A STUDY ON DEVELOPMENT AND PHYSICAL PROPERTIES OF STAINLESS STEEL ORTHODONTIC WIRES MADE IN KOREA (국산(國産)스테인레스강선계(鋼線系) 교정용선재(矯正用線材)의 개발(開發)과 물리적(物理的) 성질(性質)에 관(關)한 연구(硏究))

  • Sung, Jae-Hyun;Kwon, Oh-Won;Kyung, Hee-Moon;Lee, Kee-Dae
    • The korean journal of orthodontics
    • /
    • v.19 no.2
    • /
    • pp.7-24
    • /
    • 1989
  • The physical properties of seven sizes of control groups and experimental group in stainless steel orthodontic wires were studied in tension, hardness, bending, torsion and observation of microstructure. The wires (0.40-0.90mm dia.) of round type were tested in the as-received condition. The wires of control groups were TRU-CHROME and REMANIUM, and experimental group was SK wire which was developed by ourselves and made in Korea. The results were as follows; 1. The chemical compositions of control groups and experimental group were austenite stainless steel wires of SOS 304. 2. Higher values of tensile and yield strength in tension were control group I, experimental group, control group II. Maximum tensile and yield strength of experimental group were $203.63{\pm}1.41kg/mm^2$ in 0.70mm diameter and $148.96{\pm}4.88kg/mm^2$ in 0.60mm diameter, and maximum elongation was $5.20{\pm}0.57%$ in 0.45mm diameter. 3. Hardness values of experimental group were similar to control groups. Maximum hardness values were $596.2{\pm}13.66Hv$ in 0.45mm diameter wire of control group I, $590.5{\pm}20.08Hv$ in 0.50mm diameter wire of control group II, and $563.6{\pm}5.35Hv$ in 0.70mm diameter wire of experimental group. 4. Torsion properties of experimental group were similar to control group I and more than control group II. Maximum torsion cycles were $31.8{\pm}2.48$ in 0.45mm diameter of control group I, $17.4{\pm}4.84$ in 0.60mm diameter of control group II, and $24.6{\pm}3.04$ in 0.45mm diameter of experimental group. 5. Maximum bending cycles of experimental group were smaller than control groups. Maximum bending cycles were $9.00{\pm}0.00$ in 0.50mm diameter wire of control group I, $10.0{\pm}0.82$ in 0.40mm diameter wire of control group II, and $8.0{\pm}1.26$ in 0.50mm diameter wire of experimental group. 6. Microstructures of experimental and control groups co-existed with martensited austenite structure and elongated austenite structure. 7. The direction of wire fracture was propagated parallel to torsion direction typically and there was no probability showing wire fracture at inclusions and surface scratches. 8. The type of wire fracture was brittle fracture at initiation site and ductile fracture at core.

  • PDF

Study of dynamic mechanical behavior of aluminum 7075-T6 with respect to diameters and L/D ratios using Split Hopkinson Pressure Bar (SHPB)

  • Kim, Eunhye;Changani, Hossein
    • Structural Engineering and Mechanics
    • /
    • v.55 no.4
    • /
    • pp.857-869
    • /
    • 2015
  • The aluminum 7075-T6 is known as an alloy widely used in aircraft structural applications, which does not exhibit strain rate sensitivity during dynamic compressive tests. Despite mechanical importance of the material, there is not enough attention to determine appropriate sample dimensions such as a sample diameter relative to the device bar diameter and sample length to diameter (L/D) ratio for dynamic tests and how these two parameters can change mechanical behaviors of the sample under dynamic loading condition. In this study, various samples which have different diameters of 31.8, 25.4, 15.9, and 9.5 mm and sample L/D ratios of 2.0, 1.5, 1.0, 0.5, and 0.25 were tested using Split Hopkinson Pressure Bar (SHPB), as this testing device is proper to characterize mechanical behaviors of solid materials at high strain rates. The mechanical behavior of this alloy was examined under ${\sim}200-5,500s^{-1}$ dynamic strain rate. Aluminum samples of 2.0, 1.5 and 1.0 of L/D ratios were well fitted into the stress-strain curve, Madison and Green's diagram, regardless of the sample diameters. Also, the 0.5 and 0.25 L/D ratio samples having the diameter of 31.8 and 25.4 mm followed the stress-strain curve. As results, larger samples (31.8 and 25.4 mm) in diameters followed the stress-strain curve regardless of the L/D ratios, whereas the 0.5 and 0.25 L/D ratios of small diameter sample (15.9 and 9.5 mm) did not follow the stress-strain diagram but significantly deviate from the diagram. Our results indicate that the L/D ratio is important determinant in stress-strain responses under the SHPB test when the sample diameter is small relative to the test bar diameter (31.8 mm), but when sample diameter is close to the bar diameter, L/D ratio does not significantly affect the stress-strain responses. This suggests that the areal mismatch (non-contact area of the testing bar) between the sample and the bar can misrepresent mechanical behaviors of the aluminum 7075-T6 at the dynamic loading condition.

[Retracted]Improving Performance of Foam Proportioner Utilizing Metering Venturi Type ([논문철회]미터링 벤츄리를 이용한 포소화약제 혼합장치의 성능개선)

  • Joo, Seung-Ho;Kong, Ha-Sung;Gong, Ye-Som
    • Fire Science and Engineering
    • /
    • v.29 no.3
    • /
    • pp.48-52
    • /
    • 2015
  • In this study, we have evaluated whether the mixing ratio is proper by creating a mixing device for foam proportioner that mainly is employed in practice utilizing a metering venturi type. In case of the mixing ratio for 3%, water under pressure of 76 mm in diameter and the original liquid of a foam fire extinguishing agent of 31.75 mm in diameter have showed up the fluctuation rate just as much as 3.1~3.5% of the mixing ratio. Because water under pressure of 101.6 mm in diameter and the original liquid of a foam fire extinguishing agent of 38.1 mm in diameter have showed up 3.3~3.7% of the fluctuation rate, water under pressure of 101.6 mm in diameter and the original liquid of a foam fire extinguishing agent of 38.1 mm in diameter have satisfied 3.0~3.9% of performance criterion. And also, in case of the 6% of mixture rate, water under pressure of 76.2 mm in diameter and the original liquid of a foam fire extinguishing agent of 31.75 mm in diameter have showed up the fluctuation rate just as much as 6.4~6.8% of the mixing ratio. Because water under pressure of 101.6 mm in diameter and the original liquid of a foam fire extinguishing agent of 38.1 mm in diameter have showed up 6.0~6.8% of the fluctuation rate, water under pressure of 101.6 mm in diameter and the original liquid of a foam fire extinguishing agent of 38.1 mm in diameter have satisfied 6.0~7.0% of performance criterion.

The design of interconnection network using postorder traversal on Fibonacci tree (피보나치 트리에서 후위순회를 이용한 상호 연결망의 설계)

  • 유명기;김용석
    • Proceedings of the IEEK Conference
    • /
    • 2001.06c
    • /
    • pp.63-66
    • /
    • 2001
  • In this paper, We propose the new interconnection network which is designed to edge numbering labeling using postorder traversal which can reduce diameter when it has same node number with Hypercube, which can reduce total node numbers considering node degree and diameter on Fibonacci trees and its jump sequence of circulant is Fibonacci numbers. It has a simple (shortest oath)routing algorithm, diameter, node degree. It has a spaning subtree which is Fibonacci tree and it is embedded to Fibonacci tree. It is compared with Hypercube. We improve diameter compared with Hypercube.

  • PDF

Nanotube Morphology Control of Ti-30Nb-xTa Alloys by Applied Voltages

  • Kim, Eun-Sil;Choe, Han-Cheol
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 2013.05a
    • /
    • pp.78-78
    • /
    • 2013
  • This study has investigated the nanotube morphology control of Ti-30Nb-xTa alloys by applied voltages. The morphology changed from small diameter to large diameter with increasing applied voltage, whereas, changed from large diameter to small diameter with decreasing applied voltage.

  • PDF

The Development of Multi Pieces Gas Cutting Tip (분리형 가스절단팁 개발)

  • 이권희;김지온;하지수;박부민
    • Proceedings of the KWS Conference
    • /
    • 1999.10a
    • /
    • pp.146-149
    • /
    • 1999
  • To develope the high speed gas cutting tip, consists of 3 pieces, supersonic axisymmetric jets issuing from various kinds of nozzles with a throat diameter of a few milimeters were experimentally investigated. The nozzle inlet pressure was varied from 4 to 8 kgf/$\textrm{cm}^2$. The parameters in nozzle design were throat diameter, throat length, taper angle, outlet diameter. The total pressure variation was measured by the pilot tube, 0.5mm outer diameter, along the center of the free stream jet. Also color Shilieren system was used to visualize the flowfield.

  • PDF

ANGULAR DIAMETER DISTANCE IN PERTURBED FRIEDMANN SPACETIME: EFFECTS OF GRAVITATIONAL WAVES (건드림된 프리이드만 시공간 속의 각지름 거리: 중력파의 효과)

  • SONG D. J.
    • Publications of The Korean Astronomical Society
    • /
    • v.19 no.1
    • /
    • pp.1-10
    • /
    • 2004
  • On the framework of a linearly perturbed Friedmann-Robertson-Walker spacetime, we derive an expression for the cosmological angular diameter distance affected by scalar and tensor perturbations. Our expression is applicable in linear order to distances in general FRW models. We study the effect of a stocastic gravitaional wave background on the two-point correlation function of the angular diameter distance fluctuations and, on the basis of this we also derive an expression for the power spectrum of the angular diameter distance fluctuations.

ON DIAMETER PRESERVING LINEAR MAPS

  • Aizpuru, Antonio;Tamayo, Montserrat
    • Journal of the Korean Mathematical Society
    • /
    • v.45 no.1
    • /
    • pp.197-204
    • /
    • 2008
  • We study diameter preserving linear maps from C(X) into C(Y) where X and Y are compact Hausdorff spaces. By using the extreme points of $C(X)^*\;and\;C(Y)^*$ and a linear condition on them, we obtain that there exists a diameter preserving linear map from C(X) into C(Y) if and only if X is homeomorphic to a subspace of Y. We also consider the case when X and Y are noncompact but locally compact spaces.

Influence of Glass Tube Diameter in the Cold Cathode Fluorescent Lamps for 40-inch LCD-TVs

  • Lee, Min-Kyu;Lee, Kyoung-Ho;Han, Kyu-Hyeon;Lee, Jae-Wook
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2009.10a
    • /
    • pp.707-710
    • /
    • 2009
  • As the inner diameter of CCFL is increased in the range of outer diameters 3~5 mm, the luminance efficiency is increased by the low power consumption. For the outer diameter 5 mm, the efficiency is linearly increased even at the range of a high current.

  • PDF

A Study on Diameter-based AAA Services for Hierarchical Mobile IPv6 (HMIPv6를 위한 Diameter 기반의 AAA 서비스에 관한 연구)

  • Hwang, Sun-Woong;Song, Joo-Seok
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2002.11b
    • /
    • pp.1379-1382
    • /
    • 2002
  • Mobile IPv6에 Diameter 기술을 적용하여 모바일 유저의 인증, 권한 검증, 과금 뿐만 아니라 미래 서비스를 수용할 수 있는 확장성을 보장할 수 있는 AAA 서비스 기술이 IETF의 WG에서 연구되고 있다. 본 논문에서는 Diameter 기반의 AAA 서비스를 Mobile IPv6의 문제점 중 위치 등록에 따른 시그널링수와 긴 핸드오프 지연을 개선한 Hierarchical Mobile IPv6 기술에 적용하여 강화된 보안 및 빠른 핸드오프를 통해 끊김 없는 서비스 제공 방안을 제시하고자 한다.

  • PDF