Experimental Evaluation on the Base Shear Force of a Bas Isolation System

면진구조물의 기초전단력에 대한 실험적 평가

  • 김영중 (한국기계연구원 구조시스템연구부 진동연구그룹)
  • Published : 1999.04.01

Abstract

The base shear force and the overturning moment are important factors for the earthquake design of a structure. These should be predicted exactly especially when the nonlinear seismic isolation bearings are used against earthquake motions. Generally these are derived by the acceleration responses of a structure with the he assumed masses. However these can be contaminated by the noise in the measured responses and the uncertainty of assumed masses. This paper presents the results of the derived base shear force and overturning moment compared with the measured results by multi-axis load cells. Also discussions are made on the cross-coupling effects of the multi-axis load cell.

Keywords