• 제목/요약/키워드: Dental casting alloy

검색결과 87건 처리시간 0.027초

원심 주조한 니켈-크롬 합금의 성량 변화 및 주조 온도에 따른 산화물 측정 (Composition of nickel-chromium alloy on the centrifugal casting and the influence of quantitative of oxides on the casting temperature)

  • 김원수
    • 대한치과기공학회지
    • /
    • 제34권4호
    • /
    • pp.361-368
    • /
    • 2012
  • Purpose: The aim of this study was to analysis the composition on the centrifugal casting and the oxide on the casting temperature. Methods: The nickel based alloy were used in this study. Wax pattern specimens (10*10*2) were invested with phosphate-bonded investment in metal rings, the liquid/powder ratio and overall burn-out schedules for these investments were followed in accordance with the manufacturer's instructions. After casting, the alloy specimens were evaluated as regards composition(EPMA). The casting temperatures were as follows: $1400^{\circ}C$ and $1700^{\circ}C$. The quantitative analysis of oxides were scanning electron microscope(SEM), energy dispersive spectroscopy(EDS) and line scanning. Results: Nearer the injection lines showed that there is a large amount of nickel. Quantitative of oxides of Ni-Cr alloy cast from $1400^{\circ}C$ is lager than Ni-Cr alloy cast from $1700^{\circ}C$. Conclusion: Casting when using a centrifugal casting machine centrifugal force affects the composition of the alloy. The higher the temperature, the amount of oxide that is generated many.

치과 도재용착 주조관용 비귀금속 합금의 반복주조가 기계적 특성 및 미세조직에 미치는 영향 (A Study on How Cyclic Casting of Base Metal Alloy for Dental Ceramic Crown May Effects upon Its Mechanical Properties and Microstructure)

  • 최운재;신무학;정희선;고명원
    • 대한치과기공학회지
    • /
    • 제25권1호
    • /
    • pp.9-20
    • /
    • 2003
  • Using a nickel-chrome casting alloy called 'Rexillium V' which is also available as base metal alloy for dental ceramic crown, 4 types of mixtures(A, B, C, D) with old and new metal were prepared for cyclic casting. The results of cyclic casting can be outlined as follows: 1. For Vickers hardness after casting, specimen A and D tended to have lower hardness in the course of cyclic casting, while specimen B and C tended to higher hardness. 2. The results of X-ray diffraction analysis showed that major crystal phase contained nickelchrome compounds and carbide. 3. The observation results of SEM photographs after cyclic casting show that there was a significant tendency to have similar structures among experimental groups. 4. The results of EDX analysis after cyclic casting showed that there were little differences in chemical composition between parent metal and base metal alloy. Although industrial nickel-chrome cast alloy did not show any significant change in material properties even through cyclic casting over several times, it is recommended that more there be more in-depth studies on how to detect any potential corrosion, discoloration and toxication of dental ceramic crown implanted in patient's oral cavity.

  • PDF

TiN피막 코팅된 치과주조용 합금의 부식거동 (Corrosion Behaviors of TiN Coated Dental Casting Alloys)

  • 조호형;박근형;김원기;최한철
    • 대한금속재료학회지
    • /
    • 제47권2호
    • /
    • pp.129-137
    • /
    • 2009
  • Corrosion behaviors of TiN coated dental casting alloys have been researched by using various electrochemical methods. Three casting alloys (Alloy 1: 63Co-27Cr-5.5Mo, Alloy 2: 63Ni-16Cr-5Mo, Alloy 3: 63Co-30Cr-5Mo) were prepared for fabricating partial denture frameworks with various casting methods; centrifugal casting(CF), high frequency induction casting(HFI) and vacuum pressure casting(VP). The specimens were coated with TiN film by RF-magnetron sputtering method. The corrosion behaviors were investigated using potentiostat (EG&G Co, 263A. USA) in 0.9% NaCl solution at $36.5{\pm}1^{\circ}C$. The corrosion morphologies were analyzed using FE-SEM and EDX. Alloy 1 and Alloy 2 showed the ${\alpha}-Co$ and ${\varepsilon}-Co$ phase on the matrix, and it was disappeared in case of TiN coated Alloy 1 and 2. In the Alloy 3, $Ni_2Cr$ second phases were appeared at matrix. Corrosion potentials of TiN coated alloy were higher than that of non-coated alloy, but current density at passive region of TiN coated alloy was lower than that of non-coated alloy. Pitting corrosion resistances were increased in the order of centrifugal casting, high frequency induction casting and vacuum pressure casting method from cyclic potentiodynamic polarization test.

분말야금공법으로 제조된 CAD/CAM용 Co-Cr-Mo 합금의 미세조직 및 기계적 특성 (Microstructure and Mechanical Properties of Co-Cr-Mo alloy for CAD/CAM Applications fabricated by Powder Metallurgy Process)

  • 차성수
    • 대한치과기공학회지
    • /
    • 제37권4호
    • /
    • pp.235-242
    • /
    • 2015
  • Purpose: The aims of this study are compare with microstructure and mechanical properties of Co-Cr-Mo alloys fabricated by powder metallurgy(P/M) process and casting process respectively. Methods: Microstructure and micro-hardness were tested by SEM and Vickers Hardness Tester. The sintered specimen was produced by furnace-coolling after sintering, however the casting specimen were produced thru air-cooling and water-cooling after the casting. For observation of phase transformation during sintering, DSC analyzing was carried out. Results: Mean pore size of sintered Co-Cr-Mo alloy was $4.32{\mu}m$ and that of casting alloy was $1.63{\mu}m$. Hardness of sintered alloy was lower than water-quenched casting alloy. Conclusion: Proper sintering temperature of Co-Cr-Mo alloy was above $1,200^{\circ}C$ and pore size of casting specimen were finer than sintered specimen, but hardness were similar.

CAD/CAM 전용 금속 합금과 주조용 합금의 세라믹 결합강도에 관한 연구 (A Study on the Metal-Ceramic Bond Strength of CAD/CAM Metal Disk Alloy and Casting Alloy)

  • 정효경;곽동주
    • 대한치과기공학회지
    • /
    • 제35권2호
    • /
    • pp.89-95
    • /
    • 2013
  • Purpose: The purpose of this study was to evaluate bond strength of Metal Disk alloy and casting alloy. Methods: Metal specimens were divided into 4 groups for each alloy. Three point flexural test were used to measure the bond strength of CAD/CAM metal alloy and casting alloy. Statistical analysis was done using the Statistical Package for Social Sciences version 19.0 for Windows. As for the analysis methods, the study used Kruskal-Wallis test. Results: The average bonding strengths of Group 1 to porcelain was $36.7{\pm}9.90$ MPa, Group 2 to porcelain was $37.68{\pm}4.51$ MPa, Group 3 to porcelain was $36.43{\pm}6.57$ MPa, Group 4 to porcelain was $42.88{\pm}6.81$ MPa, Each group was not significantly different. Conclusion: Bond strength of Casting alloy is equal to or higher than bond strength of CAD/CAM Metal Disk alloy. Alloy clinical bond strength is 25 MPa, So CAD/CAM Metal Disk alloy can be used as dental material.

치과용 합금 주조 시 주조링의 계류시간에 따른 보철물의 변연 적합도 실험에 관한 연구 (An Experimental Study on Margin Consistency of Prosthesis According to the Continued Time of Casting-Ring in the course of the Casting of Dental Alloy)

  • 황성식;이상혁
    • 대한치과기공학회지
    • /
    • 제23권2호
    • /
    • pp.179-188
    • /
    • 2002
  • With regard to the manufacture of dental prosthesis, all the dental mechanism is of vital significance at the aspect of activating its function by fixing the prosthesis to Patient's oral cavity. However, if there we will take our immediate action without the discretion about its process none the less for the importance of dental mechanism, then we might have a serious problem. Accordingly, there need to pay attention to the dilatability makes up for the shrinkage state occurring by the feature of metal materials and manufacturing process which appeared in the process of dental mechanism, which eventually is expected to playa very important role in casting a dental prosthesis appropriate to one's oral tissue. This study was designed to take into account of the effects on margin consistency of prosthesis according to the continued time of casting-ring in the course of the casting of dental alloy. For this, the researcher made an experiment on the casting of dental alloy, its dilatability, and the change of phase. The results of this study were as follows: First, the researcher could see that the sample which was cast under the condition of $650^{\circ}C/20$ Minutes(the continued time) was far superior to others at the aspect of margin consistency. Second, according to the measurement of expansion coefficient by Dilatometer, the researcher perceived the fact that the expansion-coefficient showed a maximum of $37.1{\mu}m$ considering the sample's length which was cast with ordinary temperature under the condition of $650^{\circ}C/20$ Minutes. Third, from the result of X-ray diffraction under the condition of $650^{\circ}C/20$ Minutes(the continued time), the researcher could find that there's no difference between the change of phase and its intensity. As mentioned above, the researcher could ascertain the fact that its contraction don't give rise to the change of phase.

  • PDF

치과주조용 비귀금속 합금의 금속 용출 수준 (Concentration of elemental ions released from non-precious dental casting alloys)

  • 사공준;박수철
    • 대한치과기공학회지
    • /
    • 제35권1호
    • /
    • pp.1-17
    • /
    • 2013
  • Purpose: This study was to assess the extents of the release of metals from the non-precious alloys used for dental casting by measuring the differences in the extents of the release of metals by types of alloys, pH level and elapsed time. Methods: Uniform-sized specimens(10 each) were prepared according to the Medical Device Standard of the Korea Food and Drug Administration(2010) and International Standard Organization(ISO22674, 2006), using four types of alloys(one type of Ni-Cr and one type of Co-Cr used for fixed prosthesis, and one type of Ni-Cr and one type of Co-Cr used for removable prosthesis). A total of 12 metal-release tests were performed at one-day, three-day, and two-week intervals, for up to 20 weeks. The metal ions were quantified using an Inductively Coupled Plasma-Atomic Emission Spectrometer. Results: The results showed that the extent of corrosion was higher in the ascending order of Jdium-$100^{(R)}$, Bellabond-$Plus^{(R)}$, Starloy-$C^{(R)}$, and Biosil-$F^{(R)}$. The lower the pH and the longer the elapsed time were, the greater the increase in metal corrosion. At pH 2.4, the release of Ni from Jdium-$100^{(R)}$, a Ni-Cr alloy, was up to 15 times greater than the release of Co from the Co-Cr alloy from two weeks over time, indicating that the Ni-Cr alloy is more susceptible to corrosion than the Co-Cr alloy. Conclusion: It is recommended that Co-Cr alloy, which is highly resistant to corrosion, be used for making dental prosthesis with a non-precious alloy for dental casting, and that non-precious alloy prosthesis be designed in such a way as to minimize the area of its oral exposure. For patients with non-precious alloy prostheses, a test of the presence or absence of periodontal tissue inflammation or allergic reaction around the prosthesis should be performed via regular examination, and education on the good management of the prosthesis is needed.

국부의치 제작에 사용되는 Chrome Cobalt Alloy 주조 시 매몰방법과 주조방향이 주조성에 미치는 영향에 관한 연구 (A Study on the Castability of Investing Method and Casting Direction of Chrome-Cobalt Alloy Widely Used in Production of Patial Denture Framework)

  • 정경풍;최운재
    • 대한치과기공학회지
    • /
    • 제21권1호
    • /
    • pp.77-85
    • /
    • 1999
  • When producing partial denture using a Chrome-cobalt alloy being used universally, 45 pattern of them to compare casting characters according to 5 burying methods(special ring method, plastic ring method, general metal ring method) and 5 casting directions(straight, upper, lower, left and right directions) were compared and evaluated. The results were as follows : 1. The comparison of casting characters in accordance with burying type shows that the special ring method to install blind air vent using utility wax was the highest rate of 76.9%, followed by 69.1% of the plastic ring to cast without ring and 61.1% of the metal ring method being used universally respectively. Namely the special ring method was best. The significant level was P<0.05 statistically. 2. The comparison of casting character in accordance with casting directions shows that the straight casting was the highest of 77.9%, and followed by right casting of 74.2%, left casting of 66.7%, upper casting of 63.5%, and lower casting of 62.9% respectively, Namely the straight casting was best.

  • PDF

관교의치 및 금속 도재 보철물용 Ni-Cr 합금과 Ag-Pd 합금의 재사용에 따른 주조 재현성의 변화 (Castability of Some Repeatedly Used Ni-Cr Alloys and Ag-Pd Alloys for Crown and Bridge and Metal-Ceramic Restorations)

  • 김웅철
    • 대한치과기공학회지
    • /
    • 제8권1호
    • /
    • pp.37-43
    • /
    • 1986
  • The purpose of this study is to evalute the effects of melting and casting procedures on the castability of some N-Cr and Ag-Pd alloys. One Ag-Pd alloy and two Ni-Cr alloys were chosen for study, and the first casting group of these alloys were used as the control, and with which the castability of the first recase group and the mixture group of the first recast and as much amount of the first casting alloy was compared. The results of this study were as follows: 1. The castability of the first recast alloys veried significantly depending upon the presence or abscence of the first casting alloy and the kind of alloys. 2. When the first recast alloy was mixed with as much amount of the first casting alloy, there was no significant difference in castabilityh between the first recast group and the first casting group. 3. When the first recast alloy was used alone, the castability veried significantly depending upon the kind of alloys, i.e., the castability of Rexillium III and Palliag M was decreased significantly when compared with that of the first casting groups, while that of C & B Alloy was not.

  • PDF

치과용 주조 합금의 방전가공에 따른 표면 성분 변화 (Elemental alteration of the surface of dental casting alloys induced by electro discharge machining)

  • 장용철;이명곤
    • 대한치과기공학회지
    • /
    • 제31권1호
    • /
    • pp.55-61
    • /
    • 2009
  • Passive fitting of meso-structure and super-structures is a predominant requirement for the longevity and clinical success of osseointegrated dental implants. However, precision and passive fitting has been unpredictable with conventional methods of casting as well as for corrective techniques. Alternative to conventional techniques, electro discharge machining(EDM) is an advanced method introduced to dental technology to improve the passive fitting of implant prosthesis. In this technique material is removed by melting and vaporization in electric sparks. Regarding the efficacy of EDM, the application of this technique induces severe surface morphological and elemental alterations due to the high temperatures developed during machining, which vary between $10,000{\sim}20,000^{\circ}C$. The aim of this study was to investigate the morphological and elemental alterations induced by EDM process of casting dental gold alloy and non-precious alloy used for the production of implant-supported prosthesis. A conventional clinical dental casting alloys were used for experimental specimens patterns, which were divided in three groups, high fineness gold alloy(Au 75%, HG group), low fineness gold alloy(Au 55%, LG group) and nonprecious metal alloy(Ni-Cr, NP group). The UCLA type plastic abutment patterns were invested with conventional investment material and were cast in a centrifugal casting machine. Castings were sandblasted with $50{\mu}m\;Al_2O_3$. One casting specimen of each group was polished by conventional finishing(HGCON, LGCON, NPCON) and one specimen of each group was subjected to EDM in a system using Cu electrodes, kerosene as dielectric fluid in 10 min for gold alloy and 20 min for Ni-Cr alloy(HGEDM. LGEDM, NOEDM). The surface morphology of all specimens was studied under an energy dispersive X-ray spectrometer (EDS). The quantitative results from EDS analysis are presented on the HGEDM and LGEDM specimens a significant increase in C and Cu concentrations was found after EDM finishing. The different result was documented for C on the NPEDM with a significant uptake of O after EDM finishing, whereas Al, Si showed a significant decrease in their concentrations. EDS analysis showed a serious uptake of C and Cu after the EDM procedure in the alloys studied. The C uptake after the EDM process is a common finding and it is attributed to the decomposition of the dielectric fluid in the plasma column, probably due to the development of extremely high temperatures. The Cu uptake is readily explained from the decomposition of Cu electrodes, something which is also a common finding after the EDM procedure. However, all the aforementioned mechanisms require further research. The clinical implication of these findings is related with the biological and corrosion resistance of surfaces prepared by the EDM process.

  • PDF