• Title/Summary/Keyword: Deterioration facilities

Search Result 255, Processing Time 0.034 seconds

A Study on Cable Lifetime Evaluation Based on Characteristic Analysis of Insulation Resistance by Acceleration Factor of the Arrhenius Equation (아레니우스 방정식의 가속인자를 만족하는 절연저항특성 분석에 의한 케이블 수명평가 연구)

  • Um, Kee-Hong;Lee, Kwan-Woo
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.14 no.5
    • /
    • pp.231-236
    • /
    • 2014
  • With the development of industry these days, the demand for electric power increases and the larger capacity for power transfer is required. The scales of facilities should become larger; and the relative systems are required to operate with a higher degree of reliability. Therefore, stabilization of electric power systems is an important issue. The high degree of reliability required in the process of production and supply of electric power is an essential part of industrial society. Accident such as blackouts causes a hugh amount of economic losses to the high-tech industrial society dependent upon electric power. In this paper, in order to determine a stable operation of high-voltage power cable, used as a unique means of delivering electric power generated at a power station, we figure out the time rate of change of insulation resistance following a decay accelerating factor Arrhenius equation. With the data from the insulation resistance, we can determine the lifetime of power cable in operation.

A Study on Airborne Dust and Asbestos Concentrations in Subway Stations in Seoul Area (서울시 지하철 구내의 공기중 분진 농도에 관한 연구)

  • 백남원;박두용;장익선;신용철;이정인
    • Journal of Environmental Health Sciences
    • /
    • v.14 no.2
    • /
    • pp.1-12
    • /
    • 1988
  • Airborne dust and asbestos fiber concentrations were determined in subway stations located in Seoul area. Two stations, such as Eulchiro 4-Ka Station of Line #2, constructed during a period of 1980-1984 and Hyehwa Station of Line #4, opened in 1985, were selected. The results of the study are as follows. 1. Daily time-weighted average (TWA) concentrations of airborne dusts from 07:00 to 20:00 hours in Line #2 and Line #4 were 0.43$\pm$0.08 mg/m$^3$ and 0.37$\pm$0.12 mg/m$^3$, respectively. Thus, the dust levels in Line #2 were significantly higher than the levels in Line #4 (p < 0.05). 2. Dust levels in the morning (07:00-11:00 hours), noon (11:00-16:00 hours) and in the evening (16:00-20:00 hours) in Line #2 were 0.47$\pm$0.17 mg/m$^3$, 0.37$\pm$0.08 mg/m$^3$, and 0.46$\pm$0.07 mg/m$^3$ respectively. Thus, dust levels in the morning and evening (i.e., during rush hours) were significantly higher than levels in the noon (p < 0.02). However, there was no such difference in dust levels by time in Line #4. 3. Airborne total dust concentrations were well below the occupational health standard of 10 mg/m$^3$, however, the levels were exceeding the ambient air standard recommended by the Korean Environment Administration. 4. All of airborne asbestos fiber concentrations were equal to or below 0.005 fibers/cc. The levels are within both occupational health standards and U.S. EPA criteria. 5. A consideration should be given to the improvements of cleaning methods (such as use of vacuum cleaning instead of brushing) and the existing ventilation (such as more air change and filtration of supply air) for a reduction of dust levels. 6. It is recommended that routine monitoring of airborne dusts and asbestos fibers be conducted because more dusts and asbestos fibers can be produced in the air due to the deterioration of facilities by age and water damage in future.

  • PDF

Analysis of Radio Distortion in Navigational Aid using Drone (드론을 이용한 항행안전시설 전파왜곡 분석)

  • Lee, Young-gil;Lee, Hyeon-sung
    • Journal of Advanced Navigation Technology
    • /
    • v.23 no.6
    • /
    • pp.522-525
    • /
    • 2019
  • To overcome the limitation of ground inspection for Navigational Aid, Korea Airport Corporation (KAC) developed a drone system for Navigational Aid inspection. This drone system has the advantage that they can inspect the air radio signal at the perspective of user (aircraft). Since drones have more free flight paths and easier control of flight speeds compared to aircrafts, drones can check sections of suspected airborne radio wave distortions at desired paths and speeds. Recently, with the acceleration of the development around the airport, there is a concern about the deterioration of the quality of radio signal of Navigational Aid. In order to analyze radio distortion of Navigational Aid, a radio wave environmental survey was conducted using drones. When the signal received by each flight path of the drone was measured, the origin of the reflected wave was identified by analyzing the section in which the radio signal was distorted.

Sustainable Utilization and Management Scheme in Wangdol-cho Surrounding Sea Area (동해 왕돌초 어장의 지속적 이용 및 관리 방안)

  • Lee, Kwang-Nam;Myoung, Jung-Goo
    • Ocean and Polar Research
    • /
    • v.25 no.3
    • /
    • pp.331-345
    • /
    • 2003
  • The fishing ground surrounding Wangdol-cho is not only overexploited by the littering of dilapidated fishing net and equipment, but also by fishermen's overfishing, surpassing optimum fisheries resources. In addition, increasing fishing efforts (number of fishing vessel and fishing net, etc) contribute to the deterioration of fishing ground, and it is urgently required that schemes to tackle the problems should be taken. To effectively address the problems as such, this paper aims to propose sustainable utilization and management scheme of fishing ground through classification of fishing ground surrounding Wangdol-cho as one area which is less than 50m deep, measuring $13.66km^2$ and the other, permission fishing area of Gill Net fishery, measuring $347.23km^2$. The analysis shows that, for the water area less than 50m deep, implementation from a short-term perspective includes autonomous management fishery by gill net and trap fishery. For the permission fishing area of Gill Net fishery, implementation includes limit on fishing period, real name system of fishing equipment and limit on fishing equipment. Implementation from a medium and long-term perspective includes limit on scuba diving, designation of underwater sightseeing zone, sea farming, facilities of surveillance, adoption of approval system for the permission fishing area of Gill Net fishery and introduction of report system for fishing.

Efficient Methods for Road Sign Database Construction (도로표지의 효율적인 데이터베이스 구축방안)

  • Kim, Eui-Myoung;Cho, Du-Young;Chong, Kyu-Soo;Kim, Seong-Hoon
    • Journal of Korean Society for Geospatial Information Science
    • /
    • v.19 no.3
    • /
    • pp.91-98
    • /
    • 2011
  • Road signs are part of the traffic facilities intended to guide drivers to their destinations in a safe and comfortable manner. Due to the creation of new routes, changes to the old routes, and the deterioration of road signs, road signs do require efforts to do ongoing field investigations and put the results in a database. The purpose of this study was to propose methodologies to do field investigations and build a database for road signs efficiently. For that purpose, a mobile mapping system was designed for field investigations. The designed mobile mapping system was comprised of three cameras to produce image information about road signs, GPS/IMU/DMI to obtain information about the position and attitude of a vehicle, and a laser scanner to generate information about the locations of road signs and routes. Also proposed in the study was a procedure to automatically detect the areas of road signs in the road signs images and recognize their characters.

A Study on the Construction of IoT based System for District Heating Customer-side Energy Efficiency Management (지역난방 수용가측 효율관리를 위한 IoT 기반 시스템 구축에 관한 연구)

  • Yun, Jungmee;Lee, Sanghak;Ahn, Changkoo;Eom, Jaesik
    • Journal of Energy Engineering
    • /
    • v.26 no.3
    • /
    • pp.113-122
    • /
    • 2017
  • The district heating system, which is the main axis of Korea's collective energy business, contributes to the national benefit and safety with the economical heat energy supply system.However, due to the uncertainty of management subjects and the shortage of professional technical personnel, there are many problems such as deterioration of thermal efficiency and unfairness of the price of the apartment houses. In this paper, we propose the monitoring points necessary for the efficiency and fault management of the district heating customer-side. And we propose a standard reference model to standardize it. We propose a technical methodology to improve the service quality and energy efficiency of the district heating facilities by applying IoT sensor technology, real-time monitoring and integrated management system.

Experimental Study on Evaluation of Bond Strength after Ozone Treatment and Ozone Resistance of Concrete Metal Spray Coating for Advanced Water Treatment (고도정수처리용 콘크리트 금속용사 피막의 내오존성 및 오존처리 후 부착강도 평가에 관한 실험적 연구)

  • Park, Jin-Ho;Jang, Hyun-O;Lee, Han-Seung
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.22 no.4
    • /
    • pp.68-75
    • /
    • 2018
  • The introduction of advanced water treatment facilities has increased as the conventional purification method cannot remove the substance clearly. However, the internal waterproofing and Anticorrosion materials of the advanced water treatment facility using ozone deteriorate due to the oxidation power of ozone and affects the concrete, which causes a decrease in durability. This study is to evaluate the ozone resistance according to the type of spray metal and the surface treatment method of the coating, and the bond strength after ozone treatment in order to develope a finishing method to prevent deterioration of concrete structure of water treatment facility using metal spraying method as a way to construct metal panel with excellent ozone resistance and chemical resistance by an easier way than the previous. The Experimental results show that spray metal Ti has superior ozone resistance even after spraying. It is considered to be the most suitable method for ozone resistance and bond performance by finishing using Teflon sealing as surface treatment method.

NELL2 Function in Axon Development of Hippocampal Neurons

  • Kim, Han Rae;Kim, Dong Hee;An, Ji Young;Kang, Dasol;Park, Jeong Woo;Hwang, Eun Mi;Seo, Eun Jin;Jang, Il Ho;Ha, Chang Man;Lee, Byung Ju
    • Molecules and Cells
    • /
    • v.43 no.6
    • /
    • pp.581-589
    • /
    • 2020
  • Neurons have multiple dendrites and single axon. This neuronal polarity is gradually established during early processes of neuronal differentiation: generation of multiple neurites (stages 1-2); differentiation (stage 3) and maturation (stages 4-5) of an axon and dendrites. In this study, we demonstrated that the neuron-specific n-glycosylated protein NELL2 is important for neuronal polarization and axon growth using cultured rat embryonic hippocampal neurons. Endogenous NELL2 expression was gradually increased in parallel with the progression of developmental stages of hippocampal neurons, and overexpression of NELL2 stimulated neuronal polarization and axon growth. In line with these results, knockdown of NELL2 expression resulted in deterioration of neuronal development, including inhibition of neuronal development progression, decreased axon growth and increased axon branching. Inhibitor against extracellular signal-regulated kinase (ERK) dramatically inhibited NELL2-induced progression of neuronal development and axon growth. These results suggest that NELL2 is an important regulator for the morphological development for neuronal polarization and axon growth.

Visitors' Behavioral Characteristics and Attitudes to the Use and Managerial Attributes in Hallasan National Park, Korea (한라산국립공원에서의 탐방객 이용행태와 이용.관리속성에 대한 태도)

  • Yoo, Ki-Joon;Baek, Jae-Bong;Kim, Sun-Hee
    • Korean Journal of Environment and Ecology
    • /
    • v.21 no.2
    • /
    • pp.126-133
    • /
    • 2007
  • This study was designed to provide basic visiter information for establishing effective park management strategies. A questionnaire survey was at major entry points in Hallasan National Park(Eorimok and Youngsil). 237 random samples among the visitors on the way back home from their visit were chosen to represent general visitor population. As for the results, visitors' recreational satisfaction level with the area was relatively high. The majority of the visitors were satisfied with 20 uses and management related attributes provided by Hallasan National Park system. However, considering lack of sense of hygienic sanitary facilities, consequential deterioration of natural and cultural resources, and entrance fees as well as other costs, there needs to be a managerial priority on visiter service.

A Study on the Improvement of Maintenance for Public Library (공공도서관 유지관리의 문제점 및 개선방안에 관한 연구)

  • Choi, Hong-Seok;Oh, Kyung-Taek;Lee, Chan-Sik
    • Proceedings of the Korean Institute Of Construction Engineering and Management
    • /
    • 2008.11a
    • /
    • pp.859-862
    • /
    • 2008
  • As a research of NSO(Korea National Statistical Office), there are 609 public libraries in Korea. They have been increased 1.6 times for 10 years. Similar as libraries, their government officers are also increased 1.3 times. But number of users are increased 2.7times during the same period. Moreover, Because of deterioration of facilities, library can't satisfy user's needs, and it experienced difficulties to carry out its variety roles. In result, this study checked up maintenance conditions which are organization, facility, execution of budget and so on. Furthermore, it deduced problems like short of hands, lack of administrator's expertise and absence of accurate drawings, and suggests improvement.

  • PDF