• Title/Summary/Keyword: Data leak

Search Result 256, Processing Time 0.021 seconds

The Recovery of Heavy Metals Using Encapsulated Microbial Cells

  • Park, Joong-Kon;Jin, Yong-Biao;Park, Hyung-Woo
    • Biotechnology and Bioprocess Engineering:BBE
    • /
    • v.2 no.2
    • /
    • pp.132-135
    • /
    • 1997
  • We prepared capsules containing Saccharomyces cerevisiae and Zoogloea ramigera cells for the removal of lead(II) and cadmium ions. Microbial cells were encapsulated and cultured in the growth medium. The S.cerevisiae cells grown in the capule did not leak through the capsule membrane. The dried cell density reached to 250 g/l on the basis of the inner volume of the 2.0 mm diameter capsule after 36 hour cultivation. The dry whole cell expolymer density of encapsulated Z.ramigera reached to 200 g/L. The capsule was crosslinked with triethylene tetramine and glutaric dialdehyde solutions. The cadmium uptake of encapsulated whole cell expolymer of Z.ramigera was 55mg Cd/g biosorbent. The adsorption line followed well Langmuir isotherm. The lead uptake of the encapsulated S. cerevisiae was about 30 mg Pb/g biomass. The optimum pH of the lead uptake using encapsulated S. cerevisiae was found to be 6. Freundlich model showed a little better fit to the adsorption data than Langmuir model 95 percent of the lead adsorbed on the encapsulated biosorbents was desorbed by the 1 M HCl solution. The capsule was reused 50 batches without loosing the metal uptake capacity. And the mechanical strength of the crosslinked capsule was retained after 50 trials.

  • PDF

An Experimental Study on the Pumping Performance of the Multi-stage Disk-type Drag Pump (다단 원판형 드래그펌프의 배기 성능에 관한 실험적 연구)

  • 권명근;허중식;황영규
    • Journal of the Korean Vacuum Society
    • /
    • v.12 no.2
    • /
    • pp.79-85
    • /
    • 2003
  • Experimental investigations are performed for the rarefied gas flows in a multi-stage disk-type drag pump. The pump considered in the present study consists of grooved rotors and stators. The flow-meter method is adopted to calculate the pumping speed. Compression ratios and pumping speeds for the nitrogen gas are measured under the outlet pressure range of 0.13∼533 Pa. The present experimental data show the leak-limited value of the compression ratio in the molecular transition region. The rotational speed of the pump is 24,000rpm, and nitrogen is used as a test gas. The pumping characteristics of various drag pumps are performed. The inlet pressures are measured for various outlet pressures of the test pump. The ultimate pressures for zero throughput are measured for three-stage, two-stage and single-stage disk-type, respectively.

An Adaptive Network Double Buffer Model for Efficient Memory Resource Usage (메모리 자원 사용 효율성 증진을 위한 적응적 네트워크 이중 버퍼 모델)

  • Choi, Daniel;Lee, Sung-Young
    • Journal of KIISE:Computer Systems and Theory
    • /
    • v.33 no.11
    • /
    • pp.810-819
    • /
    • 2006
  • This paper proposes an Adaptive Double Buffer Model. As a new FIFO buffer model, this technique minimizes packet losses from network congestion by logically managing buffers. It allocates the spare spaces of non-congested buffers to congested buffers by allowing receive/send buffers to share two queues, and hence it minimizes packet losses. In contrast to the buffer model utilizing a free list, this buffer model can prevent the bubble phenomenon caused by a memory leak and thereby apply to a network buffer in a restricted environment. Also, compared with the model using an way, this model brings maximum 100 percent improvement in accepting packets and compared with the model utilizing a free list, this model has the similar efficiency Results of the performance test on Adaptive Double Buffer Model, shows that this proposed model decreases packet losses and enhances memory efficiency.

A study on importance of MSDS education (MSDS 교육의 중요성에 관한 연구)

  • Choi, Sung-Jai
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.15 no.6
    • /
    • pp.209-215
    • /
    • 2015
  • Following the semiconductor industry's growing, various types of toxic gases and caustic chemicals, HF(Hydrofluoric acid), HCI (Hydochloric acid), $H_2O_2$ (Hydrogen peroxide), $H_2SO_4$ (Sulfuric acid), and Piranha, were using on the semiconductor manufacturing process. Therefore many gas leakage accidents that produce huge losses of lives were caused by the processes. This research deeply considers two basic solutions that the necessity of MSDS education on university for reducing damage of lives and protecting life from chemical leak accidents such as a HF accident in Gumi, Korea and the use of GHS, REACH and the comprehension of propriety about using MSDS for keeping safety from conflagrations by released poison chemical materials.

Development of a Magnetic Seal and the Leak Test (마그네틱씰 개발 및 기밀 평가 시험)

  • Kim, Ock-Hyun;Lee, Min-Ki
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.10 no.2
    • /
    • pp.79-83
    • /
    • 2011
  • Magnetic seal uses a magnetic fluid to seal a gap between a rotating shaft and housing. It is distinguished from other kinds of seals from the fact that solid contact does not occur in the seal. This implies that it is free from solid rubbing thus dustless and provides a clean circumstance. That is the reason why the magnetic seal is used exclusively for most of vacuum chambers in semiconductor process where dustless clean circumstance is critical. A magnetic seal has been developed of which design parameters are determined based on published data, and an air pressure test has been done to examine its sealing capability. Effects of some design parameters have been studied through FEM analysis. The results show some notable aspects of design parameters and provide suggestions for developing the seals. Regarding the sealing capacity of the magnetic seal the factor to match the theoretical value with the actual one was found to be 0.4~0.7, which means still there is some discrepancy between theory and actual.

A Study on the Fatigue Reliability of Structures by Markov Chain Model (Markov Chain Model을 이용한 구조물의 피로 신뢰성 해석에 관한 연구)

  • Y.S. Yang;J.H. Yoon
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.28 no.2
    • /
    • pp.228-240
    • /
    • 1991
  • Many experimental data of fatigue crack propagation show that the fatigue crack propagation process is stochastic. Therefore, the study on the crack propagation must be based on the probabilistic approach. In the present paper, fatigue crack propagation process is assumed to be a discrete Markov process and the method is developed, which can evaluate the reliability of the structural component by using Markov chain model(Unit step B-model) suggested by Bogdanoff. In this method, leak failure, plastic collapse and brittle fracture of the critical component are taken as failure modes, and the effects of initial crack distribution, periodic and non-periodic inspection on the probability of failure are considered. In this method, an equivalent load value for random loading such as wave load is used to facilitate the analysis. Finally some calculations are carried out in order to show the usefulness and the applicability of this method. And then some remarks on this method are mentioned.

  • PDF

Design and Implementation of Information Security System to Prevent Leakage of Drawing Information (설계정보 유출방지를 위한 정보보안시스템 설계 및 구현)

  • Chang, H.B.;Lee, H.S.
    • Korean Journal of Computational Design and Engineering
    • /
    • v.11 no.5
    • /
    • pp.327-334
    • /
    • 2006
  • Recently, security incidents are growing rapidly in which internal employees let the drawing leak out to competitors or other countries. This type of security incidents has a characteristic that it occurs less frequently than other types of security incidents such as network or server security incident, but the damage is a lot more serious. The existing information security technologies to prevent internal information from being leaked out are only applicable to general documents(office documents, web pages and image files in which data are encrypted one by one). However, architectural drawings made up of collection of files with various formats(extensions) have problems with the process speed of en(de) cryption and accuracy, so the developments of security technologies by new methods are required. In this study, we design and develop a security technology based on work area with which users can protect the leakage of critical information in the kernel level while maintaining their work environment when they have to use sharing information that cannot be managed by the unit of file. As a result, we developed the "Virtual Secure Disk" which allows only authorized users and applications to have an access to drawings, and have verified its security by applying it to the actual company.

Proposal on the Standard Water Leakage Diagnosis Manual of Leakage Type in Underground Structures Housing -Focused on Maintenance Plan - (공동주택 지하구조물 표준 누수 진단 매뉴얼 제안 - 유지관리 계획을 중심으로 -)

  • Kim, Soo Yeon;Lee, Jung Hun;Song, Je Young;Jang, Duk Bae;Oh, Sang Keun
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2017.11a
    • /
    • pp.221-222
    • /
    • 2017
  • An analysis of the current water leak status of understand structure (underground parking lots, staircases, plumbing systems, water reservoirs, etc.) of multi-family housing in South Korea shows that water leaks are found from cracks in all areas of the underground structure caused by the degradation environment (water pressure by underground water, humidity, temperature, earth pressure, soil behaviour and vibration, etc.), which result in various problems, including mold, malodour, debonding of finishing materials, exfoliation, breakout, water leaks in electrical boxes, efflorescence, sedimentation of calcium hydroxide, decoloration, rusting, damages and pollution among others. Therefore, this study aims to analyse the current status of water leaks in underground structure and use the results as the basic data for developing a standard guideline for water leaks and maintenance by parts of the underground structure of multi-family housing.

  • PDF

Analysis on the Vulnerability of Information Leakage through Electromagnetic Emanations from PC Keyboard (키보드 누설 방사에 의한 정보 누설 취약성 분석)

  • Lee, Dae-Heon;Hwang, In-Ho
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.18 no.1 s.116
    • /
    • pp.76-81
    • /
    • 2007
  • In this paper, we analyzed the vulnerability of information leakage due to the leakage electromagnetic waves of a PC keyboard. First, we reviewed the keyboard protocol and hardware structure, we analyzed the correlation between the data signal, which is transmitted from the keyboard to the main body, and the leakage signal on the power cable. With the result, we grasped the cause of the Conducted Emission of a PC keyboard. Also, we compared the limit level of the CISPR 22 standard with the amplitude of the keyboard leakage electromagnetic waves we calculated. By analyzing the signal on the power cable of the PC main body through the simple experiment, we show that it is possible to extract the contents of the PC key. Therefore it is verified that the secret information of the PC user could leak out.

Safety Monitoring Sensor for Underground Subsidence Risk Assessment Surrounding Water Pipeline (상수도관로의 주변 지반침하 위험도 평가를 위한 안전감시 센서)

  • Kwak, Pill-Jae;Park, Sang-Hyuk;Choi, Chang-Ho;Lee, Hyun-Dong
    • Journal of Sensor Science and Technology
    • /
    • v.24 no.5
    • /
    • pp.306-310
    • /
    • 2015
  • IoT(Internet of Things) based underground risk assessment system surrounding water pipeline enables an advanced monitoring and prediction for unexpected underground hazards such as abrupt road-side subsidence and urban sinkholes due to a leak in water pipeline. For the development of successful assessment technology, the PSU(Water Pipeline Safety Unit) which detects the leakage and movement of water pipes. Then, the IoT-based underground risk assessment system surrounding water pipeline will be proposed. The system consists of early detection tools for underground events and correspondence services, by analyzing leakage and movement data collected from PSU. These methods must be continuous and reliable, and cover certain block area ranging a few kilometers, for properly applying to regional water supply changes.