• Title/Summary/Keyword: Dedicated System

Search Result 864, Processing Time 0.029 seconds

An Experimental Study on Four-season Dedicated Outdoor Air Handling Unit (사계절 외기 전용 공조기에 대한 실험적 연구)

  • Park, Seung-Tae;Kim, Jong-Cheon;Hong, Young-Ju;Kim, Youn-Gil
    • Proceedings of the SAREK Conference
    • /
    • 2008.06a
    • /
    • pp.577-582
    • /
    • 2008
  • The present study has been conducted to study the performance of Dedicated outdoor air handling unit. Dedicated outdoor air handling unit consists of pre-cooler, dehumidification and after cooler. By combining dedicated outdoor air-conditioning and heat pump, a new four-season dedicated outdoor air handling unit has been developed. Amount of energy saved and condition when this new system is superior to conventional vapor-compression cooling system has been presented.

  • PDF

A Lagrangian Relaxation Approach to Capacity Planning for a Manufacturing System with Flexible and Dedicated Machines

  • Lim, Seung-Kil;Kim, Yeong-Dae
    • Journal of the Korean Operations Research and Management Science Society
    • /
    • v.23 no.2
    • /
    • pp.47-65
    • /
    • 1998
  • We consider a multiperiod capacity planning problem for determining a mix of flexible and dedicated capacities under budget restriction. These capacities are controlled by purchasing flexible machines and/or new dedicated machines and disposing old dedicated machines. Acquisition and replacement schedules are determined and operations are assigned to the flexible or dedicated machines for the objective of minimizing the sum of discounted costs of acquisition and operation of flexible machines, new dedicated machines, and old dedicated machines. In this research, the Problem is formulated as a mixed integer linear Program and solved by a Lagrangian relaxation approach. A subgradient optimization method is employed to obtain lower bounds and a multiplier adjustment method is devised to improve the bounds. We develop a linear programming based Lagrangian heuristic algorithm to find a good feasible solution of the original problem. Results of tests on randomly generated test problems show that the algorithm gives relatively good solutions in a reasonable amount of computation time.

  • PDF

A Converging Exact Algorithm for Determining an Optimal 3-Class-Based Dedicated Linear Storage System

  • Yang Moon-Hee
    • Management Science and Financial Engineering
    • /
    • v.12 no.1
    • /
    • pp.79-94
    • /
    • 2006
  • In this paper, we readdress a layout design problem, PTL[3], for determining an optimal 3-class-based dedicated linear storage layout in a class of unit load storage systems. Based on some fundamental properties derived, we provide a converging exact algorithm with O(n[logn]), which is more efficient than that of Yang and Kim [8] and can be applied to PTL[K] with $K{\ge}4$ in order to reduce computational execution time. In addition, we prove that the necessary condition suggested by them is also a sufficient condition to PTL[3].

A dedicated line operating and maintenance system design based on UML (UML 기반 전용회선 운용관리시스템 설계)

  • 조동권
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.6 no.6
    • /
    • pp.827-832
    • /
    • 2002
  • The development of dedicated network management system is essential to meet the following conditions: the system must run the configuring and repair processing for the dedicated communication network, and can manage new next generation data dedicated communication network of various types. In general it is effective that the system is consisted of decentralized module to be accessible for business logic and datum to remote area. To solve these problems, a method is to use object-oriented design techniques. That is, it is to abstract reusability objects and make component module using the abstracted objects. In this paper, we propose a management system of dedicated communication network service using object-oriented design techniques which are UML(Unified Modeling Language).

A Study on Processing of Monolithic Rack Housing for Modular Steering Gear [II] - Processing Characteristics of Monolithic Rack Housing - (Steering Gear 모듈화를 위한 일체형 Rack Housing의 공정에 관한 연구 [II] - 일체형 Rack Housing의 공정특성 -)

  • Kim, Jong-Do;Lee, Chang-Je
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.33 no.2
    • /
    • pp.288-294
    • /
    • 2009
  • The purpose of this study is manufacturing of monolithic housing for modularization of steering gear. Monolithic housing is difficult to weld with only rotation and linear motion. It is for this reason that housing of joining parts have a slope of 76.3 degrees. For this reason, welding trajectory was measured by the cooperative controled robot system, and then allowing for measured results, we developed the dedicated system. The developed system can be welded by using only 3 axises in contrast with robot system using 8 axises in housing welding. In addition, we applied CMT and laser welding device to dedicated system and as a result of experiment, sound bead and excellent roundness could be obtained.

Development of a Dedicated CAM System for Human Bust Machining (흉상 환조 가공을 위한 전용 CAM시스템 개발)

  • Jeong, Hoi-Min;Park, Joon-Chul;Chung, Yun-Chan
    • IE interfaces
    • /
    • v.15 no.2
    • /
    • pp.147-151
    • /
    • 2002
  • Presented in this paper is a prototype of dedicated CAM system for a human bust, not a relief, machining. The input of this system is a STL file which comes from measuring machine, and the output is machining data for a 3-axis CNC milling machine with an index table. The system consists of three main modules, which are shape import and transformation, modeling of jig and fixture, and calculation of machining area. Proposed system architecture and the main modules are briefly described. To get machining region for semi-finish and finish machining stages, two concepts of machining area, machinable and scannable, were tried. Machinable area was suitable for the purpose.

Electronic Parking Collection System using DSRC System at Parking Lot (DSRC 시스템을 이용한 주차장 자동요금정산시스템)

  • 최광주;김동현;현영균;지정재;이재형
    • Proceedings of the IEEK Conference
    • /
    • 2000.11a
    • /
    • pp.421-424
    • /
    • 2000
  • In this paper, We presented overview and characteristics of ITS(Intelligent Transport System) DSRC(Dedicated Short Range Communication) system that was introduced to the basic installation for ITS service and proposed system architecture and implementation methods to realize automatic collection of parking charge using DSRC system.

  • PDF

An Exact Splitting Algorithm for a 4-Class-Based Dedicated Linear Storage Problem

  • Yang, Moon-Hee;Choi, Chang-Hwan;Kim, Hee
    • Management Science and Financial Engineering
    • /
    • v.17 no.2
    • /
    • pp.23-37
    • /
    • 2011
  • In this paper, we address a layout design problem for determining an optimal 4-class-based dedicated linear storage layout in a class of unit load storage systems. Assuming that space requirement for a class is the sum of the maximum inventory levels of products assigned to the class, and that one-way travel time is a linear function of storage index, we formulate a 4-class-based dedicated linear storage problem PTL[4] and provide an exact splitting algorithm with $O(n{\lceil}logn{\rceil})$. Our algorithms could be applied to more than a 4-class-based dedicated storage layout problem with slight modification in order to reduce computational execution time.

Application of Four-season Dedicated Outdoor Air Handling Unit in Central and Personal Air-conditioning (중앙공조 및 개별공조에서의 외조기 적용)

  • Park, Seung-Tae;Kim, Young-Il;Lee, Tae-Ho;Choi, Se-Young
    • Proceedings of the SAREK Conference
    • /
    • 2008.06a
    • /
    • pp.591-596
    • /
    • 2008
  • The present study has been conducted to study the performance of dedicated outdoor air handling unit in central and personal air-conditioning. With conventional central and personal air-conditioning systems which are designed according to the maximum load, humidity increase above comfort level can not be avoided as the cooling load decreases. The adoption of dedicated outdoor air handling unit, however, can solve this problem. Moreover, the dedicated outdoor air handling unit has the characteristics of anti-bacteria due to dry coil, energy saving and good indoor air quality. During cooling seasons, dedicated outdoor air handling unit can save energy up to 30% than the conventional cooling+reheating system for controlling both temperature and humidity.

  • PDF

Calculation Method of Dedicated Transmission Line's Meteological Data to Forecast Renewable Energy (신재생에너지 예측을 위한 송전선로의 계량 데이터 계산 방법)

  • Ja-hyun, Baek;Hyeonjin, Kim;Soonho, Choi;Sangho, Park
    • KEPCO Journal on Electric Power and Energy
    • /
    • v.8 no.2
    • /
    • pp.55-59
    • /
    • 2022
  • This paper introduce Renewable Energy forecasting technology, which is a part of renewable management system. Then, calculation method of dedicated transmission line's meteorological data to forecast renewable energy is suggested. As the case of dedicated transmission line, there is only power output data combined the number of renewable plants' output that acquired from circuit breakers. So it is need to calculate meteorological data for dedicated transmission line that matched combined power output data. this paper suggests two calculation method. First method is select the plant has the largest capacity, and use it's meteorological data as line meteorological data. Second method is average with weight that given according to plants' capacity. In case study, suggested methods are applied to real data. Then use calculated data to Renewable forecasting and analyze the forecasting results.