• 제목/요약/키워드: Dental Engineering

검색결과 1,057건 처리시간 0.026초

Evaluation of different approaches for using a laser scanner in digitization of dental impressions

  • Lee, Wan-Sun;Kim, Woong-Chul;Kim, Hae-Young;Kim, Wook-Tae;Kim, Ji-Hwan
    • The Journal of Advanced Prosthodontics
    • /
    • 제6권1호
    • /
    • pp.22-29
    • /
    • 2014
  • PURPOSE. This study aimed to investigate the potential clinical application of digitized silicone rubber impressions by comparing the accuracy of zirconia 3-unit fixed partial dentures (FPDs) fabricated from 2 types of data (working model and impression) obtained from a laser scanner. MATERIALS AND METHODS. Ten working models and impressions were prepared with epoxy resin and vinyl polysiloxane, respectively. Based on the data obtained from the laser scanner (D-700; 3Shape A/S, Copenhagen, Denmark), a total of 20 zirconia frameworks were prepared using a dental CAD/CAM system (DentalDesigner; 3shape A/S, Copenhagen, Denmark / Ener-mill, Dentaim, Seoul, Korea). The silicone replicas were sectioned into four pieces to evaluate the framework fit. The replicas were imaged using a digital microscope, and the fit of the reference points (P1, P2, P3, P4, P5, P6, and P7) were measured using the program in the device. Measured discrepancies were divided into 5 categories of gaps (MG, CG, AWG, AOTG, OG). Data were analyzed with Student's t-test ($\alpha$=0.05), repeated measures ANOVA and two-way ANOVA (${\alpha}=0.05$). RESULTS. The mean gap of the zirconia framework prepared from the working models presented a narrower discrepancy than the frameworks fabricated from the impression bodies. The mean of the total gap in premolars (P=.003) and molars (P=.002) exhibited a statistical difference between two groups. CONCLUSION. The mean gap dimensions of each category showed statistically significant difference. Nonetheless, the digitized impression bodies obtained with a laser scanner were applicable to clinical settings, considering the clinically acceptable marginal fit ($120{\mu}m$).

The bactericidal effect of an atmospheric-pressure plasma jet on Porphyromonas gingivalis biofilms on sandblasted and acid-etched titanium discs

  • Lee, Ji-Yoon;Kim, Kyoung-Hwa;Park, Shin-Young;Yoon, Sung-Young;Kim, Gon-Ho;Lee, Yong-Moo;Rhyu, In-Chul;Seol, Yang-Jo
    • Journal of Periodontal and Implant Science
    • /
    • 제49권5호
    • /
    • pp.319-329
    • /
    • 2019
  • Purpose: Direct application of atmospheric-pressure plasma jets (APPJs) has been established as an effective method of microbial decontamination. This study aimed to investigate the bactericidal effect of direct application of an APPJ using helium gas (He-APPJ) on Porphyromonas gingivalis biofilms on sandblasted and acid-etched (SLA) titanium discs. Methods: On the SLA discs covered by P. gingivalis biofilms, an APPJ with helium (He) as a discharge gas was applied at 3 different time intervals (0, 3, and 5 minutes). To evaluate the effect of the plasma itself, the He gas-only group was used as the control group. The bactericidal effect of the He-APPJ was determined by the number of colony-forming units. Bacterial viability was observed by confocal laser scanning microscopy (CLSM), and bacterial morphology was examined by scanning electron microscopy (SEM). Results: As the plasma treatment time increased, the amount of P. gingivalis decreased, and the difference was statistically significant. In the SEM images, compared to the control group, the bacterial biofilm structure on SLA discs treated by the He-APPJ for more than 3 minutes was destroyed. In addition, the CLSM images showed consistent results. Even in sites distant from the area of direct He-APPJ exposure, decontamination effects were observed in both SEM and CLSM images. Conclusions: He-APPJ application was effective in removing P. gingivalis biofilm on SLA titanium discs in an in vitro experiment.

레진 기질에 포함된 희석제들이 치과용 복합 재료의 특성 변화에 미치는 영향 (Effects of Various Diluents Included in the Resin Matrices on the Characteristics of the Dental Composites)

  • 유선화;김창근
    • 폴리머
    • /
    • 제33권2호
    • /
    • pp.153-157
    • /
    • 2009
  • 치과용 복합 재료의 레진 기질은 주로 2,2-bis[4-(2-hydroxy-3-methacryloyloxy propoxy) phenyl] propane(Bis-GMA)와 이의 점도 감소를 위한 희석제인 triethylene glycol dimethacrylate (TEGDMA)로 구성되어 있다. TEGDMA는 복합 재료의 중합 수축률과 흡수율을 증가시켜 치과용 복합 재료의 사용에 제약 요소로 작용하고 있다. 본 연구에서는 희석제 첨가량을 감소시켜 희석제 첨가에 따른 문제점을 해결하기 위해 diethylene glycol dimethacrylate(DEGDMA)와 ethylene glycol dimethacrylate(EGDMA)를 대체 희석제로 검토하였다. 이들 희석제를 이용하여 치과용 복합 재료를 제조해 특성 변화를 관찰한 결과 기존 소재에 비해 중합 수축를 감소와 기계적 물성의 증가가 관찰되었다. 특히 DEGDMA 혹은 EGDMA를 사용한 경우 평형 흡수율이 감소되어 흡수에 따른 물성 저하가 기존 재료에 비해 감소하였다.

지르코니아 표면에칭처리와 저온열화현상이 지르코니아와 전장도재의 결합강도에 미치는 영향 (Effects on Bond Strength between Zirconia and Porcelain according to Etching Treatment and Low Temperature Degradation)

  • 박진영;김재홍;김웅철;김지환;김혜영
    • 치위생과학회지
    • /
    • 제14권2호
    • /
    • pp.140-149
    • /
    • 2014
  • 본 연구에서는 지르코니아 에칭에 의한 표면변화가 지르코니아 코어와 도재 사이의 결합강도에 미치는 영향을 조사하기 위해 전단결합강도 실시하였고, 표면의 변화를 관찰하기 위한 SEM 측정, 에칭처리에 따른 지르코니아의 성분변화를 알아보기 위해 EDS 분석을 실시하였다. 그리고 구강상태에서 15~20년의 저온열화현상을 재현하기 위해 저온 열화 처리를 시행하여 전단결합강도 평가를 실시하여 다음과 같은 결과가 도출되었다. 1. 에칭처리를 시행하지 않은 시편과 에칭처리를 시행한 시편의 전단결합강도를 비교할 경우 에칭한 시편의 전단결합강도가 큰 것을 알 수 있다. 이는 에칭용액이 지르코니아코어 표면에 interlocking을 형성하여 기계적인 결합을 높여 주었을 것이라고 생각된다. 2. 전단결합강도의 결과(EZ>AEZ>NEZ>ANEZ)를 보았을 때 통계적으로는 유의한 차이를 보였으며, 저온열화처리를 하지 않고 에칭처리를 한 EZ군이 전단결합강도가 가장 큰 것을 알 수 있었다. 또한 파절 양상에서도 EZ군에서만 응집파절을 보여 가장 결합강도가 높다는 결과를 도출할 수 있다. 결론적으로 저온열화처리 여부에 관계없이 표면에칭처리를 한 시편의 전단결합강도가 큰 것으로 나타나 지르코니아 표면의 에칭처리로 인한 interlocking의 형성이 기계적인 결합을 향상시키는 요인이 되었다고 생각된다.

치과 보철물에 사용되는 지르코니아 코어의 전단결합강도에 관한 연구 (Study about shear bond strength of zirconia core used in dental prosthesis)

  • 심지영;김재홍;김웅철;김혜영;김지환
    • 대한치과기공학회지
    • /
    • 제33권4호
    • /
    • pp.299-306
    • /
    • 2011
  • Purpose: This study aimed to investigate the shear bond strength by manufacturing the veneering porcelain on the IPS e.max $ZirCAD^{(R)}$ zirconia core, using the layering technique and heat-pressing technique, and to evaluate the clinical stability by comparing to the conventional metal ceramic system. Methods: The Schmitz-Schulmeyer test method was used to evaluate the core-veneer shear bond strength of zirconia core ceramic(IPS e.max $ZirCAD^{(R)}$) and their manufacture recommended two veneering ceramic systems(IPS e.max $ceram^{(R)}$, IPS e. max $ZirPress^{(R)}$). A metal ceramic system(Bellabond $plus^{(R)}$, VITA $VM13^{(R)}$) was used as a control group for the two all ceramic system test groups. The maximum loading and shear bond strength was measured. The average shear strength(MPa) was analyzed with the one-way ANOVA and the Tukey's test(${\alpha}$=.05). The fracture specimens were examined using Microscope to determine the failure pattern. Results: The mean shear bond strengths(SD) in MPa were MBSB control 43.62(2.13); ZBSB 18.65(1.76); ZPSB 18.89(1.54). The shear strengths of the zirconia cores were not significantly different(P>.05). Microscope examination showed that zirconia specimens presented mixed failure, and base metal alloy specimens showed adhesive failure. Conclusion: There was no siginificant different between the layering technique and the heat pressing technique in the veneering methods on the zirconia cores. None of the zirconia core and veneering ceramics could attain the high bond strength values of the metal ceramic combination.

2종류의 버와 3종류의 버를 이용해 제작된 크라운 보철물의 정밀도 평가 (Precision evaluation of crown prosthesis manufactured by two bur and three bur)

  • 김총명;전진훈;이재준;김지환;김웅철
    • 대한치과기공학회지
    • /
    • 제38권2호
    • /
    • pp.57-62
    • /
    • 2016
  • Purpose: The purpose of this study was to assess precision of crown prostheses that were fabricated by using 2 kinds of bur or 3 kinds of bur. Methods: The crowns were fabricated by using the first molar of the right maxillary in this study. The abutments that were prepared were scanned by using a scanner and designed by using CAD software. Based on the crown design, NC data were created with CAM software. The created NC data were used while fabricating the crown prostheses by using 5-axis milling machine. Scanning was done for the internal and external surface of the completed crown prostheses and 3-dimensional measurement was conducted for precision assessment. Results: The $RMS{\pm}SD$ value for the external surface of the crown prostheses that was fabricated by using two burs and three burs were $28.5{\pm}4.1{\mu}m$ and $19.1{\pm}2.8{\mu}m$, respectively; and the value for two burs were bigger than that for three burs with statistical significance (p<0.001). The $RMS{\pm}SD$ value for the internal surface of the crown prostheses that was fabricated by using two burs and three burs were $14.9{\pm}1.9{\mu}m$ and $13.3{\pm}2.5{\mu}m$, respectively; and the value for two burs were bigger than that for three burs but with no statistical significance. Conclusion: Based on this study, the prostheses that were fabricated by using 3 bur presented better stability compared to those that were fabricated by using 2 bur and statistically significant difference was found only in the external surface.

일반병원과 치과병원과의 방사선 관계종사자 피폭선량 비교분석 (A Comparative Analysis of Exposure Doses between the Radiation Workers in Dental and General Hospital)

  • 양남희;정운관;동경래;최은진;주용진;송하진
    • 방사선산업학회지
    • /
    • 제9권1호
    • /
    • pp.47-55
    • /
    • 2015
  • Research and investigation is required for the exposure dose of radiation workers to work in the dental hospital as increasing interest in exposure dose of the dental hospital recently accordingly, study aim to minimize radiation exposure by making a follow-up study of individual exposure doses of radiation workers, analyzing the status on individual radiation exposure management, prediction the radiation disability risk levels by radiation, and alerting the workers to the danger of radiation exposure. Especially given the changes in the dental hospital radiation safety awareness conducted the study in order to minimize radiation exposure. This study performed analyses by a comparison between general and dental hospital, comparing each occupation, with the 116,220 exposure dose data by quarter and year of 5,811 subjects at general and dental hospital across South Korea from January 1, 2008 through December 31, 2012. The following are the results obtained by analyzing average values year and quarter. In term of hospital, average doses were significantly higer in general hospitals than detal ones. In terms of job, average doses were higher in radiological technologists the other workes. Especially, they showed statistically significant differences between radiological technologists than dentists. The above-mentioned results indicate that radiation workers were exposed to radiation for the past 5 years to the extent not exceeding the dose limit (maximum $50mSv\;y^{-1}$). The limitation of this study is that radiation workers before 2008 were excluded from the study. Objective evaluation standards did not apply to the work circumstance or condition of each hospital. Therefore, it is deemed necessary to work out analysis criteria that will be used as objective evaluation standard. It will be necessary to study radiation exposure in more precise ways on the basis of objective analysis standard in the furture. Should try to minimize the radiation individual dose of radiation workers.

직무기반 치과기공사 실기시험 시행 방안에 대한 제언 (Suggestions on the implementation plan for job-based dental technician practical exam)

  • 김재홍;김기백;김원수
    • 대한치과기공학회지
    • /
    • 제43권4호
    • /
    • pp.181-185
    • /
    • 2021
  • Purpose: This study aims to make suggestions for the implementation of the job-based dental technician practical exam. Methods: The duties of dental technicians and the recent trends in the dental technician field were defined and identified, respectively, to achieve the purpose of the current study. The practical test system of domestic and foreign national tests was comparatively analyzed to seek improvements. Additionally, the direction of the practical test to be taken in the future was investigated through a public hearing of domestic experts. Results: As a result of this study, the job site of dental technicians was recently found to be undergoing many changes, and it can be observed that related laws and the work site have already changed. Comparison of overseas test systems showed that Korea was limited to a rather small evaluation range; in general, the scope of the evaluation of the practical tests in foreign countries was widely conducted. In the results of the public hearing, opinions exist that the evaluation range of the practical test was expanded and that new subjects were needed, but the opinion on the existence of practical difficulties was mainly mentioned. Conclusion: The evaluation range of the current practical examination subjects should be expanded and the evaluation of digital dental engineering subjects should be added to proceed with the job-based practical examination. However, it seems that efforts should be made gradually through various efforts in the future due to practical difficulties.

익산시 거주 모친의 자녀에 대한 구강건강관리 행태 (Mother' Oral Health Management Behavior to their Children In Iksan)

  • 최미숙
    • 환경위생공학
    • /
    • 제21권2호
    • /
    • pp.36-46
    • /
    • 2006
  • The purpose if this study was to investigate mother' oral health management behavior to their children. Two hundreds sixty seven mothers with elementary school students were surveyed among the residents living of Iksan city, Korea. A questionnaire was constructed and administered to the samples. The research focused in the following items: the subjects' socio-demographic factors such as education level and employment and so on; their knowledge of plaque; the leading causes of caries, regular dental examinations; dental treatment; their interest in their children's dental health; the frequency of the subjects examining their children's teeth; non-cariogenic food preparation, etc. Being based in collected data, mothers' oral health management behavior to their children were analyzed according to maternal socio-demographic factor and result were following. There was a difference in the subjects knowledge of dental plaque in accordance with their employment or unemployment and family income. There was no difference in mother's oral health management behavior to their children according to parents' education level, the subjects' age and family income. Most of mother answered the main reason of dental caries was that their children did not toothbrush their teeth regularly and there was a difference in the understanding of the subjects in accordance with the education level of fathers and family income. The subjects had a low understanding of the effect of preventing caries with the help of fluoride. They didn't have enough understanding of water fluoridation. So it is necessary that active campaigns should be launched to enlighten people in relation to the ways of preventing dental caries with fluoride.

A Study on the Nasal Index of Malocclusion Patients Using Cone-Beam Computed Tomography 3D Program

  • Sung-Suk Bae;Hee-Jeung Jee;Yun-Ja Hwang;Ha-Rin Jang;Su-Jeong Kang;Jeong-Hyun Lee
    • 치위생과학회지
    • /
    • 제24권3호
    • /
    • pp.146-151
    • /
    • 2024
  • Background: Research is continuously being conducted on the relationship between the airway and malocclusion. The nose, as the upper part of the respiratory pathway, plays a critical role. While various international studies employ the Nasal Index classification for nasal morphology, domestic research remains scarce. This research investigates the proportions of nasal morphology in malocclusion patients utilizing a 3D software. Methods: The study evaluated 100 malocclusion patients in their 20s (40 Class I, 34 Class II, 26 Class III). Cone-beam computed tomography was used with the Mimics (ver. 22; Materialise) 3D program to model the skull and soft tissues of the patients in three views: coronal, sagittal, and frontal. Results: The results showed that in Class I, there were 5 leptorrhine (long and narrow) cases, 30 mesorrhine (moderate shape) cases, and 5 platyrrhine (broad and short) cases. In Class II, there were 3 leptorrhine, 25 mesorrhine, and 6 platyrrhine cases. In Class III, there were 2 leptorrhine, 21 mesorrhine, and 3 platyrrhine cases. Conclusion: The findings of this study indicate that there is no significant correlation between the size of the nose and malocclusion in patients. Additionally, additional research related to this study is expected to be necessary.