• Title/Summary/Keyword: DR image

Search Result 161, Processing Time 0.028 seconds

The Study on Actual Conditions done and the Image Quality of UGI (위 X선촬영 실태에 관한 조사 연구)

  • Lee, Sun-Sook;Huh, Joon;Kim, Sung-Soo
    • Journal of radiological science and technology
    • /
    • v.20 no.1
    • /
    • pp.39-42
    • /
    • 1997
  • This study was done at 45 medical facilities located in Seoul. The purpose of study is twofold. First, this is to investigate usually who extmines patients for UGI and how many films are used for the examination. Secondly, this is to evaluate image qualities of UGI in terms of representation of lesser curvatures, amount of Ba and air and other criteria for the exam. The results are as follows : 1. In most cases, the UGI is examined by the Dr(67%), by the RT(22%), and together(11%). 2. The total films used ranged from 5 sheets(42%) to 7 sheets(18%). 3. The amount of Ba given to Pt. was mostly $200{\sim}300\;ml$(60%) and gastrografin was used $3{\sim}4\;g$(86.6%) for the examination. 4. For the evaluation of qualities, lack of representation of lesser curvature was 86.7%, lack of Ba and air and bubble formation was 62%, 46.7% and 42.2% respectively.

  • PDF

Side Scan Sonar based Pose-graph SLAM (사이드 스캔 소나 기반 Pose-graph SLAM)

  • Gwon, Dae-Hyeon;Kim, Joowan;Kim, Moon Hwan;Park, Ho Gyu;Kim, Tae Yeong;Kim, Ayoung
    • The Journal of Korea Robotics Society
    • /
    • v.12 no.4
    • /
    • pp.385-394
    • /
    • 2017
  • Side scanning sonar (SSS) provides valuable information for robot navigation. However using the side scanning sonar images in the navigation was not fully studied. In this paper, we use range data, and side scanning sonar images from UnderWater Simulator (UWSim) and propose measurement models in a feature based simultaneous localization and mapping (SLAM) framework. The range data is obtained by echosounder and sidescanning sonar images from side scan sonar module for UWSim. For the feature, we used the A-KAZE feature for the SSS image matching and adjusting the relative robot pose by SSS bundle adjustment (BA) with Ceres solver. We use BA for the loop closure constraint of pose-graph SLAM. We used the Incremental Smoothing and Mapping (iSAM) to optimize the graph. The optimized trajectory was compared against the dead reckoning (DR).

Radiological Measurements of Lung Field Size in Normal Korean using Digital Chest Posteroanterior Radiography (디지털 흉부 후·전 방향 방사선영상을 이용한 정상 한국인 폐 크기의 영상의학적 계측)

  • Park, Yeo-Jin;Joo, Young-Cheol;Lee, Il-Soo
    • Journal of radiological science and technology
    • /
    • v.41 no.1
    • /
    • pp.1-6
    • /
    • 2018
  • The purpose of this study is to provide baseline data on lung field size measured radiological method by chest PA image in normal Korean. The subject of this study is 496 normal persons who performed chest PA examination using x-ray digital radiography system. The measurement method is from the apex of right and left lung to the costophrenic angle of both lung, from the top of the image to the lowest costophrenic angle of both lung and transverse line of the largest lung area. As a result of this study, the following conclusions were obtained. A lung field size of male is larger than the female(p<0.05). The younger the age, the longer both lung length and total lung height statistically significant. As a increase height and length, A lung field size was increased(p<0.05). But, BMI is not associated with a lung field size. This study will be data of reference data when radiological technologists perform chest PA examination.

The Effects of Total Variation (TV) Technique for Noise Reduction in Radio-Magnetic X-ray Image: Quantitative Study

  • Seo, Kanghyen;Kim, Seung Hun;Kang, Seong Hyeon;Park, Jongwoon;Lee, Chang Lae;Lee, Youngjin
    • Journal of Magnetics
    • /
    • v.21 no.4
    • /
    • pp.593-598
    • /
    • 2016
  • In order to reduce the amount of noise component in X-ray imaging system, various reduction techniques were frequently used in the field of diagnostic imaging. Although the previous techniques -such as median, Wiener filters and Anscombe noise reduction technique - were able to reduce the noise, the edge information was still damaged. In order to cope with this problem, total variation (TV) noise reduction technique has been developed and researched. The purpose of this study was to evaluate and compare the image quality using normalized noise power spectrum (NNPS) and contrast-to-noise ratio (CNR) through simulations and experiments with respect to the above-mentioned noise reduction techniques. As a result, not only lowest NNPS value but also highest CNR values were acquired using a TV noise reduction technique. In conclusion, the results demonstrated that TV noise reduction technique is proved as the most practical method to ensure accurate denoising in X-ray imaging system.

Image System Using Dual Energy Detector (이중 에너지 검출기를 이용한 영상 시스템)

  • Yeo, Hwa-Yeon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.11 no.9
    • /
    • pp.3517-3523
    • /
    • 2010
  • Single exposure dual X-ray imaging can be used to separate soft and dense-material images for medical and industrial applications. This study keep focusing baggage inspection system(BIS) specifically. New detector modules for single exposure dual X-ray imaging are consisted of low energy detector (LED) and high energy detector (HED). First, the optimized thickness of copper filter coupled HED to separate low energy and high energy was simulated by the given X-ray energy (140 kVp, 1 mA) using Monte Carlo simulation codes, MCNPX. So as a result of simulation, the copper filter thickness is 0.7 mm. For the design of PIN photodiode, ATLAS device simulation tool was used. 16 channels PIN photodiode of 1.5 mm ${\times}$ 3.2 mm for Dual X-ray imaging detector was fabricated in the process of ETRI. And its dark current and quantum efficiency, terminal capacitance were measured. It was proven that the Lanex Fast B coupled HED were a sufficient candidate to replace the CsI(Tl) commerced in dual X-ray system, since these give a strong signal, overcoming system noise. Finally dual X-ray image was acquired through correction of the LED X-ray Image and the HED X-ray Image.

RNSXI(real-name shooting X-ray of inspector) Settlement Realization applying PACS Database, In Digital Medical environment (PACS Database를 활용한 촬영실명제 정착화 실현)

  • Kang, Ji-Youn;Lee, Lae-Gon;Kang, Doo-Hee;Lee, Hwa-Sun;Hwang, Sun-Gwang
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.9 no.2
    • /
    • pp.5-9
    • /
    • 2007
  • As developing the medical treatment image portion with the change of these times, PACS, which is able to digitalize image portion data, has a lot of data-based image data. Applying this PACS, we would like to settle down RNSXI(real-name shooting X -ray of inspector) system. We interviewed with P ACS's operators of university hospitals which is using PACS in Seoul about the present conditions whether using of RNSXI or not. And we inquired the RNSXI equipments, applying PACS database, and Interface conditions undertook to do in our hospital. All university hospitals in Seoul are set up the P ACS system. But no hospital use the RNSXI. In our hospital, we can check inspector' name or initials who exposure x-ray with the PACS Viewer by looking over equipments(CR, DR, US, MG, MR, CT) and Interface of the DICOM Header data. However, some equipments like RF and Angio can not check inspector' name or initials. Under the Film/System environment, RNSXI system has been used frequently like that inspector's signature or initial added to a patient data. Though the digital medical treatment was developed, RNSXI system was declined. It is necessary to using RNSXI system in order to improving radiologists' rights, even if it is not under the application of the medical treatment image laws. If RNSXI system use, radiologists should specialize in their major and the Repeat rate should be reduced. In environment of PACS, RNSXI system can be used by linking both the equipments and the Interface with a production enterprise of P ACS. Therefore RNSXI system applying the P ACS datebase should settle down in our medical system for being provided lots of data.

  • PDF

Convergence of the Image Evaluation by BI-RADS Classification in Accordance with Algorithms in DR Mammography (디지털 유방촬영술에서 BI-RADS의 구분에 따른 알고리즘별 영상의 융복합적 평가)

  • Lee, Mi-Hwa
    • Journal of Digital Convergence
    • /
    • v.13 no.9
    • /
    • pp.489-495
    • /
    • 2015
  • Image availability evaluated by the degree of agreement and sensitive using the process improve visualization according to the Algorithm modification in Image Post-Processing. Reliability measured by the Breast Imaging Reporting and Data System. 172 patients visit same period divided by BI-RADS, category five stages, and contents of breast parenchyma into Calcification, Nodule and Mass. Evaluated the TE/PV image reliability, visualization sensitive, agreement of diagnosis. Convergence analysis was an in various fields. According to the result of this research, PV has higher sensitive and accuracy about lesions than TE visual and there is a difference insensitive by contents of breast parenchyma. Therefore, practical use of Algorithm Modification(Tissue Equalization: TE, Premium View: PV) is expected to improve more accurate, useful diagnosis, which has not been easy until now.

Decreased of Patient Dose by Built-in Filter in Pelvis A-P Projection (골반촬영 시 내장된 필터를 이용한 환자선량 감소)

  • Shin, Seong-Gyu
    • The Journal of the Korea Contents Association
    • /
    • v.12 no.8
    • /
    • pp.233-239
    • /
    • 2012
  • This study was performed to find a method to decrease the radiation exposure of patients when obtaining anteroposterior pelvic images maintaining the quality of the image by using the copper filter built in the DR equipment now being used in our hospital. We measured the level of radiation by changing the filters from none filter to 0.1mmCu, 0.2mmCu, and 0.3mmCu and detected the organ level of radiation by PCXMC program. As a result, high levels of radiation were detected in the bladders and testicles and the levels were decreased as the thickness of the filter was increased and the amount of decrease was the highest in 0.1mmCu. And we asked for the expert opinions to 3 radiologists and as a result, only images obtained by 0.1mmCu filter out of all the images on which copper filters were used were accepted as the ones with diagnostic value same as none filter. At this time, the incident dose on the pelvic region was 0.895mGy which was smaller than the one in none filter by 47%. Therefore, using 0.1mmCu when obtaining anteroposterior pelvic images can effectively decrease the radiation exposure of patients.

Social Reflection of Director Choi Donghoon -based on the Theory of Carnival of Mikhail M. Bakhtin (최동훈 영화의 사회반영성 -바흐친의 카니발 이론을 중심으로-)

  • Lee, Minho;Yi, Hyoin
    • The Journal of the Korea Contents Association
    • /
    • v.13 no.6
    • /
    • pp.125-136
    • /
    • 2013
  • Director Choi Donghoon is the most famous director in Korea as a box office successor, especially (2102) has gained No. 1 box office attraction in Korean film history. However some critics have criticised the works of Dr. Choi because of their plebeianness. This paper focused on the reason of interaction with audiences through the theory of carnival of Mikhail M. Bakhtin. Because the theory of carnival is not only the adapted method to account for the power of popular culture to M. Baktin but also the useful method to understand the keys of interaction of Dr. Choi's films. It's not difficult to find the esthetic elements of carnival theory example for 'dethronement & coronation', 'overturn & ridicule', 'image of feast', 'language of square' in the films of Choi which are The Big Swindle(2004), Tazza: The High Rollers(2006), Woochi(2009), The Thieves(2012). Therefore this paper has endeavored that the box office attraction and success of communication with audiences is due to the realistic attitude and social reflection of Choi's films.

Evaluation of Usefulness of Automatic Exposure Control (AEC) by Comparison Analysis of Entrance Surface Dose (ESD) and Entropy in Clinical Application of Digital Radiography (DR) (디지털 방사선 시스템의 노출 유형에 따른 임상 적용 시 입사표면선량 및 Entropy 비교분석을 통한 자동노출제어장치의 유용성 평가)

  • Choi, Ji-An;Hwang, Jun-Ho;Lee, Kyung-Bae
    • The Journal of the Korea Contents Association
    • /
    • v.19 no.8
    • /
    • pp.276-283
    • /
    • 2019
  • The purpose of this study is to evaluate the usefulness of automatic exposure control (AEC) by analyzing entrance surface dose (ESD) and entropy on using automatic exposure and manual exposure. The experimental method was to measure the dose by placing a semiconductor dosimeter on the Rando Phantom for the Pelvis, Abdomen, Skull, and Chest regions. The DICOM file was simultaneously acquired and then entropy was analyzed by using Matlab. As a result, when using the automatic exposure control, dose of all sites was lower than manual exposure's dose and entropy was high. In addition, paired t-test was performed for each item and p<0.05 was found in each item. In conclusion, the use of automatic exposure control can be a useful method to contribute to the optimization of the exposure dose and the image quality by reducing the amount of unnecessary radiation amount and information loss that can occur in X-ray examination.