• Title/Summary/Keyword: Dental implantology

Search Result 74, Processing Time 0.022 seconds

Anesthetic efficacy of buffered 4% articaine for mandibular first molar infiltration: a crossover clinical trial

  • Kalliopi Manta;Nikolaos Dabarakis;Theodoros Lillis;Ioannis Fotopoulos
    • Journal of Dental Anesthesia and Pain Medicine
    • /
    • v.23 no.3
    • /
    • pp.135-141
    • /
    • 2023
  • Background: The limited studies on the effect of buffering on the clinical efficacy of articaine have reported controversial results. The purpose of this study was to clinically compare the pain of injection, anesthetic success, onset, and duration of pulpal anesthesia of buffered 4% articaine with epinephrine 1:100000 versus a non-buffered 4% articaine with epinephrine 1:100000 formulation for buccal infiltration of the mandibular first molar. Methods: Sixty-three volunteers were enrolled in the study. All volunteers received two injections consisting of a single mandibular first molar buccal infiltration with 1.8 ml of 4% articaine with epinephrine 1:100000 and 1.8 ml of 4% articaine with epinephrine 1:100000 buffered with 8.4% sodium bicarbonate. The infiltrations were applied in two separate appointments spaced at least one week apart. After injection of the anesthetic solution at the examined site, the first molar was pulp-tested every 2 min for the next 60 min. Results: Successful pulpal anesthesia was recorded in 69.8% of cases using non-buffered articaine solution and 76.2% of cases using buffered articaine solution, with no significant difference between the formulations (P = 0.219). The mean time of anesthesia onset for the volunteers with successful anesthetic outcome in both formulations (n = 43) was 6.6 ± 1.6 min for the non-buffered articaine solution and 4.5 ± 1.6 min for the buffered solution, which differed significantly (P = 0.001). In the same volunteers, the mean duration of pulpal anesthesia was 28.4 ± 7.1 min for non-buffered articaine solution and 30.2 ± 8.5 min for buffered articaine solution, with no significant difference between the formulations (P = 0.231). Considering the pain of injection, regardless of the anesthetic success, the mean values of VAS were 11.3 ± 8.2 mm for the non-buffered articaine solution and 7.8 ±6.5 mm for the buffered articaine solution, which differed significantly (P = 0.001 < 0.05). Conclusion: According to the present study, 4% articaine with epinephrine can benefit from buffering and provide better anesthetic behavior, with improved onset and less pain during injection.

Deep learning improves implant classification by dental professionals: a multi-center evaluation of accuracy and efficiency

  • Lee, Jae-Hong;Kim, Young-Taek;Lee, Jong-Bin;Jeong, Seong-Nyum
    • Journal of Periodontal and Implant Science
    • /
    • v.52 no.3
    • /
    • pp.220-229
    • /
    • 2022
  • Purpose: The aim of this study was to evaluate and compare the accuracy performance of dental professionals in the classification of different types of dental implant systems (DISs) using panoramic radiographic images with and without the assistance of a deep learning (DL) algorithm. Methods: Using a self-reported questionnaire, the classification accuracy of dental professionals (including 5 board-certified periodontists, 8 periodontology residents, and 31 dentists not specialized in implantology working at 3 dental hospitals) with and without the assistance of an automated DL algorithm were determined and compared. The accuracy, sensitivity, specificity, confusion matrix, receiver operating characteristic (ROC) curves, and area under the ROC curves were calculated to evaluate the classification performance of the DL algorithm and dental professionals. Results: Using the DL algorithm led to a statistically significant improvement in the average classification accuracy of DISs (mean accuracy: 78.88%) compared to that without the assistance of the DL algorithm (mean accuracy: 63.13%, P<0.05). In particular, when assisted by the DL algorithm, board-certified periodontists (mean accuracy: 88.56%) showed higher average accuracy than did the DL algorithm, and dentists not specialized in implantology (mean accuracy: 77.83%) showed the largest improvement, reaching an average accuracy similar to that of the algorithm (mean accuracy: 80.56%). Conclusions: The automated DL algorithm classified DISs with accuracy and performance comparable to those of board-certified periodontists, and it may be useful for dental professionals for the classification of various types of DISs encountered in clinical practice.

In vitro evaluation of a removable partial denture framework using multi-directionally forged titanium

  • Suzuki, Ginga;Shimizu, Satoshi;Torii, Mana;Tokue, Ai;Ying, Guo;Yoshinari, Masao;Hoshi, Noriyuki;Kimoto, Katsuhiko;Miura, Hiromi;Hayakawa, Tohru;Ohkubo, Chikahiro
    • The Journal of Advanced Prosthodontics
    • /
    • v.12 no.6
    • /
    • pp.369-375
    • /
    • 2020
  • PURPOSE. This study evaluated the availability of multi-directionally forged (MDF) titanium (Ti) as a component of removable partial dentures (RPDs). MDF-Ti remarkably improved the mechanical properties of RPDs due to its ultrafine-grained structure. MATERIALS AND METHODS. The wear resistance, plaque adhesion, and machinability of MDF-Ti were tested. As controls, commercially pure (CP) titanium was used for wear, plaque adhesion, and machinability tests. For wear resistance, the volume losses of the titanium teeth before and after wear tests were evaluated. Plaque adhesion was evaluated by the assay of Streptococcus mutans. In the machinability test, samples were cut and ground by a steel fissure bur and carborundum (SiC) point. An unpaired t-test was employed for the analysis of the significant differences between MDF-Ti and the control in the results for each test. RESULTS. Wear resistance and plaque adherence of MDF-Ti similar to those of CP-Ti (P>.05) were indicated. MDF-Ti exhibited significantly larger volume loss than CP-Ti in all conditions except 100/30,000 g/rpm in machinability tests (P<.05). CONCLUSION. Although the wear resistance and plaque adherence of MDF-Ti were comparable to those of controls, MDF-Ti showed better machinability than did CP-Ti. MDF-Ti could be used as a framework material for RPDs.

The retrospective study of marginal bone loss around dental implants according to different autogenous bone grafts (이식된 자가골의 종류와 형태에 따른 임플란트 변연골 흡수량에 관한 후향적 연구)

  • Kim, Tae-Yi;Kim, Ye-Mi;Kim, Ji-Youn;Kim, Myung-Rae;Kim, Sun-Jong
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.37 no.6
    • /
    • pp.483-489
    • /
    • 2011
  • Introduction: This study examined the cumulative resorption of implants placed in a severely atrophic mandible and analyzed the radiologic bone resorption in the marginal bone, after an autogenous bone graft including both block and particulates that had been harvested from the ramus and iliac crest. Materials and Methods: A retrospective study was performed on patients who had bone grafts for augmentation followed by implant installation in the mandible area from 2003 to 2008. Twelve patients (6 men and 6 women) who received 34 implants in the augmented sites were evaluated. Cumulative radiologic resorption around the implants was measured immediately, 3 months, 6 months and 12 months after implant installation surgery. Results: The installed implant in grafted bone showed 0.84 mm marginal bone resorption after 3 months and 50% total cumulative resorption after 1 year. The mean marginal bone resorption around the implant installed in the grafted bone was 0.44 mm after 3 months, 0.52 mm after 1 year, after which it stabilized. The implant survival rate was 97% (failed implant was 1/34). Marginal bone resorption of the installed implant in the autogenous onlay block bone grafts was 0.98 mm after 3 months, which was significantly higher than that of a particulated bone graft (0.74 mm) (P <0.05). Conclusion: An autogenous graft including block type and particulate type is a predictable procedure for the use of dental implants in a severely atrophic mandible. Implant placement in augmented areas show a relatively high survival and minimal bone loss, as revealed by a radiologic evaluation.

Evaluation of bone substitutes for treatment of peri-implant bone defects: biomechanical, histological, and immunohistochemical analyses in the rabbit tibia

  • dos Santos, Pamela Leticia;de Molon, Rafael Scaf;Queiroz, Thallita Pereira;Okamoto, Roberta;de Souza Faloni, Ana Paula;Gulinelli, Jessica Lemos;Luvizuto, Eloa Rodrigues;Garcia, Idelmo Rangel Junior
    • Journal of Periodontal and Implant Science
    • /
    • v.46 no.3
    • /
    • pp.176-196
    • /
    • 2016
  • Purpose: We sought to evaluate the effectiveness of bone substitutes in circumferential periimplant defects created in the rabbit tibia. Methods: Thirty rabbits received 45 implants in their left and right tibia. A circumferential bone defect (6.1 mm in diameter/4 mm depth) was created in each rabbit tibia using a trephine bur. A dental implant ($4.1mm{\times}8.5mm$) was installed after the creation of the defect, providing a 2-mm gap. The bone defect gaps between the implant and the bone were randomly filled according to the following groups: blood clot (CO), particulate Bio-Oss$^{(R)}$ (BI), and Bio-Oss$^{(R)}$ Collagen (BC). Ten animals were euthanized after periods of 15, 30, and 60 days. Biomechanical analysis by means of the removal torque of the implants, as well as histologic and immunohistochemical analyses for protein expression of osteocalcin (OC), Runx2, OPG, RANKL, and TRAP were evaluated. Results: For biomechanics, BC showed a better biological response ($61.00{\pm}15.28Ncm$) than CO ($31.60{\pm}14.38Ncm$) at 30 days. Immunohistochemical analysis showed significantly different OC expression in CO and BC at 15 days, and also between the CO and BI groups, and between the CO and BC groups at 60 days. After 15 days, Runx2 expression was significantly different in the BI group compared to the CO and BC groups. RANKL expression was significantly different in the BI and CO groups and between the BI and BC groups at 15 days, and also between the BI and CO groups at 60 days. OPG expression was significantly higher at 60 days postoperatively in the BI group than the CO group. Conclusions: Collectively, our data indicate that, compared to CO and BI, BC offered better bone healing, which was characterized by greater RUNX2, OC, and OPG immunolabeling, and required greater reversal torque for implant removal. Indeed, along with BI, BC presents promising biomechanical and biological properties supporting its possible use in osteoconductive grafts for filling peri-implant gaps.

Impact of iron deficiency anemia on chronic periodontitis and superoxide dismutase activity: a cross-sectional study

  • Chakraborty, Souvik;Tewari, Shikha;Sharma, Rajinder Kumar;Narula, Satish Chander;Ghalaut, Pratap Singh;Ghalaut, Veena
    • Journal of Periodontal and Implant Science
    • /
    • v.44 no.2
    • /
    • pp.57-64
    • /
    • 2014
  • Purpose: Both chronic periodontitis (CP) and iron deficiency anemia (IDA) induce oxidative stress in the body and cause an imbalance between reactive oxygen species and antioxidants, such as superoxide dismutase (SOD). This study explored the SOD enzyme activity of saliva and serum in CP patients with and without IDA and analyzed the impact of IDA on CP. Methods: A total of 82 patients were divided into four groups: control group (CG, 22), periodontally healthy IDA patients (IDA-PH, 20), CP patients (CP, 20), and IDA patients with CP (IDA-CP, 20). After clinical measurements and samplings, serum and salivary SOD levels were determined using an SOD assay kit. Results: IDA-CP patients exhibited a higher gingival index, bleeding on probing, probing pocket depth, and percentage (%) of sites with a clinical attachment loss (CAL) of ${\geq}6mm$ (P<0.008) than CP patients. The mean salivary and serum SOD levels were significantly lower in the IDA-PH, CP, and IDA-CP patients than in the CG group (P<0.008). A significant positive correlation between salivary and serum SOD activity was observed in IDA (P<0.05). Furthermore, serum and salivary SOD levels were significantly and negatively correlated with all periodontal parameters including the percentage of sites with CAL of 4-5 and ${\geq}6mm$ (P<0.05) except the significant correlation between salivary SOD activity and mean CAL and the percentage of sites with CAL of 4-5 mm (P>0.05) in these patients. Conclusions: Within the limits of this study, it may be suggested that IDA patients with chronic periodontitis have more periodontal breakdowns than patients with chronic periodontitis. Serum and salivary SOD activity levels were lower in the IDA-PH, CP and IDA-CP groups than in the CG. Iron deficiency anemia influenced the serum SOD activity but did not seem to affect the salivary SOD activity in these patients.

Interferon Stimulated Gene - ISG15 is a Potential Diagnostic Biomarker in Oral Squamous Cell Carcinomas

  • Laljee, Rupesh Puthenparambil;Muddaiah, Sunil;Salagundi, Basavaraj;Cariappa, Ponappa Muckatira;Indra, Adarsh Surendran;Sanjay, Venkataram;Ramanathan, Arvind
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.14 no.2
    • /
    • pp.1147-1150
    • /
    • 2013
  • Background: Cancer diagnostic biomarkers have a wide range of applications that include early detection of oral precancerous lesions and oral squamous cell carcinomas, and assessing the metastatic status of lesions. The interferon stimulated ISG15 gene encodes an ubiquitin-like protein, which conjugates to stabilize activation status of associated proteins. Hence a deregulated expression of ISG15 may promote carcinogenesis. Indeed overexpression of ISG15 has been observed in several cancers and hence it has been proposed as a strong candidate cancer diagnostic biomarker. Given the emerging relationship between malignant transformation and ISG15, we sought to examine the expression pattern of this gene in tumor biopsies of oral squamous cell carcinoma (OSCC) tissues collected from Indian patients. Materials and Methods: Total RNA isolated from thirty oral squamous cell carcinoma tissue biopsy samples were subjected to semi-quantitative RT-PCR with ISG15 specific primers to elucidate the expression level. Results: Of the thirty oral squamous cell carcinomas that were analyzed, ISG15 expression was found in twenty four samples (80%). Twelve samples expressed low level of ISG15, six of them expressed moderately, while the rest of them expressed very high level of ISG15. Conclusions: To the best of our knowledge, the results show for the first time an overexpression of ISG15 in up to 80% of oral squamous cell carcinoma tissues collected from Indian patients. Hence ISG15 may be explored for the possibility of use as a high confidence diagnostic biomarker in oral cancers.

COMPLICATIONS OF THE IMPLANT-SUPPORTED POSTERIOR MANDIBULAR SINGLE RESTORATIONS WITH MESIAL CANTILEVER (하악구치 임플란트 지지 단일수복에서 근심 캔틸레버가 임플란트 합병증에 미치는 영향)

  • Shin, He-Sung;Kim, Myung-Rae;Kim, Sun-Jong
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.35 no.4
    • /
    • pp.248-252
    • /
    • 2009
  • Purpose: This retrospective study was performed to analyze the relationship between complications of the posterior mandibular single crowns and distance from the adjacent teeth to the implant. Subjects and Methods: Of the patients who presented Ewha Womans University Mokdong Hospital & Yonsei University Dental Hospital with missing of the posterior mandibular molar and restored with implant-supported 18 Single crowns between 1996 thru 2007, 115 patients had been followed after crown delivery. The subjects were divided into complication-followed group and a control without any problems. The distance from the most distal tooth to the implant were measured. The prosthetic & biologic complications were reviewed by the cantilever distance and analyzed by abutment type, age & gender statistically using SAS version 9.1 (SAS Inc., USA). Results and Conclusion The results were as follows; 1) The posterior mandibular single crown with cantilever showed higher incidence of follow-up complications upon logistic analysis (p<0.05). 2) The prosthetic and biologic complications are related with the cantilever distance with 2.1 odds ratio and 3.39 cut-off value of specificity & sensitivity by SPSS 12.0. 3) The complications are neither significant in abutment types nor age & gender.

Drilling force and speed for mandibular trabecular bone in oral implant surgery

  • bin Kamisan, Mohammad Aimaduddin Atiq;Yokota, Kenichiro;Ueno, Takayuki;Kinoshita, Hideaki;Homma, Shinya;Yajima, Yasutomo;Abe, Shinichi;Takano, Naoki
    • Biomaterials and Biomechanics in Bioengineering
    • /
    • v.3 no.1
    • /
    • pp.15-26
    • /
    • 2016
  • Based on a survey done recently in Japan, 30 percent of the serious accidents occurred in oral implant surgery were concerned with the mandibular canal and 3/4 of them were related to drilling. One of the reasons lies in the lack of the education system. To overcome this problem, a new educational system focusing on drilling the mandibular trabecular bone has been developed mainly for dental college students in the form of an oral implant surgery training simulator that enables student to sense the reaction force during drilling. On the other hand, the conventional system uses polymeric model. Based on these systems, two approaches were proposed; the evaluation by experienced clinicians using the simulator, and experimental works on the polymeric model. Focusing on the combination of the drilling force sensed and drilling speed obtained through both approaches, the results were compared. It was found that the polymeric models were much softer especially near the mandibular canal. In addition, the study gave us an insight of the understanding in bone quality through tactile sensation of the drilling force and speed. Furthermore, the clinicians positively reviewed the simulator as a valid tool.

Bone Response to Anodized Titanium Implants in Rabbits

  • Lee, Jae-Hyun;Lee, Cheol-Won;Kim, Chang-Hyen;Pyo, Sung-Woon
    • Journal of Korean Dental Science
    • /
    • v.4 no.1
    • /
    • pp.26-32
    • /
    • 2011
  • Purpose: The quality of implant surface is one of the factors that influence wound healing of implant site and subsequently affect osseointegration. The objective of modification of the surface properties of an implant is to affect the biological consequence. The purpose of this study is to evaluate the biologic response of osseous tissue to anodized implants. Materials and Methods: Two machined titanium implants for control group were installed in a tibia of each rabbit and two anodized implants for test group were installed in the other tibia of each rabbit. At the moment the implants were installed, resonance frequency analysis (RFA) values were measured. After healing periods of 1, 2, 3, and 7 weeks, the implants were uncovered and RFA values were measured again. Removal torque was measured for one implant in the test group and one implant in the control group. Histological evaluation was executed in the other implants. Results: Both of test group and control group have the tendency of greater RFA change rate and removal torque value as healing periods became longer, but were statistically insignificant (P>0.05). However, in the case of the same healing period, the test group tended to have greater RFA change rate and removal torque than the control group (P<0.05). More active new bone formation from endosteal surface was noted on the anodized surface than machined surface in specimen after 1 week. There were no significant differences between the test group and control group in histological evaluations. Conclusion: In summary, the anodized surface showed slightly favorable results and it is postulated that it may facilitate improved stability in bone.