• Title/Summary/Keyword: Degree of dissipation

Search Result 110, Processing Time 0.022 seconds

A Study on the Pore Pressure Dissipation Test of the Piezocone (피에오콘의 간극수압 소산시험에 관한 연구)

  • 황대진;김철웅
    • Geotechnical Engineering
    • /
    • v.13 no.6
    • /
    • pp.25-36
    • /
    • 1997
  • A degree of consolidation at any time can be evaluated by using cone penetration test after soil improvement. In this case, after stopping the penetration of a piezocone, pore pressure dissipation(PPD) best is carried out until the pore pressure remains constant. Since the hydraulic conductivity of soft ground is very small, it takes very long time to finish the PPD test. This research is performed to develop a method overcoming this problem of the PPD test and reducing the test time. The analyses are carried out in the following ways : an equilibrium pore pressure can be determined by using pore pressure measured in the middle of the test, which is predicted by hyperbolic, Asaoka and Hoshino methods. And this equilibrium pore pressure is compared with the one measured in a test of long duration. As a result of the study, it is found that Hoshino method is the best way to predict the equilibrium pore pressure in a teat of short duration. And it is proposed as a methodology to fond a minimal time in which we can get an equilibrium pore pressure.

  • PDF

Seismic behavior of steel reinforced concrete special-shaped column-beam joints

  • Liu, Z.Q.;Xue, J.Y.;Zhao, H.T.
    • Earthquakes and Structures
    • /
    • v.11 no.4
    • /
    • pp.665-680
    • /
    • 2016
  • This paper focuses on the study of seismic behavior of steel reinforced concrete special-shaped column-beam joints. Six specimens, which are designed according to the principle of strong-member and weak-joint core, are tested under low cyclic reversed load. Key parameters include the steel form in column section and the ratio of column limb height to thickness. The failure mode, load-displacement curves, ductility, stiffness degradations, energy dissipation capacity and shear deformation of joint core of the test subassemblies are analyzed. The results indicate that SRC special-shaped column-beam joints have good seismic behavior. All specimens failed due to the shear failure of the joint core, and the failure degree between the two sides of joint core is similar for the exterior joint but different for the corner joint. Compared to the joints with channel steel truss, the joints with solid web steel skeleton illustrate better ductility and energy dissipation capacity, but the loading capacity and stiffness are roughly close. With the increasing of the ratio of column limb height to thickness, the joints illustrate higher loading capacity and stiffness, better energy dissipation capacity, but worse ductility.

A methodology to estimate earthquake induced worst failure probability of inelastic systems

  • Akbas, Bulent;Nadar, Mustafa;Shen, Jay
    • Structural Engineering and Mechanics
    • /
    • v.29 no.2
    • /
    • pp.187-201
    • /
    • 2008
  • Earthquake induced hysteretic energy demand for a structure can be used as a limiting value of a certain performance level in seismic design of structures. In cases where it is larger than the hysteretic energy dissipation capacity of the structure, failure will occur. To be able to select the limiting value of hysteretic energy for a particular earthquake hazard level, it is required to define the variation of hysteretic energy in terms of probabilistic terms. This study focuses on the probabilistic evaluation of earthquake induced worst failure probability and approximate confidence intervals for inelastic single-degree-of-freedom (SDOF) systems with a typical steel moment connection based on hysteretic energy. For this purpose, hysteretic energy demand is predicted for a set of SDOF systems subject to an ensemble of moderate and severe EQGMs, while the hysteretic energy dissipation capacity is evaluated through the previously published cyclic test data on full-scale steel beam-to-column connections. The failure probability corresponding to the worst possible case is determined based on the hysteretic energy demand and dissipation capacity. The results show that as the capacity to demand ratio increases, the failure probability decreases dramatically. If this ratio is too small, then the failure is inevitable.

Ductility demand of partially self-centering structures under seismic loading: SDOF systems

  • Hu, Xiaobin;Zhang, Yunfeng
    • Earthquakes and Structures
    • /
    • v.4 no.4
    • /
    • pp.365-381
    • /
    • 2013
  • In this paper, a numerical simulation study was conducted on the seismic behavior and ductility demand of single-degree-of-freedom (SDOF) systems with partially self-centering hysteresis. Unlike fully self-centering systems, partially self-centering systems display noticeable residual displacement after unloading is completed. Such partially self-centering behavior has been observed in a number of recently researched self-centering structural systems with energy dissipation devices. It is thus of interest to examine the seismic performance such as ductility demand of partially self-centering systems. In this study, a modified flag-shaped hysteresis model with residual displacement is proposed to represent the hysteretic behavior of partially self-centering structural systems. A parametric study considering the effect of variations in post-yield stiffness ratio, energy dissipation coefficient, and residual displacement ratio on the displacement ductility demand of partially self-centering systems was conducted using a suite of 192 scaled ground motions. The results of this parametric study reveal that increasing the post-yield stiffness, energy dissipation coefficient or residual displacement ratio of the partially self-centering systems generally leads to reduced ductility demand, especially for systems with lower yield strength.

The On-Line Measuring of Dissipation Factor on pole Transformer (주상 변압기의 절연유 유전정접 활선 측정 기법)

  • Lee, Su-Kil;Kim, Jae-Chul;Yoon, Yong-Han;Lee, Bo-Hoo;Kim, Oun-Seok
    • Proceedings of the KIEE Conference
    • /
    • 1996.07b
    • /
    • pp.853-855
    • /
    • 1996
  • This paper describes the dissipation factor measuring techniques of insulating oil on the operating transformer by using digital signal processing. After applying voltage to the electrodes which is installed In a transformer, acquiring source voltage and current of electrodes and using cross-correlation techniques. we can check the dissipation factor of insulating oil. To Improve measuring accuracy and the speed of process, we use hardware such as TMS320C31 DSP board and analog filter and software such as cross-correlation techniques, rectangular window, and digital filtering techniques. We simulated the measuring accuracy and the degree of the noise effect of this new measuring techniques by using computer simulation, and compared the simplified measuring devices with schering bridge on degraded insulating oil. The result showed that this measuring technique can be used as diagnostic method on the pole transformers.

  • PDF

The vertical spanning strip wall as a coupled rocking rigid body assembly

  • Sorrentino, Luigi;Masiani, Renato;Griffith, Michael C.
    • Structural Engineering and Mechanics
    • /
    • v.29 no.4
    • /
    • pp.433-453
    • /
    • 2008
  • The equation of motion of a one way (vertical) spanning strip wall, as an assembly of two rigid bodies, is presented. Only one degree of freedom is needed to completely describe the wall response as the bodies are assumed to be perfectly rectangular and are allowed to rock but not to slide horizontally. Furthermore, no arching action occurs since vertical motion of the upper body is not restrained. Consequently, the equation of motion is nonlinear, with non constant coefficients and a Coriolis acceleration term. Phenomena associated with overburden to self weight ratio, motion triggering, impulsive energy dissipation, amplitude dependency of damping and period of vibration, and scale effect are discussed, contributing to a more complete understanding of experimental observations and to an estimation of system parameters based on the wall characteristics, such as intermediate hinge height and energy damping, necessary to perform nonlinear time history analyses. A comparison to a simple standing, or parapet, wall is developed in order to better highlight the characteristics of this assembly.

Parametric study on energy demands for steel special concentrically braced frames

  • Dogru, Selcuk;Aksar, Bora;Akbas, Bulent;Shen, Jay
    • Steel and Composite Structures
    • /
    • v.24 no.2
    • /
    • pp.265-276
    • /
    • 2017
  • Structures are designed in such a way that they behave in a nonlinear manner when subject to strong ground motions. Energy concepts have been widely used to evaluate the structural performance for the last few decades. Energy based design can be expressed as the balance of energy input and the energy dissipation capacity of the structure. New research is needed for multi degree of freedom systems (MDOFs)-real structures- within the framework of the energy based design methodology. In this paper, energy parameters are evaluated for low-, medium- and high-rise steel special concentrically braced frames (SCBFs) in terms of total energy input and hysteretic energy. Nonlinear dynamic time history analyses are carried out to assess the variation of energy terms along the height of the frames. A seismic energy demand spectrum is developed and hysteretic energy distributions within the frames are presented.

An Estimation of Smear Zone Induced by Vertical Drain Construction Based on the Laboratory Model test (실내모형실험을 통한 연직배수재 타설에 의한 스미어존의 평가)

  • Kim, Hong-Taek;Han, Yeon-Jin;Kim, Seong-Wook;Hwang, Jeong-Soon
    • 한국방재학회:학술대회논문집
    • /
    • 2007.02a
    • /
    • pp.279-282
    • /
    • 2007
  • When ground disturbance takes place due to vertical drain construction through mandrel penetration, that affects excess pore water pressure dissipation time because of soft clay coefficient of permeability decreasing. Eventually, consolidation time is influenced. In this research, we measure process of excess pore water pressure dissipation before and after each other different shape's mandrel penetration through model test, and calculates range of smear zone, coefficient of permeability and horizontal coefficient of consolidation after model test. Using of test result, we grasp a degree of drainage ability drop resulting from vertical drain construction.

  • PDF

Estimation of Degree of Consolidation in Soft Ground Using Field Measurements and Rheology Model (현장 계측치와 유변학적 모형을 이용한 연약지반의 압밀도 추정)

  • Lee, Dal-Won;Yoon, Hyun-Jung
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.47 no.2
    • /
    • pp.87-96
    • /
    • 2005
  • In this research, an attempt is made to derive the practical estimation of the degree of consolidation in soft clay from field measurements under embankments. For the practical estimation of pore water pressure in soft clay, the elasto-viscous rheological model was proposed, with a transform of parameters and a field geotechnical measurements in southern Korea. By using the rheological properties of soft clays and the dissipation of excess pore water pressure behaviour during step loading, a degree of consolidation or pore water pressure estimation in the future can be performed, and are shown to be generally close to the field measurements of pore water pressure. Finally, a pore water pressure behaviour in soft clay can be explained through measured data in field and the excess pore water pressure data can also be used to estimate settlement.

Parametric study on flexible footing resting on partially saturated soil

  • Singh, Mandeep;Sawant, V.A.
    • Coupled systems mechanics
    • /
    • v.3 no.2
    • /
    • pp.233-245
    • /
    • 2014
  • Coupled finite element analysis is carried out to study the effect of degree of saturation on the vertical displacements and pore water pressures simultaneously by developing a FORTRAN90 code. The finite element formulation adopted in the present study is based upon Biot's consolidation theory to include partially saturated soils. Numerical methods are applied to a two-dimensional plane strain strip footing (flexible) problem and the effect of variable degree of saturation on the response of excess pore water pressure dissipation and settlement of the footing is studied. The immediate settlement in the case of partly saturated soils is larger than that of a fully saturated soil, the reason being the presence of pore air in partially saturated soils. On the other hand, the excess pore water pressure for partially saturated soil are smaller than those for fully saturated soil.