• Title/Summary/Keyword: DIAMETER

Search Result 19,165, Processing Time 0.042 seconds

Fault Diameter of Folded Hyper-Star Interconnection Networks FHS(2n,n) (상호연결망 폴디드 하이퍼-스타 연결망 FHS(2n,n)의 고장 지름)

  • Kim, Jong-Seok;Lee, Hyeong-Ok
    • The KIPS Transactions:PartA
    • /
    • v.17A no.1
    • /
    • pp.1-8
    • /
    • 2010
  • The fault diameter is one of the important measures for transmission rate and reliability of interconnection network. H.-O. Lee et al.[Parallel paths in folded hyper-star graph, Journal of KIPS, Vol.6, No.7, pp.1756-1769, 1999] suggested the node-disjoint paths of FHS (2n,n), and proved that the fault diameter of FHS(2n,n) is less than 2n-1. In this paper, we suggest an advanced node-disjoint paths of FHS(2n,n). We also prove that the wide diameter of FHS(2n,n) is dist(U,V)+4, and the fault diameter of FHS(2n,n) is less than n+2.

Experimental study on the melting characteristics of pellet fuel for a waste plastic firing boiler (열가소성 폐플라스틱 연소 보일러용 펠렛 연료의 용융특성 실험)

  • Lee, Sung-Soo;Kim, Hyouck-Ju;Choi, Gyu-Sung
    • 한국연소학회:학술대회논문집
    • /
    • 2006.04a
    • /
    • pp.189-193
    • /
    • 2006
  • Experiments were performed to investigate the melting characteristics of pellet fuel made of LDPE and PP for a waste plastic firing boiler. Pellet fuel in a burner goes through conduction, convection and radiation transferred from flame in a furnace, and complex thermo/chemical processes. To figure out effects of ambient temperature and size of pellet on melting time pellets with a diameter from 5 mm to 40 mm were made to contact high temperature flue gas generated by a LNG firing pilot burner. Though melting processes of plastics include complicated heat transfer in a burner, parameters are limited to flue gas temperature and size for the simplicity in this study. From the results, melting times of LDPE and PP with a diameter of 5mm are 63 and 62 secs respectively at 600 $^{\circ}C$ while 677 and 583 sees respectively for a diameter of 40 mm. At $900^{\circ}C$, melting times of LDPE and PP with a diameter of 5mm are 21 and 24 sees respectively while 408 and 337 secs respectively for a diameter of 40 mm. It is found that melting time of LDPE is longer than that of PP, and melting times of both in general increase with diameter of pellets. It is thought melting is dependent mostly on melting temperature of plastic. It is expected melting times obtained from the study might be taken into account in designing a pellet firing burner for a boiler

  • PDF

A Study on the effect of welding wire diameter on the welding quality detection (용접 와이어 직경이 용접 상태 검출에 미치는 영향)

  • Ryu, Jeong Tak
    • Journal of Korea Society of Industrial Information Systems
    • /
    • v.21 no.2
    • /
    • pp.39-44
    • /
    • 2016
  • Using the welding current and voltage signal processing, we have studied the influence that the diameter of the welding wire to the welding quality detection. For the experiments, We have analyzed the signal with respect to large and small artificially a gap between base materials than the welding wire. In this experiment, the 1.2 mm diameter of the welding wire was used, and distance between the welding base materials was respectively 1.0 mm and 2.0 mm. In the welding with a large defect than the diameter of the welding wire it was able to detect a change in the welding current and welding voltage. But it could not detect a change in the welding current and welding voltage in the welding has a small defect than the welding wire diameter.

Construction of Precision Measurement Interferometer for Standard Ball Diameter (표준구직경 정밀측정 간섭계 제작)

  • Chang, Kyung-Ho;Lee, Yong-Jae;Suh, Ho-Suhng;Do, Jin-Yeol;Kang, Si-Hong
    • Journal of Sensor Science and Technology
    • /
    • v.8 no.4
    • /
    • pp.347-353
    • /
    • 1999
  • We constructed an interferometer for precise measurement of the ball diameter, and measured the diameter of steel ball with a diameter of 78 mm. The interferometer was consisted of etalon to instal ball between two parallel plates and placed on the monolithic flexure to be moved parallel. The ball diameter was calculated from phase difference of one pair of signals interfered between the both sides of ball and two parallel plates, and the signals was observed by photodetectors with scanning the etalon. The results showed that the diameter of steel ball was 78.1893544 mm and measurement uncertainty of 29 nm in confidence level of 95.5%.

  • PDF

Effect of Two Variables on the Casting Ability of Some Nonpercious Alloys for Porcelain-Metal Restorations (납형의 직경 및 소환방법이 도재-금속 보철물용 비귀금속 합금의 주조성에 미치는 영향)

  • Kim, Uoong-Chul
    • Journal of Technologic Dentistry
    • /
    • v.6 no.1
    • /
    • pp.19-26
    • /
    • 1984
  • This Experimental study was performed to study the effect of the heat soaking and the diameter of pattern on the casting ability of three nonprecious alloys manufactured for porcelain-metal restorations, with respect to their ability to reproduce test pieces by casting over a selected range of uniform diameters. Samples of total 60 were constructed and divided into 6 groups according to the two variables, the diameter and the heat soaking. The completed cast samples were examined visually and measured with a caliper calibrated to 0.05mm. The results obtained were as follows: 1. Length cast was significantly related to the diameter to be cast, especially in the case of the marrowest diameter of 230m. 2. Length cast not significantly related to the heat soaking. 3. The completeness of casting was significantly related to the diameter to be cast, particularly in the case of the narrowest diameter of 230m. 4. The completeness of casting was not significantly related to the heat soaking. 5. All of the three nonprecious alloys used for this experiment were significantly different from an ideal alloy in the completeness of casting.

  • PDF

Effect of Si content on Nugget Diameter of Electric Resistance Spot Welded Dual Phase Steel (DP강의 전기저항점용접부 너깃직경에 미치는 Si 함량의 영향)

  • Kong, Jong-Pan;Kang, Gil-Mo;Han, Tae-Kyo;Chin, Kwang-Geun;Kang, Chung-Yun
    • Journal of Welding and Joining
    • /
    • v.29 no.5
    • /
    • pp.99-105
    • /
    • 2011
  • In this study, effect of Si content on nugget diameter in electric resistance spot welded dual-phase(DP) steel was investigated. The cold rolled DP steels with different Si content (0.5, 1.0, 1.5, 2.0 wt.%) were used and thickness of those sheet was 1.2mm. With increasing Si content, nugget diameter was increased at the same welding current. This is attributed to increase of heat input result from high resistivity. Also, nugget diameter was increased with an increase in Si content for the same heat input. For this reason, the melting point of DP steel is lowered with an increase in the Si content. And solid DP steel can easily be transformed to a liquid phase because the low melting point. Finally, a prediction formula for the nugget diameter(N.D.) could be obtained in terms of heat input(Q) and melting point(M.P) as follows: N.D.(mm) = 0.11Q(J) - 0.0031 M.P.($^{\circ}C$) + 0.32.

Characteristics of Friction Stir Welded AZ31 Mg Alloys with Shoulder Diameter and Rotating Speed (숄더 지름과 회전 속도에 따른 AZ31 마그네슘합금의 마찰교반접합 특성)

  • Jun, Sang-Hyuk;Ko, Young-Bong;Park, Kyeung-Chae
    • Journal of Surface Science and Engineering
    • /
    • v.46 no.1
    • /
    • pp.36-41
    • /
    • 2013
  • Friction stir welding (FSW) is a relatively new joining technique particularly for magnesium and aluminum alloys that are difficult to fusion weld. In this study, AZ31 Mg alloys were joined by FSW with shoulder diameter 11, 19 mm and rotating speed 900, 1200, 1500, 1800 rpm. The shoulder diameter and welding speed depended on the heat input during FSW process. As a result, the microstructures of stir zone were a fine grain by dynamic recrystallization. According to the larger shoulder diameter and the higher rotating speed, refined grain sizes of stir zone were grown by higher heat input, and the microhardness of stir zone was lower. The tensile strength at the shoulder diameter 19 mm, rotating speed 900 rpm was obtained maximum value. This value compared with the base metal was over 93%.

Experimental analysis on effects of nozzle diameter on detection characteristics of an optical particle counter (광학식 입자 계수기 내 샘플 노즐 직경이 측정 효율 및 특성에 미치는 영향에 대한 실험적 연구)

  • Song, Hyunwoo;Kim, Taewook;Song, Soonho
    • Particle and aerosol research
    • /
    • v.13 no.4
    • /
    • pp.159-164
    • /
    • 2017
  • The detection efficiency and characteristics of an optical particle counter (OPC), with various sample nozzle outlet diameters, were experimentally investigated. The OPC system, which was built with original design, was made up of a diode laser, two photodetectors, and a variety of optics such as a beam splitter and a concave mirror. The cone-shaped sampling nozzle was designed to be changeable to alter the outlet diameter, within the range of 1 to 3 mm. For samples, sets of polystyrene latex (PSL) standard particle with various sizes of 1 to $3{\mu}m$, were used. As a result, detection efficiency of the OPC greatly decreased with larger nozzle outlet diameter. Moreover, increased nozzle outlet diameter means broader sample flow, thus caused light interference and multiple scattering which results in abnormal high peaks in scattered light signal. The ratio of abnormal peaks to regular signal of single particle increased with larger nozzle outlet diameter.

Synthesis of Silicon Carbide Whiskers (II): Stacking Faults (탄화규소 휘스커의 (II): 적층결함)

  • 최헌진;이준근
    • Journal of the Korean Ceramic Society
    • /
    • v.36 no.1
    • /
    • pp.36-42
    • /
    • 1999
  • Stacking faults in SiC whiskers grown by three different growth mechanisms; vapor-solid(VS), two-stage growth(TS), and vapor-liquid-solid (VLS) mechanism in the carbothermal reduction system were investigated by X-ray diffraction(XRD) and transmission electron microscopy (TEM). The content of stacking faults in SiC whiskers increased with decreasing the diameter of whiskers, i.e., the small diameter whiskers (<1 $\mu\textrm{m}$) grown by the VS, TS, and VLS mechanisms have heavy stacking faults whereas the large diameter whiskers(>2$\mu\textrm{m}$) grown by the VLS mechanism have little stacking faults. Heavy stacking faults of small diameter whiskers was probably due to the high specific lateral surface area of small diameter whiskers.

  • PDF

Study on the Flow Characteristics of R-22, R-l34a in Small Diameter Tubes (R-22 및 R-134a의 세관 내 유동 특성에 관한 연구)

  • 홍진우;정재천;장승환;권옥배;오후규
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.14 no.9
    • /
    • pp.756-765
    • /
    • 2002
  • Experimental work was performed on the flow characteristics of R-22 and R-l34a in small diameter tubes. The experimental apparatus was made up of liquid pump, pre-heater, sight-glass, condenser and measurement instruments. The sight-glass for flow pattern observations was located at the outlet of the pre-heater. The experiment was carried out to show the flow characteristics of R-22 and R-l34a. Data were taken with test conditions in the following ranges; the mass flux was ranged from 100 to 1,000 kg/$m^2s$, the saturation temperature was $30^{\circ}C$ and the vapor quality was ranged from 0.1 to 0.9. The main results were summarized as follows; In the flow patterns during evaporation, the annular flow in a 2 mm inner diameter tube occurred at a relatively lower quality and mass velocity, compared to the flow in a 8mm inner diameter tube. The evaporation flow in small diameter tubes has been shown major deviations with the Mandhane, Taitel-Dukler's and Wambs-ganss' flow pattern maps but it was similar to the Dobson's flow pattern map.