• Title/Summary/Keyword: Department of Radiological Science

Search Result 2,510, Processing Time 0.049 seconds

Analysis of Radiation Protection, Awareness and Attitude of Radiological Technologist in Mammography Room (유방촬영실에 근무하는 방사선사의 방사선 방어, 인식 및 태도에 관한 분석)

  • Hong, Dong-Hee
    • Journal of radiological science and technology
    • /
    • v.40 no.4
    • /
    • pp.557-565
    • /
    • 2017
  • This study was conducted to investigate the radiation protection, awareness, and attitude of radiological technologists in the mammography room due to the low energy use of breast imaging. Data collection was performed by 222 independent radiological technologists in the breast and breast clinic of six hospitals except Jeju Island. The independent sample t-test and oneway variance analysis were performed. As a result, it was found that the lower the number of men(p<0.05), the age of 30s(p<0.05), the marriage(p<0.05), the work experience of more than 10 years(p<0.05), the working hours of 8 hours(p<0.01), the less the impact of radiation(p<0.01), the more important it was to radiation defense. appear. This is thought to be influenced by the work specificity and work environment of the mammography room, and it will be used as a basic data to raise awareness and act on the exposure through analysis with other factors.

Location Studies of Prostate Volume Measurement by using Transrectal Ultrasonography: Experimental Study by Self-Produced Prostate Phantom (경직장초음파를 이용한 전립선 볼륨측정 시의 위치 연구: 전립선모형 제작과 실험)

  • Kim, Yun-Min;Yoon, Joon;Byeon, II-kyun;Lee, Hoo-Min;Kim, Hyeong- Gyun
    • Journal of radiological science and technology
    • /
    • v.38 no.4
    • /
    • pp.437-442
    • /
    • 2015
  • Accurate volume measurement of the prostate is a significant role in determining the result of diagnosis and treatment of benign prostate hyperplasia. The purpose of this study was to determine, when measuring prostate volume by TRUS, whether location is more accurately determined by transaxial or longitudinal scanning. With reference to the patient's image, it was produced six prostate model. It compares the actual volume and the measurement volume, and find the optimal measurement position of each specific model. Prostate volume measured by TRUS closely correlates with prostate phantom volume. There was no significant difference(p = .156). To measure the accurate volume of prostate with focal protrusion, its length should be measured exclude the protrusions.

Analysis of Image Quality According to BMI of Digital Chest Radiography: Focusing on Bureau of Radiological Health Evaluation (디지털 흉부 방사선 영상의 체질량지수에 따른 영상품질 분석: 미국 방사선 안전국 규정 평가표 중심으로)

  • Jin, Seong-jin;Im, In-Chul;Cho, Ji-Hwan
    • Journal of radiological science and technology
    • /
    • v.40 no.1
    • /
    • pp.1-6
    • /
    • 2017
  • Visual evaluation of chest radiograph images is the most practical and effective method. This study compared the Body Mass Index, waist circumference, and mAs with chest radiographs of 351 women. The Bureau of Radiological Health method was used to evaluate the image quality of chest X-ray images by anatomical and physical methods. The average age of the subjects was $30.17{\pm}4.73$ and the average waist circumference was $66.91{\pm}4.67cm$. The mean Body Mass Index value was $20.21{\pm}2.23$, the mean value of mAs was $3.04{\pm}0.78$, and the mean value of Bureau of Radiological Health was $79.83{\pm}8.45$. When the Body Mass Index value increased, waist circumference and mAs mean value increased. The mean value of Body Mass Index was statistically significant(p<0.05) in Group 4 compared to Groups 1 and 2, with increasing Body Mass Index. Exposure control of the automatic exposure control system is considered to be well performed according to body thickness or Body Mass Index at the time of chest radiography. As the Body Mass Index increases, the thickness of the body increases and the breast thickness of the woman also increases. Therefore, it is considered that the exposure amount is changed by the automatic exposure control device to affect the image quality.

Current Status and Future of PACS in Seoul National University Hospital

  • Cho Myung Soon;Kim Jong Hyo
    • Journal of The Korean Radiological Technologist Association
    • /
    • v.25 no.1
    • /
    • pp.18-18
    • /
    • 1999
  • We have studied DR of medical science at SNUH since early 90's, founded the basis of Picture Archiving Communication System(PACS) used for actual clinic parts, has acquired images gradually since January H and came to acquire images in all examinations ex

  • PDF

The Educational Pending Problems for the Safe Management of Diagnostic Imaging Equipment and the Current Status. (진단용 방사선 발생장치 안전관리를 위만 교육현안과 현주소)

  • Song Tea-ho;Gho Heung;Kim Myung-hoe
    • Journal of The Korean Radiological Technologist Association
    • /
    • v.28 no.1
    • /
    • pp.74-82
    • /
    • 2002
  • 1. Purpose Presently, the service areas of those who we engaged in radiation works are being specialized. Thus, in this study, we propose a way for efficiently improving mutual relationship between the works of the radiation technicians(radiologists) and

  • PDF

Pre- and Immediate Post-Kasai Portoenterostomy Shear Wave Elastography for Predicting Hepatic Fibrosis and Native Liver Outcomes in Patients With Biliary Atresia

  • Haesung Yoon;Kyong Ihn;Jisoo Kim;Hyun Ji Lim;Sowon Park;Seok Joo Han;Kyunghwa Han;Hong Koh;Mi-Jung Lee
    • Korean Journal of Radiology
    • /
    • v.24 no.5
    • /
    • pp.465-475
    • /
    • 2023
  • Objective: To evaluate the feasibility of ultrasound shear wave elastography (SWE) for predicting hepatic fibrosis and native liver outcomes in patients with biliary atresia. Materials and Methods: This prospective study included 33 consecutive patients with biliary atresia (median age, 8 weeks [interquartile range, 6-10 weeks]; male:female ratio, 15:18) from Severance Children's Hospital between May 2019 and February 2022. Preoperative (within 1 week from surgery) and immediate postoperative (on postoperative days [PODs] 3, 5, and 7) ultrasonographic findings were obtained and analyzed, including the SWE of the liver and spleen. Hepatic fibrosis, according to the METAVIR score at the time of Kasai portoenterostomy and native liver outcomes during postsurgical follow-up, were compared and correlated with imaging and laboratory findings. Poor outcomes were defined as intractable cholangitis or liver transplantation. The diagnostic performance of SWE in predicting METAVIR F3-F4 and poor hepatic outcomes was analyzed using receiver operating characteristic (ROC) analyses. Results: All patients were analyzed without exclusion. Perioperative advanced hepatic fibrosis (F3-F4) was associated with older age and higher preoperative direct bilirubin and SWE values in the liver and spleen. Preoperative liver SWE showed a ROC area of 0.806 and 63.6% (7/11) sensitivity and 86.4% (19/22) specificity at a cutoff of 17.5 kPa for diagnosing F3-F4. The poor outcome group included five patients with intractable cholangitis and three undergoing liver transplantation who showed high postoperative liver SWE values. Liver SWE on PODs 3-7 showed ROC areas of 0.783-0.891 for predicting poor outcomes, and a cutoff value of 10.3 kPa for SWE on POD 3 had 100% (8/8) sensitivity and 73.9% (17/23) specificity. Conclusion: Preoperative liver SWE can predict advanced hepatic fibrosis, and immediate postoperative liver SWE can predict poor native liver outcomes in patients with biliary atresia.

Diffusion-Weighted Imaging for Differentiation of Biliary Atresia and Grading of Hepatic Fibrosis in Infants with Cholestasis

  • Jisoo Kim;Hyun Joo Shin;Haesung Yoon;Seok Joo Han;Hong Koh;Myung-Joon Kim;Mi-Jung Lee
    • Korean Journal of Radiology
    • /
    • v.22 no.2
    • /
    • pp.253-262
    • /
    • 2021
  • Objective: To determine whether the values of hepatic apparent diffusion coefficient (ADC) can differentiate biliary atresia (BA) from non-BA or be correlated with the grade of hepatic fibrosis in infants with cholestasis. Materials and Methods: This retrospective cohort study included infants who received liver MRI examinations to evaluate cholestasis from July 2009 to October 2017. Liver ADC, ADC ratio of liver/spleen, aspartate aminotransferase to platelet ratio index (APRI), and spleen size were compared between the BA and non-BA groups. The diagnostic performances of all parameters for significant fibrosis (F3-4) were obtained by receiver-operating characteristics (ROCs) curve analysis. Results: Altogether, 227 infants (98 males and 129 females, mean age = 57.2 ± 36.3 days) including 125 BA patients were analyzed. The absolute ADC difference between two reviewers was 0.10 mm2/s for both liver and spleen. Liver ADC value was specific (80.4%) and ADC ratio was sensitive (88.0%) for the diagnosis of BA with comparable performance. There were 33 patients with F0, 15 with F1, 71 with F2, 35 with F3, and 11 with F4. All four parameters of APRI (τ = 0.296), spleen size (τ = 0.312), liver ADC (τ = -0.206), and ADC ratio (τ = -0.288) showed significant correlation with fibrosis grade (all, p < 0.001). The cutoff values for significant fibrosis (F3-4) were 0.783 for APRI (area under the ROC curve [AUC], 0.721), 5.9 cm for spleen size (AUC, 0.719), 1.044 x 10-3 mm2/s for liver ADC (AUC, 0.673), and 1.22 for ADC ratio (AUC, 0.651). Conclusion: Liver ADC values and ADC ratio of liver/spleen showed limited additional diagnostic performance for differentiating BA from non-BA and predicting significant hepatic fibrosis in infants with cholestasis.

A Study on the Physical Characteristics of Photoconductors for Photon Counting based X-ray Sensor Application (광계수형 기반의 X선 영상센서 적용을 위한 광도전체 물성 연구)

  • Park, Ji Koon;Noh, Si Cheol;Choi, Il Hong;Jung, Bong Jae;Kang, Sang Sik
    • Journal of the Korean Society of Radiology
    • /
    • v.8 no.7
    • /
    • pp.423-428
    • /
    • 2014
  • Digital X-ray imaging devices using a TFT based flat panel array has been used in medical field. But, recently, lots of research on the photon counting sensor has been reported. In this study, we evaluated the physical properties of the photoconductor by suggesting the standard and testing method for quantitative performance evaluation of photon counting x-ray imaging sensor. First, we measured the leakage current and the sensitivity of photon counting x-ray imaging sensor and we evaluated the characteristic of rising time for determining the signal shaping time. In addition, the set-up study was conducted on the basis of the IEC 62220-1-2 recommendations to define the number of incident photons per unit area. And the efficiency of the charge collection was also evaluated. As a result, the characteristic was measured as $200pA/mm^2$ of the leakage current, $7{\mu}C/cm^2R $ of the X-ray sensitivity, and $0.765{\mu}s$ of the rising time.