• Title/Summary/Keyword: Density evaluation

Search Result 1,940, Processing Time 0.035 seconds

Evaluation for Mechanical Properties of Compress Strength and Dry Density of Concrete at NPP (원전 시설용 콘크리트의 압축강도 및 건조밀도 특성 평가)

  • Lee, Young-Dae;Kim, Gyu-Yong;Shin, Kyoung-Su;Nam, Jeong-Soo;Lee, Tae-Gyu;Choe, Gyeong-Choel
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2011.11a
    • /
    • pp.53-54
    • /
    • 2011
  • The facilities producing the nuclear energy chosen for resolving the recent global energy problem have been increasingly constructed, and hence more frequent durability tests on radiation shielding concrete are required due to NPP(Nuclear Power Plant) life extension and increase of radioactive waste repositories. Bulk dry density is one of the critical factors ensuring the durability and performance of the radiation shielding concrete because the design of the radiation shielding reinforced concrete structures for NPPs is based on the bulk dry density of the concrete. Bulk density of unconsolidated shielding concrete can be calculated utilizing a test assuring to satisfy the bulk dry density, or existing credible data set. This study evaluated correlation between bulk density and bulk dry density of the concrete used for Korean NPPs (y=1.0913X-0.2458) and developed a correlation expression considering standard deviation of bulk dry density (y=1.0913X-0.3358).

  • PDF

Thickness Evaluation of Pipeline Using Density Profile on a Radiograph (방사선투과필름에서 Density Profile을 이용한 배관의 두께 평가)

  • Lee, Sung-Sik;Jang, Byoung-Gyu;Kim, Young-H.
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.22 no.5
    • /
    • pp.483-489
    • /
    • 2002
  • The computer simulation has been done for non-insulated and insulated pipes which are vacant or half filled with liquid. The simulation results showed that the density profile on the radiography is continuous and symmetrical around the center of pipe in the case of vacant pipe. On the other hand the density profiles are not symmetrical and depend on geometrical setting for radiography in the case of half filled pipes. Finally, experimental testing on a non-insulated carbon steel pipe with artificial notches of different depth is carried out using Ir-192 and industrial film. Comparing the measured density profile on the radiograph to the calculated one, it has been shown that it is possible to evaluate thickness variation by measuring density profile on a radiograph.

Correlation between Bone Mineral Density Measured by Dual-Energy X-Ray Absorptiometry and Hounsfield Units Measured by Diagnostic CT in Lumbar Spine

  • Lee, Sungjoon;Chung, Chun Kee;Oh, So Hee;Park, Sung Bae
    • Journal of Korean Neurosurgical Society
    • /
    • v.54 no.5
    • /
    • pp.384-389
    • /
    • 2013
  • Objective : Use of quantitative computed tomography (CT) to evaluate bone mineral density was suggested in the 1970s. Despite its reliability and accuracy, technical shortcomings restricted its usage, and dual-energy X-ray absorptiometry (DXA) became the gold standard evaluation method. Advances in CT technology have reduced its previous limitations, and CT evaluation of bone quality may now be applicable in clinical practice. The aim of this study was to determine if the Hounsfield unit (HU) values obtained from CT correlate with patient age and bone mineral density. Methods : A total of 128 female patients who underwent lumbar CT for back pain were enrolled in the study. Their mean age was 66.4 years. Among them, 70 patients also underwent DXA. The patients were stratified by decade of life, forming five age groups. Lumbar vertebrae L1-4 were analyzed. The HU value of each vertebra was determined by averaging three measurements of the vertebra's trabecular portion, as shown in consecutive axial CT images. The HU values were compared between age groups, and correlations of HU value with bone mineral density and T-scores were determined. Results : The HU values consistently decreased with increasing age with significant differences between age groups (p<0.001). There were significant positive correlations (p<0.001) of HU value with bone mineral density and T-score. Conclusion : The trabecular area HU value consistently decreases with age. Based on the strong positive correlation between HU value and bone mineral density, CT-based HU values might be useful in detecting bone mineral diseases, such as osteoporosis.

A Study on Post Occupancy Evaluation of Block Housing -Focused on The Block Housing in Eunpyeong New Town, in Korea - (가구형 집합주택의 거주후평가 연구 - 은평뉴타운을 중심으로 -)

  • Park, Joong-Hyun;Choo, Sun-Kyong;Kang, Boo-Seong
    • Proceeding of Spring/Autumn Annual Conference of KHA
    • /
    • 2009.04a
    • /
    • pp.73-77
    • /
    • 2009
  • The block housing type is coming to fore as a 'low-rise high-density housing type', which can resolve the all sorts of problem caused in Korea apartment housing complex and single-detached residental area in terms of livability, urbanity, and community. To analyze the characteristics of the block housing, the block housing in Eunpyeong New Town, in Korea was analyzed as a sample for post occupancy evaluation. The analysis show that the block housing is useful low-rise and high-density housing type, which ensures the livability as well as the urbanity and community. In details the analysis also shows the user satisfaction from the perspective of living and facility use within the block housing and individual unit.

  • PDF

Quick evaluation for cement powder of synthesize with the hydrometer density value and change temperature (Hydrometer의 밀도 값과 혼탁액 온도를 복합한 포틀랜드 시멘트의 분말도 신속 평가)

  • Lee, Jae-Jin;Han, Jun-Hui;Hyun, Seong-Yong;Kim, Yeong-Tae;Han, Min-Cheol;Han, Cheon-Goo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2018.05a
    • /
    • pp.87-88
    • /
    • 2018
  • The change in the degree of powder in cement is very important because it plays a major role in the reaction in the concrete. In this study, we intend to apply the principle of early estimation of concrete strength using the non-middling method previously conducted to the quality evaluation of cement powder. In other words, it is proposed to analyze the potential of Hydrometer density values and the data of temperature variation in the trust solution to propose a method of acceptance inspection. According to the experimental results, the quick evaluation of the cement distributorship will be possible if the resulting regression results are used : y = 161867.4 x1 + 117.953 x2 - 165437 (R = 0.9158).

  • PDF

Evaluation of Copper-Chromium-Arsenic Preservatives Fixation on Wood by Measuring the Density of Surface Electric Charge (표면전하밀도(表面電荷密度)를 이용(利用)한 동(銅)·크롬·비소계(砒素系) 방부방충제의 정착(定着)에 관(關)한 연구(硏究))

  • Kim, Yeong-Suk
    • Journal of the Korean Wood Science and Technology
    • /
    • v.18 no.1
    • /
    • pp.24-30
    • /
    • 1990
  • This study was attempted to propose a method evaluating fixation of active ingredients in Copper-Chromium-Arsenic preservatives treatment. Fixated amount of active ingredients on wood was obtained by measuring the density of surface electric charge based on $\varsigma$ potential. Data accumulated from density of surface electric charge showed that the fixated amount of preservatives on wood increased linearly as concentration of treating solution increaced, which indicatied quantitative reactions in fixation of preservatives.

  • PDF

A new symbol timing algorithm for high storage density HDD (고 저장밀도 HDD를 위한 새로운 심볼동기 알고리즘)

  • 김위묵;최형진
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.21 no.6
    • /
    • pp.1554-1566
    • /
    • 1996
  • In this paper, a new symbol timing algorithm for a magnetic recording system as HDD, is proposed. Above all, the Lorentzian channel model applied, the distortion and the attenuation problems of playback signals at high speed and storage density were considered. The structure and the operation of popular data detectors for HDD were understood, and the adopted symbol timing algorithm were profoundly analyzed. On the basis of these understanding and analysis, a new symbol timing algorithm for high density HDD was proposed, and the performance evaluation of this proposed algorithm was done.

  • PDF

A Compilation and Evaluation of Thermal and Mechanical Properties of Bentonite-based Buffer Materials for a High- level Waste Repository

  • Cho, Won-Jin;Lee, Jae-Owan;Kang, Chul-Hyung
    • Nuclear Engineering and Technology
    • /
    • v.34 no.1
    • /
    • pp.90-103
    • /
    • 2002
  • The thermal and mechanical properties of compacted bentonite and bentonite-sand mixture were collected from the literatures and compiled. The thermal conductivity of bentonite is found to increase almost linearly with increasing dry density and water content of the bentonite. The specific heat can also be expressed as a function of water ontent, and the coefficient of thermal expansion is almost independent on the dry density. The logarithm of unconfined compressive strength and Young’s modulus of elasticity increase linearly with increasing dry density, and in the case of constant dry density, it can be fitted to a second order polynomial of water content. Also the unconfined compressive strength and Young’s modulus of elasticity of the bentonite-sand mixture decreases with increasing sand content. The Poisson’s ratio remains constant at the dry density higher than 1.6 Mg/m$_3$, and the shear strength increases with increasing dry density.

Evaluation of fracture density distribution for the design of grouting works in fractured rocks (그라우팅 설계를 위한 절리밀도분포 산출법 개발)

  • 김중열;김유성
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2002.03a
    • /
    • pp.627-634
    • /
    • 2002
  • To facilitate a drilling plan for grouting in fractured rock, an algorithm of practical use associated with a new term “fracture density distribution”or“fracture tomogram”is developed. It is well known that Televiewer data(amplitude and traveltime image) provide detailed information about not only dip and dip direction of each fracture but also its aperture size estimated by an appropriate evaluation algorithm. A selected plane section of medium around a borehole or the cross section between two boreholes is discretized into a two dimensional grid of cells(rectangular elements). As each elongated(straight) fracture passes through the cells, the corresponding aperture size value is successively summed up in each cell, depending on the fracture length segment. In this, the fracture lines can be determined by intersecting of each fracture plane with the selected plane section. If the fracture line does not pass through a particular grid element, the segment length is set to zero. The final value(aperture size value of each cell) derived from all the detected fractures constitutes the fracture density distribution of the selected plane section, Field examples are illustrated, which will prove the benefit of the suggested algorithm for several kinds of grouting works.