• Title/Summary/Keyword: Deterioration facilities

Search Result 255, Processing Time 0.028 seconds

A Study On the Corrosion Tendency of Bottom Plates and Corrosion Prevention Measures in Hazmat Tanks (위험물저장탱코밑판의 부식 성향분석 및 부식예방 방안에 관한 연구)

  • Choi, Jeong Soo;Ro, Kyung Jin
    • Journal of the Society of Disaster Information
    • /
    • v.4 no.1
    • /
    • pp.138-152
    • /
    • 2008
  • The most important factor in the maintenance of chemical industry facilities is related with deterioration and corrosion. Leakage of hazardous materials is likely to occur because the confirmation and maintenance of bottom plates are very difficult while the bottom corrosion of the massive hazmat-storage facilities is most dangerous especially. As a result of the analysis of the corrosion locations, areas, usage condition of 287 hazmat-storage tanks on this syudy, it is concluded that the main external corrosion factors are the inflow of moisture and the materials inducing corrosion in the air such as sodium chloride and the main internal corrosion factors are corrosion react caused by stay of seawater, sulfur and moisture in hazmat for a long time without appropriate discharges. It is anticipated that the corrosion of bottom plates can be restrained effectively by establishing the proper measures for the each corrosion cause.

  • PDF

A study about the public library users, cognition degree for librarians (공공도서관 이용자들의 사서인식도에 관한 연구)

  • 임동빈
    • Journal of Korean Library and Information Science Society
    • /
    • v.24
    • /
    • pp.275-300
    • /
    • 1996
  • The writer obtained a Conclusion through this thesis as follows: First : There a n.0, ppeared that users, Cognition degree for librarian's Social status is very high. As it were, response for questioning about librarian's scholarly attainments and business type is almost accurate that we anticipate the expectation value for the librarian is very high. Second : The satisfaction degree of information services acquired by the users through public library was very skeptic. Due to the poorness of information media that we wish, and deterioration of data, it losed its qualification as a creation organization for the true information, but lots of people emphasized their opinion it only role as a "study room". Third : A questioning about librarian"s assiduity in the public library, there are lots of users Complain. Main factor of that dissatisfaction is Unkindness, and business like(duplicated) assiduity. Not only this but main desire to the public library in pusan down town by the users is also a n.0, ppeared as Kind Service. Fourth : General Controversial points in public libraries in pusan area indicated by the users who responded to the subjective questions are poor data, lack of kind service attitude and poor facilities.oor facilities.

  • PDF

An Experimental Study on the Engineering Properties of Concrete Spread with Liquefied Antibiotics (액상 항균제를 도포한 하수시설용 콘크리트의 공학적 특성에 관한 실험적 연구)

  • Lee Eui-Bae;Kim Yong-Duk;Cho Bong-Suk;Kim Jae-Hwan;Khil Bae-Su;Kim Moo-Han
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2005.05b
    • /
    • pp.233-236
    • /
    • 2005
  • Sewage facilities are positively necessary for environment improvement such as rainwater removal, sewage disposal, preservation of the quality of water and health of the citizens in present-day. Meanwhile, a deterioration of the concrete sewer facilities is increasing rapidly due to the chemical and physical attack and especially biochemical attack that is to say biodeterioration. In this study, to prevent biochemical corrosion of the sewer concrete, surface of the concrete was spread with liquefied organic and inorganic complex antibiotics and then its engineering properties were experimentally investigated

  • PDF

A study on the Analysis of Actual Condition of Residental Environment for the Eldery Residing in Daejeon (대전시 노인의 거주환경실태 조사연구)

  • 박정아;이지숙
    • Journal of the Korean housing association
    • /
    • v.15 no.1
    • /
    • pp.175-183
    • /
    • 2004
  • The purpose of this study was to identify the actual condition of residential environment for the elderly residing in Daejeon. The data were collected through interviews and structured questionnaires. The sujects were 583 elderly people over the age of 65 in Daejeon. Sociodemographic characteristics, living characteristics, housing characteristics, neighborhood environment types, actual usage condition of neighborhood environment, relationship between sociodemographic characteristics and actual usage of neighborhood environment, actual condition of unit interior, were surveyed. The data were analyzed with frequency, percentage, χ²-test, mean using the SPSS package. The major findings were as follows. Features of unit interior which pointed generally were deterioration, soundproofing and size. Features of unit interior which need to be carefully planned were removal of height difference of entrance, removal of the thresholds, installation of emergency bell and room heating control facility. The facilities provided highly within the subject's residential environment were the eldery facility, church, hospital, bank, restaurant, beauty salon/barbershop, supermarket. and the facilities provided lowly were recreational facility, library, elderly school.

Comparison of the Poor Insulator Detecting Technique for the Reliability Enhancement of the Electric Power Facilities (전력설비의 신뢰성 향상을 위한 불량애자검출기법의 비교)

  • Jung, Soon-Won;Koo, Kyung-Wan
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.57 no.4
    • /
    • pp.417-423
    • /
    • 2008
  • For the evaluation in the safety of outdoor insulator, there are various methods such as: visual observation; voltage measurement; use of ultrasonic wave due to partial discharge; electric field measurement; use of infrared/ultraviolet sensor-type camera. However, many problems have been issued regrading the reliability of the evaluation test and safety of testing operation. Accordingly, the present study has investigated and analyzed the characteristics and mechanisms of the insulator deterioration, in order to obtain an optimal method for detecting poor insulator so that the reliability of power facilities can be enhanced. Besides, based on theoretical analysis of domestic and international detection methods for poor insulator, the reliability has been compared and evaluated quantitatively. As a result, it was shown that the corona camera would be the best choice for domestic workplace application in detecting poor insulator for enhancing the reliability of power transmission line.

A study on the application of TALK-BACK system in a radio communication environment (토크백 시스템 무선통신 적용방안 연구)

  • Yeo, Yong-Joo;Yoon, In-Young;Nam, Joung-In;Choi, Yoon-Seog
    • Proceedings of the KSR Conference
    • /
    • 2008.11b
    • /
    • pp.1294-1302
    • /
    • 2008
  • Talk-Back systems comprised of master-equipment at the control room and slave-equipment at turnouts refer to the intercommunication facilities that optimize mutual communication between maintenance staff on trackside and the control room to facilitate quickness and accuracy of train operation control and its maintenance within depot and on mainlines with turnouts for direction switching of the trains in operation. The weakness lies in additional maintenance costs of cables since the Talk-Back system installed on line 1 along with line 2-4 has a profound effect on the voice quality leading to the attenuation and crosstalk of the system due to the deterioration of cables and environmental factors. This paper discusses the Talk-Back system in a radio communication environment with the application of RF(Radio Frequency) communication system from the wire communication system by cables to ameliorate these problems, and deals with the energy saving environmentally friendly facilities in consideration of replacing power section at salve-equipment with solar batteries benefitting the system in light of energy consumption.

  • PDF

Evaluation criteria for freezing and thawing of tunnel concrete lining according to theoretical and experimental analysis

  • Moon, Joon-Shik;An, Jai-Wook;Kim, Hong-Kyoon;Lee, Jong-Gun;Lattner, Tim
    • Geomechanics and Engineering
    • /
    • v.29 no.3
    • /
    • pp.349-357
    • /
    • 2022
  • Abnormal climate events are occurring frequently around the world. In particular, cold waves and heavy snow lead to damage and deterioration of facilities, which can cause loss of life or property damage, such as shortening the lifespan of facilities. Therefore, it is very important to prepare an appropriate maintenance system and to establish a strategy to cope with abnormal weather conditions. In this study, laboratory freezing experiments were performed to analyze the freeze-thaw characteristics affecting the tunnel concrete lining, and heat flow analysis was carried out based on the test results. Based on these experimental and theoretical analysis results, quantitative freeze-thaw evaluation criteria for tunnel concrete linings were proposed.

Maintenance Priority Determination Method considering the Shape and Property Information of Roads and Pipe Networks (도로, 관망의 형상 및 속성정보를 고려한 유지보수 우선순위 결정 방법)

  • Jang, Young-Hoon;Park, Wonyoung
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2023.05a
    • /
    • pp.279-280
    • /
    • 2023
  • Due to the deterioration of infrastructure, the importance of maintenance is continuously increasing. Therefore, an integrated maintenance method for various facilities is required. In this study, a maintenance priority determination method for integrated maintenance of roads and pipe network facilities was developed. It is possible to analyze attribute information by using GIS data of roads and pipe networks, and shape information can be used. This information is derived as quantitative figures for determining maintenance priorities. In the future, it is expected that facility maintenance can be further advanced in connection with maintenance method and quantity information for each facility.

  • PDF

A Study on Economic Analysis of Development of On-line Diagnosis Technique for Preventing Electrical Accidents (전기설비사고예방을 위한 온라인진단기술 개발의 경제성 분석)

  • Kim, Han-Sang;Kim, Kwang-Ho
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.63 no.2
    • /
    • pp.313-318
    • /
    • 2014
  • In the last couple of decades industrialization and technological development has not only increase in the scale of electrical facilities and it has become more and more complicated and diversified. Furthermore, fires in the electrical transformers, like those that have knocked out power in the country in the past years, are likely to become more common as utility systems begin to show their age. The importance of preventing electrical accidents can never be overemphasized and for this reason, supply of on-line diagnosis system combining information and communication technology(ICT) for the customer's electrical facilities has been increasing recently. The major advantage of on-line diagnosis system is that the device's potential problems could be detected early before a serious deterioration or breakdown occurs. In this paper, We estimated the benefit from the investment in the right of present value of sales, success rate of commercialization regarding R&D investment for development and commercialization of on-line diagnosis technology targeting customer electrical facilities. As a result, the net value added of 29.7 billion won and the increased profit by roughly 7.52 precent are expected.

The UV Images and Aging Judgement with Behaviors Caused by Surface Contamination on 22.9[kV] Class Insulators (22.9[kV]급 애자의 표면오염에 의한 자외선 영상과 열화판정)

  • Shong, Kil-Mok;Kim, Young-Seok
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.24 no.1
    • /
    • pp.167-174
    • /
    • 2010
  • In this paper, the ultraviolet rays images and aging judgement caused by surface contamination on 22.9[kV] class insulators was defined. UV images represented by the corona discharge are divided 3 types such as sunflower, jellyfish, amoeba and in detail, there are classified the progress mechanism of eight. In the field which is installed the power facilities, immediately, this judgement method can be found out the deteriorated parts of the power facilities. These steps are possible to judge the deterioration of power facilities through reliable data. Hereafter, this study as the diagnostic technology suitable for the sites is used.