• Title/Summary/Keyword: Delivery Volume

Search Result 294, Processing Time 0.029 seconds

A Study on the Application of VAV/BPFS(Variable-Air-Volume/Bypass Filtration System) for Indoor Air Environment (VAV/BPFS(Variable-Air-Volume/Bypass Filtration System) 의 실내환경 적응에 관한 연구)

  • 최성우
    • Journal of Environmental Science International
    • /
    • v.12 no.12
    • /
    • pp.1235-1243
    • /
    • 2003
  • Under controlled conditions in an environmental chamber, 24 experiments were performed to compare the ability of a Variable-Air-Volume/Bypass Filtration System(VAV/BPFS) to remove indoor pollutants and to conserve energy with the ability of conventional Variable Air Volume(VAV) system. The specific conclusions of this paper were; first, the VAV/BPFS was more efficient than the VAV system in removing particulate matter, TVOC, and target VOCs. The total effective removal rate of PM for the VAV/BPFS was two times as high as that of the VAV system. The total effective removal rate of TVOC for the VAV/BPFS was 20 percent higher than that of the VAV system. Also each target VOC concentration was reduced by using the VAV/BPFS. Second, clean air delivery rate was increased by using VAV/BPFS due to additional filtration rate. Otherwise, the VAV/BPFS decreased outdoor supply air rate above 25 percent relative to the rate of VAV system. Third, total energy consumption by the VAV/BPFS was lower than that of the VAV system during the period with indoor thermal load, occupied time. The energy saving of the VAV/BPFS ranged from 11 to 16 percent. The VAV/BPFS improves indoor air quality more efficiently than the VAV system, and it reduced energy consumption. Retrofitting the VAV system with the VAV/BPFS was easy The use of VAV/BPFS is, therefore, recommended far buildings with VAV system as well as for buildings at designing stage.

Comparison of the Therapeutic Efficacy and Technical Outcomes between Conventional Fixed Electrodes and Adjustable Electrodes in the Radiofrequency Ablation of Benign Thyroid Nodules

  • Jae Ho Shin;Minkook Seo;Min Kyoung Lee;So Lyung Jung
    • Korean Journal of Radiology
    • /
    • v.25 no.2
    • /
    • pp.199-209
    • /
    • 2024
  • Objective: This study aimed to compare therapeutic efficacy and technical outcomes between adjustable electrode (AE) and conventional fixed electrode (FE) for radiofrequency ablation (RFA) of benign thyroid nodules. Materials and Methods: Between 2013 and 2021, RFA was performed on histologically proven benign thyroid nodules. For the AE method, AE length ≥ 1 cm with higher power and < 1 cm with lower power were utilized for ablating feeding vessels and nodules, especially those near anatomical structures, respectively. The therapeutic efficacy (volume reduction rate [VRR], complication rate, and regrowth rate) and technical outcomes (total energy delivery, ablated volume/energy, RFA time, and ablated volume/time) of FE and AE were compared. Continuous parameters were compared using a two-sample t-test or Mann-Whitney U test, and categorical parameters were compared using a chi-squared test or Fisher's exact test. Results: A total of 182 nodules (FE: 92 vs. AE: 90) in 173 patients (mean age ± standard deviation, 47.0 ± 14.7 years; female, 90.8% [157/173]; median follow-up, 726 days [interquartile range, 441-1075 days]) were analyzed. The therapeutic efficacy was comparable, whereas technical outcomes were more favorable for AE. Both electrodes demonstrated comparable overall median VRR (FE: 92.4% vs. AE: 84.9%, P = 0.240) without immediate major complications. Overall regrowth rates were comparable between the two groups (FE: 2.2% [2/90] vs. AE: 1.1% [1/90], P > 0.99). AE demonstrated a shorter median RFA time (FE: 811 vs. AE: 627 seconds, P = 0.009). Both delivered comparable median energy (FE: 42.8 vs. AE: 29.2 kJ, P = 0.069), but AE demonstrated higher median ablated volume/energy and median ablated volume/time (FE: 0.2 vs. AE: 0.3 cc/kJ, P < 0.001; and FE: 0.7 vs. AE: 1.0 cc/min, P < 0.001, respectively). Conclusion: Therapeutic efficacy between FE and AE was comparable. AE demonstrated better technical outcomes than FE in terms of RFA time, ablated volume/energy, and ablated volume/time.

A Method for Estimating the Lung Clinical Target Volume DVH from IMRT with and without Respiratory Gating

  • J. H. Kung;P. Zygmanski;Park, N.;G. T. Y. Chen
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2002.09a
    • /
    • pp.53-60
    • /
    • 2002
  • Motion of lung tumors from respiration has been reported in the literature to be as large as of 1-2 cm. This motion requires an additional margin between the Clinical Target Volume (CTV) and the Planning Target Volume (PTV). While such a margin is necessary, it may not be sufficient to ensure proper delivery of Intensity Modulated Radiotherapy (IMRT) to the CTV during the simultaneous movement of the DMLC. Gated treatment has been proposed to improve normal tissues sparing as well as to ensure accurate dose coverage of the tumor volume. The following questions have not been addressed in the literature: a) what is the dose error to a target volume without gated IMRT treatment\ulcorner b) what is an acceptable gating window for such treatment. In this study, we address these questions by proposing a novel technique for calculating the 3D dose error that would result if a lung IMRT plan were delivered without gating. The method is also generalized for gated treatment with an arbitrary triggering window. IMRT plans for three patients with lung tumor were studied. The treatment plans were generated with HELIOS for delivery with 6 MV on a CL2100 Varian linear accelerator with a 26 pair MLC. A CTV to PTV margin of 1 cm was used. An IMRT planning system searches for an optimized fluence map ${\Phi}$ (x,y) for each port, which is then converted into a dynamic MLC file (DMLC). The DMLC file contains information about MLC subfield shapes and the fractional Monitor Units (MUs) to be delivered for each subfield. With a lung tumor, a CTV that executes a quasi periodic motion z(t) does not receive ${\Phi}$ (x,y), but rather an Effective Incident Fluence EIF(x,y). We numerically evaluate the EIF(x,y) from a given DMLC file by a coordinate transformation to the Target's Eye View (TEV). In the TEV coordinate system, the CTV itself is stationary, and the MLC is seen to execute a motion -z(t) that is superimposed on the DMLC motion. The resulting EIF(x,y)is inputted back into the dose calculation engine to estimate the 3D dose to a moving CTV. In this study, we model respiratory motion as a sinusoidal function with an amplitude of 10 mm in the superior-inferior direction, a period of 5 seconds, and an initial phase of zero.

  • PDF

Verification of Gated Radiation Therapy: Dosimetric Impact of Residual Motion (여닫이형 방사선 치료의 검증: 잔여 움직임의 선량적 영향)

  • Yeo, Inhwan;Jung, Jae Won
    • Progress in Medical Physics
    • /
    • v.25 no.3
    • /
    • pp.128-138
    • /
    • 2014
  • In gated radiation therapy (gRT), due to residual motion, beam delivery is intended to irradiate not only the true extent of disease, but also neighboring normal tissues. It is desired that the delivery covers the true extent (i.e. clinical target volume or CTV) as a minimum, although target moves under dose delivery. The objectives of our study are to validate if the intended dose is surely delivered to the true target in gRT and to quantitatively understand the trend of dose delivery on it and neighboring normal tissues when gating window (GW), motion amplitude (MA), and CTV size changes. To fulfill the objectives, experimental and computational studies have been designed and performed. A custom-made phantom with rectangle- and pyramid-shaped targets (CTVs) on a moving platform was scanned for four-dimensional imaging. Various GWs were selected and image integration was performed to generate targets (internal target volume or ITV) for planning that included the CTVs and internal margins (IM). The planning was done conventionally for the rectangle target and IMRT optimization was done for the pyramid target. Dose evaluation was then performed on a diode array aligned perpendicularly to the gated beams through measurements and computational modeling of dose delivery under motion. This study has quantitatively demonstrated and analytically interpreted the impact of residual motion including penumbral broadening for both targets, perturbed but secured dose coverage on the CTV, and significant doses delivered in the neighboring normal tissues. Dose volume histogram analyses also demonstrated and interpreted the trend of dose coverage: for ITV, it increased as GW or MA decreased or CTV size increased; for IM, it increased as GW or MA decreased; for the neighboring normal tissue, opposite trend to that of IM was observed. This study has provided a clear understanding on the impact of the residual motion and proved that if breathing is reproducible gRT is secure despite discontinuous delivery and target motion. The procedures and computational model can be used for commissioning, routine quality assurance, and patient-specific validation of gRT. More work needs to be done for patient-specific dose reconstruction on CT images.

The Effects of Triamcinolone Acetonide by Iontiophoretic Transdermal Delivery on Inflammation Induced Rat (백서에서 유발된 염증에 대한 Triamcinolone Acetonide 이온도입 경피투과 효과)

  • Jung Dae-In;Kim Tae-Youl;Kim Kye-Yoep;Kim Myong-Hoon
    • The Journal of Korean Physical Therapy
    • /
    • v.15 no.2
    • /
    • pp.182-195
    • /
    • 2003
  • This study investigated the effects of triamcinolone acetonide by iontophoretic transdermal drug delivery on anti-inflammatory action into the rats and which had carrageenan-induced hyperalgesia and edema in the feet, trauma-induced tissue damage in the thigh. Each group was treated under the fellowing conditions. 1. Group I : Control group 2. Group II : Application of direct current 3. Group III : Application of 0.1$\%$ triamcinolone acetonide solution 4. Group IV : Iontophoresis of 0.1$\%$ triamcinolone acetonide solution The degree of anti-inflammation was evaluated by the paw withdrawal latency, the change in volume of foot the change of paw edema, histological change in rats. 1. In paw withdrawal latency, group IV showed the most significant therapeutic effect than the other groups at 0, 3, 6 and 9 hours(p < 0.001). 2. In paw edema experiment in the foot, group IV showed the most significant effect than group I at 0, 3, 6 and 9 hours. It meant that there was effective anti-inflammatory reaction in group I (p < 0.001). 3. In the light microscopic observation, group IV showed the most significant reduction of haemorrhage, hyperemia and infiltrative inflammation. From the results, the iontophoresis with triamcinolone acetonide is more effective than using each groups. It is one of the effective physical agent which delivered large molecular weight drug into the body. The continuous study is needed for many interesting issues of iontophoretic transdermal drug delivery in new future.

  • PDF

Enhanced Controlled Transdermal Delivery of Hydrochlorothiazide from an Ethylene-vinyl Acetate Matrix

  • Kim, Dal-Keun;Park, Jung-Chan;Chang, Ik-Hyun;Kang, Chung;Ryu, Sang-Rok;Shin, Sang-Chul
    • Journal of Pharmaceutical Investigation
    • /
    • v.40 no.3
    • /
    • pp.167-173
    • /
    • 2010
  • Repeated oral administration of hydrochlorothiazide, a loop diuretic, due to transient high blood levels, may cause adverse effects such as gastric disturbance, nausea, high blood sugar, and hyper lipidemia. Transdermal administration could avoid some of these systemic side effects and gastric disorders. We have developed a matrix using ethylene-vinyl acetate (EVA), a heat-processible and flexible material, for transdermal delivery of hydrochlorothiazide. Drug solubility was highest at 40% PEG-400 volume fraction. Drug release increased as concentration increased with a linear relationship between the release rate and the square root of loading dose. Increasing temperature increased drug release from the EVA matrix. The activation energy, measured from the slope of log P versus 1000/T, was 11.9 kcal/mol for a 2.5% loading dose from EVA matrix. Diethyl phthalate had the highest plasticizing effects on the release of hydrochlorothiazide. To increase the skin permeation of hydrochlorothiazide from the EVA matrix, enhancers such as the saturated fatty acids, the unsaturated fatty acids, and the non-ionic surfactants were added to the EVA matrix, and skin permeation was evaluated using a modified Keshary-Chien diffusion cell fitted with intact excised rat skin. Polyoxyethylene 23-lauryl ether showed the highest enhancing effects. In conclusion, transdermal delivery of hydrochlorothiazide could be improved from an EVA matrix containing plasticizer and permeation enhancer.

A Study on the Factors Influencing Job Satisfaction among Delivery Drivers of Online Hypermarket (온라인 대형마트 배송기사의 일자리만족도 영향 요인 연구)

  • Park, Sonhyo;Lee, Young-Min
    • The Journal of the Korea Contents Association
    • /
    • v.22 no.4
    • /
    • pp.665-676
    • /
    • 2022
  • The e-commerce had been expanding in the distribution channels, recently. Then, COVID-19 and social distancing rules led to a surge of online hypermarkets volume. In this study, we examined workplace environments of delivery drivers, firstly. Second, this study was also designed to examine the influencing factors of the perceived working environments change on the job satisfaction, dealing with the recent surge of work. We analyzed 324 data using various ways like descriptive statistics, one-way analysis of variance, factor analysis, and hierarchical regression analysis. The analysis revealed that their job satisfaction was lower than the average score and their working time was too long. In addition, the changes of the workplace environments were divided into labor intensity change and working condition change, which all had a significant effect on job satisfaction. So we should devise some long-term and short-term plans to make the level of job satisfaction among delivery drivers high on workplace environments.

A Study on the Selection of Distribution Center in the City Using GIS: With Seoul as the center (GIS를 활용한 도심 물류센터 거점 선정을 위한 연구: 서울시를 중심으로)

  • Jun, In-Sung;Ahn, Seung-Bum;Yun, Kyong-Jun
    • Journal of Korea Port Economic Association
    • /
    • v.40 no.1
    • /
    • pp.71-85
    • /
    • 2024
  • Due to the impact of COVID-19 in 2020, online growth is increasing more rapidly, and the need for MFCs has become important to strengthen the Last Mile service, especially in Gangnam and Seocho, where population density is high. This study analyzed MFC operation case studies using Arc GIS (Geographic Information System), and in the case of Seoul, delivery to four MFC bases is not possible within 30 minutes, and for delivery within 30 minutes, it is necessary to secure MFC bases in areas with many consumers. As a result of the analysis, it was confirmed that two to three MFC operating bases are needed for each region based on Seoul Metropolitan Government and at least one base for each administrative district depending on the delivery service after ordering.

Simulator for restrict adjustment of mail sorting centers: A case study (우편집중국 관할권역 조정 시뮬레이터 개발사례)

  • Cha, Byung-Chul;Kim, Wan-Seok
    • IE interfaces
    • /
    • v.20 no.4
    • /
    • pp.515-524
    • /
    • 2007
  • This paper introduces the methodology for restrict adjustment of 25 mail sorting centers including 3 new mail sorting centers to balance their work loads and minimize their operating costs. We calculated the capacity of mail sorting centers considering mail types and analyzed the collection/delivery mail volume of 214 post offices to measure the work loads of mail sorting centers. We also developed the mathematical model and genetic algorithm to find the optimal solution for this problem.

An Analysis of Efficiency in Container Shipment Cargo Volumes after Integrated Operation of Depots : Focusing on C Company (Depot 통합에 따른 출고 컨테이너 효율성 분석 : C사 모델을 중심으로)

  • Park, Byoung-Jun;Nam, Tae-Hyun;Yeo, Gi-Tae
    • Journal of Digital Convergence
    • /
    • v.16 no.9
    • /
    • pp.1-10
    • /
    • 2018
  • As the growth of warehouse stores has been accelerated, the importance of logistics for warehouse stores has been also increasing. In this respect, this study analyzed the transportation efficiency after the integrated operation of depots by C Company using GIS. According to the results of analysis of changes in container shipment cargo volumes, in terms of delivery distances, a total of 1,028,699 km of delivery car driving was shown to be necessary when one depot was operated, while a total of 2,866,604km of car driving was shown to be necessary so that 1,028,699km of car driving was reduced per year. In terms of delivery time too, 62 hours of time was saved per day and a total of 36% reduction in time could be expected. This study presented the effects of depot integration and delivery changes to improve operation processes and reduce delivery time and distances using GIS OD Matrix. The results of this study can be used as an important indicator for judgment that can affect the delivery process of other warehouse discount stores.