• Title/Summary/Keyword: Department of Optometry

Search Result 305, Processing Time 0.025 seconds

Effects of Myopia Alleviation Lenses in accordance with Parents' Refractive Errors (부모의 굴절이상에 따른 근시완화렌즈 효과)

  • Cho, Yoon Chul;Kang, JoongGu;Leem, Hyun Sung
    • The Korean Journal of Vision Science
    • /
    • v.20 no.4
    • /
    • pp.569-577
    • /
    • 2018
  • Purpose : The study looked at how effective each group wearing MyoVison lens, MC lens, and Single Vision lensdepending on their parents' myopia condition. Methods : The study observed the changeof spherical equivalent among customers, who visited between January 2010 and December 2016,of an optical shop in Incheon Metropolitan City. And we observed MyoVision 152 eyes, MC Lens 86 eyes and Single Vision lens 270 eyes. This study was conducted using SPSS ver18, which analyzes the changes in average values of MyoVision, MC Lens, and Single Vision for a year.In each group, the differences in the group were compared using the Paired T-test and then one-way ANOVA (post-hoc; Bonferroni) Results : Group-to-group comparisons showed that MyoVision and MC Lens have a shorterinhibition than Single Vision. In particular, MyoVisionand MC Lens showed different relief effects depending on the degree of refraction of parents.When both parents had normal refractive, the change between MyoVision and Single Vision lens was $-0.35{\pm}0.05D$. When the father had a refraction MC lens were $-0.36{\pm}0.14D$ more effective than Single Vision. When only the mother had refraction, the mean value between MyoVision and Single Vision lens was $-0.37{\pm}0.06D$, and the mean between MC lens and Single Vision lens was $-0.38{\pm}0.08D$. And when both parents had refraction problems, the mean value change between MyoVision and Single Vision lens was $-0.28{\pm}0.07D$, and $-0.31{\pm}0.07D$, respectively. Conclusion : MyoVision and MC Lens appeared to have no effect on the functions of mitigating myopia in within group comparisons, but MyoVision and MC Lens showed reducing myopia than Single Vision in between group.

Antimicrobial Activity of Allyl Derivate in Multi-purpose Solution as Natural Preservative (다목적용액에서 천연보존제로서의 Allyl 유도체의 항균활성)

  • Lee, Ji-Young;Suh, Seung-Kyo;Sung, Duk-Yong;Youk, Do-Jin;Lee, Koon-Ja;Chung, Jae-Yong
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.14 no.3
    • /
    • pp.95-102
    • /
    • 2009
  • Purpose: The purpose of this study is to investigate antimicrobial activity of ally derivative of garlic against eye diseases, and to get basic data for an application development of the derivative, as a natural preservative, to multi-purpose solution (MPS). Methods: Antimicrobial activity of allyl derivative of garlic, diallyl sulfide (DAS), against Pseudomonas aeruginosa (P. aeruginosa) and Staphyloccus aereus (S. aereus) was determined. After DAS treatment in MPS of no microbial activity, its growth inhibition effect to bacteria was also determined. Results: DAS concentrations of $IC_{50}$ against P. aeruginosa and S. aereus were found when both bacteria were treated with DAS concentration of 0.25% and 0.64%, respectively. At MPS test, a product from Company A did not show any effects against both bacteria, but one from Company B showed antimicrobial activity against both bacteria. Antimicrobial activity test of the product from Company B in MPS did not showed any significant difference on both gram-negative and gram-positive bacteria. For a trial application of antimicrobial activity of DAS as a natural preservative, DAS was added to MPS of Company A which did not show any antimicrobial activity at treated concentration. Addition of DAS into MPS of Company A resulted in antimicrobial activity of DAS, which suggested a possible application of DAS as a germicide for contact lenses. Conclusions: This study showed allyl derivative of garlic has antimicrobial activity against both P. aeruginosa and against S. aereus, but more effects on P. aeruginosa. The result suggests that allyl derivative derived from garlic can be developed to a preservative of MPS as a natural substance.

  • PDF

Amoebicidal Effect of Nephrite-containing Contact Lens Storage Case (연옥이 첨가된 콘택트렌즈 보관용기의 항아메바 효과)

  • Jung, Jae Woo;Lee, Jong Heon;Park, Sung Hee;Yu, Hak Sun;Kim, Yoon Kyung;Lee, Ji-Eun
    • Journal of The Korean Ophthalmological Society
    • /
    • v.58 no.5
    • /
    • pp.509-515
    • /
    • 2017
  • Purpose: To compare the amoebicidal effects of nephrite containing contact lens (CL) storage cases with conventional CL storage cases. Methods: Acanthamoeba lugdunensis were inoculated onto 5% nephrite containing CL storage cases as well as conventional CL storage cases both with and without silicone hydrogel contact lenses (SHCLs). Then the amount of Acanthamoeba proliferation on CL storage cases and the number of adherent Acanthamoeba on SHCLs were determined and compared. The effects of multipurpose solution (MPS) with and without 1% or 5% nephrite solution on Acanthamoeba adhesion were analyzed. Results: Nephrite containing CL storage cases showed more inhibitory effects on Acanthamoeba proliferation (p = 0.02) and significantly reduced the number of adherent Acanthamoeba on SHCLs compared with conventional CL storage cases, regardless of SHCLs generation (p = 0.001, p = 0.001 and p < 0.001, respectively). The number of adherent Acanthamoeba on the first generation of SHCLs was significantly reduced by MPS with 1% and 5% nephrite solutions (p = 0.03 and p = 0.004, respectively), but the numbers for the second and third generation SHCLs were not. Conclusions: Nephrite could be used as a new additive component for CL storage cases and multipurpose solutions to improve the disinfection effects on Acanthamoeba.

Study on the Scan Field of Modified Octupole and Quadrupole Deflector in a Microcolumn (마이크로칼럼에서 변형된 4중극 디플렉터와 8중극 디플렉터의 스캔 영역 비교)

  • Kim, Young Chul;Kim, Ho-Seob;Ahn, Seong Joon;Oh, Tae-Sik;Kim, Dae-Wook
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.11
    • /
    • pp.1-7
    • /
    • 2018
  • In a microcolumn, a miniaturized electrostatic deflector is often adopted to scan an electron beam. Usually, a double octupole deflector is used because it can avoid excessive spherical aberrations by controlling the electron beam path close to the optical axis of the objective lens and has a wide scan field. Studies on microcolumns have been performed to improve the low throughput of an electron column through multiple column applications. On the other hand, as the number of microcolumns increases, the number of wires connected to the components of the microcolumn increases. This will result in practical problems during the process of connecting the wires to electronic controllers outside of the vacuum chamber. To reduce this problem, modified quadrupole and octupole deflectors were examined through simulation analysis by selecting an ultraminiaturized microcolumn with the Einzel lens eliminated. The modified deflectors were designed changing the size of each electrode of the conventional Si octupole deflector. The variations of the scan field and electric field strength were studied by changing the size of active electrodes to which the deflection voltage was to be applied. The scan field increased linearly with increasing deflection voltage. The scan field of the quadrupole deflector and the electric field strength at the center were calculated to be approximately 1.3 ~ 2.0 times larger than those of the octupole deflector depending on the electrode size.

Comparison of Autorefraction and Refraction with iTrace for Elementary School Children (초등학생의 자동안굴절계와 iTrace로 측정한 굴절검사 값의 비교)

  • Kim, Hyojin;Lee, Koon-Ja;Kim, Sam-Yi;Kim, Se-Rom
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.15 no.1
    • /
    • pp.99-104
    • /
    • 2010
  • Purpose: Difference of refraction result from the method of autorefraction and iTrace were investigaged for the children of elementary school in Asan City. In iTrace method. exclusion of accommodation without cycloplegia was used. Methods: Manifest refractive stale of 42 eyes of 12~13 years old were measured using autorefractor and iTrace. Refractions of far (more than 5 m) and ncar (30 cm) vision were measured using iTrace. All data showed that the spherical equivalent were classified as being in the group 1 (-0.50D < ~ < +1.00D) and 2 (below -0.50D) according 10 refractive errors. Results: Mean spherical equivalent using autorefractor and iTrace (far and near vision) were -1.08D, -0.29D and -2.34D, respectively (p<0.01). Compared with the far vision using iTrace, autorefraction was measured the myopia with -0.50D ~ -1.00D in 52.4% of total eyes. Autorefraction also statistical significant were measured a more myopia than the far vision using iTrace in group I and 2. Conclusions: The difference of refractive errors between autorefraction and iTrace, objective refraction were measured with far vision of more than 5 m were -0.79D. Autoreftaction showed statistically decreased refraction errors than iTrace with far vision.

Fabrication and Performance Evaluation of MR-16 Lamp Series with Narrow Angular Distribution of Luminous Intensity Using an Aspherical Planar-convex 2×2 Fly-eye Lens Type (평면-비구면 2×2 fly-eye 렌즈형태의 2차 렌즈를 사용한 고효율의 좁은 배광각을 갖는 MR-16 램프 시리즈 제작 및 성능평가)

  • Chu, Kyung-duk;Ryu, Jae Myung;Hong, Chun-Gang;Jeong, Youn Hong;Jo, Jae Heung
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.8
    • /
    • pp.25-33
    • /
    • 2017
  • This paper reports the optical design of the MR-16 lamp series with a LED second lens and an aspherical plano-convex lens suitable for a simple and rapid injection molding fabrication method. The fabrication and performance evaluation of the MR-16 lamp series, which was designed with a narrow angular distribution of luminous intensity, were conducted to replace halogen lamps with LED lamps. Four types of LED lamps were fabricated, which have angular distributions of luminous intensity of $22.4^{\circ}$, $31.1^{\circ}$, $37.3^{\circ}$, and $59.9^{\circ}$ and luminous efficiencies of 76.5 lm/W, 75.2 lm/W, 72.0 lm/W, and 77.8 lm/W, respectively, while their spreading angles with an illuminance uniformity of 81% were $3^{\circ}$, $15^{\circ}$, $22^{\circ}$, and $49^{\circ}$, respectively. After eliminating a yellow tail of the LED lamps using a diffusion sheet, the angular distributions of the luminous intensity were measured to be $20.8^{\circ}$, $31.5^{\circ}$, $37.8^{\circ}$, and $68.7^{\circ}$.

Relationship of Refractive and Anatomical Changes on Eyes after Alcohol Ingestion (알코올 섭취에 의한 눈의 굴절변화와 해부학적 변화와의 관계)

  • Kim, Jung-Ouk;Moon, Byeong-Yeon;Cho, Hyun Gug
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.15 no.2
    • /
    • pp.195-199
    • /
    • 2010
  • Purpose: This study was to investigate the relevance between refractive and anatomical changes temporarily on the eyes after alcohol ingestion. Methods: Eight subjects (16 eyes) which were $24.5{\pm}1.5$ aged males drunk the alcohol of 0.42 g per kg of body weight within 30 minutes. Refractive errors, the radius of corneal curvature, corneal thickness, pupillary size, intraocular pressure, and the length of the ocular axis at 1 h, 4 h, and 24 h after alcohol ingestion were compared with them of non-alcoholic state. Results: At 1 h after alcohol ingestion, breath alcohol concentration was the highest (p<0.001), more negative spherical power was needed (p<0.05) for correction, pupillary diameter was decreased (p<0.05), intraocular pressure was decreased (p<0.001), and the length of the ocular axis was increased compared with each one of non-alcoholic state. At 4 h after alcohol ingestion, all anatomical changes were the same tendency as at 1 h after alcohol ingestion. But at 24 h after alcohol ingestion, both refractive changes and anatomical changes were not significant compared with them of non-alcoholic state. Conclusions: Temporary changes of refractive error after alcohol ingestion may be related with decrease of intraocular pressure and increase of the length of ocular axis.

The Study on Relation between Asthenopia of Lateral Phoria and Fusional Reserve (수평사위의 안정피로와 융합여력과의 관계)

  • Kim, Jung-Hee;Ryu, Kyung-Ho;Kim, In-Suk
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.11 no.4
    • /
    • pp.329-335
    • /
    • 2006
  • The aim of this study was to evaluate the relation between Asthenopia of near lateral phoria and fusional reserve and also to provide fundamental clinical data. A total of 97 subjects, aged between 17 and 35 years old, who had no strabismus, an eye trouble or whole body disease, were examined nacked visual acuity, corrected visual acuity, corrected diopter, phoria, fusional reserve tests from October of 2005 to July of 2006. We excluded 8 subjects for the following reasons: if they had an amblyopia affecting binocular vision or inaccurate data. After these exclusions, 87 subjects remained. The results were as follow. According to interview results was that in near works, exophoria and esophoria with asthenopia was 59.6%, 64.7%, and 52.6% respectively. The subjects who have exophoria of $0-6{\Delta}$ in the range of normal state was 19.1%. The subjects who have exophoria of $7{\Delta}$ over in the range of abnormal state was 80.9%. The fusional reserve was in inverse proportion to phoria. The fusional reserve was twice over of phoria were 30.3%, and twice under were 69.7%. The asthenopia complain persons were 33.9% with the twice over fusional reserve of phoria. The asthenopia no complain persons were 66.1% with the twice under fusional reserve of phoria. In conclusion, our research has shown conclusively that there is a link between asthenopia of lateral phoria and fusional reserve and we also find that fusional reserve must be examined when we prescribe for a patient who has phoria.

  • PDF

A Study on the Clinical Practice Satisfaction of Ophthalmic Optics Students and Optical Shop Owners (임상실습에 대한 안경광학과 학생들과 실습업체의 만족도에 관한 연구)

  • Lee, Ok-Jin;Jung, Se-Hoon;Shin, Jin-Ah
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.16 no.4
    • /
    • pp.363-373
    • /
    • 2011
  • Purpose: To establish basic data for effective management and quality improvement on clinical practice by investigating the clinical practice satisfaction of ophthalmic optics students and optical shop owners. Methods: A survey was administered for 281 students with experience in clinical practices and 105 optical shop owners regarding satisfaction of ophthalmic optics students and optical shops. And a statistical analysis was performed on the survey results. Results: 92.% (97 shops) of optical shop owners responded that clinical practice was necessary and there was a significant difference (p=0.004) according to gender. 4 weeks was the preferred length of practice period (53.3%) and there was a significant difference according to the size of the optical shops (p=0.000). Clinical practice satisfaction of students was 3.50 ${\pm}$ 0.68 and satisfaction for clinical practice program, clinical practice time and clinical practice shop (3.74 ${\pm}$ 0.80) were the highest and there was a significant difference according to the age of the students (p<0.05). Clinical practice satisfaction for optical shops was 4.08 ${\pm}$ 0.64 which is higher than student satisfaction. Satisfaction for clinical practice program was (4.17 ${\pm}$ 0.54) was the highest. Conclusions: To maximize the effects of clinical practice, a clinical practice program reflecting the satisfaction of students and optical shops is required and further research and attention are required.

Measurement of minimum line width of an object fabricated by metal 3D printer using powder bed fusion type with stainless steal powder (스테인리스강을 사용한 분말 적층 용융 방식의 금속 3차원 프린터에서 제작된 물체의 최소 선폭 측정)

  • Son, BongKuk;Jeong, Youn Hong;Jo, Jae Heung
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.10
    • /
    • pp.346-351
    • /
    • 2018
  • Metal three-dimensional (3D) printing technologies are mainly classified as powder bed fusion (PBF) and direct energy deposition (DED) methods according to the method of application of a laser beam to metallic powder. The DED method can be used to fabricate fine and hard 3D metallic structures by applying a strong laser beam to a thin layer of metallic powder. The PBF method involves slicing 3D graphics to be a certain height, laminating metal powders, and making a 3D structure using a laser. While the DED method has advantages such as laser cladding and metallic welding, it causes problems with low density when 3D shapes are created. The PBF method was introduced to address the structural density issues in the DED method and makes it easier to produce relatively dense 3D structures. In this paper, thin lines were produced by using PBF 3D printers with stainless-steel powder of roughly $30{\mu}m$ in diameter with a galvano scanner and fiber-transferred Nd:YAG laser beam. Experiments were carried out to find the optimal conditions for the width of a line depending on the processing times, laser power, spot size, and scan speed. The optimal conditions were two scanning processes in one line structure with a laser power of 30 W, spot size of $28.7{\mu}m$, and scan speed of 200 mm/s. With these conditions, a minimum width of about $85.3{\mu}m$ was obtained.