• 제목/요약/키워드: Dental Engineering

검색결과 1,057건 처리시간 0.028초

A retrospective study of the long-term survival of RESTORE® dental implants with resorbable blast media surface

  • Keun-Soo Ryoo;Pil-Jong Kim;Sungtae Kim;Young-Dan Cho;Young Ku
    • Journal of Periodontal and Implant Science
    • /
    • 제53권6호
    • /
    • pp.444-452
    • /
    • 2023
  • Purpose: The aim of this study was to retrospectively evaluate the survival and failure rates of RESTORE® implants over a follow-up period of 10-15 years at a university dental hospital and to investigate the factors affecting the survival rate of these dental implants. Methods: A total of 247 RESTORE® dental implants with a resorbable blast media (RBM) surface inserted in 86 patients between March 2006 and April 2011 at the Department of Periodontology of Seoul National University Dental Hospital were included. Patients with follow-up periods of less than 10 years were excluded, and data analysis was conducted based on dental records and radiographs. Results: Over a 10- to 15-year period, the cumulative survival rate of the implants was 92.5%. Seventeen implants (6.88%) were explanted due to implant fracture (n=10, 4.05%), peri-implantitis (n=6, 2.43%), and screw fracture (n=1, 0.4%). The results of univariate regression analysis using a Cox proportional hazards model demonstrated that implants placed in male patients (hazard ratio [HR], 4.542; 95% confidence interval [CI], 1.305-15.807; P=0.017) and implants that supported removable prostheses (HR, 15.498; 95% CI, 3.105-77.357; P=0.001) showed statistically significant associations with implant failure. Conclusions: Within the limitations of this retrospective study, the RESTORE® dental implant with an RBM surface has a favorable survival rate with stable clinical outcomes.

치과 임플란트용 골융합 측정기의 설계 및 평가 (Design and Evaluation of Osseointegration Analysis System for Dental Implant)

  • 이주희;김창일;백종후;조정호;전명표;정영훈;이영진;이정배;이승대
    • 한국전기전자재료학회논문지
    • /
    • 제24권3호
    • /
    • pp.188-193
    • /
    • 2011
  • The osseointegration of dental implant is influenced by many factors such as surface geometry, loading and the amount of bone. Thus, stability of the dental implant should be checked periodically. In order to test the stability of dental implant by using resonance frequency analysis, we designed a structure of transducers and fabricated a piezoelectric devices. Using finite element analysis, the thickness and length of piezoelectric device and transducers were tailorized and the optimized frequency of 10 kHz was obtained. The resonance frequency from simulation analysis and evaluation was estimated to be similar as 10 kHz. The osseointegration was further enhanced with increasing frequency from the evaluation result of the finite element analysis.

치과용 임플란트의 형상과 계면 응력의 상관관계 (The relation between shape and interfacial stress of dental implants)

  • 김한성;이상업;조남효;고재영;박상수;이훈;안세영;심준성;이철영;문홍석
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2002년도 춘계학술대회 논문집
    • /
    • pp.128-131
    • /
    • 2002
  • Several FE models were developed based on micro-CT images of a mandibular specimen. A new dental implant model was suggested from parameter study for the relation between shape and interfacial stress of dental implants. It is found that the proposed model is highly beneficial.

  • PDF

Antimicrobial surfaces for craniofacial implants: state of the art

  • Actis, Lisa;Gaviria, Laura;Guda, Teja;Ong, Joo L.
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • 제39권2호
    • /
    • pp.43-54
    • /
    • 2013
  • In an attempt to regain function and aesthetics in the craniofacial region, different biomaterials, including titanium, hydroxyapatite, biodegradable polymers and composites, have been widely used as a result of the loss of craniofacial bone. Although these materials presented favorable success rates, osseointegration and antibacterial properties are often hard to achieve. Although bone-implant interactions are highly dependent on the implant's surface characteristics, infections following traumatic craniofacial injuries are common. As such, poor osseointegration and infections are two of the many causes of implant failure. Further, as increasingly complex dental repairs are attempted, the likelihood of infection in these implants has also been on the rise. For these reasons, the treatment of craniofacial bone defects and dental repairs for long-term success remains a challenge. Various approaches to reduce the rate of infection and improve osseointegration have been investigated. Furthermore, recent and planned tissue engineering developments are aimed at improving the implants' physical and biological properties by improving their surfaces in order to develop craniofacial bone substitutes that will restore, maintain and improve tissue function. In this review, the commonly used biomaterials for craniofacial bone restoration and dental repair, as well as surface modification techniques, antibacterial surfaces and coatings are discussed.

치과용 복합레진의 기계적 성질과 AE특성 (MECHANICAL PROPERTIES AND ACOUSTIC EMISSION CHARACTERISTICS OF DENTAL COMPOSITE RESINS)

  • 김교한;박진훈
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1990년도 추계학술대회
    • /
    • pp.64-67
    • /
    • 1990
  • Bending strength, bending elastic modulus ,and fracture toughness of different types of dental composite resins were deter mined. The relationship between bending strength, fracture toughness and filler volume fraction of dental composite resin was understood. In Acoustic Emission(AE) behavior during fracture toughness test, characteristic generation patterns of each type were understood. The fracture toughness values, AE generation patterns, and the nature of fracture surface were analyzed to understand fracture behavior of dental composite resin.

  • PDF

The Effectiveness of a Proposed VR Model as a Method to Relieve Distress and Improve Communication during Pediatric Dental Treatment in 3-9 Year-Old Children

  • Aalqeel, Samia;Song, Eun-Jee
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국정보통신학회 2022년도 춘계학술대회
    • /
    • pp.577-578
    • /
    • 2022
  • This study addresses the effectiveness of a VR model that is designed to relieve distress and improve communication during pediatric dental treatment for 3-9 year-old young patients. This is due to the challenging nature of the dental treatment for both young patients and pediatric dentists. The proposed model is designed to alleviate the unpleasant experience a young patient might go through during the dental treatment through providing a VR content to be displayed in on a head-mounted device during the treatment session. In addition, the model is designed to help decrease the frequent movement of the young patient during the dental treatment session by directing the patient's head to the immersive VR content. Furthermore, the model could solve the communication difficulties that might occur between pediatric dentists and young patients during the treatment session by showing live instructions related to adjusting body postures

  • PDF

의료기기에 대한 임상모니터링 기반의 지속적 품질개선: 치과용 임플란트의 사례 (Continuous Quality Improvement of Medical Equipments Based on Clinical Monitoring: A Case Study of Dental Implants)

  • 김명덕;엄태관;김영진
    • 품질경영학회지
    • /
    • 제36권2호
    • /
    • pp.59-66
    • /
    • 2008
  • Dental implant has recently become one of the most viable treatment options for regaining the oral function and dental aesthetics compared with conventional fixed or removable dentures. Dental implants vary in material, dimensions, geometries, surface properties, and interface geometries. It has been reported that there has been a proliferation of manufacturers who produce implants using various materials and surface treatments, and the dentist needs to select from over 2,000 different dental implants and abutments in a specific treatment situation. Unfortunately, however, no metrics have been specifically identified for the purpose of quality assessment and selection of an appropriate dental implant. This study aims to provide practical guidelines for quality assessment of dental implant based on clinical data. Like other medical devices and materials, the superiority related to specific characteristics of the dental implant needs to be verified through extensive clinical studies. The procedures of clinical monitoring for dental implants have been proposed along with a case study to exemplify the usefulness of clinical monitoring for the purpose of continuous quality improvement in medical industry.

디지털 X선 영상을 이용한 치아 와동 컴퓨터 보조 검출 시스템 연구 (A Study of Computer-aided Detection System for Dental Cavity on Digital X-ray Image)

  • 허창회;김민정;조현종
    • 전기학회논문지
    • /
    • 제65권8호
    • /
    • pp.1424-1429
    • /
    • 2016
  • Segmentation is one of the first steps in most diagnosis systems for characterization of dental caries in an early stage. The purpose of automatic dental cavity detection system is helping dentist to make more precise diagnosis. We proposed the semi-automatic method for the segmentation of dental caries on digital x-ray images. Based on a manually and roughly selected ROI (Region of Interest), it calculated the contour for the dental cavity. A snake algorithm which is one of active contour models repetitively refined the initial contour and self-examination and correction on the segmentation result. Seven phantom tooth from incisor to molar were made for the evaluation of the developed algorithm. They contained a different form of cavities and each phantom tooth has two dental cavities. From 14 dental cavities, twelve cavities were accurately detected including small cavities. And two cavities were segmented partly. It demonstrates the practical feasibility of the dental lesion detection using Computer-aided Detection (CADe).

치과기공사 국가시험 실기시험 제도 개선에 관한 연구 (A Study on Improvement of Dental Technicians practical examination system)

  • 남상용;정인성;이규선;김지환;유진호;이선경
    • 대한치과기공학회지
    • /
    • 제36권1호
    • /
    • pp.27-37
    • /
    • 2014
  • Purpose: The purpose of this study is to investigate the improvement measure of dental technicians practical examination system. Methods: The subjects in this study were 290 dental technicians who were self-written questionnaire. The results were analyzed by SPSS 16.0. The collected data was analyzed by frequency and chi-square test. Results: Dental technician practical exam feasibility of survey were largely negative views. Articulators work required in practical exam as a tool used (28.7%), electric wax carver (19.5%), heating clear (17.8%), handpiece (16.2%) had a response. Dental Technician positions in accordance with practical exam in comparison to satisfaction, the professor is satisfied, but the clinical dental technicians were generally dissatisfied (p<0.05). Conclusion: Based on the results of this study, Current is necessary to analyze the practical test. It also should be compared with foreign institutions. Long-term and short-term improvement examination system that can be applied to the improvement of the dental technician to draw practical test it is necessary to improve the system.

백색광과 청색 LED 방식의 광학스캐너로 채득된 디지털 모형의 비교분석 (Comparative analysis on digital models obtained by white light and blue LED optical scanners)

  • 최석순;김재홍;김지환
    • 대한치과기공학회지
    • /
    • 제36권1호
    • /
    • pp.17-23
    • /
    • 2014
  • Purpose: The purpose of this study was to analyze and compare the relative accuracy of digitized stone models of lower full arch, using two different scanning system. Methods: Replica stone models(N=20) were produced from lower arch acrylic model. Twenty digital models were made with the white light and blue LED($Medit^{(R)}$, Korea) scanner. Two-dimensional distance between the landmarks were measured on the Delcam $CopyCAD^{(R)}$(Delcam plc, UK). Independent samples t-test was applied for comparison of the groups. All statistical analyses were performed using the SPSS software package(Statistical Package for Social Sciences for Windows, version 12.0). Results: The absolute disagreement between measurements made directly on the two different scanner-based dental digital models was 0.02~0.04mm, and was not statistically significant(P>0.05). Conclusion: The precision of the blue LED optical scanner was comparable with the digitization device, and relative accuracy was similar. However, there still is room for improvement and further standardization of dental CAD technologies.