was developed in this paper was about 9.75mm better than existing equipment.

가공면의 상태 변화 측정에 관한 연구

  • Cho, Nam-Gyoo;Choi, Han-Kwang;Han, Chang-Soo;An, Yoo-Min;Park, Gyun-Myung
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.18 no.2
    • /
    • pp.54-62
    • /
    • 2001
  • This paper describes a new method for measuring the changes in specific surface asperities arising from processes such as finishing, coating, wear and corrosion. In repetitive measurements, relocation device gives the same position and orientation so that specific profile can be obtained. A low-cost relocation device is designed and its performance is assessed. The error in relocation process is compensated by statistic compensation algorithm. And, a removing process of cusp by grinding is observed by the proposed method.

  • PDF

Estimation and Validation of Longitudinal Stability/Control Derivatives for the Flight Training Device of a Light Aircraft

  • Lee, Jung Hoon
    • International Journal of Aerospace System Engineering
    • /
    • v.5 no.1
    • /
    • pp.9-18
    • /
    • 2018
  • The longitudinal flight parameters of a light airplane are estimated from flight test data by use of the output error method. The reliability of the flight test measurement is examined in engineering judgment, scatter and Cramer-Rao bound, which turns out to be satisfactory with minor defects. Estimated parameter values are validated by comparing the simulated responses with the ones from actual flight tests. The FTD(Flight Training Device) of a light airplane turns out to satisfy the qualification of FAA Level 5 FTD in longitudinal motion. All the necessary practices for generation of high-fidelity data in longitudinal motion of a light aircraft are successfully performed in this study.

Optical Proximity Corrections for Digital Micromirror Device-based Maskless Lithography

  • Hur, Jungyu;Seo, Manseung
    • Journal of the Optical Society of Korea
    • /
    • v.16 no.3
    • /
    • pp.221-227
    • /
    • 2012
  • We propose optical proximity corrections (OPCs) for digital micromirror device (DMD)-based maskless lithography. A pattern writing scheme is analyzed and a theoretical model for obtaining the dose distribution profile and resulting structure is derived. By using simulation based on this model we were able to reduce the edge placement error (EPE) between the design width and the critical dimension (CD) of a fabricated photoresist, which enables improvement of the CD. Moreover, by experiments carried out with the parameter derived from the writing scheme, we minimized the corner-rounding effect by controlling light transmission to the corners of a feature by modulating a DMD.

Failure Detection Filter for the Sensor and Actuator Failure in the Auto-Pilot System

  • Suh, Sang-Hyun
    • Journal of Hydrospace Technology
    • /
    • v.1 no.1
    • /
    • pp.75-88
    • /
    • 1995
  • Auto-Pilot System uses heading angle information via the position sensor and the rudder device to control the ship's direction. Most of the control logics are composed of the state estimation and control algorithms assuming that the measurement device and the actuator have no fault except the measurement noise. But such asumptions could bring the danger in real situation. For example, if the heading angle measuring device is out of order the control action based on those false position information could bring serious safety problem. In this study, the control system including improved method for processing the position information is applied to the Auto-Pilot System. To show the difference between general state estimator and F.D.F., BJDFs for the sensor and the actuator failure detection are designed and the performance are tested. And it is shown that bias error in sensor could be detected by state-augmented estimator. So the residual confined in the 2-dimension in the presence of the sensor failure could be unidirectional in output space and bias sensor error is much easier to be detected.

  • PDF

Comparison Measurement Error of T-score Between Lumbar and Femoral Neck According to Kind of DXA (DXA측정기 종류에 따른 요추부와 대퇴경부 골밀도 값의 측정오차 비교)

  • Han, Beom-Hee;Jung, Hong-Ryang;Lim, Cheong-Hwan;Lee, Hye-Nam;Jeong, Cheon-Soo;Lee, Sang-Ho
    • The Journal of the Korea Contents Association
    • /
    • v.10 no.3
    • /
    • pp.250-257
    • /
    • 2010
  • In this study, three different devices, Norland, Osteocore and Lunar were used to compare and analyze the measurement error by each bone density measurement device by classifying the physical characteristics into age, height and weight, the subject of total 300 sampling 100 persons for each device. Categorizing Lumbar region and Femoral neck as normal (T-score$\geqq$-1.0), osteopenia (-1.0>T-score>-2.5) and osteoporosis (T-score$\leqq$-2.5), the findings were observed as follows. Norland device showed the least measurement error in age and height, while Lunar showed the least in weight among the devices. And, the result of comparing the bone density measurement error based on the lumbar region showed that all of Lunar, Norland and Osteocore have the least variation of measurement error in osteopenia and the result of comparing based on the femoral neck showed that all of Lunar, Norland and Osteocore have the least variation of measurement error in osteoporosis. For each variable, the measurement error was observed to be vary upon the device. To solve this, standardized common Phantom should be used to compare and converge the measured value of each company and cross-calibration would be necessary when replacing the software.