• Title/Summary/Keyword: Dap-ho

Search Result 49, Processing Time 0.021 seconds

A Study of Dap-ho(塔胡) in Joseon Dynasty - Until the Early $17^{th}$ Century - (조선시대 답호(塔胡) 연구 - 17세기 전기까지 -)

  • Song, Mi-Kyung
    • Journal of the Korean Society of Costume
    • /
    • v.59 no.10
    • /
    • pp.51-67
    • /
    • 2009
  • The study is about 'Dap-ho', a kind of men's coat in the early, and mid period of Joseon Dynasty. The study examined the kinds, color, and fabric of Dap-ho from "The Annals of the Joseon Dynasty". It also examined the characteristic, and the change of shape through excavated costume, and the period is limited until early 17th century. In "The Annals of the Joseon Dynasty", there is record of Dap-ho from King Sejong period to Gwang-hae-gun period. After 160 years, it appears again in King Young-jo period, and remains until King Soon-jong period. It was mentioned 168 times, from over 100 cases. There are 26 colors of Dap-ho from "The Annals of the Joseon Dynasty", and among them, green appears the most. Thin fabric, like Joo [紬], Sa[紗], and Cho[綃] was used often, and there are records of double layered, and cotton padded Dap-ho. The period when Dap-ho appears as excavated costume is almost the same as, "The Annals of the Joseon Dynasty" and disappears after the decease of Dae-ho Kang(1541-1624), and Sun-un Yun(1580~1628). After in this period, Dan-ryung, and Jik-ryung changes into double layered clothes, and Jik-ryung functioned as the underclothes of Dan-ryung, instead of Dap-ho. The excavated costumes of Hwak Kim(1572~1633), and Eung-hae Lee(1547~1626) proofs this. But Dap-ho was called 'Jun-bok', 'Dugree', Que-ja', and 'Dap-ho' until the later period of Joseon Dynasty.

A study on the design using characteristic the Joseon dynasty Dap-ho (조선시대 답호의 조형특성을 응용한 디자인 연구)

  • Yeom, Soon Jeong;Kim, Eun Jung
    • Journal of the Korea Fashion and Costume Design Association
    • /
    • v.21 no.1
    • /
    • pp.87-101
    • /
    • 2019
  • The sleeve is closely connected with activity in terms of costume. As a kind of overcoat, Dap-ho of the Joseon Dynasty is short-sleeved or sleeveless. Dap-ho, with simple sleeves is convenient for layering and taking off and since it is easily adjustable using a gusset, a slit, or coat string, and this can be applied to layered look-related designs. This study aims to suggest a design item, which sustains the existence of traditional costumes and facilitates diverse layered looks and co-ordination, using the formative elements of Dap-ho. For this study, theoretical backgrounds and relics of Dap-ho of the Joseon Dynasty were analyzed, based on the previous studies, ancient literature, "The Annals of the Joseon Dynasty", and relics preserved in museums. The analysis targeted nine relics that show the birth and death years and the constructive changes in shapes, colors, materials of Dap-ho. Formative elements of Dap-ho were applied to the designing and the manufacturing of clothes for middle-aged women in their fifties and the research conclusions are as follows. First, from a morphological perspective, the silhouette, gusset, slit, and the indirectly attached coat string of Dap-ho are good to be used as various design items for covering the body shapes of middle-aged women, and the short-sleeved or sleeveless type is convenient to be layered. Second, when it comes to the material, it is possible to emphasize a traditional image and practicality at the same time by mixing and matching the Hanbok cloth and cotton. Third, in relation to the colors, the coexistence-based color arrangement method considering the theory of Yin and Yang can be applied to modern clothes and this makes it possible to express a traditional image in a harmonious way.

Synthesis and Characterization of Dimer Acid-Based Polyamides (다이머산계 폴리아미드의 합성 및 특성에 관한 연구)

  • Park, Hyun Ju;Jeon, Ho Kyun;Oh, Sang Taek
    • Journal of Adhesion and Interface
    • /
    • v.17 no.4
    • /
    • pp.136-140
    • /
    • 2016
  • In this study, a series of dimer acid-based polyamides with different diamines were synthesized by condensation polymerization and the polyamides were characterized by Fourier transform infrared spectroscopy (FT-IR). Effects of diamine structures on mechanical and thermal properties of polyamides were investigated. The tensile strength and lap shear adhesion strength of aromatic-based polyamide (DAP) were higher than those of aliphatic-based polyamide (DAH). In DSC thermogram, DAP has a high $T_g$ and $T_m$ compared with DAH. DAP's and DAH's softening point were $112-115^{\circ}C$ and $98-121^{\circ}C$, respectively.

Usability Evaluation by Development of IRIS Type X-ray Collimator (조리개형 X선 콜리메이터의 개발에 따른 유용성 평가)

  • Kang, In-Seog;Park, Jae-Yoon;Lim, Cheong-Hwan;Choi, Jae-Ho;Jung, Hong-Ryang
    • Journal of radiological science and technology
    • /
    • v.41 no.3
    • /
    • pp.249-254
    • /
    • 2018
  • In this study, we evaluated the DAP(Dose Area Product) reduction effect of the newly developed IRIS collimator by measuring the DAP of the Rectangle collimator and the IRIS collimator depending on the field, SID(Source to Image recpetor Distance) change, and AEC mode use. The results were as follows. The IRIS collimator decreased DAP by 34.91, 29.33, and 29.04%, respectively, compared to the Rectangle collimator when the field was increased to $8{\times}8$, $12{\times}12$, $16{\times}16inch$. And also, when the SID was increased to 100, 120 and 140 cm, the IRIS collimator decreased DAP by 10.73, 33.68 and 46.22%, respectively, compared to the Rectangle collimator. In AEC mode and none-AEC mode, DAP in IRIS collimator was reduced by 32.71 and 21.69%, respectively, compared with the Rectangle type. The IRIS collimator can reduce DAP by 29.62% on average compared to Rectangle type, which is statistically significant. These results suggest that the newly developed IRIS collimator can be used in medical field to alleviate radiation exposure.

Distributed Archiving Protocol between the Medical Sensor Nodes for the Home Health Service (홈 헬스를 위한 메디컬 센서노드의 분산보관 프로토콜)

  • Lee, Young-Ho;Jang, Hee-Tae;Lee, Byung-Mun
    • The Journal of the Korea Contents Association
    • /
    • v.12 no.1
    • /
    • pp.80-90
    • /
    • 2012
  • Medical data sampled through medical sensor nodes can provide services properly only when the data are not lost even during the fault of a home health gateway. The loss of medical data can be minimized if a sensor node, in which it is expected that there are the most saving spaces, is selected after medical sensor nodes tentatively conduct local save or communicate with each other during a fault when data cannot received. Furthermore, efficient saving techniques are necessary since the cycle for sampling information is different according to the type of medical data and a space for distributed saving is different for each apparatus. So, this research suggests an efficient distributed archiving protocol (DAP) for medical data sensor nodes, each of which has a diverse sampling cycle. In order to confirm the usefulness of DAP, DAP between sensor node and gateway was designed and materialized. An experiment was conducted using the materialized program and earned a high level of recovery rate (99.3%) and of accuracy rate, which confirms that sensor nodes can play their role during a temporary fault.

Studies on Complexation of some Lanthanides with Diaza-18-crown-6-diisopropionic Acid (란탄족(III)족 이온과 Diaza-18-crown-6-diisopropionic Acid의 착화합물에 관한 연구)

  • Jung Suk Kim;Chang Heon Lee;Sun Ho Han;Moo Yul Suh;Tae Yoon Eom;Jin Ha Park
    • Journal of the Korean Chemical Society
    • /
    • v.36 no.6
    • /
    • pp.840-848
    • /
    • 1992
  • An ionizable macrocyclic ligand, diaza-18-crown-6-diisopropionic acid(K22DAP) has been synthesized. Protonation constants of this compound and stability constants with some lanthanides were determined by potentiometric titration method. The protonation constants are log$K_1$ = 9.05, log$K_2$ = 8.37, log$K_3$ = 1.88 and log$K_4$ = 0.99. The logarithmic values of stability constants with La(III), Nd(III), Gd(III) and Lu(III) are 11.14, 11.43, 11.74 and 10.88 respectively. Extraction behavior of Ln(III) ion was investigated using TTA(thenoyltrifluoroacetone) as extractant in the presence of K22DAP as macrocyclic ionophore. It was observed that Ln(K22DAP)TTA is the dominating species in aqueous complexes of La(III) and Nd(III).

  • PDF

Development of DAP(Dose Area Product) for Radiation Evaluation of Medical and Industrial X-ray generator (의료 및 산업용 X-선 발생장치의 선량평가를 위한 면적선량계(DAP) 개발)

  • Kwak, Dong-Hoon;Lee, Sang-Heon;Lee, Seung-Ho
    • Journal of IKEEE
    • /
    • v.22 no.2
    • /
    • pp.495-498
    • /
    • 2018
  • In this paper, we propose an DAP system for dose evaluation of medical and industrial X-ray generator. Based on the DAP measurement technique using the Ion-Chamber, the proposed system can clearly measure the exposure radiation dose generated by the diagnostic X-ray apparatus. The hardware part of the DAP measures the amount of charge in the air that is captured by an X-ray. The high-speed processing algorithm part for cumulative radiation dose measurement through microcurrent measures the amount of charge captured by X-ray at a low implementation cost (power) with no input loss. The wired/wireless transmission/reception protocol part synchronized with the operation of the X-ray generator improves communication speed. The PC-based control program part for interlocking and aging measures the amount of X-ray generated in real time and enables measurement graphs and numerical value monitoring through PC GUI. As a result of evaluating the performance of the proposed system in an accredited testing laboratory, the measured values using DAP increased linearly in each energy band (30, 60, 100, 150 kV). In addition, since the standard deviation of the measured value at the point of 4 division was ${\pm}1.25%$, it was confirmed that the DAP showed uniform measurements regardless of location. It was confirmed that the normal operation was not less than ${\pm}4.2%$ of the international standard.

Preparation of Antioxidative Polyethylene Film and Its Effects on the Lipid Oxidation of Semi-dried Squid during Storage (항산화 성분을 함유한 PE 필름이 반건오징어 저장 중 지질산화에 미치는 영향)

  • Kim Young-Myung;Park Hyung-Woo;Byun Jee-Young;Kim Kwang-Ho
    • The Korean Journal of Food And Nutrition
    • /
    • v.18 no.1
    • /
    • pp.19-27
    • /
    • 2005
  • Antioxidative polyethylene films for food packaging were experimentally prepared by fortification of TBHQ(tertiary butylhydroquinone) and dl-a-tocopherol at the weight ratio of 0.05, 0.2 and 0.5%, respectively and laminated with nylon. TBHQ and tocopherol contents in the PE/nylon film were analyzed and the antioxidative effects of film were investigated on the lipid oxidation of semi-dried squid during storage at 5℃ and l5℃. TBHQ contents of TAP 1(TBHQ 0.05%), TAP 2(TBHQ 0.2%) and TAP 3(0.5%) were 38, 146 and 365 mg/100g, respectively. Tocopherol contents of DAP l(tocopherol 0.05%), DAP 2(tocopherol 0.2%) and DAP 3(tocopherol 0.5%) were 33, 139 and 356 mg/l00g, respectively. TBA value and POV during storage of semi-drid squid were affected both by storage temperatures and packaging films. Lipid oxidation during storage was retarded by anti-oxidative films, as TBA value of TAP 3 and DAP 3 revealed about 50% of control after storage at 5℃ for 20 days and similer effects in POV were also observed.

Comparison on the Dosimetry of TLD and PLD by Dose Area Product (DAP(Dose Area Product)를 이용한 TLD와 PLD의 선량 측정 비교)

  • Choi, Jae-Ho;Kang, Gu-Jun;Chang, Seo-Goo
    • The Journal of the Korea Contents Association
    • /
    • v.12 no.3
    • /
    • pp.244-250
    • /
    • 2012
  • The results of analyzing the difference between performances of individual dosimeters on this research subjecting the PLD and TLD, which are the official personal dosimeters, through dosimetry are as follows. After scanning the integral dose using an automatic scanner, the values of two devices that went through dose adjustment process had a statistical difference in TLD and PLD measurements under each filming conditions which were 70kVp, 200mA, 0.012sec and 42kVp, 100mA, and 0.012sec (p<0.001 and p<0.001 respectively). As for the difference of measurement value between DAP and the two particles under 70kVp, 200mA, 0.012sec filming condition, TLD had a value lower than DAP average value by $44.2mGy{\cdot}cm^2$ and PLD had a value of $246.8mGy{\cdot}cm^2$ which was lower than DAP average value by $15.5mGy{\cdot}cm^2$, while under 42kVp, 100mA, 0.012sec filming condition, TLD had a value lower than DAP average value by $17.9mGy{\cdot}cm^2$ and PLD had a value of $82.6mGy{\cdot}cm^2$ which was lower than DAP average value by 7.6$mGy{\cdot}cm^2$. Also, compared to PLD, each of 10 devices measured dose value in TLD had a larger deviation between the particles, and for a reproducibility test which repeatedly measured one particle, PLD had ${\pm}1%$ which was lower than TLD's ${\pm}2%$. As such, PLD had a superior performance result in dose measurement capacities aspect compared to TLD, and therefore we could verify that PLD is more appropriate and advantageous in managing radiation-related task performing worker's personal radiation exposure management in the diagnostic radiation field.