• 제목/요약/키워드: Data Bias

검색결과 1,779건 처리시간 0.026초

High Current Stress characteristics on Sequential Lateral Solidification (SLS) Poly-Si TFT

  • Jung, Kwan-Wook;Kim, Ung-Sik;Kang, Myoung-Ku;Choi, Pil-Mo;Lee, Su-Kyeong;Kim, Hyun-Jae;Kim, Chi-Woo;Jung, Kyu-Ha
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2003년도 International Meeting on Information Display
    • /
    • pp.673-674
    • /
    • 2003
  • The reliability of TFT, crystallized by sequential lateral solidification (SLS) technology, has been studied High current damage is characterized by high gate bias (-20V) and drain bias (-10V). It is found that performance of SLS TFTs is enhanced by high current stress up to 300 sec of stress time for 20/8 (W/L) N-TFT. After that, TFT performance is degraded with the increase of the stress time. It is speculated from the experimental data that SLS TFTs initially contain a number of unstable defect states. Then, the defect states seem to be cured by high current stress.

  • PDF

Indentification of continuous systems in the presence of input-output measurement noises

  • Yang, Zi-Jiang;Sagara, Setsuo;Wada, Kiyoshi
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1990년도 한국자동제어학술회의논문집(국제학술편); KOEX, Seoul; 26-27 Oct. 1990
    • /
    • pp.1222-1227
    • /
    • 1990
  • The problem of identification of continuous systems is considered when both the discrete input and output measurements are contaminated by white noises. Using a predesigned digital low-pass filter, a discrete-time estimation model is constructed easily without direct approximations of system signal derivatives from sampled data. If the pass-band of the filter is designed so that it includes the main frequencies of both the system input and output signals in some range, the noise effects are sufficiently reduced, accurate estimates can be obtained by least squares(LS) algorithm in the presence of low measurement noises. Two classes of filters(infinite impulse response(IIR) filter and finite impulse response(FIR) filter) are employed. The former requires less computational burden and memory than the latter while the latter is suitable for the bias compensated least squares(BCLS) method, which compensates the bias of the LS estimate by the estimates of the input-output noise variances and thus yields unbiased estimates in the presence of high noises.

  • PDF

가정내의 식품분배에서 남.여의 차이에 대한 연구 (A Study on the Sex Bias in Intrahousehold Food Distribution)

  • 조미숙;강남이
    • 한국식품영양학회지
    • /
    • 제2권2호
    • /
    • pp.31-39
    • /
    • 1989
  • The objective of this study is to collect basic data about sex bias in intrahousehold food distribution, by investigating 124 housekeepers living in Seoul . This Survey was performed using questionnaire about the experience of male-female dietary disparity and the attitudes about sex-differential nutrition Results were summarized as follows ; 1. 38% of housekeepers had been experienced in male-female disparity of food distribution at meal time in her childhood. Protein foods(meats & fishes) and special foods were not distributed evenly to both sexes. 2. The major causes of these unbalanced, sex-differential food distribution was rather masculine priority than food shortage. 3. Compared with the past, male-female dietary disparity was disappeared. However, 47.7% of housekeepers took more care for son's meals than daughter's, consciously or unconsciously.

  • PDF

A Dual Problem of Calibration of Design Weights Based on Multi-Auxiliary Variables

  • Al-Jararha, J.
    • Communications for Statistical Applications and Methods
    • /
    • 제22권2호
    • /
    • pp.137-146
    • /
    • 2015
  • Singh (2013) considered the dual problem to the calibration of design weights to obtain a new generalized linear regression estimator (GREG) for the finite population total. In this work, we have made an attempt to suggest a way to use the dual calibration of the design weights in case of multi-auxiliary variables; in other words, we have made an attempt to give an answer to the concern in Remark 2 of Singh (2013) work. The same idea is also used to generalize the GREG estimator proposed by Deville and S$\ddot{a}$rndal (1992). It is not an easy task to find the optimum values of the parameters appear in our approach; therefore, few suggestions are mentioned to select values for such parameters based on a random sample. Based on real data set and under simple random sampling without replacement design, our approach is compared with other approaches mentioned in this paper and for different sample sizes. Simulation results show that all estimators have negligible relative bias, and the multivariate case of Singh (2013) estimator is more efficient than other estimators.

Current-voltage Characteristics of Ceramics with Positive Temperature Coefficient of Resistance

  • Li, Yong-Gen;Cho, Sung-Gurl
    • 한국세라믹학회지
    • /
    • 제40권10호
    • /
    • pp.921-924
    • /
    • 2003
  • A current-voltage relation for Positive Temperature Coefficient of Resistance (PTCR) ceramic was derived and compared with the experimental data. The new current-voltage relation was developed based on Heywangs double Schottky barrier model and a bias distribution across the grain boundary. The voltage limitation V < 4${\Phi}$$\sub$b/ suggested by Heywang is no longer necessary in the new expression for the voltage dependence of the resistance. The pulsed voltages were applied to the PTCR ceramic specimen in order to avoid possible temperature variation during the measurement.

비선형모델링을 통한 온습도 바이어스 시험 중의 다층 세라믹축전기 수명 예측 (Failure Prediction of Multilayer Ceramic Capacitors (MLCCs) under Temperature-Humidity-Bias Testing Conditions Using Non-Linear Modeling)

  • 권대일
    • 마이크로전자및패키징학회지
    • /
    • 제20권3호
    • /
    • pp.7-10
    • /
    • 2013
  • This study presents an approach to predict insulation resistance failure of multilayer ceramic capacitors (MLCCs) using non-linear modeling. A capacitance aging model created by non-linear modeling allowed for the prediction of insulation resistance failure. The MLCC data tested under temperature-humidity-bias testing conditions showed that a change in capacitance, when measured against a capacitance aging model, was able to provide a prediction of insulation resistance failure.

Analytic Model of Spin-Torque Oscillators (STO) for Circuit-Level Simulation

  • Ahn, Sora;Lim, Hyein;Shin, Hyungsoon;Lee, Seungjun
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • 제13권1호
    • /
    • pp.28-33
    • /
    • 2013
  • Spin-torque oscillators (STO) is a new device that can be used as a tunable microwave source in various wireless devices. Spin-transfer torque effect in magnetic multilayered nanostructure can induce precession of magnetization when bias current and external magnetic field are properly applied, and a microwave signal is generated from that precession. We proposed a semi-empirical circuit-level model of an STO in previous work. In this paper, we present a refined STO model which gives more accuracy by considering physical phenomena in the calculation of effective field. Characteristics of the STO are expressed as functions of external magnetic field and bias current in Verilog-A HDL such that they can be simulated with circuit-level simulators such as Hspice. The simulation results are in good agreement with the experimental data.

대체용매를 이용한 금속가공유 측정방법 타당성에 대한 현장평가 (Field Validation of alternative extraction method for the determination of airborne MWFs)

  • 정지연;백남원
    • 한국산업보건학회지
    • /
    • 제19권2호
    • /
    • pp.96-101
    • /
    • 2009
  • The purpose of this study was to conduct the field validation of alternative method(ETM method) by using non-carcinogenic, and less toxic solvents than NIOSH (National Institute for Occupational Safety and Health) analytical method 5524 for measuring the airborne metalworking fluids in workplaces. We carried out the field validation test by using the exposure chamber, guaranteeing the air sampling homogeneously in a machining environment. The ETM mixed solvent presented the complete solubility of MWFs used in test field. Based on the field test data, the bias of the ETM method from reference method, NIOSH analytical method 5524, was from -7.0% to 5.1%. The overall uncertainty of the ETM nethod was 21.6%, which satisfied the NIOSH criteria for the sampling and analytical criteria.

Test Results of Wide-Area Differential Global Positioning System with Combined Use of Precise Positioning Service and Standard Positioning Service Receiver

  • Kim, Kap Jin;Ahn, Jae Min
    • Journal of Positioning, Navigation, and Timing
    • /
    • 제10권1호
    • /
    • pp.43-48
    • /
    • 2021
  • Most existing studies on the wide-area differential global positioning system (WADGPS) used standard positioning service (SPS) receivers in their observation reference stations which provide the central control station global positioning system (GPS) measurements to generate augmentation data. In the present study, it is considered to apply a precise positioning service (PPS) receiver to an observation reference station which is located in the threatened jamming area. Therefore, the reference station network consists of a PPS receiver based observation reference station and SPS receiver based observation reference stations. In this case, to maintain correction performance P1C1 differential code bias (DCB) should be compensated. In this paper, P1C1 DCB estimation algorithm was applied to the PPS/WADGPS system and performance test results using measurements in the Korean Peninsula were presented.

Cosmological Tests using Redshift Space Clustering in BOSS DR11

  • Song, Yong-Seon;Sabiu, Cristiano G.;Okumura, Teppei;Oh, Minji;Linder, Eric V.
    • 천문학회보
    • /
    • 제40권1호
    • /
    • pp.43.3-44
    • /
    • 2015
  • We analyze the clustering of large scale structure in the Universe in a model independent method, accounting for anisotropic effects along and transverse to the line of sight. A large sample of 690,000 galaxies from The Baryon Oscillation Spectroscopy Survey Data Release 11 are used to determine the Hubble expansion H, angular distance D_A, and growth rate GT at an effective redshift of z=0.57. After careful bias and convergence studies of the effects from small scale clustering, we find that cutting transverse separations below 40 Mpc/h delivers robust results while smaller scale data leads to a bias due to unmodelled nonlinear and velocity effects. The converged results are in agreement with concordance LCDM cosmology, general relativity, and minimal neutrino mass, all within the $68{\backslash}%$ confidence level. We also present results separately for the northern and southern hemisphere sky, finding a slight tension in the growth rate -- potentially a signature of anisotropic stress, or just covariance with small scale velocities -- but within $68{\backslash}%$ CL.

  • PDF