• Title/Summary/Keyword: Data transmission algorithm

Search Result 1,122, Processing Time 0.026 seconds

Design and Analysis of a Transmission Rate Control Algorithm for Client's Buffer on VOD Systems (VOD 시스템에서 클라이언트 버퍼를 위한 전송율 제어 알고리즘의 설계 및 분석)

  • 김완규;박규석
    • Journal of Korea Multimedia Society
    • /
    • v.1 no.1
    • /
    • pp.67-79
    • /
    • 1998
  • In this paper, we present the design and analyze the transmission rate of a control algorithm for the client buffer on the VOD systems. The design is based on the server's data transmission rate and clients' data consumption rate. The proposed algorithm stabilizes the client's buffer by reducing the oscillation phenomena of the buffer. And it uses the BCT (Buffer Check Time) to reduce the scheduling load of the client system. The client's data consumption rate and the buffer size are calculated on the basis of BCT. In case that the predicted buffer size operates in the overrun or starvation the buffer. As the load fluctuation of the network, the transmission rate control policy cannot stabilize the client's buffer alone. The media scaling policy, therefore, also performs its complementary part in stabilizing the client's buffer, and performance evaluation of the proposed algorithm is provided through simulation.

  • PDF

A Fault Location Algorithm Using Adaptively Estimated Local Source Impedance for a Double-Circuit Transmission Line System (자기단 전원 임피던스 추정 기법을 사용한 병행 2회선 송전선로 고장점 표정 알고리즘)

  • Park, Gun-Ho;Kang, Sang-Hee;Kim, Sok-Il;Shin, Jonathan H.
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.61 no.3
    • /
    • pp.373-379
    • /
    • 2012
  • This paper presents a fault location algorithm based on the adaptively estimated value of the local sequence source impedance for faults on a parallel transmission line. This algorithm uses only the local voltage and current signals of a faulted circuit. The remote current signals and the zero-sequence current of the healthy adjacent circuit are calculated by using the current distribution factors together with the local terminal currents of the faulted circuit. The current distribution factors consist of local equivalent source impedance and the others such as fault distance, line impedance and remote equivalent source impedance. It means that the values of the current distribution factors can change according to the operation condition of a power system. Consequently, the accuracy of the fault location algorithm is affected by the two values of equivalent source impedances, one is local source impedance and the other is remote source impedance. Nevertheless, only the local equivalent impedance can be estimated in this paper. A series of test results using EMTP simulation data show the effectiveness of the proposed algorithm. The proposed algorithm is valid for a double-circuit transmission line system where the equivalent source impedance changes continuously.

Layer based Cooperative Relaying Algorithm for Scalable Video Transmission over Wireless Video Sensor Networks (무선 비디오 센서 네트워크에서 스케일러블 비디오 전송을 위한 계층 기반 협업 중계 알고리즘*)

  • Ha, Hojin
    • Journal of Korea Society of Digital Industry and Information Management
    • /
    • v.18 no.4
    • /
    • pp.13-21
    • /
    • 2022
  • Recently, in wireless video sensor networks(WVSN), various schemes for efficient video data transmission have been studied. In this paper, a layer based cooperative relaying(LCR) algorithm is proposed for minimizing scalable video transmission distortion from packet loss in WVSN. The proposed LCR algorithm consists of two modules. In the first step, a parameter based error propagation metric is proposed to predict the effect of each scalable layer on video quality degradation at low complexity. In the second step, a layer-based cooperative relay algorithm is proposed to minimize distortion due to packet loss using the proposed error propagation metric and channel information of the video sensor node and relay node. In the experiment, the proposed algorithm showed that the improvement of peak signal-to-noise ratio (PSNR) in various channel environments, compared to the previous algorithm(Energy based Cooperative Relaying, ECR) without considering the metric of error propagation.The proposed LCR algorithm minimizes video quality degradation from packet loss using both the channel information of relaying node and the amount of layer based error propagation in scalable video.

Hybrid MAC Protocol for Improving Performance of IEEE 802.11 Wireless LANs (IEEE 802.11 무선랜의 성능 향상을 위한 하이브리드 MAC 프로토콜)

  • Choi, Woo-Yong
    • Journal of Korean Institute of Industrial Engineers
    • /
    • v.41 no.2
    • /
    • pp.220-224
    • /
    • 2015
  • The DCF (Dcistributed Coordination Function) and PCF (Point Coordination Function) are the basic MAC (Medium Access Control) protocols of IEEE 802.11 wireless LANs. According to the DCF, each node performs the exponential backoff algorithm before the transmission of its data frame. Each node doubles the backoff waiting time before the transmission of its data frame whenever it detects the transmission collision with other nodes. Therefore, as the number of the active nodes having the data frames to transmit increases, the overall MAC performance of the DCF decreases. On the other hand, according to the PCF, each node is granted the transmission opportunity by which the PCF transmission is possible without the collision with other nodes. Therefore, as the number of the active nodes increases, the MAC performance of the PCF increases, In this paper, considering the tradeoff of MAC performance between the DCF and PCF, a hybrid MAC protocol is proposed to enhance the performance of IEEE 802.11 wireless LANs.

The Improvement of the Data Overlapping Phenomenon with Memory Accessing Mode

  • Yang, Jin-Wook;Woo, Doo-Hyung;Kim, Dong-Hwan;Yi, Jun-Sin
    • Journal of Information Display
    • /
    • v.9 no.1
    • /
    • pp.6-13
    • /
    • 2008
  • Mobile phones use the embedded memory in LDI (LCD Driver IC). In memory accessing mode, data overlapping phenomenon can occur. These days, various contents such as DMB, Camera, Game are merged to phone. Accordingly, with more data transmission, there would be more data overlapping phenomenon in memory accessing mode. Human eyes perceive this data overlapping phenomenon as simply horizontal line noise. The cause of the data overlapping phenomenon was analysed in this paper. The data overlapping phenomenon can be changed by the speed of data transmission between the host and LDI. The optimum memory accessing position can be defined. This paper proposes a new algorithm for avoiding data overlapping.

Cross-layer based Transmission Scheme for Multimedia Service over Mobile Ad Hoc Network (이동 애드 혹 네트워크상에서 멀티미디어 서비스를 위한 크로스레이어 기반의 전송 기법)

  • An, Ki-Jin;Joo, Hyun-Chul;Song, Hwang-Jun
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.34 no.11B
    • /
    • pp.1216-1224
    • /
    • 2009
  • This paper presents cross-layer based packet scheduling and routing algorithm to effectively transmit delay-sensitive multimedia data over mobile ad hoc network. At first, packet urgency, node urgency, and route urgency are defined based on the end-to-end delay requirement of each packet and the number of hops over a route. Based on the urgency metric, the proposed transmission scheme is that packet scheduling algorithm at the MAC layer and routing algorithm at the network layer are tightly-coupled to improve the transmission performance for delay-sensitive multimedia. Finally, simulation results are provided to show the performance of proposed transmission scheme.

Development of an Extended EDS(Earliest Deadline Scheduling) Algorithm for the CAN-Based Real-Time System (CAN기반 실시간 시스템을 위한 확장된 EDS 알고리즘 개발)

  • Lee, Byong-Hoon;Kim, Hong-Ryeol;Kim , Dae-Won
    • The Transactions of the Korean Institute of Electrical Engineers D
    • /
    • v.51 no.7
    • /
    • pp.294-301
    • /
    • 2002
  • A new dynamic scheduling algorithm is proposed for CAN-based real-time system in this paper. The proposed algorithm is extended from an existing EDS(Earliest Deadline Scheduling) approach having a solution to the priority inversion. Using the proposed algorithm, the available bandwidth of network media can be checked dynamically, and consequently arbitration delay causing the miss of deadline can be avoided. Also, non-real time messages can be processed with their bandwidth allocation. Full network utilization and real-time transmission feasibility can be achieved through the algorithm. To evaluate the performance of algorithm, two simulation tests are performed. The first one is transmission data measurement per minute for periodic messages and the second one is feasibility in the system with both periodic messages and non-real time message.

Fault Location Algorithm with Ground Capacitance Compensation for Long Parallel Transmission Line (장거리 병렬 송전선로용 대지 정전용량 보상에 의한 고장점 표정 알고리즘)

  • Park, Chul-Won;Kim, Sam-Ryong;Shin, Myong-Chul
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.54 no.4
    • /
    • pp.163-170
    • /
    • 2005
  • This paper deals with an improved fault location algorithm with compensation ground capacitance through distributed parameter for a long parallel T/L. For the purpose of fault locating algorithm non-influenced by source impedance and fault resistance, the loop method was used in the system modeling analysis. This algorithm uses a positive and negative sequence of the fault current for high accuracy of fault locating calculation. Power system model of 160km and 300km long parallel T/L was simulated using EMTP software. To evaluate of the proposed algorithm, we used the several different cases 64 sampled data per cycle. The test results show that the proposed algorithm was minimized the error factor and speed of fault location estimation.

A Numerical Algorithm for Fault Location Estimation Considering Long-Transmission Line (장거리 송전선로를 고려한 사고거리추정 수치해석 알고리즘)

  • Kim, Byeong-Man;Chae, Myeong-Suk;Kang, Yong-Cheol
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.57 no.12
    • /
    • pp.2139-2146
    • /
    • 2008
  • This paper presents a numerical algorithm for fault location estimation which used to data from both end of the transmission line. The proposed algorithm is also based on the synchronized voltage and current phasor measured from the PMUs(Phasor Measurement Units) in the time-domain. This paper has separated from two part of with/without shunt capacitance(short/long distance). Most fault was arc one-ground fault which is 75% over [1]. so most study focused with it. In this paper, the numerical algorithm has calculated to distance for ground fault and line-line fault. In this paper, the algorithm is given with/without shunt capacitance using II parameter line model, simple impedance model and estimated using DFT(Discrete Fourier Transform) and the LES(Least Error Squares Method). To verify the validity of the proposed algorithm, the EMTP(Electro- Magnetic Transient Program) and MATLAB did used.

Transmission Line Fault Location Algorithm Using Estimated Local Source Impedance (자기단 전원임피던스 추정을 이용한 송전선 고장점표정 알고리즘)

  • Kwon, Young-Jin;Kim, Su-Hwan;Kang, Sang-Hee
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.58 no.5
    • /
    • pp.885-890
    • /
    • 2009
  • A fault location algorithm using estimated local source impedance after a fault is proposed in this paper. The method uses after fault data only at the local end. It uses the negative sequence current distribution factor for more accurate estimation. The proposed algorithm can keep up with the variation of the local source impedance. Therefore, the proposed algorithm especially is valid for a transmission line interconnected to a wind farm that the equivalent source impedance changes continuously. The performance of the proposed algorithm was verified under various fault conditions using the Simpowersystem of MATLAB Simulink. The proposed algorithm is largely insensitive to the variation in fault distance and fault resistance. The test results show a very high accurate performance.