• Title/Summary/Keyword: Detection Key

Search Result 1,206, Processing Time 0.039 seconds

Acrylic Polymer Composition Suitable for Ion Delivery and Selective Detection of Proton, and Hydroxyl and Cu(II) Ions (이온 이동에 적합한 아크릴고분자 박막의 조성과 수소이온, 수산화이온, 구리이온의 선택적 검출)

  • Lee, Dahye;Woo, Heejung;Do, Jung Yun
    • Polymer(Korea)
    • /
    • v.38 no.6
    • /
    • pp.801-808
    • /
    • 2014
  • Ion diffusion and chemical binding to acrylic polymer were investigated in a solid film. The composition of acrylic monomers containing amino group and carboxylic acid was adjusted for rapid ion migration in the film. p-Methylred (PMR) and phenolphthalein derivatives were optically sensitive to the concentration of proton and hydroxyl anion, respectively and verified the ion migration through the film layers. A rapid proton migration was observed in the film of a high amino content. On the other hand, $OH^-$ migration occurred rapidly in a high content of carboxylic acid group. The proton migration occurred through the internal layer as well as surface layer of a film and was reversible during 50 repetition examination. Copper(II) ion migration was examined with a Rhodamine-containing polymer film. The light absorption and emission spectra of a Rhodamine-Cu complex showed the key contribution of carboxylic acid group to the Cu(II) migration in a film.

Cloning and Expression of Inositol Monophosphatase Gene from Streptomyces coelicolor A[3]2 (Streptomyces coelicolor A[3]2에서 Mycothiol 생합성에 관여하는 Inositol Monophosphatase 유전자의 클로닝 및 발현)

  • Kim Jin Kwon;Choi Hack Sun;Kim Seong-Jun;Kim Si Wouk
    • KSBB Journal
    • /
    • v.19 no.6 s.89
    • /
    • pp.462-466
    • /
    • 2004
  • Mycothiol (MSH), a low molecular antioxidant thiol compound, was purified and analyzed from Streptomyns coelicolor A[3]2 by the monobromobimane fluorescence detection method modified by this lab. Through HPLC chromatpgram, MSH fraction was obtained following the elution time of standard MSH (donated by Dr. Robert C. Fahey). That MSH showed the highest concentration among the thiol compounds contained in the cell indicated that MSH was the key thiol compound having antioxidant activity. To understand the role of gene of inositol monophosphatase (I-1-Pase) involved in the MSH biosynthesis, it was isolated from S. coelicolor A(3)2 and cloned and overexpressed in the Escherichia coli. The expressed I-1-Pase was purified through Ni-NTA column. The soluble protein consisted of 281 amino acids, and the molecular weight was 32 kDa. I-1-Pase of S. coelicolor A(3)2 had the sequence homology with those of human and E. coli by 24 and $25\%$, respectively, and had two conserved domains (mofif A and motif B) which were typical of I-1-Pase.

Novel Incremental Spectrum Sensing in Cooperative Cognitive Radio Networks (협력 인지 통신 네트워크에서 새로운 증분형 스펙트럼 검출)

  • Ha, Nguyen Vu;Kong, Hyung-Yun
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.35 no.9A
    • /
    • pp.859-867
    • /
    • 2010
  • In this paper, we consider a novel spectrum sensing system in which firstly, the fusion center (FC) senses and makes the own decision then if its sensing result is not useful for achieving the final decision, the local observations from the cognitive users (CUs) will be required. Moreover, in case that FC needs the results from CUs, we will choose only CU having the highest collected energy to send its local decision to FC. Based on this selecting method, the number of sensing bits can be reduced; hence, we can save the power and the bandwidth for reporting stage in the cognitive radio network (CRN). The mathematical analysis of the key metrics of the sensing schemes (probability of detection, false alarm, e.g.) will be investigated and confirmed by the Monte-Carlo simulation results to show the performance enhancement of the proposed schemes.

Design of A Broadband Bowtie Antenna for RF Spectral Measurements of Alfvén-wave in the KSTAR Tokamak (KSTAR 토카막의 Alfvén파 RF 스펙트럼 측정을 위한 광대역 보우타이 안테나 설계)

  • Woo, Dong Sik;Kim, Sung Kyun;Kim, Kang Wook;Choi, Hyun-Chul
    • Journal of Sensor Science and Technology
    • /
    • v.25 no.1
    • /
    • pp.46-50
    • /
    • 2016
  • During KSTAR plasma experiments, torsional $Alfv\acute{e}n$ waves in the frequency of few GHz or below were detected. To understand this plasma waves during the crash of MHD instabilities, an RF spectrometer has been developed for detection of the radiated RF signals in the KSTAR Tokamak. It has the capability of broadband RF spectral measurement (50 ~ 400 MHz). To detect the broadband RF signals which are radiated from the KSTAR systems, a broadband antenna is the key feature of the RF spectrometer. In this paper, a broadband bowtie antenna for detection of $Alfv\acute{e}n$-waves in the KSTAR Tokamak is presented. Planar-type bowtie antenna is designed and fabricated on an FR4 substrate with thickness of 1.6 mm. The antenna consists of bowtie shaped balanced radiators and broadband planar balun. The antenna is designed to have an input impedance of 50 Ohm, and a taper-shaped balun is adopted for field and impedance matching between 50 Ohm transmission line to 110 Ohm feeding network of balanced radiators. The implemented antenna provides around -3 to 3 dBi of gain for the whole frequency band. The VSWR of the bowtie antenna is less than 12:1 over the frequency bandwidth of 50 to 2000 MHz.

Analysis of Geosmin and 2-MIB in Water by Stir Bar Sorptive Extraction (SBSE) and GC/MS (교반막대추출법(SBSE)과 GC/MS를 이용한 수중의 Geosmin과 2-MIB의 분석)

  • Lee, Hwa-Ja;Kang, Lim-Seok
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.31 no.1
    • /
    • pp.64-69
    • /
    • 2009
  • Musty and earth odors caused by geosmin and 2-MIB are the major complaints from the drinking water consumers. Therefore, early detection of geosmin and 2-MIB is the key to prevent off-flavor occurrence. In this study, a rapid method using stir bar sorptive extraction (SBSE) in combination with the GC/MS was investigated to analyze geosmin and 2-MIB in water. The SBSE method, a solventless extraction technique, was optimized and then applied to the analysis of geosmin and 2-MIB in water. The SBSE technique was found to be a simple and fast procedure that allows many samples to be extracted simultaneously using very small volume (10~20 mL). In addition, the SBSE method offered high recovery and good linear regression coefficient for the geosmin and 2-MIB. The good repeatability of this method can be deduced from the low RSD (7.2~7.6%) at 10 ng/L for geosmin and 2-MIB. The limit of detection was determined 1~2 ng/L and the limit of quantitation was 3~6 ng/L. Above all, the SBSE method proved to be a very practical technique for the analysis of geosmin and 2-MIB in water.

Design and Implementation of Local Forest Fire Monitoring and Situational Response Platform Using UAV with Multi-Sensor (무인기 탑재 다중 센서 기반 국지 산불 감시 및 상황 대응 플랫폼 설계 및 구현)

  • Shin, Won-Jae;Lee, Yong-Tae
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.10 no.6
    • /
    • pp.626-632
    • /
    • 2017
  • Since natural disaster occurs increasingly and becomes complicated, it causes deaths, disappearances, and damage to property. As a result, there is a growing interest in the development of ICT-based natural disaster response technology which can minimize economic and social losses. In this letter, we introduce the main functions of the forest fire management platform by using images from an UAV. In addition, we propose a disaster image analysis technology based on the deep learning which is a key element technology for disaster detection. The proposed deep learning based disaster image analysis learns repeatedly generated images from the past, then it is possible to detect the disaster situation of forest-fire similar to a person. The validity of the proposed method is verified through the experimental performance of the proposed disaster image analysis technique.

A Multi-hop Reservation Method for End-to-End Latency Performance Improvement in Asynchronous MAC-based Wireless Sensor Networks (비동기식 MAC프로토콜 기반의 무선 센서 네트워크에서 단대단 시간 지연 성능 향상을 위한 멀티 홉 예약 기법의 제안)

  • Hong, Sung-Hwa;Jung, Suk-Yong
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.11 no.7
    • /
    • pp.2638-2647
    • /
    • 2010
  • X-MAC reduces transmission delay and energy consumption by using a short preamble instead of the existing long preamble. To solve the problem of X-MAC, this paper proposes a new MAC protocol called Express-MAC. The wireless sensor network is mainly used for the purpose of gathering event data or situation information. Especially, the transmission pattern of the sensor network with the purpose of event detection such as intrusion detection is very intermittent as well as successively occurring when a single event takes place in most cases. By reflecting sensor network's key transmission patterns as above, EX-MAC has used multi-hub path's path reservation system and awake section's transmission time reservation method in data transmission when the first event takes place. The awake time reservation in transmission path has improved successive data transmission's end-to-end delay, and it has also increased efficiency in terms of energy consumption by reducing the preamble length of data transmission and reception node.

Usefulness of $^{11}C-Methyl-L-and$ D-Methionine PET in Gliomas : with Special Attention to Recurrence

  • Cho, Won-Sang;Kim, Chi-Heon;Kim, Jeong-Eun;Chung, June-Key;Paek, Sun-Ha;Jung, Hee-Won
    • Journal of Korean Neurosurgical Society
    • /
    • v.39 no.3
    • /
    • pp.176-182
    • /
    • 2006
  • Objective : This study concernes the usefulness of $^{11}C-methyl-L-and$ D-methionine[Met]-positron emission tomography[PET] for glioma grading and detection of recurrence in gliomas, compared with fluorine-18, 2-fluoro-deoxyglucose[FDG]-PET. Methods : Eighty patients underwent Met-PET study for evaluation of glioma : 37 astrocytomas [WHO grade II, 3; III, 8; IV, 26]. 27 oligodendrogliomas [WHO grade II, 16; III, 11]. and 12 suspicious recurrent gliomas. All images were taken within 2 weeks before operation. For suspicious recurrent cases on magnetic resonance images, both FDG-PET and Met-PET were performed. Results : In astrocytoma, Mean maximum standard uptake value[SUV] of region of interest[ROI] was not different between WHO grades [p=0.108]. but ROI/normal contralateral tissue SUV [T/N] ratio was statistically different between WHO grades [p=0.002]. T/N ratio was more closely related to visual scale than maximum SUV of ROI [p<0.001 and p=0.107 respectively]. In oligodendroglioma, there was no statistical difference between WHO grades in view of maximum SUV and T/N ratio. For recurrent gliomas, sensitivity of FDG-PET and Met-PET was 25% and 100%, while specificity of FDG-PET and Met-PET were 100% and 80%, respectively. Conclusion : Met-PET might be an appropriate tool for tumor grading in astrocytoma and be more sensitive for detection of recurrence in gliomas than FDG-PET.

Background Subtraction Algorithm Based on Multiple Interval Pixel Sampling (다중 구간 샘플링에 기반한 배경제거 알고리즘)

  • Lee, Dongeun;Choi, Young Kyu
    • KIPS Transactions on Software and Data Engineering
    • /
    • v.2 no.1
    • /
    • pp.27-34
    • /
    • 2013
  • Background subtraction is one of the key techniques for automatic video content analysis, especially in the tasks of visual detection and tracking of moving object. In this paper, we present a new sample-based technique for background extraction that provides background image as well as background model. To handle both high-frequency and low-frequency events at the same time, multiple interval background models are adopted. The main innovation concerns the use of a confidence factor to select the best model from the multiple interval background models. To our knowledge, it is the first time that a confidence factor is used for merging several background models in the field of background extraction. Experimental results revealed that our approach based on multiple interval sampling works well in complicated situations containing various speed moving objects with environmental changes.

Dual Sensing with Voltage Shifting Scheme for High Sensitivity Touch Screen Detection (고감도 터치스크린 감지를 위한 양방향 센싱과 전압쉬프팅을 이용한 센싱 기법)

  • Seo, Incheol;Kim, HyungWon
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.52 no.4
    • /
    • pp.71-79
    • /
    • 2015
  • This paper proposes a new touch screen sensing method that improves the drawback of conventional single-line sensing methods for mutual capacitance touch screen panels (TSPs). It introduces a dual sensing and voltage shifting method, which reduces the ambient noise effectively and enhances the touch signal strength. The dual sensing scheme reduces the detection time by doubling the integration speed using both edges of excitation pulse signals. The voltage shifting method enhances the signal-to-noise ratio (SNR) by increasing the voltage range of integrations, and maximizing the ADC's input dynamic range. Simulation and experimental results using a commercial 23" large touch screen show an SNR performance of 43dB and a scan rate 2 times faster than conventional schemes - key properties suited for a large touch screen panels. We implemented the proposed method into a TSP controller chip using Magnachip's CMOS 0.18um process.