Quantitative Analysis of Quadrupole Noise Sources upon Quick Opening The Throttle (쓰로틀밸브 급개방시 기류소음의 4극음원에 대한 정량적 해석)

  • Kim Jaeheon;Cheong Cheolung;Kim SungTae;Lee Soogab
    • Proceedings of the Acoustical Society of Korea Conference
    • /
    • spring
    • /
    • pp.469-474
    • /
    • 2002
  • In recent years, modularization of engine parts has increased the application of plastic products in air intake systems. Plastic intake manifolds provide many advantages including reduced weight, contracted cost, and lower intake air temperatures. These manifolds, however, have some weakness when compared with customary aluminium intake manifolds, in that they have low sound transmission loss because of their lower material density. This low transmission loss of plastic intake manifolds causes several problems related to flow noise, especially when the throttle is opened quickly. The physical processes, responsible for this flow noise, include turbulent fluid motion and relative motion of the throttle to the airflow. The former is generated by high-speed airflow in the splits between the throttle valve and the inner-surface of the throttle body and surge-tank, which can be categorized into the quadrupole source. The latter induces the unsteady force on the flow, which can be classified into the dipole source. In this paper, the mechanism of noise generation from the turbulence is only investigated as a preliminary study. Stochastic noise source synthesis method is adopted for the analysis of turbulence-induced, i.e. quadrupole noise by throttle at quick opening state. The method consists of three procedures. The first step corresponds to the preliminary time-averaged Navier-Stokes computation with a $k-\varepsilon$ turbulence model providing mean flow field characteristics. The second step is the synthesis of time-dependent turbulent velocity field associated with quadrupole noise sources. The final step is devoted to the determination of acoustic source terms associated with turbulent velocity. For the first step, we used market available analysis tools such as STAR-CD, the trade names of fluid analysis tools available on the market. The steady state flows at three open angle of throttle valve, i.e. 20, 35 and 60 degree, are numerically analyzed. Then, time-dependent turbulent velocity fields are produced by using the stochastic model and the flow analysis results. Using this turbulent velocity field, the turbulence-originated noise sources, i.e. the self-noise and shear-noise sources are synthesized. Based on these numerical results, it is found that the origin of the turbulent flow and noise might be attributed to the process of formulation and the interaction of two vortex lines formed in the downstream of the throttle valve. These vortex lines are produced by the non-uniform splits between the throttle valve and inner cylinder surface. Based on the analysis, we present the low-noise design of the inner geometry of throttle body.

  • PDF

Improvement of ALINEA Model Using Speed (속도를 이용한 ALINEA 모델 보완에 관한 연구)

  • Cho, Han-Seon;Lee, Jun;Lee, Ho-Won;Kim, Eun-Mi
    • Journal of Korean Society of Transportation
    • /
    • v.26 no.5
    • /
    • pp.73-80
    • /
    • 2008
  • ALINEA algorithm, which is one of the best on-ramp metering algorithms, was designed to control the traffic volume from on-ramp in order to maintain the optimal occupancy rate of the detectors installed downstream of the merge area. But, the reliability of occupancy rate estimated from the loop detectors, which are used most commonly in Korea, is relatively lower than other parameters such as speed and volume. Moreover, because occupancy rate depends on the length of loop detectors and site, lots of calibration work is required whenever they are installed in order to estimate the occupancy rate. Therefore, there exists room for improvement of ALINEA algorithm because only occupancy rate having some problems is considered as a control parameter in ALINEA algorithm. Practically it is difficult to measure or perceive the occupancy rate for traffic engineers and drivers. On the other hand, speed can be good alternative which can overcome the defect induced by using occupancy. In this study, occupancy based ALINEA algorithm is converted to speed based ALINEA assuming the linear relationship between density and speed.

High rate magnetron sputtering of thick Cr-based tribological coatings

  • Bin, Jin H.;Nam, Kyung H.;Boo, Jin H.;Han, Jeon G.
    • Journal of Surface Science and Engineering
    • /
    • v.34 no.5
    • /
    • pp.409-413
    • /
    • 2001
  • In this study, high rate deposition of thick CrNx films was carried out by crossed field unbalanced magnetron sputtering for the special application such as piston ring employed in automobile engine. For the high rate deposition and thick CrNx films formation with thickness of 30$\mu\textrm{m}$, high power density of $35W/cm^2$ in each target was induced and the multi-layer films of Cr/CrN and $\alpha$-Cr/CrN were synthesized by control of $N_2$ flow rate. The dynamic deposition rate of Cr and $\alpha$-CrN film was reached to 0.17$\mu\textrm{m}$/min and 0.12$\mu\textrm{m}$/rnin and the thick CrN$_{x}$. film of 30$\mu\textrm{m}$ could be obtained less than 5 hours. The maximum hardness was obtained above 2200 kg/mm$^2$ and adhesion strength was measured in about 70N, in case of multi-layers films. And the friction coefficient was measured by 0.4, which was similar to the value of CrN single-layer film.m.

  • PDF

Feasibility Study on Cold Water Pipe Diameter by Friction Loss and Energy Conversion on OTEC (해양온도차 발전을 위한 심층수 파이프 직경에 따른 에너지 손실량 검토)

  • Jung, Hoon;Heo, Gyunyoung
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2010.11a
    • /
    • pp.170-170
    • /
    • 2010
  • The energy conversion from the temperature difference between hot and cold source like ocean thermal energy conversion (OTEC), requires a long and large-diameter pipe (about 1000 to 10,000 meters long) to reach the deep water. The pipe diameter ranges from 2.8 meter for proposed early test systems, to 5 meter for large, commercial power generation systems. The pipe must be designed to resist collapsing pressures produced by water temperature and density differences, and the reduced pressure required to induce flow up the pipe. Other design considerations include the external-drag effect on the pipe due to ocean currents, and the wave-induced motions of the platform to which the pipe is attached. Various approaches to the pipe construction have been proposed, including aluminum, steel, concrete, and fiberglass. More recently, a flexible pipe construction involving the use of fiberglass reinforced plastic has been proposed. This report presents the results of a scaled fixed cold water pipe (CWP) model test program performed by EES(Engineering Equation Solver) to demonstrate the feasibility of this pipe approach.

  • PDF

Magnetic Saturation Effect of the Iron Core in Current Transformers Under Lightning Flow

  • Kim, Young Sun
    • Transactions on Electrical and Electronic Materials
    • /
    • v.18 no.2
    • /
    • pp.97-102
    • /
    • 2017
  • A current transformer (CT) is a type of sensor that consists of a combination of electric and magnetic circuits, and it measures large ac currents. When a large amount of current flows into the primary winding, the alternating magnetic flux in the iron core induces an electromotive force in the secondary winding. The characteristics of a CT are determined by the iron core design because the iron core is saturated above a certain magnetic flux density. In particular, when a large current, such as a current surge, is input into a CT, the iron core becomes saturated and the induced electromotive force in the secondary winding fluctuates severely. Under these conditions, the CT no longer functions as a sensor. In this study, the characteristics of the secondary winding were investigated using the time-difference finite element method when a current surge was provided as an input. The CT was modeled as a two-dimensional analysis object using constraints, and the saturation characteristics of the iron core were evaluated using the Newton-Rhapson method. The results of the calculation were compared with the experimental data. The results of this study will prove useful in the designs of the iron core and the windings of CTs.

3D Modeling of Turbid Density Flow Induced into Daecheong Reservoir With ELCOM-CAEDYM (ELCOM-CAEDYM을 이용한 대청댐 유입탁수의 3차원 모델링)

  • Chung, Se-Woong;Lee, Heung-Soo;Yoon, Sung-Wan
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2008.05a
    • /
    • pp.379-383
    • /
    • 2008
  • 본 연구의 목적은 3차원 수리 모델인 ELCOM(Estuary, Lake and Coastal Ocean Model)과 물질 전달모델인 CAEDYM(Computational Aquatic Ecosystem Dynamic Model)을 이용하여 성층화된 저수지로 밀도류 형태로 유입한 부유사의 이송과 확산 그리고 침강특성을 해석하는데 있다. ELCOM은 3차원 수리동력학 모델로써 시공간적인 유속과 수온변화를 예측하는데 사용되었으며, CAEDYM과 매 계산시간 마다 동적으로 연결(Dynamic coupling)되어 부유입자의 이송, 확산, 침강 과정을 모의하였다. 개발된 3차원 모델의 예측 성능은 2004년 홍수기 동안 대청호에서 실측한 자료를 사용하여 검증하였다. 모델의 모의변수는 입자크기별로 구분된 부유물질(SS) 그룹이며, 현장 실측자료인 탁도($C_T$)와 모델 변수인 SS간의 변환을 위해 저수지 지점 별로 측정한 SS-$C_T$ 상관관계를 사용함으로써 부유 입자의 크기분포의 공간적 변동 특성을 반영하였다. 모델은 탁수가 유입하는 환경에서 저수지 성층구조의 변화와 유입 탁수의 밀도류 거동특성, 유입한 부유사의 이송과 확산 그리고 침강특성을 비교적 잘 모의하였다. 저수지로 유입한 부유입자 중 입경이 $20{\mu}m$ 이상인 입자는 매우 빠른 속도로 저수지 바닥에 퇴적된 반면, $10{\mu}m$ 이하의 입자들은 중층에 오랜 시간 부유하며 장기탁수문제를 유발하는 원인이 되었다.

  • PDF

Corrosive Wear of Alloy 690 Tubes in Alkaline Water

  • Hong, Seung Mo;Jang, Changheui;Kim, In Sup
    • Corrosion Science and Technology
    • /
    • v.8 no.3
    • /
    • pp.126-131
    • /
    • 2009
  • The interaction between wear and corrosion can significantly increase total material losses in water chemistry environment. The corrosive wear tests of a PWR steam generator tube material (Alloy 690) against the anti vibration bar material (409 SS) were performed at room temperature. The tests were performed in alkaline water chemistry conditions. NaOH solution was selected for test condition to investigate the corrosive wear effect of steam generator tube material in alkaline pH condition without other factors. The flow induced vibration can caused tube damage and the corrosion can be occurred by water chemistry. The test results showed that, in the alkaline solution at pH 13.9, the corrosion current density was increased about ten times than that in the distilled water. And wear rate at pH 13.9 was increased about ten times from that at neutral condition. However, the wear rate was decreased with time. The decrease would be attributed to the change in roughness of specimen or sub-layer of the worn surface with time. From microstructure observation, severe abrasive shape and several wear debris were found. From those results, it could infer that the oxide film on Alloy 690 changed to easily breakable one in the alkaline water, and then abrasion with corrosion became the main wear mechanism.

Transient response of unit PEMFC with the visualization study of cathode flooding under different stoichiometries (당량비 조건에 따른 PEM 단위 연료전지의 과도 응답 특성 및 공기극 플러딩 연구)

  • Cho, Jun-Hyun;Kim, Han-Sang;Min, Kyoung-Doug
    • New & Renewable Energy
    • /
    • v.3 no.2 s.10
    • /
    • pp.24-30
    • /
    • 2007
  • The transient response of PEMFC (proton exchange membrane fuel cell) is important criteria in the application of PEM fuel cell to real automotive system. In this work, using a transparent unit PEM fuel cell, the transient response and cathode flooding during load change are investigated. The cell voltage is acquired according to the current density change($0.3Acm^2$ to $0.6A/cm^2$) under various stoichiometry conditions and different flooding intensities, Also the cathode gas channel images are obtained by CCD imaging system simultaneously. The different level of undershoots appeared at the moment of load changes under different cathode stoichiometries and flooding intensities. It takes about 1s that the product water comes up onto the flow channel so that oxygen supply is temporarily blocked which causes voltage loss in that "undershoot". The correlation of the dynamic behavior with stoichiometry and cathode flooding is induced from the results of these experiments.

  • PDF

Bi-directional Two Terminal Switching Device based on SiGe for Spin Transfer Torque (STT) MRAM

  • Yang, Hyung-Jun;Kil, Gyu-Hyun;Lee, Sung-Hyun;Song, Yun-Heub
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2012.02a
    • /
    • pp.385-385
    • /
    • 2012
  • A two terminal N+/P/N+ junction device to replace the conventional selective transistor was studied as a bilateral switching device for spin transfer torque (STT) MRAM based on 3D device simulation. An N+/P/N+ junction structure with $30{\times}30nm$ area requires bi-directional current flow enough to write a data by a drain induced barrier lowering (DIBL) under a reverse bias at N+/P (or P/N+ junction), and high current on/off ratio of 106. The SiGe materials are widely used in hetero-junction bipolar transistors, bipolar compensation metal-oxide semiconductors (BiCMOS) since the band gap of SiGe materials can be controlled by changing the fraction and the strain epilayers, and the drift mobility is increased with the increasing Ge content. In this work, N+/P/N+ SiGe material based junction provides that drive current is increased from 40 to $130{\mu}A$ by increased Ge content from 10~80%. When Ge content is about 20%, the drive current density of SiGe device substantially increased to 2~3 times better than Si-based junction device in case of 28 nm P length, which is sufficient current to operation of STT-MRAM.

  • PDF

Modeling of deposition and erosion of CRUD on fuel surfaces under sub-cooled nucleate boiling in PWR

  • Seungjin Seo;Nakkyu Chae;Samuel Park;Richard I. Foster;Sungyeol Choi
    • Nuclear Engineering and Technology
    • /
    • v.55 no.7
    • /
    • pp.2591-2603
    • /
    • 2023
  • Simulating the Corrosion-Related Unidentified Deposit (CRUD) on the surface of fuel assemblies is necessary to predict the axial offset anomaly and the localized corrosion induced by the CRUD during the operation of nuclear power plants. A new CRUD model was developed to predict the formation of the CRUD deposits, considering the deposition and erosion mechanisms. The heat transfer and capillary flow within the CRUD were also considered to evaluate the boiling amount within the CRUD layer. This model predicted a CRUD deposit thickness of 44 ㎛ during a one-cycle operation of the Seabrook nuclear power plant. The CRUD deposition tended to accelerate and decelerate during the simulation, by being related to boiling mechanism on the deposits surface. Additionally, during a three-cycle operation corresponding to the refueling period, the CRUD deposition was saturated at a thickness of 80 ㎛, which was in good agreement with the suggested thickness for CRUD buildupin pressurized water reactors. Surface boiling on the thin CRUD deposits enhanced the acceleration of the deposition, even when the wick boiling properties were not favorable for CRUD deposition. To ensure the certainty of the simulation results, sensitivity analyses were conducted for the porosity, chimney density, and the constants employed in the proposed model of the CRUD.