Comparison of Analysis Methods for Ammonia from Swine Production Facilities

  • Kim, Ki Y.;Choi, Hong L.;Kim, Chi N.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • 제17권11호
    • /
    • pp.1608-1614
    • /
    • 2004
  • This study was performed to evaluate the accuracy, validation and applicability of UV spectrophotometer (UV), Ion Chromatography (IC), and Detector tube (DT) methods for measuring ammonia (NH3) concentration in a swine confinement house and swine slurry storage tank. The mean values of $NH_{3}$ emitted from the house and slurry were 5.333 ppm and 42.192 ppm for the IC method; 4.13 ppm and 36.29 ppm for the Detector tube; and 5.417 ppm and 34.193 ppm for the UV method. The accuracy and the correlation of an ammonia level analyzed by the IC method compared to the UV method were 98% and 0.998($R^{2}$) in the swine confinement house and 94% and 0.997($R^{2}$) in the swine slurry storage tank. On the other hand, those of ammonia level measured by the Detector tube compared to the UV method were 77% and 0.957($R^{2}$) in the swine confinement house and 82% and 0.941($R^{2}$) in the swine slurry storage tank. This indicated that the accuracy and the correlation of the IC method compared to the UV method were higher than those of the Detector tube method compared to the UV method. Therefore, it was concluded that the IC method was more accurate in measuring ammonia concentration in a swine house and a swine slurry storage tank. The Detector tube method should not be applied to the swine slurry storage tank in which ammonia concentration is generally higher than 30 ppm because low accuracy is caused by a gross space between scales inscribed in the Detector tube.

GM Tube 및 NaI(TI) 검출기를 사용한 Wide-Range 방사선 측정 시스템의 설계 (Design of Wide-Range radiation measurement system using GM Tube and NaI(TI) Detector)

  • 라승탁;이주현;이승호
    • 전기전자학회논문지
    • /
    • 제21권2호
    • /
    • pp.146-149
    • /
    • 2017
  • 본 논문에서는 GM Tube 및 NaI(TI) 검출기를 사용한 Wide-Range 방사선 측정 시스템을 제안한다. 제안하는 시스템은 NaI(Tl) 검출기 및 GM Tube의 검출기 신호를 제어, 계수할 수 있게 최적화한 하나의 소형 모듈로 설계한 다. 방사선량은 2개의 검출기를 연동하여 Wide-range인 0.1uSv/h~10mSv/h 구간에서 측정되고, 측정구간이 중복되는 지점인 10uSv/h~100uSv/h에서는 2개의 검출기가 동시에 동작한다. 방사선량은 중첩된 방사선 측정 가능 구간에 대해 적정한 구간에서 해당 검출기 기능의 On/Off를 제어하는 Wide-Range 방사선 측정 알고리즘을 이용하여 선택 적용하였다. 제안된 시스템의 성능을 평가하기 위하여 공인시험기관에서 실험한 결과, 각 구간별로 측정 불확도가 ${\pm}7.5%$로 측정되어 국제 표준인 ${\pm}15%$ 이하에서 정상동작 됨이 확인되었다.

FID를 이용한 수중의 TOC 분석법 (Determination of Total Organic Carbon in Water by Flame Ionization Detector)

  • 박만기;한대석;임병연
    • 약학회지
    • /
    • 제22권3호
    • /
    • pp.157-162
    • /
    • 1978
  • Total organic carbon(TOC) can be determined by means of combustion and flame ionization detector. The principle of string method is that a sample acidified to pH2 and transferred into combustion tube by string is oxidized with air. Another combustion tube method is that organic compounds are oxidized in the combustion tube charged with CuO and cobalt asbestos after the acidified sample is injected directly by microsyringe. Carbon dioxide evolved was reduced under specially treated nickel catalyst and hydrogen, the methane produced was detected by flame ionization detector. Linear relationship was found between concentration and the peak height by the string method. The peak area in the case of combustion tube method is in the range of 1-200ppm. The coefficient of variation by string method was 2.3% and that by combustion tube method was 1.8%. The lower detectable limit was about 10mol. Advantages of the latter are simplicity, sensitivity and reproducibility. TOC in contineous stream can also be determined automatically by means of the string method.

  • PDF

DR(Digital Radiography)에서 관전압 및 자동노출제어장치의 감도 변화에 따른 검출기의 동적 범위 성능평가 방법연구 -Dynamic Step Wedge와 히스토그램 평가를 중심으로 (A Study on the Dynamic Range Performance Evaluation Method of Detector with Variation of Tube Voltage and Automatic Exposure Control (AEC) in Digital Radiography (DR) -Focused on the Dynamic Step Wedge and Histogram Evaluation)

  • 황준호;최지안;김현수;이경배
    • 한국콘텐츠학회논문지
    • /
    • 제19권4호
    • /
    • pp.368-380
    • /
    • 2019
  • 본 연구는 자동노출제어장치 사용 시 관전압과 감도 변화에 따른 dynamic step wedge와 히스토그램의 동적 범위 분석을 통해 검출기의 성능을 평가하는 방법을 제안하고자 하였다. 실험방법은 관전압 60, 70, 81, 90 kVp 별로 검출기 감도 S200, S400, S800, S1000에 해당하는 선질, 입사표면선량, 관전류량, 동적범위를 측정하여 검출기의 성능을 평가하고자 하였다. 그 결과 선질은 모두 합격 기준에 부합하였고, 입사표면선량과 관전류량은 감도가 높게 설정될수록 단계적으로 감소하였다. Dynamic step wedge는 관전압이 높아질수록 관찰 가능한 동적 범위도 함께 증가하였고, 또한 히스토그램은 관전압과 감도가 높게 설정될수록 양자화 이격 현상과 히스토그램 양단의 정보량이 상실되는 언더플로우와 오버플로우가 나타났다. 결론적으로 검출기가 성능 저하로 인하여 자동노출제어장치 사용 시 관전압과 감도 변화에 따른 동적 범위를 제대로 구현해내지 못한다는 것을 알 수 있었고, 검출기 성능평가 시 dynamic step wedge와 히스토그램을 통한 평가가 유용하다는 점을 알 수 있었다.

주사전자현미경용 전자검출기의 설계 및 제작 (Design and Manufacture of an Electron Detector for Scanning Electron Microscope)

  • 전종업;김지원
    • 한국정밀공학회지
    • /
    • 제25권4호
    • /
    • pp.53-60
    • /
    • 2008
  • Electron detectors used in scanning electron microscope accept electrons emitted from the specimen and convert them to an electrical signal that, after amplification, is used to modulate the gray-level intensities on a cathode ray tube, producing an image of the specimen. Electron detector is one of the key components dominating the performance of scanning electron microscope so that the development of electron detectors having high performance is indispensable to acquire high quality images using scanning electron microscope. In this paper, we designed and manufactured an electron detector and conducted a couple of image capture experiments using it. In particular, scintillator which generates light photons when it is struck by high-energy electrons was manufactured and experimental studies on the optimization of manufacturing condition was carried out. From experiments to evaluate the performance of our detector, it was verified that the performance of our detector is equivalent to or better than that of the conventional one.

UV-IR 복합형 화재감지장치 개발 (The Development of UV-IR Combination Flame Detector)

  • 이복영;권오승;정창기;박상태
    • 한국안전학회지
    • /
    • 제16권1호
    • /
    • pp.1-8
    • /
    • 2001
  • All objects emit thermal radiation and this radiation is the basis of the techniques used to detect flames. The usual phenomena occurring in the initial stage of the fire are generally invisible products of a combustion and visible smoke. Liquid or gaseous materials do not undergo a smoldering stage so that fires develop very rapidly. Also, the heat generated by the initial flames is usually not sufficient to activate a heat detector. In this case the most effective criterion for automatic fire detection is the flame. According to the fire regulation of korea, the compulsory standard provided that a flame detector shall be installed in a place that the attachment height of detector is higher than 20 m, chemical plants, hangar, refinery, etc.. The results of the research and development are discriminated between a flame and other radiant emitters, developed a UV detector tube contains an inert gas which absorbs UV radiation, developed PZT pyroelectric element is based on the use of photovoltanic cell, developed IR band-pass filter that only allow a 4.3 $\mu\textrm{m}$ radiation wavelength to reach the sensors and developed UV-IR combination flame detector combined into a single detection device.

  • PDF

강내형 X선 튜브 온도 및 선량 분포 특성 (The Characteristic of Temperature and Dose Distribution of intra oral X-ray Tube)

  • 조성호;이레나
    • 전자공학회논문지
    • /
    • 제50권5호
    • /
    • pp.262-266
    • /
    • 2013
  • 신개념 치과용 X선 촬영장치인 강내형 X선 튜브에 대한 연구가 소개되었다. 이는 초소형의 X-선 튜브를 구강내 삽입하여 외부에서 검출기로 영상을 획득하는 새로운 시스템이다. 본 연구에서는 구내 치근단 촬영을 위해 사용하는 강내형 X선 튜브의 온도분포 및 선량 분포 특성을 조사하였다. X선 튜브의 온도특성을 파악하기 위하여 튜브 표면에 써머커플을 부착하여 튜브 표면에서부터 거리에 대한 온도를 측정하였으며, EBT 필름을 이용하여 튜브표면에서부터 거리에 따른 선량 분포를 측정하였다. 그 결과 냉각장치가 없는 튜브에서 2mm 이상 거리에서 온도는 $27^{\circ}C$로 일정하였으며, 튜브에서 3cm, 5cm일 때 선량분포가 3.14, 1.84mGy로 나타났다. 그 결과 제안한 시스템은 기존 시스템에 비해 낮은 선량에서 안전하게 촬영이 가능한 것으로 향후 구내 치근단 촬영장치에 새로운 변화를 가져올 수 있을 것으로 사료된다.

검지관을 이용한 축산 악취 간이 측정방법 연구 (Simple Measurement of Livestock Foul Smells by Gas Detector Tube)

  • 정재칠;안민호;정종원;최희선;김태진
    • KSBB Journal
    • /
    • 제24권5호
    • /
    • pp.420-424
    • /
    • 2009
  • 악취방지법의 시행으로 악취의 규제가 강화됨에 따라 축산 시설에서 발생하는 악취의 주요 원인 물질인 암모니아와 황화수소를 신속하고 간단한 방법으로 검지할 수 있는 방법으로 화학적 방법을 이용한 가스 검지관을 개발하였다. 악취물질의 농도를 변색길리를 통하여 알 수 있도록 발색반응 메카니즘을 규명하고 이를 정량화 하여 유리관에 충전하여 암모니아와 황화수소 검지관을 제작하였다. 암모니아 검지관은 선형성 및 재현성 평가에서 99.6%의 선형성을 나타내었으며, 검지환경에 따라서 민감한 경향을 나타내었으나, 암모니아 가스에 대한 동일한 경향성을 나타내었다. 또한 황화수소 검지관은 99.7%의 선형성을 나타내었으며, 동일한 시료를 이용한 반복 평가에서 95% 이상의 재현성을 나타내었다.

다이오드 검출기를 이용한 초소형 X선관(Miniature X-ray Tube)의 반가층 측정 (HVL Measurement of the Miniature X-Ray Tube Using Diode Detector)

  • 김주혜;안소현;오윤진;지윤서;허장용;강창무;서현숙;이레나
    • 한국의학물리학회지:의학물리
    • /
    • 제23권4호
    • /
    • pp.279-284
    • /
    • 2012
  • X선은 방사선 진단과 치료 분야에 있어서 다양하고 광범위하게 이용되고 있으며, 최근에는 방사선 치료용 초소형 X선관이 개발되었다. 초소형 X선관은 조사 목적 부위에 직접 삽입하여 사용되므로 제작 시준기에 따라 다양한 각도로 X선 조사가 가능하고, 검사 목적 외의 환자 피폭선량을 최소화한다. 이러한 초소형 X선관의 장점을 이용해서 X선 영상을 획득하는데 적용한다면 X선 진단 분야의 새로운 장을 열 것으로 기대된다. 하지만 초소형 X선관은 본래 치료용으로 설계되었기 때문에 진단용 장비에 적합한 시준기, 필터(added filter) 등이 필요하다. 따라서 자체 제작한 시준기와 필터를 적용하여 초소형 X선관의 빔 특성이 진단용에 적합한지 평가 하였고, 이를 위해서 다이오드 검출기를 이용하여 반가층을 측정하고 측정의 가능성을 평가하였다. 본 연구에서는 Si PIN Photodiode type인 Piranha 검출기(Piranha, RTI, Sweden)를 사용하여 필터 적용 유무에 따른 초소형 X선관의 반가층을 측정하고, 알루미늄 필터를 사용한 측정을 통하여 Piranha 검출기의 반가층 측정의 정확성을 평가하였다. 측정 결과에 따르면 초소형 X선관의 반가층은 필터의 장착에 따라 약 1.9배 증가하여 진단용 방사선 발생 장치의 적합성을 확인하였다. Piranha 검출기의 반가층 자동 측정값은 필터를 미장착한 경우에 실제 반가층 측정값에 비해 50% 높게 측정되어 적용이 불가능하나, 필터를 장착한 경우에는 실제 반가층 측정값과 약 15%의 차이로 감소되었다. 따라서 진단용 필터를 적용했을 경우는 Piranha 검출기의 반가층 자동측정이 가능하여 kV-X선 특성평가를 수월하게 수행할 것으로 기대된다.

공기중 유기용제 혼합물 측정방법의 비교연구 (Comparison of Sampling Methods for Determining Airborne Mixture of Organic Solvents)

  • 천미혜;백남원
    • 한국산업보건학회지
    • /
    • 제1권1호
    • /
    • pp.16-28
    • /
    • 1991
  • A study on comparison of standard charcoal tube method, infrared gas analyzer, and detector tube method were conducted. Measurements were performed simultaneously at same sampling points in an air chamber containing benzene, toluene and xylene vapors. Charcoal tube samles were collected at sampling flowrates of 0.05, 0.2, 0.5, and 1.0 1pm. Results are as follows : 1. Coefficients of variation of results with charcoal tube method for bezene, toluene and xylene mixture vapor were 14.34 % in benzene(0.28-11.12 ppm), 9.20 % in toluene (2.68-135.09 ppm) and 10.21 % in xylene (2.56-82.64 ppm), respectively. 2. Results of infrared gas analyzer in mixture air were non-specific on benzene and toluene. Ratio of results of infrared gas analyzer to those of charcoal tube on benzene, toluene and xylene were 696.4 %, 30.3 % and 36.6 %, respectively. 3. Ratio of responses of detector tubes to those of charcoal tube were 49.4 % in benzene, 22.1 % in toluene and 223.9 % in xylene. Xylene detector tube were interfered by toluene greately. 4. Collection efficiencies of charcoal tubes at low concentraton(benzene : 1 ppm, toluene : 10 ppm, xylene : 10 ppm) were stable on various flowrate from 0.05 to 1.0 1pm, but at high concentrations the efficiency decreased at high flowrate above 0.5 1pm. 5. Within the saturation capacity of charcoal, collection effiency decreased at 0.5-1.0 1pm. Smpling feowrates of 0.05-0.20 1pm were appropriate for sampling organic vapors.

  • PDF