• Title/Summary/Keyword: Damage control scenario

Search Result 32, Processing Time 0.026 seconds

Establishment Strategics for Making a Port Specialized in Liquid Cargoes Safer - Focusing on Accident Scenario and Risk Analysis - (액체화물특화 항만의 해양환경사고 안전항만 구축방안 연구 -사고 시나리오 및 위험도 분석을 중심으로-)

  • Jung, Won-Jo;Lim, Sang-Seop;Park, Nam-Ki
    • Journal of Navigation and Port Research
    • /
    • v.46 no.3
    • /
    • pp.227-235
    • /
    • 2022
  • The purpose of this study was to analyze the risk and vulnerability of marine accidents based on statistical data on marine accidents at Ulsan Port, which has the largest amount of liquid cargo in Korea. It was found to be quite vulnerable to the risk of marine accidents, environmental damage, and vulnerability to environmental pollution accidents. Based on analysis results, marine accident scenarios and accident response strategies were prepared. Additionally, as a response strategy to prepare for large-scale marine pollution accidents at Ulsan Port, it is necessary to establish control equipment and infrastructure, as well as establish a control center to integrate marine accident safety functions. In particular, in the case of liquid cargo specialized ports such as Ulsan Port, considering the size of the cargo volume and the frequency of marine pollution accidents, it is urgent to build professional safety management institutions, which should make the port safer.

Estimation of Mega Flood Using Mega Rainfall Scenario (거대강우 시나리오를 이용한 거대홍수량 산정)

  • Han, Daegun;Kim, Deokhwan;Kim, Jungwook;Jung, Jeawon;Lee, Jongso;Kim, Hung Soo
    • Journal of Wetlands Research
    • /
    • v.21 no.spc
    • /
    • pp.90-97
    • /
    • 2019
  • In recent years, flood due to the consecutive storm events have been occurred and property damage and casualties are in increasing trend. This study calls the consecutively occurred storm events as a mega rainfall scenario and the discharge by the scenario is defined as a mega flood discharge. A mega rainfall scenario was created on the assumption that 100-year frequency rainfall events were consecutively occurred in the Gyeongancheon stream basin. The SSARR (Streamflow Synthesis and Reservoir Regulation) model was used to estimate the mega flood discharge using the scenario in the basin. In addition, in order to perform more reasonable runoff analysis, the parameters were estimated using the SCE_UA algorithm. Also, the calibration and verification were performed using the objective functions of the weighted sum of squared of residual(WSSR), which is advantageous for the peak discharge simulation and sum of squared of residual(SSR). As a result, the mega flood discharge due to the continuous occurrence of 100-year frequency rainfall events in the Gyeongan Stream Basin was estimated to be 4,802㎥/s, and the flood discharge due to the 100-year frequency single rainfall event estimated by "the Master Plan for the Gyeongancheon Stream Improvement" (2011) was 3,810㎥/s. Therefore, the mega flood discharge was found to increase about 992㎥/s more than the single flood event. The results of this study can be used as a basic data for Comprehensive Flood Control Plan of the Gyeongan Stream basin.

Conceptual Design of Mechanical System for Recovery of Seabed-Deposited Hazardous and Noxious Substances Based on Performance Requirements (해저침적 HNS 회수용 기계장치의 성능요건 기반 개념설계)

  • Hwang, Ho-Jin
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.26 no.6
    • /
    • pp.689-697
    • /
    • 2020
  • Hazardous and noxious substances (HNS) may cause maritime incidents during marine transportation, which are liable to lead to a large amount of spillage or discharge into the sea. The damage to the marine environment caused by the HNS spill or discharge is known to be much greater than the damage caused by oil spill. Particularly dangerous is HNS, which is deposited or buried in the seabed, as it can damage the organisms that live on, in, and near the bottom of the sea, the so-called "benthos," forming the benthic ecosystem. Therefore, it is vital that the HNS deposited on the seabed be recovered. In order to do so, procedures and equipment are required for accurate detection, stabilization treatment, and recovery of HNS in subsea sediment. Thus, when developing a mechanical recovery system, the performance requirements should be selected using performance indices, and the conceptual design of the mechanical recovery system should be based on performance requirements decided upon and selected in advance. Therefore, this study was conducted to arrive at a conceptual design for a mechanical recovery system for the recovery of HNS deposited on the seabed. In the design of the system, based on the fundamental scenario, the method of suction foundation with the function of self enclosing was adopted for recovering the HNS sediment in the subsea sediment. The mechanical recovery system comprises the suction foundation, pollution prevention, a pump system, control system, monitoring device, location information device, transfer device, and tanks. This conceptual design is expected to be reflected and used in the basic design of the components and shapes of the mechanical recovery system.

Risk Analysis of Ammonia Leak in the Refrigeration Manufacturing Facilities (냉동제조 시설의 암모니아 누출사고 위험 분석)

  • Kang, Su-Jin;Lee, Ik-Mo;Moon, Jin-Young;Chon, Young-Woo
    • Journal of the Korean Institute of Gas
    • /
    • v.21 no.1
    • /
    • pp.43-51
    • /
    • 2017
  • Recently, ammonia leak occurred frequently in the domestic refrigeration manufacturing facilities. Ammonia caused great damage to the environment and human health in the event of an accident as combustible gases and toxic gases. After considering the types of ammonia accidents of domestic refrigeration manufacturing facilities and selected accident scenarios and to analyze the risk analysis through Impact range estimates and frequency analysis and there was a need to establish measures to minimize accident damage. In this study, depending on the method of analysis quantitative risk assessment we analyzed the risk of the receiver tank of ammonia system. Scenario analysis conditions were set according to the 'Technical guidelines for the selection of accident scenario' under the chemicals control act and 'Guidelines for chemical process quantitative risk analysis' of center for chemical process safety. The risk estimates were utilized for consequence analysis and frequency analysis by SAFETI program of DNV, event tree analysis methodology and part count methodology. The individual risk of ammonia system was derived as 7.71E-04 / yr, social risk were derived as 1.17E-03 / yr. The derived risk was confirmed to apply as low as reasonably practicable of the national fire protection association and through risk calculation, it can be used as a way to minimize accidents ammonia leakage accident damage.

Fin failure diagnosis for non-linear supersonic air vehicle based on inertial sensors

  • Ashrafifar, Asghar;Jegarkandi, Mohsen Fathi
    • Advances in aircraft and spacecraft science
    • /
    • v.7 no.1
    • /
    • pp.1-17
    • /
    • 2020
  • In this paper, a new model-based Fault Detection and Diagnosis (FDD) method for an agile supersonic flight vehicle is presented. A nonlinear model, controlled by a classical closed loop controller and proportional navigation guidance in interception scenario, describes the behavior of the vehicle. The proposed FDD method employs the Inertial Navigation System (INS) data and nonlinear dynamic model of the vehicle to inform fins damage to the controller before leading to an undesired performance or mission failure. Broken, burnt, unactuated or not opened control surfaces cause a drastic change in aerodynamic coefficients and consequently in the dynamic model. Therefore, in addition to the changes in the control forces and moments, system dynamics will change too, leading to the failure detection process being encountered with difficulty. To this purpose, an equivalent aerodynamic model is proposed to express the dynamics of the vehicle, and the health of each fin is monitored by the value of a parameter which is estimated using an adaptive robust filter. The proposed method detects and isolates fins damages in a few seconds with good accuracy.

An Application of the Water Mist System for Underground Utility Tunnel (지하구 미분무수 소화설비 적용에 관한 연구)

  • 김운형;김종훈;박승민;김태수;민인홍;전동일;김상욱
    • Fire Science and Engineering
    • /
    • v.16 no.1
    • /
    • pp.66-76
    • /
    • 2002
  • This paper includes new nozzle design, basic design factors of water mist system that minimize a thermal damage of cable causing business interruption and applying underground utility tunnel. A underground concrete structure (2.5 m(H)$\times$2.5 m(W)$\times$25 m(D)) is constructed in order to test a nozzle performance. Under the designing fire scenario, critical thermal damage of cable sheath ($400^{\circ}c$) reached within a 2 minutes with unsuppressed fire, but type 1 nozzle (SMD 470 $\mu{m}$) and type 2 nozzle (SMD 650 $\mu{m}$) control cable temperature below $400^{\circ}c$. A system performance and fundamental design factors; K factor, flow rate, spray angle, size distribution, nozzle pressure, spray density are analyzed and proposed for system optimization.

An Experimental Study on the Thermal Property of Concrete under the Load Ratio Condition in Fire (고온화재조건 콘크리트 라이닝의 하중비에 따른 폭렬영향성 및 화재손상특성에 관한 실험적 연구)

  • Kim, Hyung-Jun;Kim, Heung-Youl;Park, Kyung-Hun;Ahn, Chan-Sol;Kwon, Ki-Hyuk
    • Fire Science and Engineering
    • /
    • v.24 no.3
    • /
    • pp.145-151
    • /
    • 2010
  • The fire in tunnel, when failed to extinguish at early stage, tends to easily develop to high temperature and spread to entire area of the tunnel because of considerable level of fire load and smoke control facility within the tunnel, resulting in severe damage to the people and tunnel structure. This study was intended to carry out the fire test with MHC fire curve, a scenario, which has the most rapid fire rise, on assumption of load ratio of 1, 20, 40, 60 and 70%, so as to identify the thermal characteristics of the concrete against spalling and the range of fire damage. The specimen was small scale sample as defined by EFNARC and the mixing ratio was based on 24 MPa, which is considered to be the normal strength. As a result of test, 16mm spalling was occurred on the lining under the non-load condition, while no spalling was occurred with 20% and 40% of load ratio. In case of 60% of load ratio, 24 mm of spalling was occurred and it failed in 10 minutes after heating in case of 70% load condition.

Predicting and Preventing Damages from Gas Leaks at LPG Stations (LPG 충전소의 가스누출에 따른 피해예측 및 감소방안)

  • YANG-HO YANG;HA-SUNG KONG
    • The Journal of the Convergence on Culture Technology
    • /
    • v.9 no.4
    • /
    • pp.577-585
    • /
    • 2023
  • This study applied ALOHA Program to predict the damage caused by fire and explosion predicted to occur from gas leakage at LPG stations and presented plans to prevent damages by diagramming the impact range and distance. The propane gas leakage from LPG stations causes human damage like breathing issues and property damage, including building destruction to residents in the surrounding areas. As a way to reduce this, first, the hazardous substance safety manager of the LPG station needs to check frequently whether the meters and safety valves are working properly to prevent leakage in advance. Second, the LPG stations' storage tanks should be worked by the person who received "hazardous substance safety manager training" under the provisions of the Act on the Safety Control of Hazardous Substances and has been appointed as a "hazardous substance safety manager" by the fire department. Third, LPG station's various safety device functions, such as overfill prevention devices, must be checked on a regular basis. Finally, wearing work clothes and shoes that prevent static electricity at LPG stations is highly recommended, as static can cause a fire when gas leaks.

Advanced Time-Cost Trade-Off Model using Mixed Integer Programming (혼합정수 프로그래밍 기법을 이용한 진보된 Time-Cost Trade-Off Model)

  • Kwon, Obin;Lee, Seunghyun;Son, Jaeho
    • Korean Journal of Construction Engineering and Management
    • /
    • v.16 no.6
    • /
    • pp.53-62
    • /
    • 2015
  • Time-Cost Trade-Off (TCTO) model is an important model in the construction project planning and control area. Two types of Existing TCTO model, continuous and discrete TCTO model, have been developed by researchers. However, Using only one type of model has a limitation to represent a realistic crash scenario of activities in the project. Thus, this paper presents a comprehensive TCTO model that combines a continuous and discrete model. Additional advanced features for non-linear relationship, incentive, and liquidated damage are included in the TCTO model. These features make the proposed model more applicable to the construction project. One CPM network with 6 activities is used to explain the proposed model. The model found an optimal schedule for the example to satisfy all the constraints. The results show that new model can represent more flexible crash scenario in TCTO model.

FAIR-Based BIA for Ransomware Attacks in Financial Industry (금융 산업에서 발생하는 랜섬웨어 공격에 대한 FAIR 기반의 손실 측정 모델 분석)

  • Yoon, Hyun-sik;Song, Kyung-hwan;Lee, Kyung-Ho
    • Journal of the Korea Institute of Information Security & Cryptology
    • /
    • v.27 no.4
    • /
    • pp.873-883
    • /
    • 2017
  • As Ransomware spreads, the target of the attack shifted from a single personal to organizations which lead attackers to be more intelligent and systematic. Thus, Ransomware's threats to domestic infrastructure, including the financial industry, have grown to a level that cannot be ignored. As a measure against these security issues, organizations use ISMS, which is an information protection management system. However, it is difficult for management to make decisions on the loss done by the security issues since amount of the damage done can not be calculated with just ISMS. In this paper, through FAIR-based loss measurement model based on scenario's to identify the extent of damage and calculate the reasonable damages which has been considered to be the problem of the ISMS, we identified losses and risks of Ransomeware on the financial industry and method to reduce the loss by applying the current ISMS and ISO 27001 control items rather than modifying the ISMS.