The study of the stereo X-ray system for automated X-ray inspection system using 3D-reconstruction shape information (3차원 형상복원 정보 기반의 검색 자동화를 위한 스테레오 X-선 검색장치에 관한 연구)

  • Hwang, Young-Gwan;Lee, Nam-Ho
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.18 no.8
    • /
    • pp.2043-2050
    • /
    • 2014
  • As most the scanning systems developed until now provide radiation scan plane images of the inspected objects, there has been a limitation in judging exactly the shape of the objects inside a logistics container exactly with only 2-D radiation image information. As a radiation image is just the density information of the scanned object, the direct application of general stereo image processing techniques is inefficient. So we propose that a new volume-based 3-D reconstruction algorithm. Experimental results show the proposed new volume based reconstruction technique can provide more efficient visualization for X-ray inspection. For validation of the proposed shape reconstruction algorithm using volume, 15 samples were scanned and reconstructed to restore the shape using an X-ray stereo inspection system. Reconstruction results of the objects show a high degree of accuracy compared to the width (2.56%), height (6.15%) and depth (7.12%) of the measured value for a real object respectively. In addition, using a K-Mean clustering algorithm a detection efficiency of 97% is achieved. The results of the reconstructed shape information using the volume based shape reconstruction algorithm provide the depth information of the inspected object with stereo X-ray inspection. Depth information used as an identifier for an automated search is possible and additional studies will proceed to retrieve an X-ray inspection system that can greatly improve the efficiency of an inspection.

Comparison of Two Commercial Antibody Enzyme-Linked Immunosorbent Assays for Detection of Porcine Reproductive Respiratory Syndrome Virus Infection (돼지생식기호흡기증후군(PRRS) 바이러스 감염 항체 검출 ELISA 상용 키트의 정확도 비교)

  • Pak, Son-Il;Lee, Seung-Hwan;Park, Kyung-Ae
    • Journal of Veterinary Clinics
    • /
    • v.33 no.2
    • /
    • pp.102-106
    • /
    • 2016
  • More than 20 years after the first report of porcine reproductive and respiratory syndrome virus (PRRSV) in Korea, the disease is still having major impact on domestic pig health and relevant industries. Although ELISA tests are commonly used by veterinarians to guide herd management, data on diagnostic performance of the test in field settings are very limited. The objective of this study was to evaluate two commercially available PRRSV ELISA (IDEXX PRRS X3 ELISA and Bionote PRRSV ELISA 4.0) to detect antibodies against PRRSV on serum samples. To this end, a total of 1,108 sera were recruited from 35 swine farms located in Gyeonggi province and tested at the Gyeonggi Province Veterinary Service Center. All tests were performed according to the manufacturer's instructions, by laboratory technicians who routinely perform PRRS testing on blood samples. Samples were collected from two sources of swine populations with different PRRS prevalence; 60 samples (5.4%) were originated from breeding farms and the remaining 1,048 samples (94.6%) were from farrow-to-finish farms. We applied Bayesian latent class model (LCM) for two-tests in the two-population when the accuracy of the gold standard is not available. The model estimated that Bionote ELISA was a bit more specific but slightly less sensitive. The estimated sensitivity and specificity of the IDEXX ELISA were 99.8% (95% CI 98.1-100%) and 86.4% (95% CI 81.4-96.5%), respectively. Sensitivity, specificity, positive predictive value and negative predictive value for Bionote kit were 98.7% (95% CI 92.8-100%), 89.8% (95% CI 86.2-93.1%), 93.8% (95% CI 91.5-96.0%), and 97.8% (95% CI 87.1-100%), respectively. Based on the Bayesian 95% credible intervals, the sensitivity and specificity of the two ELISAs were not significantly different each other when assuming that two kits were imperfect, indicating that two kits performed equally well in terms of sensitivity and specificity in our filed setting.

Determination of Free 4-hydroxyproline with Dansylchloride by HPLC in Human Urine (소변 중 4-hydroxyproline 분석에 관한 연구)

  • Lee, Keou-Weon;Cho, Young-Bong;Lee, Kyung-Jong
    • Journal of Preventive Medicine and Public Health
    • /
    • v.35 no.4
    • /
    • pp.282-286
    • /
    • 2002
  • Objectives : The level of 4-hydroxyproline (4-Hyp) in human urine was measured using high performance liquid chromatography (HPLC) with a fluorescence detector. This method is useful for medical examinations and investigating the radicals induced by physical, chemical, mental stresses. This method is superior to many published several methods in terms of its low cost and ability to analyze many samples. Methods : The urine from workers in a tire manufacturing company (22 male pre- and post-shift workers) and 18 office-workers as controls were analyzed. Data concerning age, the cumulative drinking amount and the cumulative smoking amount was collected with a questionnaire. The optimum applied amount of dansyl-Cl, the optimum reaction temperature and time, the recoveries and the optimum pH of the eluent and buffer were determined.4-Hyp from human urine was derivatized with dansyl-Cl (dimethylamino-naphthalene-1-sulfonyl chloride) after removing the a-amino acid by a treatment with phthalic dicarboxaldehyde (OPA) and cleaned with Bond Elut C18 column. The 4-Hyp derivatives were separated on a reversed phase column by gradient elution with a phosphate buffer (5 mmol, pH 8.0) and acetonitrile, and detected by fluorescence measurements at 340 nm (excitation) and 538 nm (emission). Results : The detection limit for the urinary free 4-Hyp was $0.364{\mu}mol/l$. The recovery rate of 4-Hyp was 99.7%, and the effective pH of the phosphate buffer and borate buffer were 3.0 and 8.0, respectively. From statistical analysis, age, drinking and smoking did not affect the urinary free 4-Hyp in both the controls and workers. The range of urinary 4-Hyp in the controls, pre-shift, and post-shift workers were 0.33-16.44, N.D-49.06, and $0.32-56.27{\mu}mol/l$. From the pared-sample t-test, the urinary 4-Hyp levels in post-shift workers ($11.82{\pm}6.73\;nmmol/mg\;Cre$) were 2-fold higher than in pre-shift workers ($5.36{\pm}5.53\;nmol;/mg\;Cre$) and controls ($4.91{\pm}4.89\;nmol;/mg\;Cre$). Conclusions : This method was developed with high sensitivity, accuracy, and precision. The present method was effectively applied to analyze the urinary free 4-Hyp in both controls and workers.

Basic Evaluation of Analytical Performance and Clinical Utility of Immunoradiometric TSH Assay (면역방사 계수측정법 (Immunoradiometric, Assay)에 의한 혈청 TSH 측정의 기본적 검토 및 임상적 의의)

  • Suh, Kyo-Il;Cho, Bo-Youn;Lee, Hong-Kyu;Koh, Chang-Soon;Min, Hun-Ki;Lee, Mun-Ho
    • The Korean Journal of Nuclear Medicine
    • /
    • v.21 no.2
    • /
    • pp.143-150
    • /
    • 1987
  • To assess the analytic performance of immunoradiometric TSH assay (IRMA TSH), assay precision determined by intra and interassay variance, assay accuracy determined by dilution and recovery study, were evaluated by using two commercial kit $(Abott^{(R)}\;and\;Daichi^{(R)})$. Normal range of basal serum TSH and TRH stimulated TSH increment were also determined in 234 healthy subjects (male 110, female 124; age 20-70) and 30 voluteers (male 10, female 20; age 21-26). In addition, basal TSH levels of 70 patients with untreated hyperthyroidism, 50 untreated hypothyroidism, and 60 euthyroidism were measured to assess the clinical utility of IRMA TSH. The detection limit of IRMA TSH was 0.04 mU/l and 0.08 mU/l by Abott Kit and Daichi kit respectively. Using Abott kit, intra assay variance were 2.0, 3.1 and 1.4% in mean TSH concentration 2.4, 31.6 and 98.2 mU/l repectively and interassay variance were 2.0 and 3.2% in mean TSH concentration 2.3 and 31.3 mU/l. Mean recovery rate was 92.5% and dilution study showed nearly straight line. When Daichi kit was used, intrasssay variance were 5.6, 5.2 and 6.2% in mean TSH concentration of 2.4, 31.6 and 98.2 mU/l respectively and interassay variance were 7.1 and 7.4% in mean TSH of 2.3 and 31.3 mU/l. Mean recoveray rate was 89.9%. Normal range of basal TSH and TRH stimulated peak TSH were 0.38-4.02 mU/l and 2.85-30.8 mU/l repectively (95% confidence interval, Abott kit used). Sensitivity and specificity of basal TSH levels for diagnosing hypothyroidism as well as specificity for diagnosing hyperthyroidism were 100% by using both kit. Sensitivity of basal TSH level for diagnosing hyperthyroidism was 100% when TSH levels were measured by Abott kit while that was 80.9% when measured by Daichi kit. These results suggest that IRMA TSH was very precise and accurate method and might be used as a first line test in the evaluation of thyroid function.

  • PDF

RCCA End-Tip Examination by ECT (원자로 제어봉 End-Tip 원주방향균열 와전류검사)

  • Lee, H.J.;Nam, M.W.;Jung, G.J.
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.18 no.6
    • /
    • pp.455-463
    • /
    • 1998
  • RCCA(rod cluster control assembly) End-Tip suffers from neutron irradiation and constant vibration due to high-speed internal flow of primary coolant during plant operation. Such operating conditions cause the RCCA end-tip crackings around tile circumferential weldment of the end-tip, and in some cases, the defective end-tips were completly broken loose. However, no reliable inspection techniques for end-tip crackings were developed in the past, although some techniques exist for inspecting RCCA control rod wears. Therefore, NDE group at KEPRI has developed an ECT technique for the detection and the sizing of the end-tip crackings. The technique uses a specially designed surface-riding probe that can detect size of circumferential crackings with an accuracy of ${\pm}5.31%$ RMS error. This paper describes the ECT instrumentation including the ECT probes, calibration bars, as well as technical approaches.

  • PDF

Verification of Viscosity Measurement for Identifying Irradiated Brown Rice (현미의 방사선 처리여부 판별을 위한 점도측정법의 검증)

  • Lee, Jeong-Eun;Jo, Deok-Jo;Choi, Mal-Gum;Kim, Hyun-Ku;Kim, Jeong-Sook;Kwon, Joong-Ho
    • Korean Journal of Food Science and Technology
    • /
    • v.42 no.2
    • /
    • pp.240-245
    • /
    • 2010
  • Brown rice of Korea and China was irradiated at doses ranging from 0 to 15 kGy to verify the identification properties of viscosity measurement by determining the relationship between starch content and specific parameters. The starch contents of brown rice were 71.52 and 64.58% for rice of Korea and China, respectively. Additionally, a higher starch content was associated with a higher viscosity. The viscosity and the corresponding specific parameters decreased significantly as the irradiation dose increased, and these changes were influenced by the spindle speed (50, 150, 300 rpm), with a higher effect being observed at lower speeds. The determination coefficients ($R^2$) describing the relationship between irradiation dose and viscosity values ranged from 0.9423 to 0.9567 in Korean samples and from 0.9119 to 0.9387 in Chinese samples. The viscosity and the corresponding specific parameters enabled identification of the non-irradiated and irradiated brown rice from 30 unknown samples with an accuracy of 90%. Based on these findings, the viscosity and specific parameters can be applied as an additional tool for screening of irradiated brown rice.

Monitoring of illegal compounds and prohibited natural ingredients in foods (식품 중 발기부전치료제 및 사용금지 성분 모니터링)

  • Yun, Jisuk;Choi, Jangduck;Kwon, Kisung;Jo, Cheon-Ho
    • Korean Journal of Food Science and Technology
    • /
    • v.48 no.5
    • /
    • pp.405-412
    • /
    • 2016
  • Illegally adulterated compounds, such as impotency drugs and their synthetic analogues, which have been purported to enhance sexual potency or mood, have been constantly detected in foods including dietary supplements. The adulterated foods with these illegal compounds may threaten public health because their safety and efficacy have not been verified. This study was aimed at investigating illegal compounds in foods and counterfeit products. 54 illegal compounds were assayed using a simultaneous analytical method involving liquid chromatography equipped with photo diode array (LC-PDA) and LC coupled with tandem mass spectrometry (LC-MS/MS). The method was validated in terms of selectivity, linearity, limit of detection (LOD), limit of quantification (LOQ), precision and accuracy. In 48 of 161 samples, we identified 7 different illegal compounds, including sildenafil, tadalafil, chlropretadalafil, demethylsildenafil, dimethyl-thiosildenafil, icariin and yohimbine. When purchasing products marketed for erectile dysfunction or aphrodisiacs, ulmost care should be taken owing to the possible presence of these illegal compounds.

Determination of Phenol in Food using GC/MS (GC/MS를 이용한 식품 중 페놀 분석)

  • Kang, YoungWoon;Ahn, JiEun;Suh, JungHyuck;Park, Sunhee;Yoon, HaeJung
    • Journal of Food Hygiene and Safety
    • /
    • v.29 no.4
    • /
    • pp.312-315
    • /
    • 2014
  • The present study demonstrated the development and validation of the method for the quantification of phenol in food using gas chromatography coupled with mass spectrometry (GC-MS). After spiking of internal standard (Phenol-$d_5$) to food, those samples were extracted with organic solvent mixture (acetone : dichloromethane = 1 : 1, v/v) using ultra sonic extractor and cleaned by gel permeation chromatography (GPC) technique. The amount of phenol was determined by GC/MS. To validate the developed method, we evaluated parameters were the selectivity, linearity, accuracy, precision, and recovery. To demonstrate the selectivity of the method, blank samples of rice, corn, and fish(mackerel) were prepared and subjected to GC-MS analysis. To verify the linearity of the method, six different standard concentrations of phenol at 0.01, 0.05, 0.1, 0.5, 1 and 2.5 mg/kg were evaluated. The correlation coefficient ($r^2$) of calibration curve was 0.9999. The recovery rate for phenol standard calculated by internal standard method were 82.2~101.5% for samples fortified with 0.25, 0.50, and 1.0 mg/kg, respectively. Also the repeatability and reproducibility for validation of precision were 0.2~5.5%. According to the result of the validation, this established method was suitable for AOAC guideline. The limit of detection (LOD) for phenol analysis were 0.03~0.1 mg/kg, and the limit of quantification (LOQ) were 0.1~0.3 mg/kg. Therefore, we established the optimal analysis method for determination of phenol in food using GPC and GC/MS.

Detection of the Factors Related to spermatization in Sclerotinia trifoliorum -I. Course of Fertilization (Sclerotinia trifoliorum의 Spermatization에 관여하는 요인(要因)의 검색(檢索) -I. 균(菌)의 수정과정(受精過程))

  • Uhm, Jae Youl;Kim, Young Tae
    • Current Research on Agriculture and Life Sciences
    • /
    • v.5
    • /
    • pp.127-133
    • /
    • 1987
  • The process of fertilization and changes in anatomical structure of sclerotia during the apothecial formation in Sclerotinia trifoliorum, the causal fungus of sclerotial rot of forage legumes, were investigated. The time of fertilization could be estimated with fair accuracy by the sequencial spermatization of the sclerotia which kept at 15C in saturated moisture. In the case of one strain used in this experiment, fertilization between the sclerotia and spermatia were estimated to take place at around 18days after the sclerotia were placed under the conditions for apothecial induction (15C, saturated moisture). The fertilizable state was maintained for about 45 days and the spermatization thereafter did not induce the apothecial formation. When the sclerotia reached fertilizable state, a number of interwoven hyphal nests were developed within the medulla of sclerotia, regardless of the sexuality of the cultures. Comparing the process of multiplication and growth of the hyphal nests in homothallic and heterothallic culture, they were identified as ascogonium. These ascogonia were persisted for about 45 days. This observation was well coincided with the duration of fertilizable state elucidated by the sequencial spermatization experiment.

  • PDF

Characteristics of the SAR Images and Interferometric Phase over Oyster Sea Farming Site (굴 양식장에서의 SAR 영상 및 간섭위상 특성)

  • 김상완;이창욱;원중선
    • Korean Journal of Remote Sensing
    • /
    • v.18 no.4
    • /
    • pp.209-220
    • /
    • 2002
  • We carried out studies on SAR image intensity and interferometric phase over oyster sea farms. Strong backscattering was observed in amplitude images, and that was considered as a radar signal double bouncing from horizontal bars. These sea farming structures are not visible in satellite optical images except IKONOS image, so that it demonstrates the value of radar remote sensing as an effective tool in support of sea farm detection. The intensity of the image is sensitive to system parameters including wavelength, polarization, and look direction, but does not correlate to tide height. We found that the strongest backscattering can be obtained by L-band HH-polarization with a look direction perpendicular to the horizontal bar. We also succeeded in generating 21 coherent JERS-1 SAR interferometric pairs over the oyster farms. The general trend of the fringe rate of the interferometric phases appeared to be governed by altitude of ambiguity. The general trend was modeled by an inverse function and removed to have a residual phase. The residual phase showed a linear relation with the tide height. The results demonstrate for the first time that SAR can possibly be used to estimate sea level. However, the r.m.s. error of a regression line is 11.7 cm, and that is so far too large to make reliable assessments of sea level in practical applications. Further studies is required to improve the accuracy specifically using multi-polarization SAR data.