• Title/Summary/Keyword: Day and night

Search Result 1,172, Processing Time 0.037 seconds

The Effects of Modafinil on Clinical Features and Sleep Structure of Narcolepsy Patients and Healthy Controls (모다피닐이 기면병 환자와 대조군의 임상 양상과 수면구조에 구조에 미치는 영향)

  • Shin, Hong-Beom;Jeong, Do-Un;Kim, Eui-Joong
    • Sleep Medicine and Psychophysiology
    • /
    • v.13 no.2
    • /
    • pp.67-74
    • /
    • 2006
  • Introduction: Excessive daytime sleepiness and cataplexy are key features of narcolepsy. Modafinil is psychostimulant used in the treatment of narcolepsy. In this study, we evaluated effects of modafinil on nocturnal sleep structure and sleep latency in multiple sleep latency test and clinical features. Methods: Twelve narcoleptic patients (7 male, age: $22.9{\pm}2.6\;yrs$) were participated in the study. All of them had done nocturnal polysomnography (nPSG), multiple sleep latency test (MSLT), clinical symptoms scales and have repeated same procedure after taking 200 mg of modafinil. We have done linear mixed model analysis to describe effects of group, medication and nap time on these measures. Results: Modafinil did not affect clinical scales except PSQI which had been reduced after medication. In this study, Modafinil reduced total sleep time, sleep efficiency and increased wake after sleep onset and percent of arousal during sleep in nocturnal polysomnography and prolonged mean sleep latency in multiple sleep latency tests in both group. Discussion: Modafinil has stimulant effect of central nervous system but its effect on night sleep is less than other psychostimulants such as methylphenidate. We ascertained that modafinil affected total sleep time, sleep efficiency and percent of wake during sleep but did not effect on sleep structure. Modafinil was effective in the management of day time sleepiness. Modafinil can enhance alertness of control group without day time sleepiness.

  • PDF

Properties of Hot Weather Nuclear Power Plant Concrete with Water Cooling Method and Retarding used (배합수 냉각방법 및 지연제 사용에 따른 서중 원전콘크리트의 특성)

  • Lee, Seung-Han;Jung, Yong-Wook;Jang, Seok-Soo;Yeo, In-Dong;Choi, Jong-Oh
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.14 no.9
    • /
    • pp.4602-4609
    • /
    • 2013
  • In summer and winter, the difference between the temperature during the day and that during the night is high, which leads to various problems during concrete placement, such as cracks and defects in the concrete as well as low durability and strength. Although nuclear power plant concrete is widely used for placement in all seasons, particular attention must be paid to its quality during the summer. Therefore, we evaluated the effects of a cooling method for mixing water, which is a commonly used hot weather precooling method, and the use of a retarder, on the characteristics of Nuclear Power Plant concrete. In the cooling method for mixing water, cold water at 5 was used, with 50% of the water content consisting of ice flakes. The effects of using a retarder were evaluated by reviewing the characteristics of the cement at the unset stage and after hardening. To evaluate the characteristics of the unset cement, we measured the slump, air volumes, setting times, and pressure strengths after hardening. Furthermore, we measured the heat of hydration at different temperatures; the loss of heat was minimized using insulation. Both the slump time and the complete ageing time of the air volume were found to be 120 min at $20^{\circ}C$ and 40 min at $40^{\circ}C$. In the case when the cooling method for mixing water was used and in the case when a retarder was used, the initial and final sets by penetration resistance were delayed, and the delay decreased with increasing air temperature. For the heat of hydration, the cooling method for mixing water not only lowered the maximum temperature but also delayed its attainment. However, the use of a retarder had no effect on the maximum temperature. Moreover, in the early ages (e.g., 3 and 7 days), the pressure strength of the concrete was lower than that of plain cement. However, the strength of 28-day concrete met the standard construction specifications.

Anti-stress effects of Herbal Acupuncture by Soyo-san on ovariectomized rats (소요산(逍遙散) 약침(藥鍼)이 난소적출 흰쥐의 항(抗)스트레스 작용(作用)에 미치는 영향(影響))

  • Oh, Seung-hee;Park, Hyun-jung;Hahm, Dae-hyun;Shim, In-sop;Lee, Hye-jung
    • Journal of Acupuncture Research
    • /
    • v.22 no.1
    • /
    • pp.117-130
    • /
    • 2005
  • Objective : Generation after generation, by Oriental medicine literatures, Soyo-san has been used as a clinical prescription that is important to climacteric syndrome, and also has been used extensively to psyco-neurotic problems, melancholia and stress symptoms. The experimental study of Soyo-san's effect has been reported, but the effect of herbal acupuncture solution by Soyo-san is not reported yet. Thus the purpose of this experiment is to test whether Herbal acupuncture of Soyo-san have anti-stress or antidepressant effects in the menopause or not. Methods : Female Sprague-Dawley(240-260g) rats were used. Temperature controlled within $20-25^{\circ}C$. Water and food not limited, and Manipulated the day and night 12 hours each. In the experiment, enforced Morris water maze after immobilization stress for 5 minutes, and operating Herbal acupuncture of Soyo-san 30 minutes before stress every day during 7 days. Flowed through by 4% paraformaldehyde and fixed brain tissue after test of 7 days. Results : 1) As a result of the acquisition test, Soyo-san group was recognized by significant difference compared to Ovx group and the retention test Soyo-san group increased significantly compared to Sham and Ovx group. 2) Soyo-san group showed that the degree of revealation of Tyrosine hydroxylase decreased comparing to Ovx group in ventral tegmental area and that of Choline acetyltransferase increased comparing to Ovx group in CAI region of Hippocampus. Conclusion : As a result of this experiment to grasp those effects on postmenopausal depression or learing disability and memory disorder, the possibility of Herbal acupunture by Soyo-san is warranted as a suitable treatment to relieve women's monopausal depression and those of stress reaction, improving tearing disability and memory disorder.

  • PDF

Effect on Digestion Efficiency by Adding Microbial Agent in Mesophilic Two-stage Anaerobic Digester (중온2단혐기성소화조에 미생물제재 주입시 소화효율에 미치는 영향)

  • Jung, Byung-Gil;Kim, Seok-Soon;Kang, Dong-Hyo;Sung, Nak-Chang;Choi, Seung-Ho;Lee, Hee-Pom
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.11 no.3
    • /
    • pp.75-86
    • /
    • 2003
  • In the near future, the capacity of conventional anaerobic digester is thought to be insufficient because of the increase of the total solids from expansion of intercepting sewer, sewage quantity and direct input of night soil from near apartment districts. The objectives of this study was to investigate the improvement of digestion efficiency using microbial agent(Bio-dh). The system was a pilot-scale, two-staged, anaerobic sludge digestion system. The first-stage digester was heated and mixed. The agitation velocity of the first-stage digester was 120rpm. The second-stage digester was neither heated nor mixed. The Digestion temperature was kept at $35{\pm}1^{\circ}C$ The detention time of digester was 19 days. The dosage of sewage sludge and microbial agent were $0.65m^3/day$ and $0.5{\ell}/day$, respectively. The experiments was run for 25days. Three times a week, $COD_{Mn}$ and SS of effluent, TS, VS, and biogas production rate were measured. Temperature, pH, and alkalinity were measured daily. The results were as follows ; Without microbial agent, digestion efficiencies ranged 46.0%~50.9%(mean=48.6%), with microbial agent(Bio-dh), digestion efficiencies ranged 52.8%~57.3%(mean=54.2%). Consequently, microbial agent(Bio-dh) increased the sludge digestion efficiency about 12%. Also, Without microbial agent, the mean concentration of $COD_{Mn}$ and SS of second-stage digester effluent were 1,639mg/L, 4,888mg/L respectively. With microbial agent, the mean concentration of $COD_{Mn}$ and SS of second-stage digester effluent were 859mg/L, 2,405mg/L respectively. Consequently, microbial agent(Bio-dh) increased the removal efficiency of $COD_{Mn}$ and SS about 47.6% and 50.8%, respectively.

  • PDF

A Study on Patterns of Sap Water Users of Acer mono (고로쇠나무 수액(樹液) 이용객(利用客)의 음용형태(飮用形態)에 관(關)한 연구(硏究))

  • An, Jong Man;Kim, Jun Sun;Kang, Hag Mo
    • Journal of Korean Society of Forest Science
    • /
    • v.87 no.4
    • /
    • pp.510-518
    • /
    • 1998
  • This study was carried out to investigate the drinking patterns of sap water of Acer mono by on-the-spot visitors. The survey was done from late-February to mid-March in the 3 major sap water tapping regions, such as Piagol of Mt. Chiri in Kurey, Okryong of Mt. Baekun in Kwangyang, and Mt. Chokey in Sunchon, Chonnam. A total of 300 visitors over 20 years old, 100 visitors in each region, were interviewed personally to make up questionnaires, irrespective of sex. The purpose of drinking, the frequency of visit, the modes of traffic, the length of stay, drinking amount per person, one's opinions after drinking, drinking plans and patterns, and intention of drinking processed sap were investigated and examined. Wide range of age groups from twenties to sixties drank sap water. Visitors drank sap water in order to keep health, to promote mutual friendship, and so on. 44% of sap drinkers visited for the first time, and 71% visited by private automobiles holding the first place. 59.7% of visitors spent only a day, but 40.3% passed one or two nights to drink sap water. For drinking amount of sap water, $3-6{\ell}$ a was consumed by 31.3% of visitors, under $3{\ell}$ or $9-12{\ell}$ by 22.7% $6-9{\ell}$ by 12.7% and so forth. 74% of visitors felt sap water sweet and favorable, but were doubtful about the efficacy of sap water. 79.0% of visitors had a plan to drink sap water again next year, 40% of whom preferred a day's visit to overnight staying (29%) or 3 days' staying (6%). 45% answered to plan to drink sap water with having meals, and 43% with having meals and passing a night. More than half (54.3%) of the visitors were inclined not to drink processed sap water for the reasons of unreliable quality, unwillingness for process, change in quality, etc.

  • PDF

Analytical Psychology-Based Interpretation of a Russian Fairy Tale Entitled "Seven Stars" (러시아 민담 '일곱 개의 별'에 대한 분석심리학적 해석)

  • Myeong-Sook Hwang
    • Sim-seong Yeon-gu
    • /
    • v.30 no.1
    • /
    • pp.31-66
    • /
    • 2015
  • A study on a Russian fairy tale entitled "Seven Stars" was conducted from the perspective of analytical psychology. The plot goes as follows. Once upon a time, a village in Russia was suffering from severe drought. Villagers were dying of thirst, and crops were withering day by day. One night, a little girl left their house carrying a wooden dipper to find water for her sick mother by herself. However, water was nowhere to be found. She felt tired and fell asleep. When she woke up, the moon was already over her head, and the dipper had been filled with water. On her way home to give the water to her mother, she found a dog lying on the ground. The dog was also dying of excessive thirst, so she gave the dog a handful of water. Then the wooden dipper suddenly turned into a silver dipper. When she had finally arrived home and her mother has drunk the water, the silver dipper changed into a golden dipper. At that moment, an old man showed up and asked for water. The little girl gave him water. When the old man stared at the water, she realized that there were seven diamonds twinkling like stars in the dipper. The water never ran out. Surprisingly enough, the seven diamonds suddenly soared up into the sky and eventually formed a constellation of the Big Dipper. The water was shared with the other villagers who, then, recovered their strength. The severe drought came to an end, and the villagers danced together with joy. In this fairy tale, the severe drought symbolizes devastation caused by a unidirectional stream of consciousness while the little girl represents a new function, which shows the value of women who can heal and restore from that devastation. Symbolized in a fairy tale character such as 'a daughter' or 'a little girl', the new function eventually reaches up to the value which leads and affects the group as well as individuals. To conclude, this new function represents the unconscious process whose role is to revitalize the maternity and resolve the problems posed to a group as well as individuals.

Critical Temperature for Early Marginal Transplanting of Japonica Rice in Korea (우리나라 자포니카 벼 품종의 조기이앙 한계온도 분석)

  • Woonho Yang;Shingu Kang;Dae-Woo Lee;Mi-Jin Chae
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.68 no.4
    • /
    • pp.246-261
    • /
    • 2023
  • We investigated critical temperature for early marginal transplanting (CT-EMT) of the contemporary japonica rice varieties in Korea through the field, pot seedling tray, and the phytotron experiments during 2020 to 2023. The lowest mean temperature for 10 days from transplanting (MT-10DFT) that resulted in earlier heading date was 12.4℃ and the highest MT-10DFT that did not show the earlier heading date was 12.0℃ in the field study when the MT-10DFT varied by changing transplanting date. The lowest MT-10DFT that induced the increased biomass but not the earlier heading date was 11.6℃ and the highest MT-10DFT that showed neither the increased biomass nor the earlier heading date was 11.4℃. Compared to the 10-day later transplanting, the dates of the first root development, initiation of the chlorophyll recovery, and the first tiller development were earlier when the MT-10DFT was 9.1℃ or higher, 10.5℃ or higher, and 11.6℃ or higher, respectively, in the pot seedling tray and field experiments. The earliness of the first tiller development was a practical index for the estimation of CT-EMT during the early growth stage of rice. The response of transplanted rice to temperature treatments with the diurnal change of 10℃ in the phytotron study was similar to that shown in the field study. The data shown for constant temperature without a diurnal change revealed that the extent of positive effects of high temperature at day-time was greater than the extent of negative effects of low temperature at night-time on the early growth of transplanted rice. It was concluded that the critical MT-10DFT for early marginal transplanting of japonica rice in the temperate environments was between 11.4 to 11.6℃ based on the plant growth and between 12.0 to 12.4℃ based on the plant development.

Study on the Estimation between CO2 Flux in Tree and Atmosphere (산림-대기 간 이산화탄소 교환량 산정 연구)

  • Kim, So Young;Park, Hyun Ju;Hong, You Deog;Han, Jin Seok;Son, Jung Seok;Park, Ji Hoon
    • Journal of Climate Change Research
    • /
    • v.4 no.4
    • /
    • pp.305-316
    • /
    • 2013
  • The purpose of this study is to monitor the flux of $CO_2$ between the atmosphere and forest. The main research activities are conducted at Taehwa Mt. (Gangju, Kyeonggi, Korea), The Taehwa site is located 60 km north-east from the center of Seoul Metropolitan Area. The TRF flux tower is in the middle of a Korean Pine (Pinus koraiensis) plantation ($400m{\times}400m$), surrounded by a mixed forest. Eddy covariance method was used for $CO_2$ flux above the forest. $CO_2$ flux was measured from September to November 2011 and March to June 2012. It was found that $CO_2$ fluxes were observed between the atmosphere and forest. $CO_2$ was absorbed by plants through photosynthesis during the day and released during the night. $CO_2$ flux were respectively observed 0.7~0.2, 0.5~0.1, $0.3{\sim}0.1mgCO_2m^{-2}s^{-1}$ in Septem- ber, October, November 2011. $CO_2$ fluxes released by plants in the early morning(00:00~07:30h) and evening(18:00~24:00h) time. But $CO_2$ was absorbed by plants through photosynthesis in the day time(08:00~7:30h).

Clinical Features of Acute Nonspecific Mesenteric Lymphadenitis and Factors for Differential Diagnosis with Acute Appendicitis (급성 비특이성 장간막 림프절염의 임상 소견과 급성 충수돌기염과의 감별 인자)

  • Shin, Kyung Hwa;Kim, Gab Cheol;Lee, Jung Kwon;Lee, Young Hwan;Kam, Sin;Hwang, Jin Bok
    • Pediatric Gastroenterology, Hepatology & Nutrition
    • /
    • v.7 no.1
    • /
    • pp.31-39
    • /
    • 2004
  • Purpose: Although acute nonspecific mesenteric lymphadenitis (ANML) is probably common cause of abdominal pain in children, which can be severe enough to be an abdominal emergency, the clinical features of mesenteric lymphadenitis are not clear. Also, a differential diagnosis with acute appendicitis (APPE) is indispensable to avoid serious complications. The clinical features of ANML were determined, and the risk factors for differential diagnosis with APPE were analyzed. Methods: Between November 2000 and May 2001, data from 26 patients (aged 1 to 11 years) with ANML and 21 patients (aged 2 to 13 years) with APPE were reviewed. ANML was defined as a cluster of five or more lymph nodes measuring 10 mm or greater in their longitudinal diameter in the right lower quadrant (RLQ) without an identifiable specific inflammatory process on the ultrasonographic examination. There were risk factors on patient's history, physical examination, and laboratory examination; the location of abdominal pain, abdominal rigidity, rebound tenderness, fever, nocturnal pain, the vomiting intensity, the diarrhea intensity, the symptom duration, and the peripheral blood leukocytes count. Results: Of the 26 ANML patients and 21 APPE patients, abdominal pain was noted on periumbilical (76.9% vs 14.2%), on RLQ (11.5% vs 71.4%), with abdomen rigidity (7.6% vs 80.9%), with rebound tenderness (0.0% vs 76.1%)(p<0.05), in the lower abdomen (11.5% vs 14.2%), and at night (80.8% vs 100.0%) (p>0.05). The clinical symptoms were vomiting (38.4% vs 90.4%), the vomiting intensity ($1.5{\pm}0.7$ [1~3]/day vs $4.5{\pm}2.9$ [1~10]/day), diarrhea (65.3% vs 28.5%) (p<0.05), and fever (61.5% vs 76.2%)(p>0.05). The period to the subsidence of abdominal pain in the ANMA patients was $2.5{\pm}0.5$ (2~3) days. The laboratory data showed a significant difference in the peripheral blood leukocytes count ($8,403{\pm}1,737[5,900{\sim}12,300]/mm^3\;vs\;15,471{\pm}3,749[5,400{\sim}20,800]/mm^3$)(p<0.05). Discriminant analysis between ANML and APPE showed that the independent discriminant factors were a vomiting intensity and the peripheral blood leukocytes count and the discriminant power was 95.7%. Conclusion: The clinical characteristics of ANML were abrupt onset of periumbilical pain without rigidity or rebound tenderness, a mild vomiting intensity, normal peripheral leukocytes count, and relatively short clinical course. If the abdominal pain persist for more than 3 days, and/or the vomiting intensity is more than 3 times/day, and/or the peripheral leukocytes count is over $13,500/mm^3$, abdominal ultrasonography is recommended to rule out APPE.

  • PDF

Analysis of Greenhouse Thermal Environment by Model Simulation (시뮬레이션 모형에 의한 온실의 열환경 분석)

  • 서원명;윤용철
    • Journal of Bio-Environment Control
    • /
    • v.5 no.2
    • /
    • pp.215-235
    • /
    • 1996
  • The thermal analysis by mathematical model simulation makes it possible to reasonably predict heating and/or cooling requirements of certain greenhouses located under various geographical and climatic environment. It is another advantages of model simulation technique to be able to make it possible to select appropriate heating system, to set up energy utilization strategy, to schedule seasonal crop pattern, as well as to determine new greenhouse ranges. In this study, the control pattern for greenhouse microclimate is categorized as cooling and heating. Dynamic model was adopted to simulate heating requirements and/or energy conservation effectiveness such as energy saving by night-time thermal curtain, estimation of Heating Degree-Hours(HDH), long time prediction of greenhouse thermal behavior, etc. On the other hand, the cooling effects of ventilation, shading, and pad ||||&|||| fan system were partly analyzed by static model. By the experimental work with small size model greenhouse of 1.2m$\times$2.4m, it was found that cooling the greenhouse by spraying cold water directly on greenhouse cover surface or by recirculating cold water through heat exchangers would be effective in greenhouse summer cooling. The mathematical model developed for greenhouse model simulation is highly applicable because it can reflects various climatic factors like temperature, humidity, beam and diffuse solar radiation, wind velocity, etc. This model was closely verified by various weather data obtained through long period greenhouse experiment. Most of the materials relating with greenhouse heating or cooling components were obtained from model greenhouse simulated mathematically by using typical year(1987) data of Jinju Gyeongnam. But some of the materials relating with greenhouse cooling was obtained by performing model experiments which include analyzing cooling effect of water sprayed directly on greenhouse roof surface. The results are summarized as follows : 1. The heating requirements of model greenhouse were highly related with the minimum temperature set for given greenhouse. The setting temperature at night-time is much more influential on heating energy requirement than that at day-time. Therefore It is highly recommended that night- time setting temperature should be carefully determined and controlled. 2. The HDH data obtained by conventional method were estimated on the basis of considerably long term average weather temperature together with the standard base temperature(usually 18.3$^{\circ}C$). This kind of data can merely be used as a relative comparison criteria about heating load, but is not applicable in the calculation of greenhouse heating requirements because of the limited consideration of climatic factors and inappropriate base temperature. By comparing the HDM data with the results of simulation, it is found that the heating system design by HDH data will probably overshoot the actual heating requirement. 3. The energy saving effect of night-time thermal curtain as well as estimated heating requirement is found to be sensitively related with weather condition: Thermal curtain adopted for simulation showed high effectiveness in energy saving which amounts to more than 50% of annual heating requirement. 4. The ventilation performances doting warm seasons are mainly influenced by air exchange rate even though there are some variations depending on greenhouse structural difference, weather and cropping conditions. For air exchanges above 1 volume per minute, the reduction rate of temperature rise on both types of considered greenhouse becomes modest with the additional increase of ventilation capacity. Therefore the desirable ventilation capacity is assumed to be 1 air change per minute, which is the recommended ventilation rate in common greenhouse. 5. In glass covered greenhouse with full production, under clear weather of 50% RH, and continuous 1 air change per minute, the temperature drop in 50% shaded greenhouse and pad & fan systemed greenhouse is 2.6$^{\circ}C$ and.6.1$^{\circ}C$ respectively. The temperature in control greenhouse under continuous air change at this time was 36.6$^{\circ}C$ which was 5.3$^{\circ}C$ above ambient temperature. As a result the greenhouse temperature can be maintained 3$^{\circ}C$ below ambient temperature. But when RH is 80%, it was impossible to drop greenhouse temperature below ambient temperature because possible temperature reduction by pad ||||&|||| fan system at this time is not more than 2.4$^{\circ}C$. 6. During 3 months of hot summer season if the greenhouse is assumed to be cooled only when greenhouse temperature rise above 27$^{\circ}C$, the relationship between RH of ambient air and greenhouse temperature drop($\Delta$T) was formulated as follows : $\Delta$T= -0.077RH+7.7 7. Time dependent cooling effects performed by operation of each or combination of ventilation, 50% shading, pad & fan of 80% efficiency, were continuously predicted for one typical summer day long. When the greenhouse was cooled only by 1 air change per minute, greenhouse air temperature was 5$^{\circ}C$ above outdoor temperature. Either method alone can not drop greenhouse air temperature below outdoor temperature even under the fully cropped situations. But when both systems were operated together, greenhouse air temperature can be controlled to about 2.0-2.3$^{\circ}C$ below ambient temperature. 8. When the cool water of 6.5-8.5$^{\circ}C$ was sprayed on greenhouse roof surface with the water flow rate of 1.3 liter/min per unit greenhouse floor area, greenhouse air temperature could be dropped down to 16.5-18.$0^{\circ}C$, whlch is about 1$0^{\circ}C$ below the ambient temperature of 26.5-28.$0^{\circ}C$ at that time. The most important thing in cooling greenhouse air effectively with water spray may be obtaining plenty of cool water source like ground water itself or cold water produced by heat-pump. Future work is focused on not only analyzing the feasibility of heat pump operation but also finding the relationships between greenhouse air temperature(T$_{g}$ ), spraying water temperature(T$_{w}$ ), water flow rate(Q), and ambient temperature(T$_{o}$).

  • PDF