• Title/Summary/Keyword: Data Disturbance

Search Result 777, Processing Time 0.03 seconds

AN IMPROVED HEAT TRANSFER CORRELATION FOR DEVELOPING POST-DRYOUT REGION IN VERTICAL TUBES

  • NGUYEN, NGOC HUNG;MOON, SANG-KI
    • Nuclear Engineering and Technology
    • /
    • v.47 no.4
    • /
    • pp.407-415
    • /
    • 2015
  • A developing post-dryout region is characterized by significant heat transfer enhancements compared with the fully developed post-dryout region. The heat transfer enhancements are mainly due to upstream disturbance and entrained droplets in the region immediately downstream of the critical heat flux location. In this paper, an improved heat transfer correlation is developed for the developing post-dryout regions in vertical tubes over a wide range of flow conditions. The correlation represents a correction factor for the fully developed film-boiling look-up table to be applied to the developing post-dryout region. The new correlation significantly improves the heat transfer prediction in the developing post-dryout regions and provides very good agreement with the experimental data.

Active Vibration Control of Slewing Smart Beam (회전지능보의 능동진동제어)

  • Nam, Sang-Hyun;Kwak, Moon-Kyu
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2000.06a
    • /
    • pp.257-262
    • /
    • 2000
  • This research is concerned with the active vibration control of slewing smart structures subjected to rotating disturbance. When cantilever beam rotates about axes perpendicular to the undeformed beam's longitudinal axis, it experiences inertial loading. Hence, the beam vibrates after the slewing ends. In this paper, the analytical model for a single slewing flexible beam with surface bonded piezoelectric sensor and actuator is developed using the Hamilton's principle with discretization by the assumed mode method. The theoretial model is verified by the experimental open loop frequency response data. The controller is designed for residual vibration suppression after slewing. The designed cotroller is a positive position feedback (PPF) controller for controlling the first mode vibration.

  • PDF

Conduits for Coronary Bypass: Arteries Other Than the Internal Thoracic Artery's

  • Barner, Hendrick B.
    • Journal of Chest Surgery
    • /
    • v.46 no.3
    • /
    • pp.165-177
    • /
    • 2013
  • This is the third in a series on coronary artery bypass which reviews three alternative arterial conduits. The radial artery has become the most widely used of the three and accumulating experience demonstrates better patency at 10 years versus saphenous vein. Drawbacks are a long incision on the forearm, the propensity for spasm and persistent sensory disturbance in about 10%. The first is answered by endoscopic harvest which may yield a shorter conduit but reduces sensory nerve injury. Spasm is managed pharmacologically and by less harvest trauma. The gastroepiploic artery is used in situ and free and although the abdominal cavity is entered complications are minimal and patency compares favorably with the radial artery. Use of the inferior epigastric artery remains minimal and its similar length often requires composite use but limited patency data are supportive. Other arteries have had rare use and this is unlikely to change because the three presented here have significant advantages and acceptance.

A Study on Minimum Time Position Control of DC Servo-Motor (DC Servo Motor의 최단시간 위치 제어)

  • 양주호
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.28 no.1
    • /
    • pp.39-44
    • /
    • 1992
  • Analog PID controllers have been designed to make good use of position control in industries. Recently, the importance of digital position control is emphasized for the requirements of controller which are not only to control the objects but to include various aspects such as easiness of design and implementation, simple exchange of control program and convenient communications of data between various controllers and a host computer. This study proposes a combined control method which is mixed the vaiable structure control (VSC) with the PI control for minimum time position control of DC servo motor by microcomputer. The results of test by this method show offset-free and minimum time optimal position control which is not affected by the disturbance and the system parameter variations. The validity of the proposed method comparing with the conventional PID control is proved by the response experiments.

  • PDF

Application to Real Time Repetitive Control in Belt Drive Systems (벨트 구동 시스템에서의 실시간 반복제어 응용)

  • 유영순
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.4 no.4
    • /
    • pp.420-426
    • /
    • 1998
  • It is the purpose of this paper to make a preliminary study on the use of repetitive control to improve velocity accuracy by eliminating repetitive disturbances caused by machining inaccuracies of the axis of rotation location. If the control system can be intelligent enough to compensate for such machining errors, then one may be able to improve the accuracy of the velocity control, or alternatively, one may maintain the same accuracy and relax the machining tolerances required. This could decrease cost significantly. Experiments are performed testing repetitive control methods on a constant speed rolling operation testbed. The experimental results show very substantial decreases in the tracking error of the system. Spectral data of the output motion are given to demonstrate the attenuation of the disturbance frequencies and harmonics, related to the bandwidth being used. It is seen that the simplest form of repetitive control which is very easily implemented, can produce striking improvement in control system performance in such belt drive rolling operations, and the learning can be accomplished in a short time.

  • PDF

Minamata Disease and the Mercury Pollution of the Globe

  • Harada Masazumi
    • Journal of Environmental Health Sciences
    • /
    • v.31 no.6
    • /
    • pp.451-456
    • /
    • 2005
  • Minamata disease made its first appearance in the world at Minamata City, Kumamoto Prefecture, in May 1956. In 1962 methyl mercury poisoning through the placenta was found for the first time in the world. This was called congenital Minamata disease. In all cases the clinical symptoms were consistent with those of cerebral palsy. The time and place of outbreak were the same as those for Minamata disease. Their mothers had eaten fish and shellfish during pregnancy. The principal symptoms of congenital Minamata disease are mentalretardation ($100\%$); primitive reflexes ($100\%$); disturbance of coordination ($100\%$); dysarthria ($100\%$); limb deformation (100%); growth disorders ($100\%$); nutritional disorders ($100\%$); chorea-athetose ($95\%$); and hypersalivation ($95\%$). However, today, when the world is polluted by mercury in various places and at various levels, the data we need is not represented by those severe cases, but rather by the chronic milder type. Even in Minamata, the issue of Minamata disease has not been resolved. And likewise, on a global scale the problem of Minamata disease is not yet over.

Improvement of Voltage Utilization in PWM Inverters (PWM 인버터의 전압 이용률 개선)

  • Lee, G.-Myoung;Lee, Dong-Choon
    • Proceedings of the KIEE Conference
    • /
    • 1997.11a
    • /
    • pp.518-520
    • /
    • 1997
  • In a space vector PWM inverter, the dc input voltage is utilized to the maximum by an overmodulation technique, which is derived from Fourier series expansion of the reference phase voltage. Data angles such reference angle and holding angle are piecewise-linearized for on-line control. Harmonic components and THD of the output voltage are also analyzed. For disturbance of the dc input voltage, a smooth transition is obtained from a linear range to the six-step mode by the control angle change.

  • PDF

Development of ELM based Load Modeling Method for Residential Loads (ELM을 이용한 주거용 부하의 부하모델링 기법 개발)

  • Jung, Young-Taek;Ji, Pyeong-Shik
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.61 no.1
    • /
    • pp.29-34
    • /
    • 2012
  • Due to the increasing of nonlinear loads such as converters and inverters connected to the electric power distribution system, and extensive application of harmonic generation sources with power electronic devices, disturbance of the electric power system and its influences on industries have been continuously increasing. Thus, it is difficult to construct accurate load model for active and reactive power in environments with harmonics. In this research, we develop a load modeling method based on Extreme Learning Machine(ELM) with fast learning procedure for residential loads. Using data sets acquired from various residential loads, the proposed method has been intensively tested. As the experimental results, we confirm that the proposed method makes it possible to effective estimate active and reactive powers than conventional methods.

A Comparative Study on Frequency Estimation Methods

  • Kim, Yoon Sang;Kim, Chul-Hwan;Ban, Woo-Hyeon;Park, Chul-Won
    • Journal of Electrical Engineering and Technology
    • /
    • v.8 no.1
    • /
    • pp.70-79
    • /
    • 2013
  • In this paper, a comparative study on the frequency estimation methods using IRDWT (Improved Recursive Discrete Wavelet Transform), FRDWT(Fast Recursive Discrete Wavelet Transform), and GCDFT(Gain Compensator Discrete Fourier Transform) is presented. The 345[kV] power system modeling data of the Republic of Korea by EMTP-RV is used to evaluate the performance of the proposed two kinds of RDWT(IRDWT and FRDWT) and GCDFT. The simulation results show that the frequency estimation technique based on FRDWT could be the optimal frequency measurement method, and thus can be applied to FDR(Fault Disturbance Recorder) for wide-area blackout protection or frequency measurement apparatus.

A Study of Semiconductor Process Control using Dual Damping EWMA (Dual Damping EWMA를 이용한 효율적인 반도체 공정 제어에 관한 연구)

  • Kim, Seon-Eok;Ko, Hyo-Heon;Kim, Jih-Yun;Kim, Sung-Shick
    • IE interfaces
    • /
    • v.21 no.2
    • /
    • pp.141-150
    • /
    • 2008
  • In this paper, an efficient control method for semiconductor fabrication process is presented. Generally, control is performed with data which is under the influence of process disturbance. EWMA is one of the most popular control methods in semiconductor fabrication that effectively deals with varying process condition. A new method using EWMA, called the Dual Damping EWMA, is presented in this study to reduce over-control by separating weight factor of input and output. The goal is to reflect Drift but reduce the effects of White noise in run to run control. Simulation is performed to evaluate the performance of DPEWMA and to compare with EWMA and Double EWMA.