• Title/Summary/Keyword: Daylighting Design

Search Result 100, Processing Time 0.023 seconds

Optical Fiber Daylighting System Combined with LED Lighting and CPV based on Stepped Thickness Waveguide for Indoor Lighting

  • Vu, Ngoc Hai;Shin, Seoyong
    • Journal of the Optical Society of Korea
    • /
    • v.20 no.4
    • /
    • pp.488-499
    • /
    • 2016
  • We present a design and optical simulation of a cost-effective hybrid daylighting/LED system composed of mixing sunlight and light-emitting diode (LED) illumination powered by renewable solar energy for indoor lighting. In this approach, the sunlight collected by the concentrator is split into visible and non-visible rays by a beam splitter. The proposed sunlight collector consists of a Fresnel lens array. The non-visible rays are absorbed by the solar photovoltaic devices to provide electrical power for the LEDs. The visible rays passing through the beam splitters are coupled to a stepped thickness waveguide (STW) by tilted mirrors and confined by total internal reflection (TIR). LEDs are integrated at the end of the STW to improve the lighting quality. LEDs’ light and sunlight are mixed in the waveguide and they are coupled into an optical fiber bundle for indoor illumination. An optical sensor and lighting control system are used to control the LED light flow to ensure that the total output flux for indoor lighting is a fixed value when the sunlight is inadequate. The daylighting capacity was modeled and simulated with a commercial ray tracing software (LighttoolsTM). Results show that the system can achieve 63.8% optical efficiency at geometrical concentration ratio of 630. A required accuracy of sun tracking system achieved more than ±0.5o . Therefore, our results provide an important breakthrough for the commercialization of large scale optical fiber daylighting systems that are faced with challenges related to high costs.

Predicted Performance of the Integrated Artificial Lighting System in Relation to Daylight Levels (채광시스템과 인공조명설비의 통합기술 및 성능평가연구)

  • Kim, G.;Kim, J.T.
    • Journal of the Korean Solar Energy Society
    • /
    • v.22 no.3
    • /
    • pp.47-56
    • /
    • 2002
  • The office is an excellent candidate for implementing daylighting techniques because of the relatively high electric lighting power densities and long daytime use pattern. The quantity of light available for a space can be translated in term of the amount of energy savings through a process of a building energy simulation. To get significant energy savings in general illumination, the electric lighting system must be incorporated with a daylight - activated dimmer control. A prototype configuration of an office interior has been established and the integration between the building envelope and lighting and HVAC systems is evaluated based on computer modeling of a lighting control facility. First of all, an energy-efficient luminaire system is designed for both a totally open-plan office interior and a partitioned office. A lighting design and analysis program, Lumen-Micro 2000 predicts the optimal layout of a conventional fluorescent lighting fixture to meet the designed lighting level and calculates unit power density, which translates the demanded amount of electric lighting energy. A dimming control system integrated with the contribution of daylighting has been applied to the operating of the artificial lighting. Annual cooling load due to lighting and the projecting saving amount of cooling load due to daylighting under overcast diffuse sky are evaluated by a computer software, ENER-Win. In brief, the results from building energy simulation with measured daylight illumination levels and the performance of lighting control system indicate that daylighting can save over 70 percent of the required energy for general illumination in the perimeter zones through the year. A 25 % of electric energy for cooling may be saved by dimming and turning off the luminaires in the perimeter zones.

A Study on Design Tendencies in Office Buildings of Public Institutions after Reinforcement of the Building Energy Performance Criteria in Korea (건물에너지성능기준 강화 이후 국내공공기관 업무용 건축물의 디자인경향)

  • Lee, Ah-Young
    • KIEAE Journal
    • /
    • v.11 no.6
    • /
    • pp.139-149
    • /
    • 2011
  • This study focuses on design tendencies in office buildings of public institutions after tightening up Korea's building energy performance criteria. Important office design criteria and recommendations pay attention to the issues such as building orientation, greening buildings, building form, space and envelop by intensifying building energy performance related laws, government guidelines and evaluation systems. The design tendencies explored in this research are as follows. Office buildings mainly face south and have various types of indoor and roof green spaces not for ecological reasons but for the rest. Building depth becomes thinner and atria are inserted into office buildings to improve daylighting and natural ventilation. Building cores are located on north or west and east sides acting as buffer spaces to reduce heat loss and to block solar radiation. Office building envelop design includes various creative ideas to control or utilize solar energy as like three dimensional or double structured skin and window size variation to cope with the intensity of solar radiation. Further, solar energy generation systems are integrated with building component such as roofs, sun screens and windows. This study demonstrates that government's reinforcement of the building energy performance criteria drives the change in design methods and approach.

Evaluation of Daylighting Performance in Office Building with Detailed Global Illuminance Data of Selected Korean Cities (정밀 전천공조도 데이터를 활용한 국내 주요도시 업무용 건물의 자연채광 활용성능 평가)

  • Choi, Su-Hyun;Shin, Sang-Yong;Seo, Dong-Hyun
    • Journal of the Korean Solar Energy Society
    • /
    • v.36 no.6
    • /
    • pp.37-46
    • /
    • 2016
  • In this study, long-term global illuminance data for 19 selected cities are calculated from modeled solar radiation data, AEER's TMY2. Perez model in Daysim daylight simulation tool is used for the solar radiation to illuminance conversion. And then, daylight availability in an unit office space is evaluated for the 19 cities. For this evaluation, various daylight performance indices are reviewed since static daylight performance index such as daylight factor (DF) and annual average global illuminance value is not suitable for actual performance evaluation in terms of visual comfort and light energy saving of a space. This study evaluated daylighting performance of prototypical office space module by introducing DA (daylight autonomy) and UDI (Useful Daylight Illuminance) index for major cities of Korea. Result shows that there is upto 18% of illuminance level difference with annual average global illuminance data, but if we consider useful daylight in a space the illuminance level difference among the cities are only within 5%. This means that for sustainable building design especially in daylight design, amount of annual global illuminance is not important factor even in cloudy cities. Daylight design and daylight harvesting system would return similar energy saving impact regardless of building location.

A Study on the Performance of a Hybrid Daylighting System Using AVR Microcontrollers (AVR Microcontroller를 이용한 하이브리드 자연채광시스템의 성능에 관한 기초연구)

  • Lim, Sang Hoon;Oh, Seung Jin;Kim, Won-Sik;Jeong, Hae-Jun;Chun, Wongee
    • Journal of the Korean Solar Energy Society
    • /
    • v.35 no.6
    • /
    • pp.1-7
    • /
    • 2015
  • This paper deals with the design and operation of a hybrid daylighting system that uses natural and artificial lighting to enhance visual comfort in buildings. The system was developed using an AVR micro controller for solar tracking in conjunction with dimming controls, which, acting together, enables the maximum use of natural daylight and also improves energy efficiency in buildings. Experimental results clearly demonstrates the usefulness of the present system capable of enhancing indoor lighting conditions when sufficient daylight is available and distributed appropriately in harmony with artificial lighting.

Scale Model Experiment on Daylighting of Differentiated Glazing System (축소모형을 이용한 분할형 유리 투과체 창호시스템의 채광성능실험)

  • Jeong, In Young;Kim, Jeong Tai
    • KIEAE Journal
    • /
    • v.4 no.4
    • /
    • pp.61-68
    • /
    • 2004
  • Daylight is a critical factor in architecture, as it helps enhance the working efficiency and pleasantness of the people working inside, in addition to reduce the power consumption in heating and cooling and make the interior space brighter. There are many kinds of glazing and daylighting systems. At present, research and efforts for their development are carried out, alongside quantitative evaluation. This study aims to present basic materials to be used to design proper glazing and daylighting systems in architecture based on a quantitative evaluation by scale models of existing office buildings. The result of the study can be summarized as follows. 1)As a result of the experiment, it appeared that the ratio of the interior illumination (i.e. at the working table, ceiling and wall) against the outdoor illumination increases at a constant rate, as the transmittance of the glazing goes up. 2) It was found that the SIR(Sunlight Illuminance Ratio) of a separated window system goes up by 20-50% at the rear part than in the case of an ordinary window system.

An Analysis of Illuminance Distribution in Fine Art Museum with Girdle Skylight Type (미술관에서의 상부 띠형 천창의 채광분포에 관한 연구)

  • Choi, Man-Jin
    • Journal of the Korean Solar Energy Society
    • /
    • v.25 no.4
    • /
    • pp.93-100
    • /
    • 2005
  • Character and illuminance distribution of daylighting is very important for the architectural plan in museum. Those data show bases for exhibition space design with daylighting and play a decisive role in visual perception of articles and space aesthetic. The goal of this paper was therefore to analyze the illuminance distribution in fine art museum with 3 typical girdle skylight types which are devided according to the art of protection from glare. This Experiment proved that they had a striking contrast with regard to the ratio of daylight illumination and illuminance distribution in spite of the same purpose of those development. The girdle skylight with a translucent glass showed the strongest value of the ratio of daylight illumination, but inequable illuminance distribution in space, excepting the area of the wall. However, the latticed reflector of light refracted daylight in the direction of wall and made illuminance distribution very equable in whole space. The ratio of daylight illumination at the girdle skylight which was located at the verge of the ceiling, was highest at the upper part of the wall and was reduced gradually from there, by way of the middle and under part of the wall, to the center of space.

Evaluation Study of a Double Blind Light Pipe Daylighting System Efficiency and an Illumination Energy Reduction (이중 블라인드 광파이프 주광 조명시스템 효율 및 조명에너지 절감량 평가 연구)

  • Kang, Eun-Chul;Yoo, Seong-Yeon;Lee, Euy-Joon
    • Journal of the Korean Solar Energy Society
    • /
    • v.33 no.1
    • /
    • pp.89-95
    • /
    • 2013
  • A DBLP(Double blind light pipe) daylight system can be installed at a building exterior wall or roof to replace artificial light during the day time. This system was consisted of a double blind light collector, a mirror duct type light transformer and a prism light pipe distributor. The double blinds were used to track the sun's altitude and azimuth movements to collect the sunlight throughout the day. The sunlight collected by the light collector was reflected on the first mirror and the second mirror and sent to the light pipe through the light transformer. The transformer was designed to deliver the sunlight into the light pipe efficiently. The light distributor plays a role in diffusing the sunlight coming in through the light collector to be used for indoor lighting. In this paper, a DBLP system has been designed, installed and tested at a KIER daylighting twin test cell. The DBLP daylighting system was applied to the experimental test cell which has an indoor area of 2.0 m wide ${\times}$ 2.4 m height ${\times}$ 3.8 m length. The experiment was conducted from January 30 to February 27, 2012, under clear skies and partially cloudy skies. Data was collected from 10:00 am to 16:00 pm every 2 minute and the average was calculated for every 30 minute of the data collection to obtain the system efficiency. The results indicated that the DBLP system efficiency was evaluated as 11.67%. The DBLP system indoor illumination energy reduction was predicted as 0.822 kWh/day. This could replace 4 sets of a 32W fluorescent lamp operating 6.4 hours per a day.

Study of the frame in Underground Parking Spaces - Centering on the Improvement of Skylight on Daylighting Performance - (지하주차장 공간디자인에 관한 연구 - 채광성능 개선을 중심으로 -)

  • 황민구
    • Proceedings of the Korea Contents Association Conference
    • /
    • 2004.05a
    • /
    • pp.461-466
    • /
    • 2004
  • Recently, the underground parking spaces in apartments have been constructed owing to lack of parking spaces in spite of their various environmental problems derived from the fact they are under ground. This study describes the daylighting performance evaluation of underground parking spaces throughout a set of scale model measurement. As a result, in the design of top light system, uncovered open ratio of 4% should be recommended to provide sufficient amount of natural light for the standard light level.

  • PDF