• Title/Summary/Keyword: Data Value

Search Result 16,906, Processing Time 0.048 seconds

Research on Changing of Renal Relative Uptake Depending on the Setting of Background ROI in Kidney MAG3 Study of Hydronephrosis Patients (Hydronephrosis 환자의 Kidney MAG3 검사 시 Background ROI 설정에 따른 신장 상대 섭취율 변화에 관한 연구)

  • Noh, Ik Sang;Ahn, Byung Ho;Kim, Soo Yung;Choi, Sung Wook
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.17 no.2
    • /
    • pp.25-30
    • /
    • 2013
  • Purpose: To evaluate kidney function, renal relative uptake is very important and is affected by kidney and the setting of background region of interest (ROI). In particular, in the case of patients with hydronephrosis to the naked eyes, such as size, position and shape etc. can be difficult to identify. So according to ROI to be set by user, the results are many differences. This study assumes the ROI of a constant kidney. According to the change of background ROI by analyzing renal relative uptake affect how the results are intended to study. Materials and Methods: From January 2012 to February 2013, we analyzed 27 patients with hydronephrosis who were examined MAG3 test in nuclear medicine department of Samsung medical center. After patients were received intravenous injection of $^{99m}Tc-MAG3$ 185 MBq (5 mCi) data were obtained. While we reconstructed images of patients, we've changed background ROI in the process of setting up ROI. First, in the process of renal processing, automatic ROI which set automatically and background ROI which needed to set manually were compared. Second, we set the ROI position separated by above, lateral and bottom of kidney. Third, background setting time were compared with 1-2 min and 2-3 min. Results: The relative uptake occurred in 3.7%p of the errors on average in Automatic & Manual ROI study. And comparison of background ROI position study, located in the lower position was more accurate results. Above, lateral, bottom each of the values 74.6%, 67.6% and 62.0% showed respectively. The standard value was 59.9%. finally, split function range test doesn't show significant difference. Conclusion: The study shows that relative uptake of kidney is affected in the background ROI. Therefore, it should be set by considering various dependent factors.

  • PDF

A Diagnosis of Ecological Health Using a Physical Habitat Assessment and Multimetric Fish Model in Daejeon Stream (물리적 서식지평가기법 및 어류 다변수 평가모델에 의거한 대전천의 생태학적 건강도 진단)

  • Kim, Ja-Hyun;An, Kwang-Guk
    • Korean Journal of Ecology and Environment
    • /
    • v.38 no.3 s.113
    • /
    • pp.361-371
    • /
    • 2005
  • The objective of study was to diagnose integrative ecological health of Daejeon Stream, one of the tributaries of Guem River, during May 2004 ${\sim}$ April 2005. The research approach was primarily based on a Qualitative Habitat Evaluation Index (QHEI) and the Index of Biological Integrity (IBI) using fish assemblage. These outcomes were compared with conventional chemical dataset. For the experiment, four sampling sites were chosen from Daejeon Stream and long-term water quality data during 1995 ${\sim}$ 2004 (obtained from the Ministry of Environment) were analyzed in the spatial and temporal aspects. For the biological health assessment, we developed a stream health assessment model (SHA model) far regional applications. We found that current water quality conditions, based on the COD, BOD, TN and TP, were enhanced by 1.6 ${\sim}$ 5.3 fold over the period of 1995 ${\sim}$ 2004 and that the parameters showed a typical longitudinal decline from the upstream to downstream reach. The differences of water quality between the two reaches were more than 4.4 times, indicating a large spatial variations within the stream. The health conditions, based on the SHA model, averaged 23 and varied from 20 to 26 depending on the sampling stations. Values of the QHEI varied from 39 (Poor condition) to 124 (Cood condition)and values of QHEI in the reach of S2 ${\sim}$ S4 had significantly lower than in the headwater site (S1). Also, biological stream health, based on the criteria of US EPA (1993), was judged as 'Poor condition', in the S4 where TN, TP, BOD and COD were highest. In the meantime, maximum value of SHA (26) was found in the upstream reach (S1) where the water quality and QHEI were best. We also found that compositions of sensitive species showed a linear function with water quality conditions and this pattern was evident in the tolerant species. Thus, the biological stream health, based on the SHA model, matched well water chemistry. Overall outcomes suggest that the biological health impact was a function of chemical degradation and physical habitat quality in the stream.

A Study on the Fermentative Abilities and Baking Properties of Commercial Yeast (시판 빵 효모의 발효 특성 및 제빵성에 관한 연구)

  • Kim Won-Joo;Hahn Young-Sook
    • Korean journal of food and cookery science
    • /
    • v.20 no.5
    • /
    • pp.529-536
    • /
    • 2004
  • In this study, the author examined the fermentative abilities and baking properties of commercial baker's yeasts and suggested the fundamental data for the development of the yeast products industry. Carbon dioxide production, expansion abilities of doughs, and maltose fermentative abilities were measured with commercial yeasts. The fermentative abilities of various bread doughs were determined in comparison to a reference yeast and a selected yeast from commercial yeast. Various breads were prepared by these two yeasts and their sensory properties were evaluated. Y7, followed by Y5 and Y4, showed higher ability than any other commercial yeasts in the gassing power of the dough, as measured by a Meissle fermenter. In the expansion abilities of the doughs made from various yeasts by M-Cylinder, Y7, followed by Y4 and Y5, showed the best expansion ability the results were similar to those for gassing power. Therefore, Y7 was selected. The maltose fermentative abilities of various yeasts in Atkin's liquid medium showed a higher value in Y5, Y7 and Y 4. Selected yeast Y7 and the reference yeast K were used for determining the fermentative abilities of various bread doughs. For the various breads prepared by K and Y7, the qualities of the breads such as volume, weight and specific volume were measured. The volume by Y7 was higher in the straight dough bread, and that by K was higher in the sponge dough bread. In the sweet dough bread, both Y7 and K were excellent groups for it. Sensory properties of various breads made from K scored high on the items such as external properties and color in the straight dough bread. It also acquired a good score on the item of the crusts in the sweet dough bread. The overall acceptability of Y7 and K were similar.

GnRH Agonist Stimulation Test (GAST) for Prediction of Ovarian Response in Controlled Ovarian Stimulation (COH) (난소기능평가를 위한 Gonadotropin Releasing Hormone Agonist Stimulation Test (GAST)의 효용성에 관한 연구)

  • Kim, Mee-Ran;Song, In-Ok;Yeon, Hye-Jeong;Choi, Bum-Chae;Paik, Eun-Chan;Koong, Mi-Kyoung;Song, Il-Pyo;Lee, Jin-Woo;Kang, Inn-Soo
    • Clinical and Experimental Reproductive Medicine
    • /
    • v.26 no.2
    • /
    • pp.163-170
    • /
    • 1999
  • Objectives: The aims of this study are 1) to determine if GAST is a better indicator in predicting ovarian response to COH compared with patient's age or basal FSH level and 2) to evaluate its role in detecting abnormal ovarian response. Design: Prospective study in 118 patients undergoing IVF-ET using GnRH-a short protocol during May-September 1995. Materials and Methods: After blood sampling for basal FSH and estradiol $(E_2)$ on cycle day two, 0.5ml (0.525mg) GnRH agonist ($Suprefact^{(r)}$, Hoechst) was injected subcutaneously. Serum $E_2$ was measured 24 hours later. Initial $E_2$ difference $({\Delta}E_2)$ was defined as the change in $E_2$ on day 3 over the baseline day 2 value. Sixteen patients with ovarian cyst or single ovary or incorrect blood collection time were excluded from the analysis. The patients were divided into three groups by ${\Delta}E_2$; group A (n=30):${\Delta}E_2$<40 pg/ml, group B (n=52): 40 pg/ml${\leq}{\Delta}E_2$<100 pg/ml, group C (n=20): ${\Delta}E_2{\leq}100$ pg/ml. COH was done by GnRH agonist/HMG/hCG and IVF-ET was followed. Ratio of $E_2$ on day of hCG injection over the number of ampules of gonadotropins used ($E_2hCGday$/Amp) was regarded as ovarian responsiveness. Poor ovarian response and overstimulation were defined as $E_2$ hCGday less than 600 pg/ml and greater than 5000 pg/ml, respectively. Results: Mean age $({\pm}SEM)$ in group A, B and C were $33.7{\pm}0.8^*,\;31.5{\pm}0.6\;and\;30.6{\pm}0.5^*$, respectively ($^*$: p<0.05). Mean basal FSH level of group $A(11.1{\pm}1.1mlU/ml)$ was significantly higher than those of $B(7.4{\pm}0.2mIU/ml)$ and C $(6.8{\pm}0.4mIU/ml)$ (p<0.001). Mean $E_2hCGday$ of group A was significantly lower than those of group B or C, i.e., $1402.1{\pm}187.7pg/ml,\;3153.2{\pm}240.0pg/ml,\;4078.8{\pm}306.4pg/ml$ respectively (p<0.0001). The number of ampules of gonadotropins used in group A was significantly greater than those in group B or C: $38.6{\pm}2.3,\;24.2{\pm}1.1\;and\;18.5{\pm}1.0$ (p<0.0001). The number of oocytes retrieved in group A was significantly smaller than those in group B or C: $6.4{\pm}1.1,\;15.5{\pm}1.1\;and\;18.6{\pm}1.6$, respectively (p<0.0001). By stepwise multiple regression, only ${\Delta}E_2$ showed a significant correlation (r=0.68, p<0.0001) with $E_2HCGday$/Amp, while age or basal FSH level were not significant. Likewise, only ${\Delta}E_2$ correlated significantly with the number of oocytes retrieved (r=0.57, p<0.001). All four patients whose COH was canceled due to poor ovarian response belonged to group A only (Fisher's exact test, p<0.01). Whereas none of 30 patients in group A (0%) had overstimulation, 14 patients among 72 patients (19.4%) in group B and C had overstimulation (Fisher's exact test, p<0.01). Conclusions: These data suggest that initial $E_2$ difference after GAST may be a better prognostic indicator of ovarian response to COH than age or basal FSH level. Since initial $E_2$ difference demonstrates significant association with abnormal ovarian response such as poor ovarian response necessitating cycle cancellation or overstimulation, GAST may be helpful in monitoring and consultation of patients during COH in IVF-ET cycle.

  • PDF

Diagnostic Performance of HPV E6/E7 mRNA and HPV DNA Assays for the Detection and Screening of Oncogenic Human Papillomavirus Infection among Woman with Cervical Lesions in China

  • Wang, Hye-young;Lee, Dongsup;Park, Sunyoung;Kim, Geehyuk;Kim, Sunghyun;Han, Lin;Yubo, Ren;Li, Yingxue;Park, Kwang Hwa;Lee, Hyeyoung
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.16 no.17
    • /
    • pp.7633-7640
    • /
    • 2015
  • Background: Human papillomavirus (HPV) is the most common sexually transmitted infection worldwide and it is responsible for most cases of cervical uterine cancer. Although HPV infections of the cervix do not always progress to cancer, 90% of cervical cancer cases have been found to be associated with high risk HPV (HR-HPV) infection. HPV DNA testing is widely used, along with Papanicolaou (Pap) testing, to screen for cervical abnormalities. However, there are no data on the prevalence of genotype-specific HPV infections assessed by measuring HPV E6/E7 mRNA in women representative of the Chinese population across a broad age range. Materials and Methods: In the present study, we compared the results with the CervicGen HPV RT-qDx assay, which detects 16 HR-HPV genotypes (Alpha-9: HPV 16, 31, 33, 35, 52, and 58; Alpha-7: HPV 18, 39, 45, 51, 59, and 68; and Alpha-5, 6: HPV 53, 56, 66, and 69), and the REBA HPV-ID assay, which detects 32 HPV genotypes based on the reverse blot hybridization assay (REBA) for the detection of oncogenic HPV infection according to cytological diagnosis. We also investigated the prevalence and genotype distribution of HPV infection with a total of 324 liquid-based cytology samples collected in western Shandong province, East China. Results: The overall HPV prevalences determined by HPV DNA and HPV E6/E7 mRNA assays in this study were 79.9% (259/324) and 55.6% (180/324), respectively. Although the positivity of HPV E6/E7 mRNA expression was significantly lower than HPV DNA positivity, the HPV E6/E7 mRNA assay showed greater specificity than the HPV DNA assay (88.6% vs. 48.1%) in normal cytology samples. The prevalence of Alpha-9 (HPV 16, 31, 33, 35, 52, and 58) HPV infection among these women accounted for up to 80.3% and 76.1% of the high-grade lesions detected in the HPV mRNA and DNA tests, respectively. The HR-HPV genotype distribution, based on HPV DNA and E6/E7 mRNA expression by age group in patients with cytologically confirmed lesions, was highest in women aged 40 to 49 years (35.9% for cytologically confirmed cases, Pearson correlation r value=0.993, p<0.001) for high-grade lesions. Among the oncogenic HR-HPV genotypes for all age groups, there was little difference in the distribution of HPV genotypes between the HPV DNA (HPV -16, 53, 18, 58, and 33) and HPV E6/E7 mRNA (HPV -16, 53, 33, 58, and 18) assays. HPV 16 was the most common HPV genotype among women with high-grade lesions. Conclusions: Our results suggest that the HPV E6/E7 mRNA assay can be a sensitive and specific tool for the screening and investigation of cervical cancer. Furthermore, it may provide useful information regarding the necessity for early cervical cancer screenings and the development of additional effective HPV vaccines, such as one for HPV 53 and 58. Additionally, gaining knowledge of HPV distribution may also inform us about ecological changes in HPV after the vaccination.

Analysis of the Mean Uranium Valence of $U_{1-y}Er_{y}O_{2{\pm}x}$ Solid Solutions in terms of Lattice Parameter and Oneen Potential (격자상수 및 산소포텐샬에 의한 $U_{1-y}Er_{y}O_{2{\pm}x}$ 고용체의 평균우라늄원자가 분석)

  • Kim, Han-Soo;Sohn, Dong-Seong
    • Nuclear Engineering and Technology
    • /
    • v.28 no.2
    • /
    • pp.118-128
    • /
    • 1996
  • The lattice parameters of stoichiometric $UO_2$ and $U_{1-y}Er_{y}O_2$ in the range of y=0.01 to y =0.33 were determined with use of X-ray diffraction data. Oxygen potentials have been measured by means of a thermogravimetric method in the range of 1200~$1500^{\circ}C$ and $10^{-14}$ $\leq$ $Po_2$ $\leq$ $10^{-3}$ for pure $UO_2$ and $U_{1-y}Er_{y}O_{2{\pm}x}$ solid solutions with y=0.02, y=0.06 and y=0.20, respectively. Their oxygen partial pressures were maintained by controlling $CO_2$/CO mixture atmosphere, and the $Po_2$ values corresponding to x of $U_{1-y}Er_{y}O_{2{\pm}x}$ solid solutions were measured with an electrolyte oxygen sensor. The lattice parameter decreases linearly with an increase in the erbium content. The change of the lattice parameter can be expressed in a linear equation of y as a($\AA$) =5.4695-0.220y for 0 $\leq$y$\leq$0.33. The experimental coefficient of y -0.220 in $U_{1-y}Er_{y}O_2$ was an intermediate value between the calculated values -0.273 and -0.156 in the case of $U^{5+}$ and $U^{6+}$, respectively. The (equation omitted) has been found to undergo abrupt increase in the range of -360 to -270 kJ/mole for y=0.06 and -320 to -220 H/mole for y=0.20, respectively, in the temperature range of 1200-$1500^{\circ}C$. (equation omitted) increases with erbium content, but the effect of the dopant for x =0.01 is less significant than that for stoichiometry. The oxygen potentials for $UO_2$ and $U_{0.98}Er_{0.02}O_{2+x}$ can be approximately represented by the $U^{5+}$/$U^{4+}$ model but those for y$\geq$ 0.06 in $U_{1-y}Er_{y}O_{2{\pm}x}$ solid solutions cannot be interpreted by the mean uranium valence model.

  • PDF

Economic Analysis of the Livestock Manure Treatment System Using Life-Cycle Cost Technique (LCC 기법을 통한 가축분뇨처리시설의 경제성 분석)

  • Kim, J.H.;Cho, S.H.;Kwag, J.H.;Choi, D.Y.;Jeong, K.H.;Chung, U.S.;Chung, M.S.;Park, S.K.
    • Journal of Animal Environmental Science
    • /
    • v.17 no.sup
    • /
    • pp.61-68
    • /
    • 2011
  • To assess the total cost with all stages of facilities, the feasibility of Life Cycle Cost (LCC) analysis was examined in this study to estimate the livestock manure treatment system and optimal decision making process. For the economic evaluation, the plant/equipment investment and annual operation cost of four Public Livestock Recycling Facilities, whose treatment capacity is 100 ton piggery manure per day, was compared. The initial cost was in the range of 2,699 million won to 3,202 million won, where T and E methods were highest and lowest, respectively. The annual operation cost was in the level of 378 million to 498 million won, which decreased in the following order : T method > J method > E method > B method. For the LCC analysis, 4.7% of interest rate, 3.13% of inflation rate, and 1.52% of net discount rate was considered by the data received from Bank of Korea and Statics Korea in the period of 2000 to 2009. Also, for the calculation of present value factor, the durable years of civil engineering & construction, machinery and electric instrument was 30 years, 10 years and 15 years, respectively. Based on these consideration, operation cost was in the range of 17,570 won/ton to 20,661 won/ton, and E method (17,570 won/ton) was economical and B method (20,661 won/ton) was non-economical. Though initial cost of T method was higher than that of B method, LCC analysis of T method was lower than that of T method due to the lower operation cost. Therefore, LCC analysis, which considers both initial cost and operation cost, is more reasonable evaluation method than either initial cost or annual operation cost. For the change of LCC analysis according to the uncertainty, the sensitivity analysis was carried out using fluctuation magnitude of discount rate in the period of 2000 to 2009. As a result, LCC analysis evaluated by discount rate was stable for the uncertain factors since the cost leadership did not change even though the sensitivity analysis varied. In summary, the economic evaluation using LCC analysis could be an efficient reference to choose the suitable livestock manure treatment plants. Furthermore, standardization of statement calculation for the actual cost analysis should be conducted and more detailed study is necessary to validate this summary. Therefore, the application of comprehensive technology evaluation, which considers LCC analysis, should contribute in obtaining objectivity and enhancing reliability for the 'Evaluation of Livestock Manure Treatment System and its Technology'.

A study on the temperature inside clothing as fundamental data for development of the heat energy harvesting clothing (인체 전력에너지 수확의류 개발을 위한 의복내 온도 측정의 기초적 고찰)

  • Yang, Jin-Hee;Cho, Hyun-Seung;Park, Sun-Hyung;Lee, Joo-Hyeon
    • Science of Emotion and Sensibility
    • /
    • v.16 no.1
    • /
    • pp.125-132
    • /
    • 2013
  • Recently, the consciousness of energy crisis is rapidly growing and sustainable eco-friendly energy sources are becoming issue. Therefore the portable electronic device requires new energy sources for providing continuous power supply and the power energy harvesting system of the human body that enables the power-harvesting research requests anytime, anywhere. One of the sources for energy harvesting is heat energy, which is the difference in temperature of the body and the surrounding environment. We tried to analyze the temperature difference between the environmental temperature and the temperature inside clothing according to the structure of the closed portion. And we examined the temperature difference between the environmental temperature and the temperature inside clothing according to the material of the clothing. The analysis showed that we have been able to get different results at parts of the body in the temperature inside clothing according to the structure of clothing. In upper torso of the chest and back, the temperature inside clothing of 'closed structure' was higher than the temperature inside clothing of 'opened structure'. In the section of arm and leg, it was reduced the difference of temperature inside clothing between 'closed structure' and 'opened structure'. It was particularly noticeable in the section of leg. The results of analysis of the difference between the environmental temperature and the temperature inside clothing according to the material of the clothing, in both cases of the two materials, 'closed structure' was higher than the 'opened structure' in the difference value between the environmental temperature and the temperature inside clothing. There was a difference according to the material in the section of leg. In this study, we outlined the basic guidelines for developing heat energy harvesting clothing by exploring the structure and material of clothing suitable for the heat energy harvesting.

  • PDF

A Numerical Study of Hydraulic Fractures Propagation with Rock Bridges (Rock bridges를 고려한 수치 해석적 수압파쇄 균열거동 연구)

  • 최성웅
    • Tunnel and Underground Space
    • /
    • v.10 no.3
    • /
    • pp.447-456
    • /
    • 2000
  • Rock bridge in rock masses can be considered as one of several types of opening-mode fractures, and also it has been known to have a great influence on the stability of structures in rock mass. In the beginning of researching a rock bridge it used to be studied only in characteristics of its behavior, as considering resistance of material itself. However the distribution pattern of rock bridges, which can affect the stability of rock structures, is currently researched with a fracture mechanical approach in numerical studies. For investigating the effect of rock bridges on the development pattern of hydraulic fractures, the author analyzed numerically the stress state transition in rock bridges and their phenomena with a different pattern of the rock bridge distributions. From the numerical studies, a two-crack configuration could be defined to be representative of the most critical conditions for rock bridges, only when cracks are systematic and same in their length and angle. Moreover, coalescence stresses and onset of propagation stresses could be known to increase with decreasing s/L ratio or increasing d/L ratio. The effect of pre-existing crack on hydraulic fracturing was studied also in numerical models. Different to the simple hydraulic fracturing modeling in which the fractures propagated exactly parallel to the maximum remote stress, the hydraulic fractures with pre-existing cracks did not propagate parallel to the maximum remote stress direction. These are representative of the tendency to change the hydraulic fractures direction because of the existence of pre-existing crack. Therefore s/L, d/L ratios will be identical as a function effective on hydraulic fractures propagation, that is, the K$_1$ value increase with decreasing s/L ratio or increasing d/L ratio and its magnification from onset to propagation increases with decreasing s/L ratio. The scanline is a commonly used method to estimate the fracture distribution on outcrops. The data obtained from the scanline method can be applied to the evaluation of stress field in rock mass.

  • PDF

The Influence of Iteration and Subset on True X Method in F-18-FPCIT Brain Imaging (F-18-FPCIP 뇌 영상에서 True-X 재구성 기법을 기반으로 했을 때의 Iteration과 Subset의 영향)

  • Choi, Jae-Min;Kim, Kyung-Sik;NamGung, Chang-Kyeong;Nam, Ki-Pyo;Im, Ki-Cheon
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.14 no.1
    • /
    • pp.122-126
    • /
    • 2010
  • Purpose: F-18-FPCIT that shows strong familiarity with DAT located at a neural terminal site offers diagnostic information about DAT density state in the region of the striatum especially Parkinson's disease. In this study, we altered the iteration and subset and measured SUV${\pm}$SD and Contrasts from phantom images which set up to specific iteration and subset. So, we are going to suggest the appropriate range of the iteration and subset. Materials and Methods: This study has been performed with 10 normal volunteers who don't have any history of Parkinson's disease or cerebral disease and Flangeless Esser PET Phantom from Data Spectrum Corporation. $5.3{\pm}0.2$ mCi of F-18-FPCIT was injected to the normal group and PET Phantom was assembled by ACR PET Phantom Instructions and it's actual ratio between hot spheres and background was 2.35 to 1. Brain and Phantom images were acquired after 3 hours from the time of the injection and images were acquired for ten minutes. Basically, SIEMENS Bio graph 40 True-point was used and True-X method was applied for image reconstruction method. The iteration and Subset were set to 2 iterations, 8 subsets, 3 iterations, 16 subsets, 6 iterations, 16 subsets, 8 iterations, 16 subsets and 8 iterations, 21 subsets respectively. To measure SUVs on the brain images, ROIs were drawn on the right Putamen. Also, Coefficient of variance (CV) was calculated to indicate the uniformity at each iteration and subset combinations. On the phantom study, we measured the actual ratio between hot spheres and back ground at each combinations. Same size's ROIs were drawn on the same slide and location. Results: Mean SUVs were 10.60, 12.83, 13.87, 13.98 and 13.5 at each combination. The range of fluctuation by sets were 22.36%, 10.34%, 1.1%, and 4.8% respectively. The range of fluctuation of mean SUV was lowest between 6 iterations 16 subsets and 8 iterations 16 subsets. CV showed 9.07%, 11.46%, 13.56%, 14.91% and 19.47% respectively. This means that the numerical value of the iteration and subset gets higher the image's uniformity gets worse. The range of fluctuation of CV by sets were 2.39, 2.1, 1.35, and 4.56. The range of fluctuation of uniformity was lowest between 6 iterations, 16 subsets and 8 iterations, 16 subsets. In the contrast test, it showed 1.92:1, 2.12:1, 2.10:1, 2.13:1 and 2.11:1 at each iteration and subset combinations. A Setting of 8 iterations and 16 subsets reappeared most close ratio between hot spheres and background. Conclusion: Findings on this study, SUVs and uniformity might be calculated differently caused by variable reconstruction parameters like filter or FWHM. Mean SUV and uniformity showed the lowest range of fluctuation at 6 iterations 16 subsets and 8 iterations 16 subsets. Also, 8 iterations 16 subsets showed the nearest hot sphere to background ratio compared with others. But it can not be concluded that only 6 iterations 16 subsets and 8 iterations 16 subsets can make right images for the clinical diagnosis. There might be more factors that can make better images. For more exact clinical diagnosis through the quantitative analysis of DAT density in the region of striatum we need to secure healthy people's quantitative values.

  • PDF