• Title/Summary/Keyword: DLC (Diamond-like Carbon)

Search Result 318, Processing Time 0.032 seconds

Characteristic of Nitrogen doped Diamond-Like Carbon film on the Silicon substrates (실리콘 기판에 증착된 질소도핑 DLC 박막의 특성)

  • Nguyen, Van Cao;Kim, Tae Hyeon;Kim, Hye Sung;Shin, Dong Chul;Kim, Tae Gyu
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.12 no.2
    • /
    • pp.34-40
    • /
    • 2013
  • Various depositional conditions, such as substrate, pressure, deposition time, temperature of substrate, power and gas composition, have mainly been studied to attain DLC films using RF sputtering system up to the current. In this study, the $N_2/Ar/CH_4$ gas mixture factored on characteristics of DLC deposited film such as structure, hardness, electrical property were investigated. The concentration of the $N_2$ gas in the sputtering gas may be a significant effect on the growth rate of the doped films, because nitrogen ions react not only with the carbon atoms on the target but also with $C_xH_y$ ions in the plasma on the substrate surface. It was seen from this experimental that the resistance of deposited film is decreased, and the relative intensity ratio of D to G peak is increased as nitrogen content of film deposition is increased.

THE INFLUENCE OF ABUTMENT SCREW TIGHTENING TIMING AND DLC COATING OF CONICAL CONNECTION IMPLANT SYSTEM (일체형 지대주의 Diamond Like Carbon 표면 처리와 나사 조임 시기가 풀림 현상에 미치는 영향)

  • Kim, Ki-Hong;Koak, Jai-Young;Heo, Seong-Joo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.46 no.2
    • /
    • pp.209-216
    • /
    • 2008
  • Statement of problem: It is difficult about assessing the loosening tendency of conical connection type implant after cyclic loading with diamond like carbon coating one-piece abutments, and also about the retightening effect. Purpose: This study was performed to investigate the influence of one-piece abutment screw retightening after $5.0{\times}10^{4}$ cyclic loading and Diamond like coating Material and methods: Thirty two ITI implant were divided to 4 groups. Group 1,3-titanium abutment, group 2,4 - diamond like carbon coated abutment. Group 1,2 - $20.0{\times}10^{4}$ cyclic loading after $5.0{\times}10^{4}$ cyclic loading, Group 3,4- after $20.0{\times}10^{4}$ Cyclic loading. After cyclic loading, periotest values were taken and removal torque values of abutments were measured with a digital torque gauge. Results: 1. The removal torque of group 2 after $5.0{\times}10^{4}$ cyclic loading is slightly greater than the other groups but not significantly higher than others (P>0.05). 2. The final removal torque values after $20.0{\times}10^{4}$ cyclic loading of group 1 is bigger than group 3, and group 2 is bigger than group 4, but not significantly higher (P>0.05). 3. The final removal torque values after $20.0{\times}10^{4}$ cyclic loading of all groups are not significantly different (P>0.05).

Filtered Vacuum Arc Source의 Plasma Duct-Bias 변화에 다른 막 물성 연구

  • Gang, Yong-Jin;Jang, Yeong-Jun;Kim, Jong-Guk
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2016.02a
    • /
    • pp.170.2-170.2
    • /
    • 2016
  • DLC(Diamond like Carbon)는 Diamond와 유사한 물리화학적 특성을 보유한 막으로 고경도 및 우수한 내마모성, 화학적 안정성의 특성을 가지고 있다. DLC는 크게 카본의 막 형성 공정에서 카본 소스에 따라 수소가 포함된 DLC와 무수소DLC로 구분된다. Tetrahedral amorphous carbon (ta-C) 박막은 DLC 박막 중에서 가장 다이아몬드와 유사한 특성을 가지는 박막으로, a:C-H에 비해 높은 열적안정성, 경도(50~60 GPa) 및 내마모 특성이 우수하여, 현재 다양한 응용분야에 적용하고 있다. 본 연구에서는 무수소 DLC 형성을 위해 자장필터가 장착된 Filtered Vacuum Arc Source(FVAS)를 자체적으로 개발하여 연구를 진행하였다. FVAS 장비는 카본 이온 발생부와 Plasma Duct 부위, 전자석부위 구성되어 있으며, 본 연구에서는 Plasma Duct 부위의 Bias 제어를 통해 음극에서 기판으로 이동하는 카본이온의 에너지와 flux 변화를 통한 박막 증착 거동 및 물성 연구를 진행하였다. Plasma Duct Bias 변화는 각 0, 5, 10, 15, 20 V 조건으로 진행하였으며, 물성 평가는 경도(Hardness), 마찰계수, 응력(Stress), 전기전도 특성에 대한 분석을 진행하였다. 박막의 증착 거동에서는 Plasma Duct bias 변화에 따라10 V에서 가장 높은 증착 거동을 가지다 감소하는 경향을 확인 하였으며, 박막의 물성 특성 평가 시에도 이와 유사하게 특성의 차이를 관찰하였다. 이는 음극부위에서 형성된 카본이온이 기판에 도달 시에 Plasma Duct Bias 변화에 따라 이온의 Flux 및 에너지 변화로 인해 박막의 밀도 및 ta-C 막의 물성 변화로 예상되며, 이를 분석하기 위해 라만분석 및 기판 도달 에너지 분석을 진행하였다

  • PDF

Structure and Mechanical Properties of Si Incorporated Diamond-like Carbon Films Prepared by PACVD

  • Kim, Myoung-Geun;Park, Jun-Youp;Lee, Kwang-Ryeol;Eun, Kwang-Yong
    • The Korean Journal of Ceramics
    • /
    • v.3 no.2
    • /
    • pp.101-104
    • /
    • 1997
  • Although tribological behavior of Si incorporated DLC films have been intensely investigated, their mechanical properties were not consistent among previous publications. The present work reported the structural change by adding Si, and their effects on the mechanical properties. Si incoporated DLC films were deposited using mixtures of benzene and diluted silane with hydrogen of various volume fractions. We could obtain the films of $X_{si}$ (defined by the Si fraction without considering hydrogen) ranging from 0.01 to 0.21, and found that the mechanical properties of the films changed significantly in the range less than $X_{si}=0.06$. In this range, the hardness and stress increased with Xsi. For higher content of Si, the hardness and stress showed saturated behavior with $X_{si}$. This behavior was discussed in terms of the changes in atomic bond structures.

  • PDF

Physical Properties of Diamond-like Carbon Thin Films Prepared by a Microwave Plasma-Enhanced Chemical Vapor Deposition (마이크로웨이브 화학기상증착법으로 성장된 다이아몬드상 카본박막의 물리적인 특성연구)

  • Choi, Won-Seok;Hong, Byung-You
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2003.07b
    • /
    • pp.791-794
    • /
    • 2003
  • DLC thin films were prepared by microwave plasma-enhanced chemical vapor deposition method on silicon substrates using methane ($CH_4$) and hydrogen ($H_2$) gas mixture. The negative DC bias ($-450V{\sim}-550V$) was applied to enhance the adhesion between the film and the substrate. The films were characterized by Raman spectrometer. The surface morphology was observed by an atomic force microscope (AFM). And also, the friction coefficients were investigated by AFM in friction force microscope (FFM) mode, which were compared with the pin-on-disc (POD) measurement.

  • PDF

Physical Properties of Diamond-like Carbon Thin Films Prepared by a Microwave Plasma-Enhanced Chemical Vapor Deposition (마이크로웨이브 화학기상증착법으로 성장된 다이아몬드상 카본박막의 물리적인 특성연구)

  • Choi, Won-Seok;Hong, Byung-You
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2003.07b
    • /
    • pp.842-845
    • /
    • 2003
  • DLC thin films were prepared by microwave plasma-enhanced chemical vapor deposition method on silicon substrates using methane ($CH_4$) and hydrogen ($H_2$) gas mixture. The negative DC bias ($-450V{\sim}-550V$) was applied to enhance the adhesion between the film and the substrate. The films were characterized by Raman spectrometer. The surface morphology was observed by an atomic force microscope (AFM). And also, the friction coefficients were investigated by AFM in friction force microscope (FFM) mode, which were compared with the pin-on-disc (POD) measurement.

  • PDF

Deposition of hard coatings on polycarbonate substrate by high frequency ion beam

  • Kim, Sung-Ryong;Song, Jun-Seob;Choi, Young-Joon;Kim, Jong-Hun
    • Journal of Korean Vacuum Science & Technology
    • /
    • v.2 no.2
    • /
    • pp.101-106
    • /
    • 1998
  • The poor wear and scratch properties of polycarbonate have limited its application in many fields. In order to improve the wear and scratch properties of polycarbonate we have deposited diamond like carbon (DLC) coatings. The diamond like carbon coatings were made using a high frequency ion beam gun by introducing H2 and CH4 gases. The coatings were characterized with Raman spectroscopy, scanning electron microscope, ellipsometer, microscratch tester and hazemeter. Polymeric hard coating was applied onto the polycarbonate substrate before depositing a DLC coating to investigate the effect of interlayer on the system's failure mode.

  • PDF

Field emission from diamond-like carbon films studied by scanning anode

  • Ahn, S.H.;Jeon, D.;Lee, K.-R.
    • Journal of Korean Vacuum Science & Technology
    • /
    • v.3 no.1
    • /
    • pp.54-58
    • /
    • 1999
  • We deposited diamond-like carbon (DLC) films using ion beam sputtering of a graphite target on flat substrates for use as a thin film field emitter. An n-type silicon wafer, titanium-coated silicon, and indium tin oxide (ITO) coated glass were used as a substrate. All films exhibited a sudden increase in the emission after a breakdown occurred at high voltage. The morphology of the films after the breakdown depended on the substrate. On ITO and Ti substrates, the DLC film peeled off upon breakdown, but on the Si substrate the surface melting due to breakdown resulted in the formation of various structures such as a sharp point, mound, and crater. By scanning the deformed surface with a tip anode, we found that the emission was concentrated at the deformed sites, indicating that the field enhancement due to the morphology change was responsible for the increased emission.

  • PDF

A Study on XPS and XRR Characteristics of DLC films Deposited by FCVA Method (FCVA 방법으로 증착된 다이아몬드상 탄소 박막의 XPS 및 XRR 특성 연구)

  • 박창균;장석모;엄현석;서수형;박진석
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.52 no.3
    • /
    • pp.109-115
    • /
    • 2003
  • Diamond-like carbon (DLC) films are deposited at room temperature using a filtered cathodic vacuum arc (FCVA) technique. The influence of negative bias voltage (applied to the substrate from 0 to -250V) on the $sp^3$ hybridized carbon fraction is examined by Raman spectroscopy and x-ray photoelectron spectroscopy (XPS) for C 1s core peak. For the first time, depth profile of C 1s, Si 2p, and O 1s XPS peaks for the deposited DLC film are obtained. DLC film is modeled as a multilayered structure. composing of surface, bulk, and interface. In addition, the x-ray reflectivity (XRR) is proposed as a method for estimating the density, surface roughness, and thickness of each layer constituting the DLC film. The estimated thickness of DLC film is in good agreement with the result obtained from the transmission electron microscope (TEM) measurement.

Effect of environment on the tribological behavior of Si-incorporated diamond-like carbon films (실리콘이 첨가된 다이아몬드상 카본 필름의 트라이볼로지적 특성에 미치는 환경변화의 영향)

  • 양승호;공호성;이광렬;박세준;김대은
    • Proceedings of the Korean Society of Tribologists and Lubrication Engineers Conference
    • /
    • 1999.11a
    • /
    • pp.42-48
    • /
    • 1999
  • An experimental study was performed to discover the effect of environment on the tribological behavior of Si-incorporated diamond-like carbon(Si-DLC) film slid on a steel ball. The films were deposited on Si(100) wafers from radio-frequency glow discharge of mixtures of benzene and dilute silane gases. Experiments using a ball-on-disk test-rig was performed under vacuum, dry air and ambient air conditions. It was observed that coefficient of friction was decreased as the environmental condition changes from vacuum, to dry air. It was also observed that the coefficient of friction decreased with increasing silicon concentration in the film. Chemical analyses of debris suggested that the low and stable friction coefficient is closely related to the silicon rich oxide debris and the rolling action.

  • PDF