• 제목/요약/키워드: Device Profile

검색결과 423건 처리시간 0.025초

CMS를 사용한 별색 교정에 관한 연구 (A Study on Spot Color Proofing using ICC-based Color Management System)

  • 정청숙;강상훈
    • 한국인쇄학회:학술대회논문집
    • /
    • 한국인쇄학회 2007년도 추계 학술논문 발표회
    • /
    • pp.65-73
    • /
    • 2007
  • The general commercial printing meets the customer's diverse demand by using spot color besides process four color. Especially, by using spot color for printing the enterprise's logo or specific color, we can see the effect of printing is getting better. The objective of this study was to examine the quality of spot color reproduction with Inkjet for 2 types of paper and Dye sublimation in ICC-based color management system. ICC profiles were generated for each device using ECI 2002 visual target and evaluated for the accuracy of each printer's color profile. The test chart consisting of Pantone color 1140 was selected to test the quality of spot color reproduction.

  • PDF

센서기반 에너지 모니터링 프로토타입 시스템 (Development of Sensor Based Energy Management System)

  • 엄대진;최중인;이인규
    • 조명전기설비학회논문지
    • /
    • 제28권10호
    • /
    • pp.69-74
    • /
    • 2014
  • With the increasing interest of energy efficiency, several buildings and factories begin to monitor energy usages with a built-in energy management system. However, the built-in energy monitoring system does not reflect the dynamics of buildings and factories energy usage. To overcome the latter, we deploy several sensors to monitor the dynamics of buildings energy usage patterns. In this paper, we are proposing a framework of a sensor based energy monitoring system. Based on our limited experiments, we can monitor power usages by a person, device and time period. As a result, we can plan a better energy usage and improve energy efficiency by the monitored energy usage profile data.

고주파 유전가열형 온열암치료기의 개발과 가온특성 (DEVELOPMENT and THERMAL DISTRIBUTION of an RF CAPACITIVE HYPERTHERMIA SYSTEM)

  • 박민용;이상배;박덕규;추성실;정미향
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1987년도 전기.전자공학 학술대회 논문집(II)
    • /
    • pp.1309-1312
    • /
    • 1987
  • Hyperthermia for the treatment of cancer has been introduced for a long time and the biological effect for the use of hyperthermia to malignant tumors has been well established and encouraging clinical results has been observed. Unfortunately, the engineering or technical aspects of hyperthermia for the deep seated tumors has not been satisfactory. We have researched and developed the radiofrequency capacitive hyperthermia system (GHT- RF8). It was composed with 8-9 MHZ RF generator, capacitive electrode, matching system, cooling system, temperature measuring system and control computer. The thermal profile was investigated in agar phantom, animals and in human tumors, which was heated with capacitive RF device.

  • PDF

Flavin-Viologen 복합 LB막으로 구성된 분자광다이오드에서의 광유도 전자전달 (Photoinduced Electron Transfer in Molecular Photodiode Consisted of Flavin-Viologen Hetero-LB Films)

  • 김민진;최정우;정성욱;오세용;이원흥;신동명
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 1995년도 추계학술대회 논문집
    • /
    • pp.281-284
    • /
    • 1995
  • A molecular photodiode was fabricated with hetero-Langmuir-Blodgett (LB) film consisting of an electron accepter(A) and sensitizer. N-Allyl-N-[3-propylamido-N\",N\"-야(n-octadecyl)]-4,4-bipyridum Dibromide and 7,8-dimethyl-10-dodecyl isoalloxan-zine were used as A and S units, respectively. By aligning hefter-LB film of A/S units on ITO glass with an aluminium thin film, a molecular photodiode with the structure of Metal/Insulator/Metal(MIM) was constructed. Due to excitation by irradiation with a 460nm monochromatic light source, the photo-induced unidirectional flow of electrons in the MIM device could be achieved and was detected as photocurrents. The direction of energy flow was in accordance with the energy level profile across the LB films. The photo switching function was achieved and the rectifying characteristics was obserbed in the molecular devise.

  • PDF

리소그라피 모의실험을 위한 전자빔용 감광막의 현상 변수 측정과 프로파일 분석 (Development parameter measurement and profile analysis of electron beam resist for lithography simulation)

  • 함영묵;이창범;서태원;전국진;조광섭
    • 전자공학회논문지A
    • /
    • 제33A권7호
    • /
    • pp.198-204
    • /
    • 1996
  • Electron beam lithography is one of the importnat technologies which can delineate deep submicron patterns. REcently, electron beam lithography is being applied in delineating the critical layers of semiconductor device fabrication. In this paper, we present a development simulation program for electron beam lithography and study the development profiles of resist when resist is exposed by the electron beam. Experimentally, the development parameter of positive and negative resists are measured and the data is applied to input parameter of the simulation program. Also simulation results are compared of the process results in the view of resist profiles. As a result, for PMMA and SAL 601 resist, the trend of simulation to the values of process parameters agree with real process results very well, so that the process results can be predicted by the simulation.

  • PDF

침의 한국산업규격(KS) 도입 필요성에 대한 고찰 (Need for Korean Industrial Standards (KS) for Acupuncture Needle)

  • 장인수;박종배;서정철
    • Journal of Acupuncture Research
    • /
    • 제21권5호
    • /
    • pp.149-162
    • /
    • 2004
  • Quality assurance with high safety profile is one of the most critical issues to medical device manufacturing. In general, this issue was not paid proper attention with respect to acupuncture needle and its related devices. Acupuncture needles are manufactured through various standards ranging from purely hand-made, partially hand-made and partially machine-made, to fully machine-made mainly in China, Korea, and Japan. There is a large difference in quality between needles from different manufacturers. In order to provide a standard manufacturing guideline, it seems necessary to make a Korean Industrial standard (KS). The authors review this topic from an historical view point, investigate the current situation of the standardization of acupuncture needles in other developed countries, and inspect the general procedure to establish a KS in Korea in order to suggest a KS for acupuncture needles.

  • PDF

형상기억합금 수치해석을 위한 특성 실험 및 작동기 응용 (Experimental Test Numerical Simulation of SMA Characteristics and Device verification)

  • 김상헌;최현호;조맹효
    • 한국복합재료학회:학술대회논문집
    • /
    • 한국복합재료학회 2005년도 추계학술발표대회 논문집
    • /
    • pp.145-148
    • /
    • 2005
  • In this study, adaptation of two-way shape memory effect of SMA wire to the actuator is examined . Therefore the SMA characteristics which are training, material properties, response time at different thermal cycling rates are tested. During training, permanent deformation is accumulated till a certain number of cycle and then saturated. The amow1t of two-way strain is unchangeable over all cycle and the slope of strain(or stress)-temperature curve is slower as the increase of applied stress. The rate effect is observed resulted from the thermal distribution which heating profile differs from cooling as thermal cycling time. Using the estimated SMA properties, an experimental test for the simple smart wing is performed.

  • PDF

비구면 초정밀절삭 공정기술에 관한 연구 (A study on Ultra Precision machining process for Aspheric)

  • 김건희;홍권희;김효식;김현배;양순철;윈종호
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2003년도 춘계학술대회 논문집
    • /
    • pp.90-93
    • /
    • 2003
  • This paper described about the ultra-precision profile measurement of aspheric surfaces using contact probing technique. A contact probe has been designed as a sensing device to obtain measuring resolutions in nanometer regime utilizing a circle leaf spring mechanism and a capacitive-type sensor. The, contact probe is attached on the z-axis during measurement while aspheric object are supported on the diamond turning machine(DTM). The machine xz-axis motions are monitored by a set of two orthogonal plane mirror type laser interferometers. Experimental results show that the contact probing technique developed of on-machine measurement system in this investigation is capable of providing a repeatability of 10 nanometers with a $\pm$20 uncertainty of 200nmPv.

  • PDF

칩 마운터용 리니어 모터 스테이지의 열저항 모델링 (Thermal Resistance Modeling of Linear Motor Driven Stages for Chip Mounter Applications)

  • 장창수;김종영;김영준
    • 대한기계학회논문집B
    • /
    • 제26권5호
    • /
    • pp.716-723
    • /
    • 2002
  • Heat transfer in linear motor driven stages for surface mounting device applications was investigated. A simple one-dimensional thermal resistance model (TRM) was introduced. In order to reduce three-dimensional nature to one-dimensional, a few assumptions and simplifications were employed suitably. A good agreement with a finite element heat transfer analysis in temperature profile was obtained. For validation, the analysis was compared with the measurement with respect to motor driving power. Overall discrepancy was less than 7$^{\circ}C$. The influence of two high thermal resistance parts, insulation sheet and thermal contact between the coil assembly and the mounting plate, was examined through the analysis. Additionally, the thermal resistance analysis was applied to another stage including an internal cooling-air passage, and was found available for this system as well. After validation, the cooling effect was surveyed in terms of motor power, and cooling-air and -water flow rate.

칩 마운터용 리니어 모터 스테이지의 열저항 모델링 (Thermal Resistance Modeling of Linear Motor Driven Stages for Chip Mounter Applications)

  • 장창수;김종영;김영준
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2001년도 추계학술대회논문집B
    • /
    • pp.96-101
    • /
    • 2001
  • Heat transfer in linear motor driven stages for surface mounting device applications was investigated. A simple one-dimensional thermal resistance model was introduced. In order to reduce three-dimensional nature to one-dimensional, a few assumptions and simplifications were employed suitably. A good agreement with a finite element heat transfer analysis in temperature profile was obtained. For validation, the analysis was compared with the measurement with respect to motor driving power. Overall discrepancy was less than $7^{\circ}C$. The influence of two high thermal resistance parts, insulation sheet and thermal contact between the coil assembly and the mounting plate, was examined through the analysis. Additionally, the thermal resistance analysis was applied to another stage including an internal cooling-air passage, and was found available for this system as well. After validation, the cooling effect was surveyed in terms of motor power, and cooling-air flow rate.

  • PDF