• Title/Summary/Keyword: Deterioration state

Search Result 363, Processing Time 0.023 seconds

Analysis on Material Characteristics of Restored Areas with Mortar and Basis of Surface Deterioration on the Stupa of State Preceptor Jigwang from Beopchensaji Temple Site in Wonju, Korea (원주 법천사지 지광국사탑 복원부 모르타르 재료학적 특징 및 표면손상 기초 해석)

  • Chae, Seung A;Cho, Ha Jin;Lee, Tae Jong
    • Journal of Conservation Science
    • /
    • v.37 no.5
    • /
    • pp.411-425
    • /
    • 2021
  • The Stupa of State Preceptor Jigwang from Beopcheonsa Temple Site in Wonju (National Treasure) is a representative stupa of the Goryeo Dynasty, with outstanding Buddhist carvings and splendid patterns, clearly indicating its honoree and year of construction. However, it was destroyed by bombing during the Korean War (1950-1953) and repaired and restored with cement and reinforcing bars in 1957. The surface condition of the original stone shows long-term deterioration due to the m ortar used in past restorations. In order to identify the exact causes of deterioration, the m ortar and surface contaminants on the original stone were analyzed. Portlandite, calcite, ettringite, and gypsum from the mortar were identified, and its ongoing deterioration was observed through pH measurements and the neutralization reaction test. Analysis of surface contaminants identified calcite and gypsum, both poorly water-soluble substances, and their growth in volume among rock-forming minerals was observed by microscopy. Based on those results, semi-quantitative analysis of Ca and S contents significantly influencing the formation of salt crystals was conducted using P-XRF to analyze the basis of surface deterioration, and cross-validation was performed by comparing the body stone affected by the mortar and the upper stylobate stone unaffected by the mortar. Results indicate that the elements are directly involved in the surface deterioration of the body stone.

Design of Fuzzy Inference-based Deterioration Diagnosis System through Different Image (차 영상을 통한 퍼지 추론 기반 열화 진단 시스템 설계)

  • Kim, Jong-Bum;Choi, Woo-Yong;Oh, Sung-Kwun;Kim, Young-Il
    • Journal of the Korean Institute of Intelligent Systems
    • /
    • v.25 no.1
    • /
    • pp.57-62
    • /
    • 2015
  • In this paper, we design fuzzy inference-based deterioration diagnosis system through different image for rapid as well as efficient diagnosis of electrical equipments. When the deterioration diagnosis of the electrical equipment starts, abnormal state of assigned area is detected by comparing with the temperature of the first normal state of the area. Deterioration state of detected area is diagnosed by using fuzzy inference algorithm. In the fuzzy inference algorithm, fuzzy rules are defined by If-then form and are described as look-up table. Both temperature and its ensuing variation are used as input variables. While triangular membership function is used for the fuzzy input variables of fuzzy rules, singleton membership function is used for the output variable of fuzzy rules. The final output is calculated by using the center of gravity of fuzzy inference method. Experimental data acquired from individual electrical equipments is used in order to evaluate the output performance of the proposed system.

Clarification the Current Situation of Deterioration and Its Causes of Modernization Heritage Built with Bricks in Japan: A Case Study of Long-Term Monitoring Investigation at Sarushima Battery, Yokosuka, Japan

  • Fukami, Risako;Matsui, Toshiya;Kawamoto, Mayumi
    • Journal of Conservation Science
    • /
    • v.38 no.4
    • /
    • pp.265-276
    • /
    • 2022
  • A long-term monitoring investigation at Sarushima Battery (Kanagawa, Japan), which is one of the modernization heritages was conducted from 2017.06 to 2020.12. The investigation of the temperature and relative humidity (RH), measurement of the amount of brick decay, and X-ray diffraction analysis of the brick decay was conducted to understand in detail the environment in which the historical brick structure, the state of deterioration, identify the factors of deterioration. Furthermore, it was discussed whether the suitability of these investigation methods for assessing the status, identifying the level of deterioration and the factors that led to deterioration at the historical brick heritages. It was found that the brick deterioration at the site progressed especially in two periods: in April, and from June to August. These periods coincided with the period when the RH inside the structure decreased, and the Toyo-gumi bricks were in the process of absorbing moisture. Several different types of salts were detected in brick decay, especially thenardite, which is considered highly hazardous and destructive during periods when the amount of brick decay increased. Therefore, the RH in the structure and the salts present in the bricks were identified as one of the factors in the deterioration of the bricks at the site. The methods used in this study are appropriate as the initial survey methods for investigating the current conditions and identifying the causes of deterioration because it is possible to understand the environment within the modernization heritages, grasp the details of deterioration progression, and identify the characteristics of deterioration progression and its factors through long-term investigation using the simple methods.

Influence of the deteriorated anti-seismic devices on seismic performance and device behavior of continuous girder bridges

  • Shangtao Hu;Renkang Hu;Menggang Yang;Dongliang Meng
    • Earthquakes and Structures
    • /
    • v.24 no.5
    • /
    • pp.333-343
    • /
    • 2023
  • Various seismic isolation and reduction devices have been applied to suppress the longitudinal vibration of continuous girder bridges. As representative devices, lead rubber bearing (LRB) and fluid viscous damper (FVD) might suffer from deterioration during the long-term service. This study aims to evaluate the impact of device deterioration on the seismic responses of continuous girder bridges and investigate the seismic behavior of deteriorated LRBs and FVDs. Seismic performance of a simplified bridge model was investigated, and the influence of device deterioration was evaluated by the coefficient of variation method. The contribution of LRB and FVD was assessed by the Sobol global sensitivity analysis method. Finally, the seismic behaviors of deteriorated LRBs and FVDs were discussed. The result shows that (i) the girder-pier relative displacement is the most sensitive to the changes in the deterioration level, (ii) the deterioration of FVD has a greater effect on the structural responses than that of LRB, (iii) FVD plays a major role in energy dissipation with a low degradation level while LRB is more essential in dissipating energy when suffering from high degradation level, (iv) the deteriorated devices are more likely to reach the ultimate state and thus be damaged.

Reliability-Based Crack Damage Assessment of Reinforced Concrete Bridges (신뢰성에 기초한 콘크리트교량의 균열손상평가)

  • 조효남;최영민;임종권;옥승범
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1995.10a
    • /
    • pp.334-338
    • /
    • 1995
  • In recent years, the prediction of the deterioration rate of concrete structures has become major research interest. However, there are still many uncertain factors in the deterioration process and the relation between deterioration and durability of structures. This is mainly due to various uncertainties involved in the construction process and the environmental conditions which affect the rate of deterioration of concrete structures. In this study a limit state model in terms of random crack width due to applied dead and live loads is proposed for the assessment of crack damage of reinforced concrete structures. The AFOSM reliability method is used for the reliability evaluation of the crack durability of concrete bridges. The proposed model for crack durability of concrete bridges is applied to the Seoul interior circuit elevated expressway. The sensitivity analyses are performed for the proposed model.

  • PDF

State of Visual Acuity Test and Factors Related to Vision Deterioration of Preschoolers (미취학 아동의 시력검진 실태와 시력저하 관련요인)

  • Lee, Sunghwa;Lee, Haejung
    • The Journal of the Korea Contents Association
    • /
    • v.16 no.12
    • /
    • pp.132-142
    • /
    • 2016
  • The study aimed to examine the state of visual acuity tests in preschoolers and determine the factors affecting the deterioration of their vision. A total of 172 pair, child aged 5-7 years and either one of their parents, were recruited from childcare centers or kindergarten between August 2015 and January 2016. Questionnaires were administered to the parents, and the children's visual acuities were measured. Using forward selection in logistics regression analysis, factors affecting vision deterioration were elucidated. Of 172 children, 128 (74.4%) had undergone a visual acuity test previously and 77 (44.8%) showed a deterioration in their vision. Children who had undergone their first visual acuity test after the age of 7 years (OR=7.425, CI=2.844- 19.385) and showed more abnormal eye symptoms, such as squinting or tilting the head to see or falling down frequently (OR=3.084, CI=1.202-7.914) and whose age was younger (OR=10.335, CI=3.252-32.848), were more likely to develop deterioration of vision. Children who had a posture such that they looked up at the computer monitor from below (OR=.075, CI=.022-.255), were less likely to show deterioration of vision. It can be inferred that early visual acuity tests is essential to detect deteriorated vision of preschoolers. Therefore, it is necessary to educate parents, personnels in day care center, and health clinics about the importance of early visual acuity tests and close observation of specific behaviors related to vision deterioration. Development of precautionary intervention program of vision deterioration in preschoolers and examination of its effects are needed.

A Development of the High Precise Measuring Device and Methods of Resistive Leakage Current for the Deterioration Diagnosis of ZnO Arrester (산화아연 피뢰기의 열화진단을 위한 저항성누설전류의 고정도 측정기법 및 장치의 개발)

  • Lee, B.H.;Kang, S.M.;Jeon, D.K.;Park, K.Y.;Choi, H.S.;Cho, S.C.;Baek, Y.H.;Lee, D.H.
    • Proceedings of the KIEE Conference
    • /
    • 2003.07c
    • /
    • pp.1668-1670
    • /
    • 2003
  • This paper deals with a development of the high precise measuring device of resistive leakage current for the deterioration and diagnosis of ZnO arresters. The resistive leakage current increasing with time leads to a thermally unstable state that may even experience a disaster. So, the resistive leakage current can be used as an indicator to discriminate whether the ZnO arrester blocks is in good state or in bad. The resistive leakage current measuring system with an analysis program operated with micro-processor using the time delay addition method was designed and fabricated. The proposed measuring systems for the resistive leakage current can effectively be used to develop the techniques of forecasting the deterioration of ZnO arresters in electric power systems.⨀ᔌ?؀㔳㤮㈻Ԁ䭃䑎䷗ᜒं6〰Ԁ䭃䑎䴀

  • PDF

DTS-based Temperature Monitoring and Analysis of Battery Cell Deterioration Characteristics by Temperature Condition (DTS 기반 온도 감시 및 온도 조건에서의 배터리 셀 열화 특성 분석)

  • SoonJong, Kwon;Soo-Yeon, Kim;Jin, Hwang;Sang-Kyun, Woo;Bong-Suck, Kim
    • KEPCO Journal on Electric Power and Energy
    • /
    • v.8 no.2
    • /
    • pp.143-149
    • /
    • 2022
  • As ESS safety issues increase recently, there is a need to more precisely monitor the temperature of the ESS. In this paper, DTS technology for temperature monitoring of ESS batteries is introduced and the temperature measurement principle is explained. The temperature of the battery module is measured using the DTS system, and the thermal deviation between battery cells inside the battery module is analyzed. In order to analyze how thermal imbalance affects the charging and discharging performance of the battery, an accelerated degradation test was conducted. Cycle life characteristics analysis, battery surface temperature change, and AC impedance characteristics were conducted to analyze how the performance of battery cells differs according to temperature conditions.