• 제목/요약/키워드: Dental imaging

검색결과 939건 처리시간 0.027초

Dental PACS development in Korea

  • Kim, Eun-Kyung
    • Imaging Science in Dentistry
    • /
    • 제38권4호
    • /
    • pp.189-194
    • /
    • 2008
  • Picture archiving and communication system (PACS) is an image information technology system for the transmission and storage of medical images. In Korea the first full PACS was installed at Samsung Medical Center in 1994, but, the rate of distribution was very slow. The government's approval for the medical insurance reimbursement for full PACS examinations in November 1999 became the turning point. Thereafter the number of hospitals with full PACS has steeply increased. In September of this year, PACS was installed at 906 medical institutes, including most of university hospitals and general hospitals. The first full dental PACS was installed at Wonkwang University Dental Hospital in 2002. Now ten out of eleven university dental hospitals implemented full dental PACS. The current status and technological factors of dental PACS in Korean university dental hospitals and the future perspectives of dental PACS are described. (Korean J Oral Maxillofac Radiol 2008; 38: 189-94)

  • PDF

Fungal Osteomyelitis of Temporomandibular Joint and Skull Base Caused by Chronic Otitis Media

  • Kim, Bok Eum;Park, Keun Jeong;Lee, Jung Eun;Park, YounJung;Kwon, Jeong-Seung;Kim, Seong-Taek;Choi, Jong-Hoon;Ahn, Hyung-Joon
    • Journal of Oral Medicine and Pain
    • /
    • 제45권1호
    • /
    • pp.12-16
    • /
    • 2020
  • Chronic otitis media (COM) is a chronic inflammatory disease which affects the middle ear, mastoid cavity. It presents hearing loss, ear pain, dizziness, headache, temporomandibular joint (TMJ) inflammation and intracranial complication. Intracranial complications such as skull base osteomyelitis (SBO) may occur secondary to COM due to transmission of infection by a number of possible routes. SBO is an uncommon condition with a significant morbidity and mortality if not treated in the early stages. We report a-67-year-old male patient with diabetes and untreated COM who presented atypical severe TMJ, periorbital and postmandibular pain. By computerized tomography (CT), magnetic resonance imaging (MRI) and whole body bone scan (WBBS), he was diagnosed with SBO spreading from untreated COM via infective arthritis of TMJ. Through this case, we suggest proper utilization of diagnostic imaging, especially CT or MRI for the early detection of SBO in the case of COM accompanying with the greater risk of infection developments such as diabetes.

The reliability of tablet computers in depicting maxillofacial radiographic landmarks

  • Tadinada, Aditya;Mahdian, Mina;Sheth, Sonam;Chandhoke, Taranpreet K;Gopalakrishna, Aadarsh;Potluri, Anitha;Yadav, Sumit
    • Imaging Science in Dentistry
    • /
    • 제45권3호
    • /
    • pp.175-180
    • /
    • 2015
  • Purpose: This study was performed to evaluate the reliability of the identification of anatomical landmarks in panoramic and lateral cephalometric radiographs on a standard medical grade picture archiving communication system (PACS) monitor and a tablet computer (iPad 5). Materials and Methods: A total of 1000 radiographs, including 500 panoramic and 500 lateral cephalometric radiographs, were retrieved from the de-identified dataset of the archive of the Section of Oral and Maxillofacial Radiology of the University Of Connecticut School Of Dental Medicine. Major radiographic anatomical landmarks were independently reviewed by two examiners on both displays. The examiners initially reviewed ten panoramic and ten lateral cephalometric radiographs using each imaging system, in order to verify interoperator agreement in landmark identification. The images were scored on a four-point scale reflecting the diagnostic image quality and exposure level of the images. Results: Statistical analysis showed no significant difference between the two displays regarding the visibility and clarity of the landmarks in either the panoramic or cephalometric radiographs. Conclusion: Tablet computers can reliably show anatomical landmarks in panoramic and lateral cephalometric radiographs.

Development of a new ball-type phantom for evaluation of the image layer of panoramic radiography

  • Yeom, Han-Gyeol;Kim, Jo-Eun;Huh, Kyung-Hoe;Yi, Won-Jin;Heo, Min-Suk;Lee, Sam-Sun;Choi, Soon-Chul
    • Imaging Science in Dentistry
    • /
    • 제48권4호
    • /
    • pp.255-259
    • /
    • 2018
  • Purpose: This study proposes a new ball-type phantom for evaluation of the image layer of panoramic radiography. Materials and Methods: The arch shape of an acrylic resin phantom was derived from average data on the lower dental arch in Korean adult males. Metal balls with a 2-mm diameter were placed along the center line of the phantom at a 4-mm mesiodistal interval. Additional metal balls were placed along the 22 arch-shaped lines that ran parallel to the center line at 2-mm buccolingual intervals. The height of each ball in the horizontal plane was spaced by 2.5 mm, and consequently, the balls appeared oblique when viewed from the side. The resulting phantom was named the Panorama phantom. The distortion rate of the balls in the acquired image was measured by automatically calculating the difference between the vertical and horizontal length using $MATLAB^{(R)}$. Image layer boundaries were obtained by applying various distortion rate thresholds. Results: Most areas containing metal balls (91.5%) were included in the image layer with a 50% distortion rate threshold. When a 5% distortion rate threshold was applied, the image layer was formed with a small buccolingual width along the arch-shaped center line. However, it was medially located in the temporomandibular joint region. Conclusion: The Panorama phantom could be used to evaluate the image layer of panoramic radiography, including all mesiodistal areas with large buccolingual width.

A pilot study of half-value layer measurements using a semiconductor dosimeter for intraoral radiography

  • Shun Nouchi;Hidenori Yoshida;Yusaku Miki;Yasuhito Tezuka;Ruri Ogawa;Ichiro Ogura
    • Imaging Science in Dentistry
    • /
    • 제53권3호
    • /
    • pp.217-220
    • /
    • 2023
  • Purpose: This pilot study was conducted to evaluate half-value layer (HVL) measurements obtained using a semiconductor dosimeter for intraoral radiography. Materials and Methods: This study included 8 aluminum plates, 4 of which were low-purity (less than 99.9%) and 4 high-purity (greater than 99.9%). Intraoral radiography was performed using an intraoral X-ray unit in accordance with the dental protocol at the authors' affiliated hospital: tube voltage, 60 kVp and 70 kVp; tube current, 7 mA; and exposure time, 0.10 s. The accuracy of HVL measurements for intraoral radiography was assessed using a semiconductor dosimeter. A simple regression analysis was performed to compare the aluminum plate thickness and HVL in relation to the tube voltage (60 kVp and 70 kVp) and aluminum purity (low and high). Results: For the low-purity aluminum plates, the HVL at 60 kVp (Y) and 70 kVp (Y) was significantly correlated with the thickness of the aluminum plate (X), with Y=1.708+0.415X (r=0.999, P<0.05) and Y=1.980+0.484X (r=0.999, P<0.05), respectively. Similarly, for the high-purity aluminum plates, the HVL at 60 kVp (Y) and 70 kVp (Y) was significantly correlated with the plate thickness(X), with Y=1.696+0.454X (r=0.999, P<0.05) and Y=1.968+0.515X (r=0.998, P<0.05), respectively. Conclusion: This pilot study examined the relationship between aluminum plate thickness and HVL measurements using a semiconductor dosimeter for intraoral radiography. Semiconductor dosimeters may prove useful in HVL measurement for purposes such as quality assurance in dental X-ray imaging.

Deep-learning performance in identifying and classifying dental implant systems from dental imaging: a systematic review and meta-analysis

  • Akhilanand Chaurasia;Arunkumar Namachivayam;Revan Birke Koca-Unsal;Jae-Hong Lee
    • Journal of Periodontal and Implant Science
    • /
    • 제54권1호
    • /
    • pp.3-12
    • /
    • 2024
  • Deep learning (DL) offers promising performance in computer vision tasks and is highly suitable for dental image recognition and analysis. We evaluated the accuracy of DL algorithms in identifying and classifying dental implant systems (DISs) using dental imaging. In this systematic review and meta-analysis, we explored the MEDLINE/PubMed, Scopus, Embase, and Google Scholar databases and identified studies published between January 2011 and March 2022. Studies conducted on DL approaches for DIS identification or classification were included, and the accuracy of the DL models was evaluated using panoramic and periapical radiographic images. The quality of the selected studies was assessed using QUADAS-2. This review was registered with PROSPERO (CRDCRD42022309624). From 1,293 identified records, 9 studies were included in this systematic review and meta-analysis. The DL-based implant classification accuracy was no less than 70.75% (95% confidence interval [CI], 65.6%-75.9%) and no higher than 98.19 (95% CI, 97.8%-98.5%). The weighted accuracy was calculated, and the pooled sample size was 46,645, with an overall accuracy of 92.16% (95% CI, 90.8%-93.5%). The risk of bias and applicability concerns were judged as high for most studies, mainly regarding data selection and reference standards. DL models showed high accuracy in identifying and classifying DISs using panoramic and periapical radiographic images. Therefore, DL models are promising prospects for use as decision aids and decision-making tools; however, there are limitations with respect to their application in actual clinical practice.

Applications of Optical Imaging System in Dentistry

  • Eom, Joo Beom;Park, Anjin
    • Medical Lasers
    • /
    • 제9권1호
    • /
    • pp.25-33
    • /
    • 2020
  • Optical-based imaging technology has high resolution and can assess images in real time. Numerous studies have been conducted for its application in the dental field. The current research introduces an oral camera that includes fluorescent imaging, a second study examining a 3D intraoral scanner applying a confocal method and a polarization structure that identifies the 3D image of a tooth, and finally, an optical coherence tomography technique. Using this technique, we introduce a new concept 3D oral scanner that simultaneously implements 3D structural imaging as well as images that diagnose the inside of teeth. With the development of light source technology and detector technology, various optical-based imaging technologies are expected to be applied in dentistry.

Clival lesion incidentally discovered on cone-beam computed tomography: A case report and review of the literature

  • Jadhav, Aniket B.;Tadinada, Aditya;Rengasamy, Kandasamy;Fellows, Douglas;Lurie, Alan G.
    • Imaging Science in Dentistry
    • /
    • 제44권2호
    • /
    • pp.165-169
    • /
    • 2014
  • An osteolytic lesion with a small central area of mineralization and sclerotic borders was discovered incidentally in the clivus on the cone-beam computed tomography (CBCT) of a 27-year-old male patient. This benign appearance indicated a primary differential diagnosis of non-aggressive lesions such as fibro-osseous lesions and arrested pneumatization. Further, on magnetic resonance imaging (MRI), the lesion showed a homogenously low T1 signal intensity with mild internal enhancement after post-gadolinium and a heterogeneous T2 signal intensity. These signal characteristics might be attributed to the fibrous tissues, chondroid matrix, calcific material, or cystic component of the lesion; thus, chondroblastoma and chondromyxoid fibroma were added to the differential diagnosis. Although this report was limited by the lack of final diagnosis and the patient lost to follow-up, the incidental skull base finding would be important for interpreting the entire volume of CBCT by a qualified oral and maxillofacial radiologist.

Three-dimensional imaging of progressive facial hemiatrophy (Parry-Romberg syndrome) with unusual conjunctival findings

  • Balan, Preethi;Gogineni, Subhas Babu;Shetty, Shishir Ram;D'souza, Deepa
    • Imaging Science in Dentistry
    • /
    • 제41권4호
    • /
    • pp.183-187
    • /
    • 2011
  • Progressive hemifacial atrophy, also known as Parry-Romberg syndrome, is an uncommon degenerative condition which is poorly defined. It is characterized by a slow and progressive atrophy affecting one side of the face. The onset usually occurs during the first two decades of life. Characteristically, the atrophy progresses slowly for several years, and then it becomes stable. Ophthalmic involvement is common, with progressive enophthalmos which is a frequent finding. Cutaneous pigmentation is common in such conditions, however its extension to the conjunctiva is rarely reported. We report a case of Parry Romberg syndrome with characteristic clinical and radiographic presentation accompanied with rare ocular findings. The clinical features, radiological findings, and differential diagnoses to be considered, and the available treatment options are discussed in this report.