• Title/Summary/Keyword: Data converter

검색결과 623건 처리시간 0.036초

메디안 필터를 이용한 포맷 변환기 구현에 관한 연구 (A Study on the Implementation of Format Converter using Median Filter)

  • 김현기;하기종;최영규;류기한;이천희
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2003년도 하계종합학술대회 논문집 II
    • /
    • pp.1137-1140
    • /
    • 2003
  • The area of the prototype device is less than 80mm$^2$. Operating with a 60ns clock cycle, the device typically dissipates only 300mW. The full functionality was proven by using the methodical test programs based on typical image processing operations. Also, we realized the whole process from conventional gray image to color image. Format converters, implemented using multidimensional access memories, transfer the data between the processing element array and conventional bit-parallel components in real time. The completed system is fully functional and performs typical low-level image processing tasks at speed exceeding 30 frames of traditional TV system per second.

  • PDF

수중 초음파 통신을 위한 적응형 BPSK 복조기의 DSP 구현 (DSP Implementation of the Adaptive BPSK demodulator for Underwater acoustic communication)

  • 전재국;박찬섭;주형준;김기만
    • 한국마린엔지니어링학회:학술대회논문집
    • /
    • 한국마린엔지니어링학회 2006년도 전기학술대회논문집
    • /
    • pp.109-110
    • /
    • 2006
  • The performance of a digital baseband signal processing and data transmission rate depends on the modulation technique. In this paper, We implemented DSP communication system for Underwater acoustic communication using by adaptive BPSK modem technique. In order to implement adaptive modem, we suggested SNR detection block. SNR detection block has the reference SNR value that selects between window filter path and matched filter path. In this paper, suggested system is based on software interface and all Hardware(PLL, modem filter, equalizer etc) is implemented by software, exclusive of DSP, A/D, D/A converter, SDRAM and Flash memory.

  • PDF

유체커플링의 특성에 관한 실험적 연구

  • 박용호;박진건;김기홍;염만오
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 1992년도 추계학술대회 논문집
    • /
    • pp.204-208
    • /
    • 1992
  • The purpose of this research is to construct the experimental test set-ups and establish a series of performance test program for the domestically developed fluid couplings, and to provide a software to store and utilize these experimental data which can be used to improve the performance of the fluid coupling and solve on the job problems confronted in operation. The performance test consists of taking measurement of torque rpm and efficiency of the fluid coupling for three different amount of working fluid inside with various loads to the output shaft and finally investigating the torque rpm and efficiency characteristics of the fluid coupling with respect to these parameters. The results of this study can contribute valuable references tot the development of variable speed fluid coupling and torque converter currently pursued by the domestic industry.

우리나라, 유럽 및 미국의 식품용 용기포장재 기준규격 관리제도 연구 (Regulations of Food Packaging in Korea, Europe and USA)

  • 전대훈;이영자
    • 한국포장학회지
    • /
    • 제13권2호
    • /
    • pp.75-78
    • /
    • 2007
  • Regulation of food packaging in Korea, Eurpoe and USA are surveyed. Food packaging manufacturer or converter has a responsibility to evaluate the safety of migration of harmful materials from typical finished packaging items. The 'overall migration limit' of all components from the packaging and 'specific migration limits(SML)' of monomers or additives are evaluated with food simulants, water, acetic acid, ethanol and n-heptane, based on the regulations of the countries. A substance not regulated has to be authorized with the technical data required, information on chemical identity, physical chemical and other properties, the intended use, migration studies and toxicological studies.

  • PDF

어육신선도 측정장치의 개발 (Development of device for the degree of freshness of wet fish)

  • 유휘룡;이남걸;신민생;조영제;김상봉
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1992년도 한국자동제어학술회의논문집(국내학술편); KOEX, Seoul; 19-21 Oct. 1992
    • /
    • pp.272-275
    • /
    • 1992
  • Recently, the digital circuit technique has had great success and gained importance in all industries. For the measurement of degree of freshness of plant and animal's tissue, many devices has been developed. But it's data was inaccurate and it had difficulty in making database because it was depend on analog circuit technique. The purpose of this paper is the development of a device based on digital circuit for measurement of freshness degree of wet fish such that its accuracy is very trustworthy and it can be measured in a short time. The device is developed by using micro-computer with some interface modules of A-D/D-A converter and digital circuit with IC modules and its effectiveness has been evaluated through two experimental results of electrical Q-value test and chemical K-value test.

  • PDF

The FPGA Implementation of Wavelet Transform Chip using Daubechies′4 Tap Filter for DSP Application

  • Jeong, Chang-Soo;Kim, Nam-Young
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 1999년도 추계종합학술대회 논문집
    • /
    • pp.376-379
    • /
    • 1999
  • The wavelet transform chip is implemented with Daubechies' 4 tap filter. It works at 20MHz in Field Programmable Gate array (FPGA) implementation of Quadrature Mirror Filter(QMF) Lattice Structure. In this paper, the structure contains taro-channel quadrature mirror filter, data format converter(DFC), delay control unit(DCU), and three 20$\times$8 bits real multiplier. The structures for the DFC and DCU need to he regular and scalable, require minimum number of regular, and thereby lead to an efficient and scalable architecture for the Discrete Wavelet Transform(DWT). These results present the possibility that it can be used in Digital Signal Processing(DSP) application faster than Fourier transform at small area with lour cost.

  • PDF

우주전파 관측용 연속파 수신시스템 제작에 관한 연구 (A Study on the Manufacture of the Continuum Receiver System for Observing Cosmic Radio Waves)

  • 서정빈;이창훈;임인성;한석태
    • 전자공학회논문지B
    • /
    • 제31B권9호
    • /
    • pp.67-75
    • /
    • 1994
  • In this paper, we manufactured the continuum receiver system for observing the continuum waves emitted from the continuum sources with using the 14m radio-telescope. The receiving system measures the total power of the continuum sources and consists of DC-amplifier, beam-chopper system. Phase-Locked Loop(PLL) circuit, blanking circuit and its period selection circuit, V/F converter, and counter part which are capable of interfacing with the computer which is used for a data acquisition and making the radio-telescope track the source. We compared the obsevation results which use the existing DVM method with the observation results which use the continuum receiver to measure the total power of the sources. Moreover, by method of beam switching observation which uses newly installed beam chopper system. We can significantly improve the observational efficiency more than the existing position switching observation method.

  • PDF

디지털 셀룰라 시스템을 위한 개선된 GMSK 직교 변조기의 설계 (A design of an improved GMSK quadrature modulator for digital cellular system)

  • 송영준;한영열
    • 전자공학회논문지A
    • /
    • 제33A권6호
    • /
    • pp.32-41
    • /
    • 1996
  • We propose the improved GMSK (gaussian-filtered minimum shift keying) quadrature modulator using the FIR(finite impulse response )filter whose coefficients are obtained form the differnce of phase response, and design its ASIC (applicaton specific integrated circuit) which can be used for GSM (global system for mobile communication) digital cellular system and DCS 1800 (digital cellular system at 1800MHz) personal communication system. Input data become quantized I and Q channel 10 bit signal through cosine and sine ROM mapping after being filtered by the FIR filter whose normalized bandwidth is 0.3 and designed by considering intersymbol interference as well as sampling ratio. These two signals become the GMSK modulated I and Q channel signal through DAC (digital-to-analog converter) and 7th order analog chebyshev LPF(low pass filter) respectively. The difference between the ideal analog signal and its digitized signal is analyzed in terms of sampling noise, quantization noise, truncation noise and coefficient noise. And the effect of the LPF following the DAC is considered. The ASIC design of the GMSK quadrature modulator is also confirmed by an experiment.

  • PDF

운전 중인 전력기기의 부분방전 측정장치 개발에 관하여 (Development of On-Line Patial Discharge Detector for Power)

  • 김광화;선종호;김우성;이종구;이준모;강창원
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2000년도 추계학술대회 논문집
    • /
    • pp.733-739
    • /
    • 2000
  • This paper is described the development of on-line partial discharge detector for high voltage apparatus. This detector consists of acoustic and high frequency current sensors, amplifier part, A/D converter part, data communication part and computer. The contents of paper are characteristics of units and digital signal processing for reducing noise in partial discharge detection. We seek methods to do good digital signal processing for detection of partial discharge. We apply digital filtering methods to the elect Tic signal and a cross con-elation to the acoustic signal. This paper shows the characteristics of these filtering method and cross con-elation in partial discharge detection.

  • PDF

4 채널의 Photo-plethysmogram 시스템 구현에 관한 연구(I) (Implementation of 4 Channel Photo-Plethysmogram System(I))

  • 김형태;한순천;김정국;허웅;박영배
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2002년도 하계종합학술대회 논문집(5)
    • /
    • pp.253-256
    • /
    • 2002
  • In this paper, we implement the volume pulse detection system which can quantitatively represent an artery elasticity. The system consists of transducer which has IRLED-photodiode detecter, temperature sensor, filters, preprocessing circuits, A/D converter, serial communication part and computer system. In order to presume the artery elasticity information we measure the volume pulse at four points and then evaluate the transition time, distance and the correlation coefficient of the pulse wave between the points. We test the system with 10 subjects during the week for basic experiment and obtain the data at four points. As the result of experiment, we can detect normalized volume pulse wave and evaluated parameter with effectively.

  • PDF