• 제목/요약/키워드: Design Shear Force

검색결과 580건 처리시간 0.024초

Fine Blanking의 가장자리 Bridge 최소화 방법에 관한 연구 (A Study on Edge Bridge Minimization of Fine Blanking Process)

  • 김기태
    • 한국기계가공학회지
    • /
    • 제12권4호
    • /
    • pp.108-113
    • /
    • 2013
  • Industrialization and modernization of the beginning of the IT industry is growing very fast. Since telecommunications industry was developed rapidly, technologies about miniaturization and high-precision of parts have been actively developed to lead information revolution. generally, the entire shear surface of the product applying fine blanking technology must be very precise. Fine blanking is used to save cost by avoiding post-processing of the product. When using press blanking, it spends a lot of money on the production by using many post-processing. Fine blanking typically used in 0.5~18 mm thick steel plate. Because a lot of post-processing cost can be used to process, except for fine blanking. In order to develop components "CHANCE CONTENTS" in the fine blanking process, the purpose of this study is to minimize the edge of the bridge, secured 95% of the material thickness of the shear surface using the 1.6 mm thickness of the material SPCC. Blanking process by introducing after changing thickness through forging process, due to change in vee-rring force and counter force, the experimental amount of depressions and flatness and the shear surface were analyzed.

보강 철근 정착 홀을 갖는 합성 전단연결재를 적용한 콘크리트 충전 PHC말뚝의 전단성능 평가 (Shear Experiments on Concrete Filled PHC Pile with Composite Shear Connectors with Rebar Holes)

  • 김정회;박영식;민창식
    • 콘크리트학회논문집
    • /
    • 제29권3호
    • /
    • pp.259-266
    • /
    • 2017
  • 본 연구는 PHC말뚝의 단점인 전단력을 보강한 기능성말뚝을 개발하여 보다 경제적이고 합리적인 말뚝의 현장 적용에 기여하고자 하였다. 본 연구를 통해 개발된 CFP말뚝은 링형 합성 전단연결재를 배치하고 PHC말뚝 중공부에 콘크리트를 속채움함으로써 말뚝의 전단성능을 증대시키고, PHC말뚝 내 보강철근(H13-8ea)과 말뚝 중공부의 보강철근(H19-8ea)을 배치하여 횡보강철근비 증대에 따른 전단강도를 향상시켰다. 또한, 속채움 콘크리트와 PHC말뚝의 합성거동을 위해 말뚝 보강철근의 정착 홀이 형성된 합성 전단연결재를 배치하여 보강철근의 다월력을 말뚝의 전단강도 증진에 효과적으로 반영시켰다. CFP말뚝의 전단설계와 성능을 검증하고자 도로교설계기준의 한계상태설계법(2012)을 적용한 전단강도를 산출하였고, 말뚝 시험규정인 KS F 4306에서 제시한 실험방법을 통해 결과값을 비교 검토하였다. CFP말뚝의 단면별 설계전단강도와 실험결과 각 시험체는 설계전단강도 대비 평균 2.20, 2.15, 2.05의 안전율을 확보하는 것으로 나타나 효과적인 전단강도 예측이 가능할 것으로 생각된다.

Elastic stiffness of stud connection in composite structures

  • Qin, Xi;Yang, Guotao
    • Steel and Composite Structures
    • /
    • 제39권4호
    • /
    • pp.419-433
    • /
    • 2021
  • In composite structures, shear connectors are crucial components to resist the relative slip between the steel and concrete, and thereby to achieve the composite actions. In the service stage, composite structures are usually in elastic state, so the elastic stiffness of the shear connection is a quite important parameter in the structural analysis of composite structures. Nevertheless, the existing studies mainly focus on the load-slip relationship rather than the tangent stiffness at the initial elastic stage. Furthermore, when composite beams subjected to torque or local load, shear connections are affected by both tensile force and shear force. However, the stiffness of shear connections under combined effects appears not to have been discussed hitherto. This paper investigates the initial elastic stiffness of stud connections under combined effects of biaxial forces. The initial expression and the relevant parameters are obtained by establishing a simplified analytical model of the stud connection. Afterwards, parametric finite element analysis is performed to investigate the effects of the relevant factors, including the stud length, stud diameter, elastic modulus of concrete, elastic modulus of steel and volume ratio of reinforcement. The feasibility of the proposed modelling has been proved by comparing with sufficient experimental tests. Based on the analytical analysis and the extensive numerical simulations, design equations for predicting the initial elastic stiffness of stud connections are proposed. The comparison between the equations and the data of finite element models demonstrates that the equations are accurate enough to serve for engineering communities.

면진구조물의 기초전단력에 대한 실험적 평가 (Experimental Evaluation on the Base Shear Force of a Bas Isolation System)

  • 김영중
    • 한국지진공학회:학술대회논문집
    • /
    • 한국지진공학회 1999년도 춘계 학술발표회 논문집 Proceedings of EESK Conference-Spring
    • /
    • pp.169-177
    • /
    • 1999
  • The base shear force and the overturning moment are important factors for the earthquake design of a structure. These should be predicted exactly especially when the nonlinear seismic isolation bearings are used against earthquake motions. Generally these are derived by the acceleration responses of a structure with the he assumed masses. However these can be contaminated by the noise in the measured responses and the uncertainty of assumed masses. This paper presents the results of the derived base shear force and overturning moment compared with the measured results by multi-axis load cells. Also discussions are made on the cross-coupling effects of the multi-axis load cell.

  • PDF

Force-based seismic design of steel haunch retrofit for RC frames

  • Ahmad, Naveed
    • Earthquakes and Structures
    • /
    • 제20권2호
    • /
    • pp.133-148
    • /
    • 2021
  • The paper presents a simplified force-based seismic design procedure for the preliminary design of steel haunch retrofitting for the seismic upgrade of deficient RC frames. The procedure involved constructing a site-specific seismic design spectrum for the site, which is transformed into seismic base shear coefficient demand, using an applicable response modification factor, that defines base shear force for seismic analysis of the structure. Recent experimental campaign; involving shake table testing of ten (10), and quasi-static cyclic testing of two (02), 1:3 reduced scale RC frame models, carried out for the seismic performance assessment of both deficient and retrofitted structures has provided the basis to calculate retrofit-specific response modification factor Rretrofitted. The haunch retrofitting technique enhanced the structural stiffness, strength, and ductility, hence, increased the structural response modification factor, which is mainly dependent on the applied retrofit scheme. An additional retrofit effectiveness factor (ΩR) is proposed for the deficient structure's response modification factor Rdeficient, representing the retrofit effectiveness (ΩR=Rretrofitted /Rdeficient), to calculate components' moment and shear demands for the retrofitted structure. The experimental campaign revealed that regardless of the deficient structures' characteristics, the ΩR factor remains fairly the unchanged, which is encouraging to generalize the design procedure. Haunch configuration is finalized that avoid brittle hinging of beam-column joints and ensure ductile beam yielding. Example case study for the seismic retrofit designs of RC frames are presented, which were validated through equivalent lateral load analysis using elastic model and response history analysis of finite-element based inelastic model, showing reasonable performance of the proposed design procedure. The proposed design has the advantage to provide a seismic zone-specific design solution, and also, to suggest if any additional measure is required to enhance the strength/deformability of beams and columns.

Role of membrane forces in seismic design of reinforced concrete liquid storage structures

  • Schnobrich, W.C.
    • Structural Engineering and Mechanics
    • /
    • 제10권6호
    • /
    • pp.533-543
    • /
    • 2000
  • To prevent major cracking and failure during earthquakes, it is important to design reinforced concrete liquid storage structures, such as water and fuel storage tanks, properly for the hydrodynamic pressure loads caused by seismic excitations. There is a discussion in recent Codes that most of the base shear applied to liquid containment structures is resisted by inplane membrane shear rather than by transverse flexural shear. The purpose of this paper is to underline the importance of the membrane force system in carrying the base shear produced by hydrodynamic pressures in both rectangular and cylindrical tank structures. Only rigid tanks constrained at the base are considered. Analysis is performed for both tall and broad tanks to compare their behavior under seismic excitation. Efforts are made to quantify the percentage of base shear carried by membrane action and the consequent procedures that must be followed for safe design of liquid containing storage structures.

지진시 고층 건물 밑면전단력 산정을 위한 지반계수 결정에 대한 연구 (Evaluation of Soil Factors for Determination of Seismic Base Shear Force for High Story Buildings During Earthquake)

  • 윤종구;김동수;임종석;손덕길
    • 한국지반공학회논문집
    • /
    • 제19권6호
    • /
    • pp.85-97
    • /
    • 2003
  • 본 논문에서는 건축물 하중기준 및 해설에서 제시된 지반분류 방법으로 지반 III 또는 IV에 해당하는 지반을 대상으로 등가선형해석을 수행하였고, 해석에서 얻어진 스펙트럴 가속도 값으로 지반계수를 역산하여 국내 각 기준에서 제시하고 있는 지반계수와 비교 검토하였다. 해석결과 고유주기 0.9초 이상 고층 건물의 경우 지반 III의 경우 지반 II의 지반계수의 사용이 가능하였고, IV의 경우 지반 III의 지반계수를 사용하여도 충분하였다. 또한, 대부분의 해석에서 얻어진 지반계수의 값이 국내 내진설계기준의 값보다 상당히 작게 나타났다. 이는 내진설계시 국내 내진설계기준을 그대로 적용하면 구조물 밑면전단력이 보수적으로 산정될 수 있음을 의미한다.

철판삽입 합성전단벽의 전단강도와 내진거동 (Shear Strength and Seismic Behavior of the Composite Shear Wall with the Steel Plate Embedded in the RC Wall)

  • 천영수;박지영;이종윤
    • 토지주택연구
    • /
    • 제8권3호
    • /
    • pp.211-221
    • /
    • 2017
  • This study proposed hybrid coupled shear wall in the steel plate insertion method, which is capable of reinforcing the shear strength of the entire wall without increasing wall thickness in the wall-slab apartment buildings. The proposed hybrid coupled shear wall was tested for its effectiveness, shear strength and seismic behavior in experiment. As a test result, the shear strength improvement by the proposed hybrid coupled shear was found effective. Integral-type of steel plate insertion was found more effective than separate-type steel plate insertion. In this case, if the stud enforcement method proposed in this study was used, the shear strength of hybrid coupled shear wall was recommended to calculate using the KBC2016 0709.4.1(3) method. The steel plate inserted in the proposed method was found to have no significant impact on the final fracture behavior and bending strength of hybrid coupled shear wall. The shear strength at the final destruction of the wall was merely about 1/50 of the entire design shear strength. Thus, it is deemed that the wall was over excessively designed regarding the shear force in the existing design method. This finding indicates further study on wall designing to ensure effective and economic designing based on appropriate strength estimation under the destruction mechanism.

Wind Load Combinations Including Torsion for Rectangular Medium-rise Buildings

  • Stathopoulos, T.;Elsharawy, M.;Galal, K.
    • 국제초고층학회논문집
    • /
    • 제2권3호
    • /
    • pp.245-255
    • /
    • 2013
  • This paper presents the results of a set of wind tunnel tests carried out to examine wind-induced overall structural loads on rectangular medium-rise buildings. Emphasis was directed towards torsion and its correlation with peak shear forces in transverse and longitudinal directions. Two building models with the same horizontal dimensions but different gabled-roof angles ($0^{\circ}C$ and $45^{\circ}C$) were tested at different full-scale equivalent eave heights (20, 30, 40, 50, and 60 m) in open terrain exposure for all wind directions (every $15^{\circ}C$). Wind-induced pressures were integrated over building surfaces and results were obtained for along-wind force, across-wind force, and torsional moment. Maximum wind force component was given along with the other simultaneously-observed wind force components normalized by the overall peak. The study found that for flat-roofed buildings maximum torsion for winds in transverse direction is associated with 80% of the overall shear force perpendicular to the longer horizontal building dimension; and 45% of the maximum shear occurs perpendicular to the smaller horizontal building dimension. Comparison of the wind tunnel results with current torsion provisions in the American wind standard, the Canadian and European wind codes demonstrate significant discrepancies. Suggested load combination factors were introduced aiming at an adequate evaluation of wind load effects on rectangular medium-rise buildings.

대구경 콘크리트 충전형 합성기둥의 전단 설계식 분석 (Investigation of Shear Design Expressions of Large-Diameter Concrete-Filled Steel Tubes(CFT))

  • 정은비;염희진;유정한
    • 한국강구조학회 논문집
    • /
    • 제27권4호
    • /
    • pp.399-410
    • /
    • 2015
  • 콘크리트 충전형 합성기둥(Concrete filled steel tube, CFT)은 철근콘크리트, 강구조보다 뛰어난 변형 능력과 강도 갖고 있다. CFT 현장타설말뚝은 지진하중, 토양액상화 등에 의해 큰 국부전단력을 경험하게 되며 이를 방지하기 위해 큰 직경으로 설계되어 진다. 그러나 현행 기준의 전단 설계식은 CFT의 구속효과를 고려하지 못하고 있으며, 상당히 보수적인 설계식을 제시하고 있다. 전단 설계식의 개선을 위한 선행 전단 실험연구가 거의 없으며 그조차 소구경의 실험연구로만 존재한다. 이 연구는 대구경 콘크리트 충전형 합성기둥의 개선된 전단 설계식을 제안하기 위한 기초연구로써, 원형 CFT 기둥 전단의 선행 실험연구와 현행 설계기준 비교분석을 실행하였다.