• Title/Summary/Keyword: Dead Volume

Search Result 134, Processing Time 0.024 seconds

A Basic Survey about Dead Tree of Old Korean Fir Stands in Mt. Sorak (내설악 전나무 고목림에 존재하는 고사목에 관한 기본 자료조사)

  • 장동원;윤영일
    • Korean Journal of Environmental Biology
    • /
    • v.21 no.3
    • /
    • pp.251-256
    • /
    • 2003
  • Baseline data on the type, species and volume for dead trees were collected from old growth fir (Abies holophylla) forest in Sorak National Park. Though the survey was restricted to fly forest, a basic data compatible to those in other countries were collected. Besides fir, dead trees were also found in deciduous species. All the Known dead tree types were found. Average volume of dead tree in the surveyed area was 00.42 $\textrm{m}^2 \; ha^{-1}$. There seems no correlation existing between the distributions of dead tree and coarse woody debris (CWD).

An Experimental Study on Performance of the Inertance Pulse Tube Refrigerator using a Small Compressor (소형 압축기를 이용한 관성관형 맥동관 냉동기의 성능 특성에 대한 실험적 연구)

  • Kim Hongseong;Jeong Sangkwon
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.17 no.6
    • /
    • pp.552-559
    • /
    • 2005
  • This paper describes an experimental study on the inertance pulse tube refrigerator using a small compressor. The purpose of this experimental study is to identify the performance of the inertance pulse tube refrigerator for various operating conditions and to obtain the optimum configuration. The dead volume effect is verified by two experimental apparatuses with different dead volumes between the compressor and the aftercooler. The refrigerator of the smaller dead volume shows better performance. The influence of operating frequency and charging pressure on the performance of the refrigerator is experimentally investigated. Reducing the regenerator mesh size improves the performance of the refrigerator. Finally, the inertance pulse tube refrigerator has maximum cooling capacity at the specific combination of the pulse tube length and the inertance tube length. The loss analysis is used to analyze and predict the optimum condition of the pulse tube refrigerator.

The Effects of Artificial Dead Space on the Pulmonary Ventilation of Intubated Children with Mechanical Ventilation (기관 삽관후 인공호흡기를 적용한 개심술 환아의 인공기도 체외 용적이 폐환기 상태에 미치는 영향)

  • 유정숙;윤선희;송계희;민열하
    • Journal of Korean Academy of Nursing
    • /
    • v.31 no.1
    • /
    • pp.31-42
    • /
    • 2001
  • This study was done to evaluate the effect reducing artificial dead space on intubated children. Data were collected from July 1st, 1998 to August 31st, 1999. The subjects were selected from a pediatric intensive care unit of 'S' hospital and intubated with 3.5 mm or 4.5 mm endotracheal tube after open heart surgery. They were composed of 34 patients : 17 patients were assigned to the experimental group and the rest of them were placed in the control group. The artificial airway volume was minimized in the experimental group, and the control group maintained the artificial airway volume. ETCO2, PaCO2, SPO2 were measured as indicators of pulmonary ventilation. The tools of this study were GEM-Premier and Space-Lab patient monitors. The data were analyzed using the SPSS/PC+ program. The $\chi$2 -test was used to find general characteristics. The t-test was used to test the homogenety of the pulmonary ventilation status and mechanical ventilation setting before intervention between the two groups. Also, the paired t-test was used to examine the hypothesis. The results can be summerized as : 1. CO2 can be expelled effectively from the body in case artificial dead space was decreased. 2. As the artificial dead space was reduced, the difference between ETCO2 and PaCO2 was decreased, in other words pulmonary ventilation was improved. 3. If the artificial dead space occupied above 15 percent of tidal volume, the effect of CO2 was retention revealed in the body. 4. If the artificial dead space occupied below effect. Based on the results, the following is suggested to be applied practically : 1. A kind of the ventilator circuit acting artificial dead space should be removed from the intubated children with mechanical ventilaion. 2. The endotracheal tube should not be cut because extra-body space of the endotracheal tube did not have an effect on the dead space of the intubated children. Since the researcher could not cover this aspect in the study, they recommend the following. 1. The study should be extended to the other pulmonary disease patients for the effect of improving pulmonary ventilation. 2. Also, further studying with a more narrow interval in the extra-body space of the artificial airway will be able to explain the point of artificial dead space with proper ventilation.

  • PDF

Preliminary Design Conditions for a Thermally Actuated Refrigerator Based on the Vuilleumier Cycle (Vuilleumier 사이클로 작동되는 열구동 냉동기의 예비설계조건)

  • 유호선;강병하
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.16 no.12
    • /
    • pp.2358-2367
    • /
    • 1992
  • This paper deals with preliminary design conditions for a thermally actuated Vuilleumier refrigerator/heat pump. The previously reported approximate adiabatic analysis which is based on the 8-volume model makes it possible to evaluate exchanged heats per cycle as well as cyclic pressure, temperature and mass variation of each working volume. Calculated results reveal not only there exists an optimum value for the phase angle and the swept volume ratio maximizing a specific thermal output, but also design parameters can be determined independently of each other. Under a given combination of operating temperature levels, the optimum conditions for refrigeration are different from those for heat pumping and the differences between two operating modes become larger with decreasing the dead volume ratio. Both the optimum phase angle and the optimum swept volume ratio are increased asymptotically toward 0.5 pi and 1.0 respectively, as the dead volume ratio approaches to unity. When a VM machine is used for cooling and heating simultaneously, the design parameters should be carefully determined to reach the best performance.

Evaluation of hydraulic dead-zone and particle removal efficiency in the base frame of a constructed wetland using computational fluid dynamics (인공습지 기본형상에서 전산유체역학을 이용한 사류구간 및 입자제거율 평가)

  • Choi, Young-Gyun;Park, Min-Cheol
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.27 no.4
    • /
    • pp.495-502
    • /
    • 2013
  • Hydraulic dead-zone and particle removal efficiency in the base frame of a constructed wetland was evaluated with computational fluid dynamics (CFD). The fraction of hydraulic dead-zone was estimated to be 1.2-2.1 % (v/v) and it was attributed to the artificial islands developed in the constructed wetland. Solids deposition rate could be increased with higher hydraulic retention time (HRT, ranged from 2.2 to 4.2 hr) of the wetland and larger particle size (ranged from 10 to $50{\mu}m$) in the influent. Experimental results showed that the volume concentration of the particles smaller than $10{\mu}m$ in diameter was varied from $1.99{\times}10^3{\mu}m^3/ml$ (HRT 12.8 hr) to $3.92{\times}10^3{\mu}m^3/ml$(HRT 2.2 hr) in the influent of the constructed wetland. With the effluent volume concentration data, removal efficiency of those particles was calculated to be 71.2 and 24.7 % when the HRT was 12.8 and 2.2 hr, respectively. Similar trend with the HRT variation could be identified with CFD analysis.

Plan Study of Improvement on Thermal Flow at Computer Main Frame (컴퓨터 본체 구조의 열유동에 관한 개선 방안 검토)

  • Cho, Jae-Ung;Han, Moon-Sik
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.10 no.1
    • /
    • pp.23-30
    • /
    • 2011
  • This study is to analyze the internal flow at the inside of computer case which is commonly used. The inner configuration are modelled and simulation analysis is done by ANSYS-CFX. Dead volume is happened according to the positioning of VGA and HDD. The advanced model is suggested by removing this volume and making the smooth cooling flow. This model is formed with the constraint conditions same as the existing model. As compared with the existing model, flow configuration is different and the average temperature becomes lower through flow analysis about the advanced model.

Small Hydrogen Regulator for Mobile Fuel Cells (모바일 연료전지용 초소형 수소 레귤레이터)

  • Kim, Hyung-Jin;Seo, Young-Ho;Kim, Byeong-Hee
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.20 no.2
    • /
    • pp.129-132
    • /
    • 2011
  • This paper presents small hydrogen regulator for the mobile fuel cell. Mobile fuel cell is generally classified into open-end type and dead-end type. In the open-end type, flow rate of hydrogen is constantly controlled, while pressure of hydrogen is constantly maintained in the dead-end type. Considering the efficiency and stability of the fuel usage, dead-end type is more suitable with mobile fuel cell. Mobile fuel cell operated by dead-end mode requires hydrogen regulator which controls the hydrogen pressure from 0.1bar to 0.5bar within 3% error. In this paper, small hydrogen regulator (volume of 2.6cc) was fabricated by stainless steel. Regulation characteristics was experimentally evaluated.

Flow Characteristics of a Small Engine Intake Port (소형엔진 흡기포트의 유동특성)

  • Lee, Joo-Hyung;Park, Sung-Young
    • Proceedings of the KAIS Fall Conference
    • /
    • 2009.12a
    • /
    • pp.520-525
    • /
    • 2009
  • 본 연구은 해석적인 접근을 통하여 소형엔진 흡기포트 설계인자의 변화에 따른 유량계수를 고찰하였다. 기존모델을 Valve Lift별 유량계수들을 해석하였으며 그 중 유량계수가 일정해지는 구간의 Valve Lift를 기준으로 설계인자 변화에 따른 성능해석을 수행하였다. 결론적으로, 흡기포트 유량계수를 결정하는 중요한 인자는 포트각도와 유선형상임을 확인하였고 이들 값의 최적화를 수행하였다. 흡기포트의 유량계수를 결정하는 설계인자로는 포트각도, 흡기포트의 유선형상, Port Height_Guide, Flange 면적이 있다. 포트각도의 상승이 유량계수를 상승시키지만 그에 따른 굴절 및 Dead Volume의 발생으로 오히려 유량계수 측면에서는 불리한 조건이 되기도 한다. 급격한 형상변화 부분에서 박리현상이 발생되는데 이에 유동을 위한 곡률을 적용하여 급격한 형상변화를 줄여 박리형상을 감쇄시키고, Dead Volume 삭제하여 원활한 유동특성을 만들 수 있다.

  • PDF

A Study on the Reliability of a Dual Capacity Reciprocating Compressor (이중용량 왕복동 압축기 신뢰성 확보에 대한 연구)

  • Kim, Jong-Bong
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.26 no.7
    • /
    • pp.81-90
    • /
    • 2009
  • Due to environmental issues, the development of low energy consumption products has become one of the main topics in the home appliance industry. The energy consumption of a refrigerator depends on the efficiency of its compressor as well as on the refrigerator cycle design, such as the capacity modulation. In this study, a dual capacity, i.e., two-step capacity modulation (TCM), reciprocating compressor is developed. In a TCM compressor, capacity modulation is achieved by changing the dead volume in the cylinder. Instead of a concentric sleeve, an eccentric sleeve, a key, and a spring are used to change the dead volume for the clockwise and counterclockwise rotation of a motor. When the compressor changes its operating mode from full capacity to partial capacity or in opposite direction, the key may collide with the eccentric sleeve. The structural reliability and mode change reliability were confirmed by analysis and experiment.