• Title/Summary/Keyword: DG

Search Result 845, Processing Time 0.044 seconds

The Installable Maximum DG Capacity Considering LDC Parameters of ULTC and SVR in Distribution Systems (ULTC 와 SVR 이 설치된 배전계통에서 LDC Parameters 을 고려한 최대 DG 용량 산정)

  • Kim, Mi-Young;Hara, Ryoichi;Kita, Hiroyuki
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.27-28
    • /
    • 2008
  • For stable and sustainable energy supply, distributed generator (DG) has become an essential and indispensable element from environmental and energy security perspectives. However, installation of DG in distribution systems may cause negative affects on feeders because power outputs of DG could be changed irregularly. One of major negative affects is variation in voltage profile. In general, voltage regulation devices such as under load tap changer (ULTC) at distribution substation and step voltage regulator (SVR) along feeder in distribution system are used to maintain customers' receiving voltage within a predetermined range. These regulators are controlled by line drop compensation (LDC) method which calls for two parameters; the equivalent impedance and the load center voltage. Therefore, consideration of DG outputs in the LDC parameter design procedure may give large impact on the installable DG capacity. This paper proposes a method that estimates maximum Installable DG capacity considering LDC parameters of ULTC and SVR. The proposed algorithm is tested with model network.

  • PDF

Synthesis of Diglyceride Containing Caprylic acid by Immobilized Lipase Catalyzed Esterification of Monoglyceride in a Solvent Free System (모노글리세리드와 카프릴산으로부터 고정화 리파제를 사용한 디글리세리드 생산)

  • Lee, Jang-Woon;Kang, Sung-Tae
    • Microbiology and Biotechnology Letters
    • /
    • v.37 no.4
    • /
    • pp.365-370
    • /
    • 2009
  • For the production of diglyceride (DG) containing medium chain fatty acid, which could be utilized as a substrate to structured lipid production, monoglyceride (MG) and caprylic acid were reacted in the presence of lipase. The reaction system was well mixed homogeneously without using any organic solvent. Among the lipases investigated, Lipozyme RM IM and Novozym 435 were selected on the basis of equilibrium DG yields from the medium chain fatty acid and MG. And reaction conditions such as addition of molecular sieve, water content of immobilized lipase, reaction temperature, and mole ratio of MG/caprylic acid are optimized to increase DG production by using Lipozyme RM IM. DG content of reaction mixture showed 8% increase by adding molecular sieve to reaction mixture. Removal of water from the immobilized lipase could affect seriously equilibrium content of DG. More than 2.8%(w/w) removal of water from the support could make 44% of DG. Optimum temperature was found to $60^{\circ}C$. Temperature shift from $60^{\circ}C$ to $25^{\circ}C$ resulted in increase of free fatty acid (FFA) content. The equilibrium DG yield was not seriously affected by on MG/caprylic acid molar ratio. However, at the stoichiometric ratio of 1:1 the highest DG yield was obtained. Increasing MG/caprylic acid ratio from 0.3 to 1.8 decreased FFA content from 34% to 13%, while MG content increased from 27% to 50%.

Two-Dimensional Grouping Index for Efficient Processing of XML Filtering Queries (XML 필터링 질의의 효율적 처리를 위한 이차원 그룹핑 색인기법)

  • Yeo, Dae-Hwi;Lee, Jong-Hak
    • Journal of Information Technology and Architecture
    • /
    • v.10 no.1
    • /
    • pp.123-135
    • /
    • 2013
  • This paper presents a two-dimensional grouping index(2DG-index) for efficient processing of XML filtering queries. Recently, many index techniques have been suggested for the efficient processing of structural relationships among the elements in the XML database such as an ancestor- descendant and a parent-child relationship. However, these index techniques focus on simple path queries, and don't consider the path queries that include a condition value for filtering. The 2DG-index is an index structure that deals with the problem of clustering index entries in the twodimensional domain space that consists of a XML path identifier domain and a filtering data value domain. For performance evaluation, we have compared our proposed 2DG-index with the conventional one dimensional index structure such as the data grouping index (DG-index) and the path grouping index (PG-index). As the result of the performance evaluations, we have verified that our proposed 2DG-index can efficiently support the query processing in XML databases according to the query types.

Design of RF Receiver using Independent-Gate-Mode Double-Gate MOSFET (Independent-Gate-Mode Double-Gate MOSFET을 이용한 RF Receiver 설계)

  • Jeong, Na-Rae;Kim, Yu-Jin;Yun, Ji-Sook;Park, Sung-Min;Shin, Hyung-Soon
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.46 no.10
    • /
    • pp.16-24
    • /
    • 2009
  • Independent-gate-mode double-gate(IGM-DG) MOSFET overcomes the limitation of 3-terminal device structure, and enables to operate with different voltages for front-gate and back-gate. Therefore, circuit designs becomes not only simple, but also area-efficient due to the controllability of the 4th terminal provided by IGM-DG MOSFETs. In this paper, an RF receiver utilizing IGM-DG MOSFETs is presented and also, the circuit performance is verified by the HSPICE simulations. Besides, the circuit analysis and optimization are performed for various IGM-DG characteristics.

An Adaptive Reclosing Algorithm Considering Distributed Generation

  • Seo, Hun-Chul;Kim, Chul-Hwan
    • International Journal of Control, Automation, and Systems
    • /
    • v.6 no.5
    • /
    • pp.651-659
    • /
    • 2008
  • Autoreclosing techniques have been used in power systems to maintain system stability and continuity of supply. Environmental and economical issues have driven significant increases in the development of distributed generation (DG). DG connected to distribution systems, however, may impose negative influences with respect to power quality, protection, and stability, because DG can cause some challenges to protection, especially to reclosing. For this reason, in order to improve the reliability and safety of the distribution system, the rules and guidelines suggest that the DG system needs to be rapidly disconnected from the system before reclosing. We present, in this paper, an adaptive reclosing algorithm considering the DG. The algorithm consists of an angle oscillation's judgment, the emergency extended equal-area criterion (EEEAC), the calculation of an optimal reclosing time, and a reconnection algorithm. Our simulation results for three different DG technologies with Electromagnetic Transient Program (EMTP) indicate that we can maintain transient stability while the DG is protected against disturbances.

Optimal Capacity and Allocation Distributed Generation by Minimization Operation Cost of Distribution System (배전계통 운영비용의 최소화에 의한 분산전원의 최적 용량과 위치결정)

  • 배인수;박정훈;김진오;김규호
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.53 no.9
    • /
    • pp.481-486
    • /
    • 2004
  • In operation of distribution system, $DG_s$ Distributed Generations) are installed as an alternative of extension and establishment of substations and transmission and distribution lines according to increasing power demand. In operation planning of $DG_s$, determining optimal capacity and allocation gets economical pro(it and improves power reliability. This paper proposes determining a optimal number, size and allocation of $DG_s$ needed to minimize operation cost of distribution system. Capacity of $DG_s$ (or economical operation of distribution system estimated by the load growth and line capacity during operation planning duration, DG allocations are determined to minimize total cost with power buying cost. operation cost of DG, loss cost and outage cost using GA(Genetic Algorithm).

The Maximum Installable DG Capacity According to Operation Methods of Voltage Regulator in Distribution Systems (배전계통의 전압조정기 운영방법에 따른 분산형전원 최대 도입 용량 산출)

  • Kim, Mi-Young
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.58 no.7
    • /
    • pp.1263-1269
    • /
    • 2009
  • Stable and sustainable power supply means maintaining a certain level of power quality and service while securing energy resource and resolving environmental issues. Distributed generation (DG) has become an essential and indispensable element from environmental and energy security perspectives. It is known that voltage violation is the most important constraint for load variation and the maximum allowable DG. In distribution system, sending voltage from distribution substation is regulated by ULTC (Under Load Tap Changer) designed to maintain a predetermined voltage level. ULTC is controlled by LDC (Line Drop Compensation) method compensating line voltage drop for a varying load, and the sending voltage of ULTC calls for LDC parameters. The consequence is that the feasible LDC parameters considering variation of load and DG output are necessary. In this paper, we design each LDC parameters determining the sending voltage that can satisfy voltage level, decrease ULTC tap movement numbers, or increase DG introduction. Moreover, the maximum installable DG capacity based on each LDC parameters is estimated.

Some Device Design Considerations to Enhance the Performance of DG-MOSFETs

  • Mohapatra, S.K.;Pradhan, K.P.;Sahu, P.K.
    • Transactions on Electrical and Electronic Materials
    • /
    • v.14 no.6
    • /
    • pp.291-294
    • /
    • 2013
  • When subjected to a change in dimensions, the device performance decreases. Multi-gate SOI devices, viz. the Double Gate MOSFET (DG-MOSFET), are expected to make inroads into integrated circuit applications previously dominated exclusively by planar MOSFETs. The primary focus of attention is how channel engineering (i.e. Graded Channel (GC)) and gate engineering (i.e. Dual Insulator (DI)) as gate oxide) creates an effect on the device performance, specifically, leakage current ($I_{off}$), on current ($I_{on}$), and DIBL. This study examines the performance of the devices, by virtue of a simulation analysis, in conjunction with N-channel DG-MOSFETs. The important parameters for improvement in circuit speed and power consumption are discussed. From the analysis, DG-DI MOSFET is the most suitable candidate for high speed switching application, simultaneously providing better performance as an amplifier.

Analytical and sensitivity approaches for the sizing and placement of single DG in radial system

  • Bindumol, E.K.;Babu, C.A.
    • Advances in Energy Research
    • /
    • v.4 no.2
    • /
    • pp.163-176
    • /
    • 2016
  • Rapid depletion of fossil based oil, coal and gas reserves and its greater demand day by day necessitates the search for other alternatives. Severe environmental impacts caused by the fossil fire based power plants and the escalating fuel costs are the major challenges faced by the electricity supply industry. Integration of Distributed Generators (DG) especially, wind and solar systems to the grid has been steadily increasing due to the concern of clean environment. This paper focuses on a new simple and fast load flow algorithm named Backward Forward Sweep Algorithm (BFSA) for finding the voltage profile and power losses with the integration of various sizes of DG at different locations. Genetic Algorithm (GA) based BFSA is adopted in finding the optimal location and sizing of DG to attain an improved voltage profile and considerable reduced power loss. Simulation results show that the proposed algorithm is more efficient in finding the optimal location and sizing of DG in 15-bus radial distribution system (RDS).The authenticity of the placement of optimized DG is assured with other DG placement techniques.

The Study of Islanding State Detection of Distributed Generation Considering Fault Location (사고위치에 따른 분산전원 고립운전 상태 검출에 관한 연구)

  • 정승복;김재철
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2003.11a
    • /
    • pp.107-109
    • /
    • 2003
  • This paper studies islanding detection distributed of distributed generation(DG). The study of islanding detection has been disconnected DG when power islanding was detected but fault type wasn't distingish. Nearby feeder fault the fault of feeder that not interconnected DG, is a little affect DG and distribution system. Therefore DG not need to disconnect distribution system. We studied islanding detection algorithm considering fault location.

  • PDF