• Title/Summary/Keyword: Department of Radiological Science

Search Result 2,510, Processing Time 0.034 seconds

Development of Self-Questionnaire for Internal Dose Assessment by Food Ingestion

  • JiEun Lee;Hyo Jin Kim;Yong-Uk Kye;Dong-Yeon Lee;Wol Soon Jo;Chang-Geun Lee;Jung-Ki Kim;Yeong-Rok Kang
    • Journal of Radiation Protection and Research
    • /
    • v.47 no.4
    • /
    • pp.204-213
    • /
    • 2022
  • Background: The accident at the Fukushima Daiichi nuclear power plant increased the level of anxiety related to the radioactive contamination of various foods sourced in Japan. Particularly, after the accident, the detection of artificial radionuclides in locally produced foods raised food safety concerns. In this study, the radioactivity concentrations and annual ingestions of 40K and 137Cs in food products commonly and frequently consumed by the general public were investigated, and the annual effective dose of each was evaluated. Materials and Methods: The 2016-2018 data from the Radiation Safety Management Report released by the Korea Nuclear Safety Technology Center was referenced for the evaluation of the amounts of 40K and 137Cs contained in food. Using the food-ingestion survey mentioned above as a reference, we selected 62 foods to include in our radioactivity concentration and dose assessment. We also developed a questionnaire and evaluated the responses from the subjects who answered the questionnaire. Results and Discussion: The radioactivity concentration of 137Cs was found to be close to or below the level of minimum detectable activity. Additionally, the annual ingestion of 62 foods was 294.77 kg/yr, the effective doses from 40K and 137Cs were 136.4 and 0.163 μSv/yr, respectively. Conclusion: Thus, the findings confirmed that the effective dose from 40K and 137Cs in food tends to be lower than the effective dose limit of 1 mSv/yr suggested by the International Commission on Radiological Protection (ICRP) Publication 60. The questionnaire developed in this study is expected to be useful for estimating the annual effective dose status of Korean adults who consume foods containing 40K and 137Cs.

A Study on the Usefulness of Copper Filters Made with 3D Printers in Longbone Examination Using Long Length Detector (장골 검출기를 이용한 장골 검사에서 3D 프린터로 제작한 구리 필터의 유용성 연구)

  • Kim, Woo-Young;Seo, Hyun-Soo;Han, Bong-Ju;Yoon, Myeong-Seong;Lee, Young-Jin
    • Journal of radiological science and technology
    • /
    • v.44 no.6
    • /
    • pp.607-613
    • /
    • 2021
  • Long-bone examination is mainly used for inspection of the lower extremities. Recently, a long length detector (FXRD-1751S, VIEWORKS, Korea) with three digital detectors attached has been developed. High energy X-rays are used because pelvic areas require high image quality. In this case, X-rays are transmitted a lot in thin areas such as an ankle, and it is not suitable for diagnosing an image. Therefore, this study use copper filters made with 3D printers to increase image quality in the Long-bone inspection. A copper filter was manufactured in consideration of the overall thickness of the lower part. The experiment was conducted in anterior-posterior (AP) and lateral (LAT) positions, depending on the presence or absence of the filter. 5x5 pixels of region of interest (ROI) were selected from the pelvis, knee, and ankle areas. X-rays were irradiated under the conditions of 70 kVp and 40 mAs for AP, 80 kVp, and 63 mAs for lat when without filters, 90 kVp and 80 mAs for AP, 90 kVp and 100 mAs for lat when with filters. signal to noise ratio(SNR) ratio and contrast to noise (CNR) values were measured 1106.38, 14.34 before applying the filter and 1189.32, 70.43 after the filter. For the knee area, 650.44, 97.61 before applying the filter, and 1013.17, 444.24 after applying the filter. For the ankle area, 206.65, 23.68 before applying the filter and 993.50, 136.11 after applying the filter. In the Long-bone examination, SNR and CNR were greatly measured when the filter was applied, confirmed the availability of using the copper additional filter.

Evaluation of the Small Field of for the Detector Type Medical Linear Accelerator (의료용 선형가속기의 소조사면에 대한 검출기 종류에 따른 평가)

  • Lee, Dong-Woon;Jung, Kang-Kyo;Shin, Gwi-Soon;Cho, Pyong-Kon
    • Journal of radiological science and technology
    • /
    • v.39 no.2
    • /
    • pp.177-184
    • /
    • 2016
  • Recently linear accelerator of radiation therapy intensity modulated radiation therapy, stereotactic radiation therapy are widely used. Such radiation treatment techniques are generally difficult to exclude the small field by using the inverse treatment plan. It is necessary to dose an accurate measurement of characteristics of the small field. Thus, using different detectors to measure the volume of the effective percentage depth dose, beam profile, and the output factor of the small field was to evaluate the dose characteristics of each detector. Experimental results for the X-ray beam 6 MV energy beam quality($PDD_{20}/PDD_{10}$) is $10{\times}10cm^2$ Diode detector is as high as 2.4% compared to Pinpoint detector. All field size to lesser effective volume of Diode detector shows that it is far better than other detectors by more than 50% of small penumbra, therefore spatial resolution far excellent. In field size $2{\times}2cm^2$ Semiflex detector was measured about 2% less than the other detector. Field size $1{\times}1cm^2$ is that there is no judgment about the validity show the difference between 20%. Field size $1{\times}1cm^2$ from the measured values of the Diode detector and Pinpoint detector showed a 13% difference. Less than field size $3{\times}3cm^2$ the feed to the difference between the output factor of the effective volume of the detector to be used for the effective volume available to the detector.

Contrast-Enhanced High-Resolution Intracranial Vessel Wall MRI with Compressed Sensing: Comparison with Conventional T1 Volumetric Isotropic Turbo Spin Echo Acquisition Sequence

  • Chae Jung Park;Jihoon Cha;Sung Soo Ahn;Hyun Seok Choi;Young Dae Kim;Hyo Suk Nam;Ji Hoe Heo;Seung-Koo Lee
    • Korean Journal of Radiology
    • /
    • v.21 no.12
    • /
    • pp.1334-1344
    • /
    • 2020
  • Objective: Compressed sensing (CS) has gained wide interest since it accelerates MRI acquisition. We aimed to compare the 3D post-contrast T1-weighted volumetric isotropic turbo spin echo acquisition (VISTA) with CS (VISTA-CS) and without CS (VISTA-nonCS) in intracranial vessel wall MRIs (VW-MRI). Materials and Methods: From April 2017 to July 2018, 72 patients who underwent VW-MRI, including both VISTA-CS and VISTA-nonCS, were retrospectively enrolled. Wall and lumen volumes, signal-to-noise ratio (SNR), and contrast-to-noise ratio (CNR) were measured from normal and lesion sites. Two neuroradiologists independently evaluated overall image quality and degree of normal and lesion wall delineation with a four-point scale (scores ≥ 3 defined as acceptable). Results: Scan coverage was increased in VISTA-CS to cover both anterior and posterior circulations with a slightly shorter scan time compared to VISTA-nonCS (approximately 7 minutes vs. 8 minutes). Wall and lumen volumes were not significantly different with VISTA-CS or VISTA-nonCS (interclass correlation coefficient = 0.964-0.997). SNR was or trended towards significantly higher values in VISTA-CS than in VISTA-nonCS. At normal sites, CNR was not significantly different between two sequences (p = 0.907), whereas VISTA-CS provided lower CNR in lesion sites compared with VISTA-nonCS (p = 0.003). Subjective wall delineation was superior with VISTA-nonCS than with VISTA-CS (p = 0.019), although overall image quality did not differ (p = 0.297). The proportions of images with acceptable quality were not significantly different between VISTA-CS (83.3-97.8%) and VISTA-nonCS (75-100%). Conclusion: CS may be useful for intracranial VW-MRI as it allows for larger scan coverage with slightly shorter scan time without compromising image quality.

Conclusions and Suggestions on Low-Dose and Low-Dose Rate Radiation Risk Estimation Methodology

  • Sakai, Kazuo;Yamada, Yutaka;Yoshida, Kazuo;Yoshinaga, Shinji;Sato, Kaoru;Ogata, Hiromitsu;Iwasaki, Toshiyasu;Kudo, Shin'ichi;Asada, Yasuki;Kawaguchi, Isao;Haeno, Hiroshi;Sasaki, Michiya
    • Journal of Radiation Protection and Research
    • /
    • v.46 no.1
    • /
    • pp.14-23
    • /
    • 2021
  • Background: For radiological protection and control, the International Commission on Radiological Protection (ICRP) provides the nominal risk coefficients related to radiation exposure, which can be extrapolated using the excess relative risk and excess absolute risk obtained from the Life Span Study of atomic bomb survivors in Hiroshima and Nagasaki with the dose and dose-rate effectiveness factor (DDREF). Materials and Methods: Since it is impossible to directly estimate the radiation risk at doses less than approximately 100 mSv only from epidemiological knowledge and data, support from radiation biology is absolutely imperative, and thus, several national and international bodies have advocated the importance of bridging knowledge between biology and epidemiology. Because of the accident at the Tokyo Electric Power Company (TEPCO)'s Fukushima Daiichi Nuclear Power Station in 2011, the exposure of the public to radiation has become a major concern and it was considered that the estimation of radiation risk should be more realistic to cope with the prevailing radiation exposure situation. Results and Discussion: To discuss the issues from wide aspects related to radiological protection, and to realize bridging knowledge between biology and epidemiology, we have established a research group to develop low-dose and low-dose-rate radiation risk estimation methodology, with the permission of the Japan Health Physics Society. Conclusion: The aim of the research group was to clarify the current situation and issues related to the risk estimation of low-dose and low-dose-rate radiation exposure from the viewpoints of different research fields, such as epidemiology, biology, modeling, and dosimetry, to identify a future strategy and roadmap to elucidate a more realistic estimation of risk against low-dose and low-dose-rate radiation exposure.

Assessment of Pass Prediction of Radiologist's license on Academic Achievement through Health law Courses of 3rd Year Students in Radiology Department of College(Focus on D Health College) (전문대학교 방사선과 3학년 학생들의 보건법규학업성취도에 관한 방사선사면허 합격예측평가(D 보건 전문대학 중심으로))

  • Jung, Hong-moon;Lee, Joon-il;park, Hyong-hu;won, Do-yeon;Jung, Jae-eun
    • Journal of the Korean Society of Radiology
    • /
    • v.12 no.4
    • /
    • pp.533-539
    • /
    • 2018
  • The National Competency Standard (NCS) is being implemented on the basis of a college of higher education. The college offers intensive education by organizing three areas of knowledge, skills and attitudes so that students can perform their full capacity at the same time as graduating in industrial field. Health Department at the College has been training for a variety of medical personnel, including medical technician regions. Especially, the medical technician and medical sector must be licensed to work in the medical field. Therefore, passing the national examination license is a prerequisite for employment. In this study, the health law scores of the third grade students (about 200 students) of the radiology department of D College were analyzed at weekly intervals. The weekly score acquisition can be predict the pattern of student class achievement of individual students. Furthermore, these results can predict the possibility of passing the radiation license examination for individual students.

Statistical analysis of national examination for radiological technologists in convergence perspective (통계분석을 통한 융합적 관점에서 분석한 방사선사 국가시험)

  • Choi, Kyoungho;Cho, Jung Keun
    • Journal of the Korea Convergence Society
    • /
    • v.8 no.7
    • /
    • pp.93-99
    • /
    • 2017
  • Necessity of adjustment in level of difficulty of national examination for radiological technologists is being brought up. However, objective reasons are required to make those arguments more valid. Therefore in this research, result of national examination for radiological technologists under present system was analyzed in more convergence perspective via statistical analysis. This will provide basic data which is applicable when system of national examination for radiological technologists undergo improvements. For this, statistical analysis such as descriptive statistics and correlation analysis was conducted using SPSS program. Results are as follow. First, ratio of successful applicants for radiological technologists was highly fluctuant relative to other national examinations like doctor, nurse, physical therapist, etc. Second, level of difficulty and discernment of national examination for radiological technologists were differentiated from other examinations like doctor, nurse, physical therapist. Third, the 43th examination for radiological technologists conducted in 2015 had the highest discernment as 0.41, despite of lowest level of difficulty as 89.2, for radiologic applications. The results of this research is expected to be used as basic data when system of national examination for radiological technologists undergo improvements, in accordance with increased supplying plan of work-forces in medical radiological technologists.

Investigation of Ultrasound Examination by Radiological Technologist (방사선사의 초음파검사업무 실태조사)

  • Jeong, Bong-Jae;Ji, Tae-Jeong
    • Journal of the Korean Society of Radiology
    • /
    • v.15 no.7
    • /
    • pp.1031-1040
    • /
    • 2021
  • In this study, the actual condition of ultrasound examination was conducted for radiological technologist working across the country. The measuring tool of the study was a questionnaire, and it was targeted to radiological technologist engaged in ultrasound examination at medical institutions located across the country from February 01 to July 31, 2021. In consideration of the COVID-19 situation, 431 questionnaires suitable for research were analyzed using the SPSS/PC Ver 18.0 program using email and SNS in a non-face-to-face manner. The general characteristics of study subjects, ultrasound examination job characteristics, and job satisfaction factors were analyzed using descriptive statistics. As a result of analyzing the job characteristics of radiological technologist who perform ultrasound examination as overall job satisfaction, the overall job satisfaction was 3.30 ± 0.56. The job satisfaction level of radiological technologist performing ultrasound examinations was higher than the average of 3.0 points, indicating a higher job satisfaction level than the average. Since insurance coverage for ultrasound examinations started, many radiological technologists have been very interested in ultrasound examination work. Therefore, the Korean radiological technologists of Association and radiological technolgists engaged in ultrasound examination more attention and effort should be put into strengthening professionalism.

Development and Evaluation of the Usefulness for Hoffman Brain Phantom Based on 3D Printing Technique (3D 프린팅 기법 기반의 Hoffman Brain 팬텀 개발 및 유용성 평가)

  • Park, Hoon-Hee;Lee, Joo-Young
    • Journal of radiological science and technology
    • /
    • v.42 no.6
    • /
    • pp.441-446
    • /
    • 2019
  • The purpose of this paper is to recognize the usefulness of the Phantom produced with 3D printing technology by reproducing the original phantom with 3D printing technology. Using CT, we obtained information from the original phantom. The acquired file was printed by the SLA method of ABS materials. For inspection, SPECT/CT was used to obtain images. We filled the both Phantom with a solution mixed with 99mTcO4 1 mCi in 1 liter of water and acq uired images in accordance with the standard protocol. Using Image J, the SNR for each slice of the image was obtained. As a reference images, AC images were used. For the analysis of acquired images, ROI was set in the White mater and Gray mater sections of each image, and the average Intensity Value within the ROI were compared. According to the results of this study, 3D printed phantom's SNR is about 0.1 higher than the conventional phantom. And the ratio of Intensity Value was shown in the original 1 : 3.4, and the printed phantom was shown to be 1 : 3.2. Therefore, if Calibration Value is applied, It is assumed that it can be used as an alternative to the original.

Radioprotective Effect of Ascorbate in the Liver of ${\gamma}-Irradiated$ Mice (Ascorbate의 방사선 보호효과에 관한 연구)

  • Kim, Dong-Yun;Park, Young-Soon
    • Journal of radiological science and technology
    • /
    • v.23 no.1
    • /
    • pp.81-89
    • /
    • 2000
  • In the present study, to determine whether the ascorbate protect against radiation damage and the possible relationship among the radioprotective effects and antioxidant actions, the effects of ascorbate(240 mg/kg, i.p) pretreatment of mice on the survival ratio, splenic weight, major antioxidant enzymes(SOD, catalase and glutathione peroxidase) activities, glutathione contents and lipid peroxidation in the liver were examined for 2 weeks after whole-body ${\gamma}-irradiation$(6.5 Gy). The 30-day survival ratio Increased from 10% to 47% for mice treated with ascorbate. The ascorbate decreased the extent of loss in splenic weight and stimulated recovery of splenic weight in irradiated mice(p<0.01). On the day of 14 after ${\gamma-irradiation}$, the ascorbate pretreatment produced a slight increase of antioxidant enzymes activities and significantly increased reduced glutathione(GSH) contents(P<0.05) in the liver compared with non-treated group. Pretreatment with the ascorbate significantly decreased GSSG/total GSH ratio(p<0.05) without the change of GSSG in the liver and inhibited the radiation-induced increase in the hepatic malondialdehyde levels(p<0.05). In these results, we found that its radioprotective effect by protecting antioxidant enzyme activities and glutathione contents from radiation induced a decrease, and thereby suppressing lipid peroxidation which is induced by free radicals.

  • PDF