• 제목/요약/키워드: Defect creation

검색결과 37건 처리시간 0.037초

Zno 박막의 Helium 열처리에 대한 효과 (The effect of helium thermal treatment using ZnO thin films)

  • 유경열;;박형식;장경수;정성욱;정한욱;윤의중;이준신
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2010년도 하계학술대회 논문집
    • /
    • pp.145-145
    • /
    • 2010
  • It is observed from SEM images that many voids were created after annealed by helium gas. The PL spectra of the ZnO samples revealed the strong violet emission peaks at 3.05 eV with the relative weak near band edge UV emissions. It was concluded from experiment results that native $Zn_i$ and $V_o$ donor defect levels can be generated below the conduction band edge due to the incorporation of helium atoms decomposed from helium gas into the ZnO matrix. He atoms in ZnO matrix will affect the interface trap existing in depletion regions located at the grain boundaries, which leads to the creation of $Zn_i$ and $V_o$ donor defect levels.

  • PDF

터널화 안면동맥 협부 근점막 도피판을 이용한 구개상악 결손의 재건: 증례보고 (Tunnelized-facial Artery Myomucosal Island Flap (t-FAMMIF) for Palatomaxillary Reconstruction: A Report of Two Cases)

  • 류다정;장효원;박혜정;김형준;차인호;남웅
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • 제35권2호
    • /
    • pp.100-106
    • /
    • 2013
  • There are many challenges for reconstruction after intraoral tumor resection. Especially, palatomaxillary reconstruction has two primary goals: closure of the oronasal communication and re-creation of proper myomucosal function. Prosthodontic treatment using obturator and several surgical procedures are selected depending on the size and site of the defect, the difficulty of operative procedure, operation time and donor site problem. Above all, it is considered that radial forearm free flap is the first choice for palatal reconstruction. Our department introduces a novel method using tunnelized-facial artery myomucosal island flap for palatomaxillary defect reconstruction, which can successfully reduce donor-site morbidity, and duration of surgery and hospitalization.

유한요소법을 이용한 전방압출공정의 내부결함에 관한 연구 (A Study on Central Bursting Defects in Forward Extrusion by the Finite Element Method)

  • 김태형;이진희;권혁홍;김병민;강범수;최재찬
    • 소성∙가공
    • /
    • 제1권1호
    • /
    • pp.66-74
    • /
    • 1992
  • According to the variation of hydrostatic pressure on the central axis of deformable material, the V-shaped central bursting defect may be created in extrusion or drawing processes. The process factors which affect the generation of defects are semi-angle of die, reduction ratio of cross-sectional area, friction factor, material properties and so on. The combination of these factors can determine the possibility of defect creation and the shape of various round holes which have been created inside already. By the rigid plastic finite element method, this paper describes the observations of change in shape of round holes with process conditions such as semi-angle of die, reduction ratio of cross-sectional area and friction factor at the non-steady state of axisymmetrical extrusion process when the round hole is already existed inside the original billet. Also, the effects of process factors are investigated to prevent the possible defects.

  • PDF

박막 실리콘 태양전지의 광열화현상 연구: 비정질 실리콘 태양전지 및 나노양자점 실리콘 박막 태양전지 (Study of Light-induced Degradation in Thin Film Silicon Solar Cells: Hydrogenated Amorphous Silicon Solar Cell and Nano-quantum Dot Silicon Thin Film Solar Cell)

  • 김가현
    • 한국태양에너지학회 논문집
    • /
    • 제39권1호
    • /
    • pp.1-9
    • /
    • 2019
  • Light induced degradation is one of the major research challenges of hydrogenated amorphous silicon related thin film silicon solar cells. Amorphous silicon shows creation of metastable defect states, originating from elevated concentration of dangling bonds during light exposure. The metastable defect states work as recombination centers, and mostly affects quality of intrinsic layer in solar cells. In this paper we present results of light induced degradation in thin film silicon solar cells and discussion on physical origin, mechanism and practical solutions of light induced degradation in thin film silicon solar cells. In-situ light-soaking IV measurement techniques are presented. We also present thin film silicon material with silicon nano-quantum dots embedded within amorphous matrix, which shows superior stability during light-soaking. Our results suggest that solar cell using silicon nano-quantum dots in abosrber layer shows superior stability under light soaking, compared to the conventional amorphous silicon solar cell.

유리(遊離) 신혈류화(新血流化) 골판(骨瓣)을 이용(利用)한 가토(家兎) 불악골(不顎骨)의 재건(再建) (RECONSTRUCTION OF RABBIT MANDIBULAR DEFECT USING FREE NEOVASCULARIZED BONE FLAP)

  • 이종호;김현태;박광
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • 제18권2호
    • /
    • pp.269-278
    • /
    • 1996
  • To overcome the limitations of conventional microsurgical tissue transfer, experimental creation of various neo-flaps using the vessel implantation technique has been reported. We have performed some experiments of fabrication of neo-osseous flap with local vessels and iliac bone slabs to know that the flap vascularity and neo-angiogenesis are achieved enough to microtransfer. As a next step of our previous experiments, the flap viability and the histologic change between the recipient bone and neo-oseous flap was assessed after microsurgical transplantation. The flap was created on the rabbit femoral region(n=25) using femoral vessel and the iliac bone segments($2.5{\times}1.5cm$ in size). Three weeks after neovascularization, the newly formed flap was harvested and microtransferred to the mandibular defect. As a control, contralateral mandibular defect was created and reconstructed with conventional free iliac bone graft. Scintigrams of experimental group performed 3 days after microtransfer showed hot uptake, while that of control poor uptake. Histologic and vital stain labeling study revealed good bone viability and vascularity of neo-osseous flap. In conclusion, prefabricated neo-osseous flap of our model could be transferred to the recipient site with retaining the flap viability and showed advantages over the conventional bone graft in that it was living bone graft.

  • PDF

상행 대동맥에서의 우폐동맥 이상기시증을 동반한 복잡 심기형의 단계적 완전 교정술-1례 보고- (Staged Total Correction of Complexes Anomalous Origin of Right Pulmonary Artery from the Ascending Aorta One Case Report)

  • 정일상;한재진
    • Journal of Chest Surgery
    • /
    • 제30권3호
    • /
    • pp.322-325
    • /
    • 1997
  • 세종병원 흉부외과에서는 폐동맥 페색증, 좌측폐동맥 무형성증, 심실중격결손증, 다발성 MAPCA등을 동반한 상행 대동맥으로부터 이상기시한 우폐동맥 11례를 경험하였다. 10개월 때 1단계 수술로써 좌측 unifocalization과 함께 좌폐동맥을 만들고 우폐동맥 벤딩을 하였고, 1개월후 우측 MAPCA의 coil 색전술 단계를 거쳐, 1년후 완전 교정술을 시행하였다. 술후 경과는 양호하였고 수술 1년후 조영술과 혈역학적 검사상 만족스런 결과를 얻을 수 있었다.

  • PDF

알루미늄 Metal Depression에 관한 연구 (An investigation on the metal depression of aluminum)

  • 김태건;김남훈;김상용;이우선;장의구
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2005년도 추계학술대회 논문집 Vol.18
    • /
    • pp.86-87
    • /
    • 2005
  • Aluminum(Al) sputtering is best known method to form Al film for the Si wafer in the process of 180nm and above. In the Al metal line process, one of the frequently founded and well-known defect was metal depression. In this paper, several experiments were performed such as temperature, Ar gas flow rate, thickness change in other to reduce the metal depression and find the origination of metal depression. Through experiments, it is found that metal depression was significantly related to the temperature. And the Ar gas flow rate did not influence to the creation of depression. The off status ESC also showed stable metal film without depression by same mechanism of temperature decrease. Also, thickness is strongly influence to the metal depression.

  • PDF

좌관상동맥동에서 이상 기시하는 유관상동맥 질환에서 새로운 개구부를 만드는 Extended Unroofing 수술 - 1예 보고 - (Extended Unroofing Procedure for Creation of a New Ostium for an Anomalous Right Coronary Artery Originating from the Left Coronary Sinus - A case report -)

  • 박정식;이향림;김건우;최창휴;이재익;전양빈;박국양;박철현
    • Journal of Chest Surgery
    • /
    • 제41권1호
    • /
    • pp.102-105
    • /
    • 2008
  • 대혈관 사이로 주행하는 관상동맥의 이상 기시는 매우 드문 심기형으로 심근허혈이나 급사를 초래할 수 있다. 이런 기형을 교정하기 위해 몇몇 술식들이 소개되어 왔다. 우관상동맥의 이상기시 환자에서 우관상동맥의 또 다른 개구부를 만들어주는 Extended Unroofing 술식을 성공적으로 수행하였다. 술 후 3개월 째 심근허혈이나 대동맥판막역류증 없이 새로 만든 개구부는 넓게 잘 유지되었다.

Wound healing effect of regenerated oxidized cellulose versus fibrin sealant patch: An in vivo study

  • Yoon, Hyun Sik;Na, Young Cheon;Choi, Keum Ha;Huh, Woo Hoe;Kim, Ji Min
    • 대한두개안면성형외과학회지
    • /
    • 제20권5호
    • /
    • pp.289-296
    • /
    • 2019
  • Background: Topical hemostatic agents are used when ligation, electrocauterization, or other conventional hemostatic methods are impractical. Because a hemostatic agent is a foreign body, it can cause foreign body reactions, inflammation, and infections that can interfere with the wound healing process. Therefore, we should select hemostatic agents after considering their effects on wound healing. Here, we compared the effects of hemostatic agents on wound healing in a rectus abdominis muscle defect in rats. Methods: Twelve Sprague Dawley rats were subjected to creation of a $6{\times}6mm$ defect in the rectus abdominis muscle and divided into four groups: control group; group A, Tachosil fibrin sealant patch; group B, Surgicel Fibrillar oxidized regenerated cellulose; and group C, Surgicel Snow oxidized regenerated cellulose. For the histologic analysis, biopsies were performed on the 3rd, 7th, and 27th days. Results: The foreign body reaction was the weakest in group A and most significant in group C. The inflammatory cell infiltration was the weakest in group A and similar in groups B and C. Muscle regeneration differed among periods. The rats in group A were the most active initially, while those in group C showed prolonged activity. Conclusion: Tachosil and Surgicel administration increased inflammation via foreign body reactions, but the overall wound healing process was not significantly affected. The increased inflammation in the Surgicel groups was due to a low pH. We recommend using Tachosil, because it results in less intense foreign body reactions than Surgicel and faster wound healing due to the fibrin action.

Evaluation of bone substitutes for treatment of peri-implant bone defects: biomechanical, histological, and immunohistochemical analyses in the rabbit tibia

  • dos Santos, Pamela Leticia;de Molon, Rafael Scaf;Queiroz, Thallita Pereira;Okamoto, Roberta;de Souza Faloni, Ana Paula;Gulinelli, Jessica Lemos;Luvizuto, Eloa Rodrigues;Garcia, Idelmo Rangel Junior
    • Journal of Periodontal and Implant Science
    • /
    • 제46권3호
    • /
    • pp.176-196
    • /
    • 2016
  • Purpose: We sought to evaluate the effectiveness of bone substitutes in circumferential periimplant defects created in the rabbit tibia. Methods: Thirty rabbits received 45 implants in their left and right tibia. A circumferential bone defect (6.1 mm in diameter/4 mm depth) was created in each rabbit tibia using a trephine bur. A dental implant ($4.1mm{\times}8.5mm$) was installed after the creation of the defect, providing a 2-mm gap. The bone defect gaps between the implant and the bone were randomly filled according to the following groups: blood clot (CO), particulate Bio-Oss$^{(R)}$ (BI), and Bio-Oss$^{(R)}$ Collagen (BC). Ten animals were euthanized after periods of 15, 30, and 60 days. Biomechanical analysis by means of the removal torque of the implants, as well as histologic and immunohistochemical analyses for protein expression of osteocalcin (OC), Runx2, OPG, RANKL, and TRAP were evaluated. Results: For biomechanics, BC showed a better biological response ($61.00{\pm}15.28Ncm$) than CO ($31.60{\pm}14.38Ncm$) at 30 days. Immunohistochemical analysis showed significantly different OC expression in CO and BC at 15 days, and also between the CO and BI groups, and between the CO and BC groups at 60 days. After 15 days, Runx2 expression was significantly different in the BI group compared to the CO and BC groups. RANKL expression was significantly different in the BI and CO groups and between the BI and BC groups at 15 days, and also between the BI and CO groups at 60 days. OPG expression was significantly higher at 60 days postoperatively in the BI group than the CO group. Conclusions: Collectively, our data indicate that, compared to CO and BI, BC offered better bone healing, which was characterized by greater RUNX2, OC, and OPG immunolabeling, and required greater reversal torque for implant removal. Indeed, along with BI, BC presents promising biomechanical and biological properties supporting its possible use in osteoconductive grafts for filling peri-implant gaps.