• Title/Summary/Keyword: Detection Pressure

Search Result 662, Processing Time 0.026 seconds

Fire Extinguisher Maintenance System using Smart NFC Communication and Real-Time Pressure Measurement (스마트 NFC 통신과 실시간 압력 측정을 이용한 소화기 유지관리 시스템)

  • Park, Byeng-Cheol;Park, Ki-Hong
    • Journal of Digital Contents Society
    • /
    • v.18 no.2
    • /
    • pp.403-410
    • /
    • 2017
  • In this paper, the fire extinguisher maintenance system using smart NFC communication and the real-time pressure measurement is proposed. The proposed system consists of three steps in the flow of information. The first step is to identify the fire extinguisher through NFC tagging in the fire extinguisher module using the smart device. The fire extinguisher appearance check and the real-time pressure measurement is performed in the second step, and the last step sends the check status information to the management server. In particular, the actual pressure value is calculated based on the angle of the green area and the indicating needle. Some experiments are conducted so as to verify the proposed system, and as a result, the proposed system shows that the administrator can effectively control the status information of fire safety check.

Design and Implementation of Mobile ]Respiration Detection Diagnostic System using Ultrasound Sensing Method fficient Multicasting Environment (초음파 센싱 방식을 이용한 이동형 호흡량 측정 진단기의 설계 및 구현)

  • 김동학;김영길
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.8 no.2
    • /
    • pp.509-515
    • /
    • 2004
  • Pulmonary function tests are widely used to diagnose and determine patients' therapy in clinic. And it was also applied in the research of the physiology and dynamics for lung disease. Among the pulmonary function tests, spirometry is the most easy and economic test. Spirometers are medical instruments that measure the instantaneous rate of volume flow of respired Bas. The mechanical spirometer was mostly used in the past. Up to the present, the most popular method of spirometer is the differential pressure technique with which change in the volume of flow are transferred to change in pressure. This kind of instrument suffers from several limitations, pressure drop, difficulty in maintenance and short period of calibration. Therefore, this study has begun to implement ultrasound spirometer, which is free of pressure loss and has wide range, focusing on the flow measurement technique and diagnostic algorithm.

Improment of Diesel Combustion using multiple injection under Cold Start Condition (냉시동 조건에서 디젤 연소 특성 및 연소 개선에 대한 연구)

  • Lee, Haeng-Soo;Lee, Jin-Woo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.4
    • /
    • pp.711-717
    • /
    • 2017
  • Startability and harmful emissions are the main issues in diesel engine development under cold conditions. The characteristics of combustion with multiple injection were investigated under cold start conditions. For quantitative analysis, the in-chamber pressure profile was measured and combustion visualization using direct imaging was accomplished. With multiple injection, the peak in-chamber pressure and heat release rate were increased compared to single injection. In addition, the period of flame luminosity detection was shortened using multiple injection. Combustion by main injection was improved with an increase in heat released by pilot combustion when the pilot injection quantity was increased. Finally, an increase in injection pressure also showed the possibility of combustion improvement. On the other hand, an increase of in the pilot injection quantity and injection pressure can cause an increase in harmful emissions, such as HC and CO due to wall wetting. Therefore, more sensitive calibration will be needed when applying a multiple injection strategy under cold start conditions.

Comparison Analysis of Foot Pressure Characteristics during Walking in Stroke and Normal Elderly (뇌졸중 고령자와 정상인의 보행 시 족압 변화 및 비교 분석)

  • Jung, NamKyo;Park, Se Jin;Kwon, Soon-Hyun;Jun, Jongarm;Yu, Jaehak
    • Journal of Platform Technology
    • /
    • v.9 no.3
    • /
    • pp.36-43
    • /
    • 2021
  • Stroke disease is one of the leading causes of death worldwide, and in particular, it is the most important causative disease that causes disability in the elderly. Since stroke disease often causes death or serious disability, active primary prevention and early detection of prognostic symptoms are very important. In particular, it is necessary to detect and accurately predict stroke prognostic symptoms in daily life and prompt diagnosis and treatment by medical staff. In recent studies, image analysis such as computed tomography (CT) or magnetic resonance imaging (MRI) is mostly used as a methodology for predicting prognostic symptoms in stroke patients. However, this approach has limitations in terms of long test time and high cost. In this paper, we experimented with clinical data on how stroke disease affects foot pressure in elderly in walking. Experiments have shown that there is a significant difference in * p < .05 in 12 cells between the stroke elderly and the normal elderly during walking. As a result, it is significant that we found a significant difference in the gait patterns in daily life of the stroke elderly and the normal elderly.

Present and Prospect of Ocean Observation Using Pressure-recording Inverted Echo Sounder (PIES) (압력측정 전도음향측심기(PIES)를 활용한 해양관측의 현재와 전망)

  • CHANHYUNG JEON;KANG-NYEONG LEE;HAJIN SONG;JEONG-YEOB CHAE;JAE-HUN PARK
    • The Sea:JOURNAL OF THE KOREAN SOCIETY OF OCEANOGRAPHY
    • /
    • v.28 no.1
    • /
    • pp.51-61
    • /
    • 2023
  • Sound can travel a long distance in the ocean; hence, acoustic instruments have been widely used for ocean observations in various fields such as bathymetric survey, object detection, underwater communication, and current measurements. Herein we introduce a pressure-recording inverted echo sounder (PIES) which is one of the most powerful instruments, moored at seafloor for ocean observation in physical oceanography. The PIES can measure various kinds of oceanic phenomena (currents, mesoscale eddies, internal waves, and sea surface height variabilities) and support acoustic telemetry and pop-up data shuttle (PDS) system for remote data acquisition. In this paper, we review uses of PIES and describe present and prospective system of PIES including remote data acquisition toward (quasi) real-time data recovery.

Sasang Constitution may act as a Risk Factor for Hypertension and Pre-hypertension (고혈압 및 전기고혈압 위험요인으로서의 사상체질)

  • Jang, Eunsu;Jeong, Kyoung Sik;Lim, Sueun;Kim, Yunyoung
    • Journal of Sasang Constitutional Medicine
    • /
    • v.34 no.1
    • /
    • pp.37-45
    • /
    • 2022
  • Objectives The purpose of this study was to reveal that Sasang constitution(SC) was associated with hypertension and pre-hypertension and could be a risk factor. Methods We introduced this study to educational personnel in D university in Daejeon, and 275 subjects joined this study. The SC classification was conducted with KS 15 questionnaire. The subjected measured the blood pressure with Jawon medical device automatically after 10 minute rest. The hypertension and pre-hypertension was classified by the guide of the Seventh Report of the Joint National Committee on Prevention, Detection, Evaluation, and Treatment of High Blood Pressure. The frequency analysis and T-test was used in general characteristics, and chi-square test was also used between SC and pre-hypertension and hypertension. Logistic regression was used to calculate the odds ratios (ORs) and 95% confidence interval (95% CI) for pre-hypertension and hypertension. Results The number of Taeeumin(TE), Soeumin(SE), and Soyangin(SY) was 142, 71, and 61 respectively. There was significantly different in systolic and diastolic blood pressure among SC types(p<.001). The distribution of the normal group, pre-hypertension and hypertension group by SC types was significantly different (p<.001). The ORs of TE was significantly increased (ORs 4.039, 95% CI=2.019-8.082 in pre-hypertension and ORs 4.235, 95% CI=1.581-11.348 in hypertension) compared with SE(p<.001), and after adjusting gender and smoking habit, it was still significantly different(p<.001). Conclusions It is possible that SC, especially TE could be a risk factor both pre-hypertension and hypertension.

Nondestructive Examination of PHWR Pressure Tube Using Eddy Current Technique (와전류검사 기술을 적용한 가압중수로 원전 압력관 비파괴검사)

  • Lee, Hee-Jong;Choi, Sung-Nam;Cho, Chan-Hee;Yoo, Hyun-Joo;Moon, Gyoon-Young
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.34 no.3
    • /
    • pp.254-259
    • /
    • 2014
  • A pressurized heavy water reactor (PHWR) core has 380 fuel channels contained and supported by a horizontal cylindrical vessel known as the calandria, whereas a pressurized water reactor (PWR) has only a single reactor vessel. The pressure tube, which is a pressure-retaining component, has a 103.4 mm inside diameter ${\times}$ 4.19 mm wall thickness, and is 6.36 m long, made of a zirconium alloy (Zr-2.5 wt% Nb). This provides support for the fuel while transporting the $D_2O$ heat-transfer fluid. The simple tubular geometry invites highly automated inspection, and good approach for all inspection. Similar to all nuclear heat-transfer pressure boundaries, the PHWR pressure tube requires a rigorous, periodic inspection to assess the reactor integrity in accordance with the Korea Nuclear Safety Committee law. Volumetric-based nondestructive evaluation (NDE) techniques utilizing ultrasonic and eddy current testing have been adopted for use in the periodic inspection of the fuel channel. The eddy current testing, as a supplemental NDE method to ultrasonic testing, is used to confirm the flaws primarily detected through ultrasonic testing, however, eddy current testing offers a significant advantage in that its ability to detect surface flaws is superior to that of ultrasonic testing. In this paper, effectiveness of flaw detection and the depth sizing capability by eddy current testing for the inside surface of a pressure tube, will be introduced. As a result of this examination, the ET technique is found to be useful only as a detection technique for defects because it can detect fine defects on the surface with high resolution. However, the ET technique is not recommended for use as a depth sizing method because it has a large degree of error for depth sizing.

A Study of Liquid Chromatographic Detection Method for Thiocarbamates by Using Photochemical Reaction (광화학 반응을 이용한 티오카바메이트류의 액체 크로마토그래피 검출법에 관한 연구)

  • Dai Woon Lee;Young Hun Park;Yong Wook Choi
    • Journal of the Korean Chemical Society
    • /
    • v.37 no.4
    • /
    • pp.453-461
    • /
    • 1993
  • Detection method was developed using a simply designed photochemical reactor made of teflon coil and low pressure mercury lamp. This method of UV photolysis of analytes followed by UV, fluorescence and electrochemical detection was found to be useful for four thiocarbamates. Analytes eluting from the column are irradiated with a high flux of 254 nm UV light, so that they change to either fluorescent active forms or highly electrochemically sensitive products. Appling this technique to the UV detection, thiocarbamates were converted into long wavelength absorbing products upon UV irradiation. In fluorescence detector four thiocarbamates are not detected at nonirradiated condition but fluorescence signals of MPTC, CPTC photolysates are appeared after irradiation with UV light. The electrochemical detection for the determination of thiocarbamates was enhanced up to 5∼20 fold signal after UV irradiation, compared to that of the nonirradiated. The detection limit of thiocarbamates on electrochemical detector was 13.3∼0.02 ng under pH 7.0, ionic strength $0.5{\times}10^{-2}$ M, phosphate buffer solution. Adducts produced by reaction of photolysates and OPA-MERC in the reaction coil were monitored at 425 nm with fluorescence detector, and one of the photolysates was primary amine.

  • PDF

Development of an Engine Oil Quality Monitoring System (엔진오일 유전상수 변화량 측정에 의한 엔진오일 품질 모니터링 시스템 개발)

  • Chun, Sang-Myung
    • Tribology and Lubricants
    • /
    • v.27 no.3
    • /
    • pp.125-133
    • /
    • 2011
  • The purpose of this study is to develop an engine oil quality monitoring system to warn the abnormal condition of engine oil. To do this, first of all, it is needed a personal controller development to measure the capacitance of a pre-developed engine oil deterioration detection sensor integrated with an oil filter. To measure the capacitance of engine oil in the sensor, it is used the way measuring the electric charging time in a capacitor by impressing DC volt. This method has merits on cost and signal stability. The measured capacitance is compensated by comparing with the one measured by an impedance analyzer. Also, using the dielectric constant gained by an impedance analyzer, the calculating equation of the dielectric constant of engine oil related with the currently developed sensor is decided. Then, the deterioration degree of engine oil is estimated according to the change rate of dielectric constant between green oil and used oil. Finally, using this dielectric constant information together with engine oil temperature and pressure, the currently developed engine oil quality monitoring system is to tell the abnormal state of engine oil.

Optimal Hyper Analytic Wavelet Transform for Glaucoma Detection in Fundal Retinal Images

  • Raja, C.;Gangatharan, N.
    • Journal of Electrical Engineering and Technology
    • /
    • v.10 no.4
    • /
    • pp.1899-1909
    • /
    • 2015
  • Glaucoma is one of the most common causes of blindness which is caused by increase of fluid pressure in the eye which damages the optic nerve and eventually causing vision loss. An automated technique to diagnose glaucoma disease can reduce the physicians’ effort in screening of Glaucoma in a person through the fundal retinal images. In this paper, optimal hyper analytic wavelet transform for Glaucoma detection technique from fundal retinal images is proposed. The optimal coefficients for transformation process are found out using the hybrid GSO-Cuckoo search algorithm. This technique consists of pre-processing module, optimal transformation module, feature extraction module and classification module. The implementation is carried out with MATLAB and the evaluation metrics employed are accuracy, sensitivity and specificity. Comparative analysis is carried out by comparing the hybrid GSO with the conventional GSO. The results reported in our paper show that the proposed technique has performed well and has achieved good evaluation metric values. Two 10- fold cross validated test runs are performed, yielding an average fitness of 91.13% and 96.2% accuracy with CGD-BPN (Conjugate Gradient Descent- Back Propagation Network) and Support Vector Machines (SVM) respectively. The techniques also gives high sensitivity and specificity values. The attained high evaluation metric values show the efficiency of detecting Glaucoma by the proposed technique.