• Title/Summary/Keyword: DFT 연구

Search Result 266, Processing Time 0.02 seconds

Degradation of Sulfonamide Antibiotic Substances by Ozonation: An Experimental and Computational Approach (설폰아미드계 항생물질의 오존산화분해에 대한 계산화학적 해석 및 실험적 검증)

  • Won, Jung Sik;Lim, Dong Hee;Seo, Gyu Tae
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.36 no.6
    • /
    • pp.442-450
    • /
    • 2014
  • Concern has grown over a presence of micropollutants in natural water since sulfonamide antibiotic substances such as sulfamethazine, sulfamethoxazole, sulfathiazole have been frequently detected in Nakdong River, Korea. The current work investigates the degradation of the three sulfonamide substances by using quantum chemistry calculations of density functional theory (DFT) and experimental measurement techniques of Fourier transform infrared spectroscopy (FT-IR) and ultraviolet-visible spectrophotometer (UV-VIS). DFT calculations demonstrate that the lowest energy gap between the highest occupied molecular orbital (HOMO) and the lowest unoccupied molecular orbitals (LUMO) lies in sulfanilamide functional group of sulfonamide, implying that the sulfanilamide functional group would be the most active site for ozone oxidation. Also, UV-VIS spectra and FT-IR analysis reveal that 260 nm band originated from sulfanilamide group was absent after ozone oxidation, indicating that a functional group of amine (N-H) was removed from sulfanilamide. Both theoretical and experimental observations agree well with each other, demonstrating the DFT calculation tool can be an alternative tool for the prediction of chemical reactions in purification treatment processes.

Typology of Wholesalers in Dongdaemun Fashion Town according to Contractor Selection Criteria (동대문 패션 타운의 패션 타운의 도매업체 현황 및 협력 업체 선정 기준에 따른 유형화)

  • Seo, Min-Jeong;Lee, Ji-In;Lee, Kyu-Hye
    • The Research Journal of the Costume Culture
    • /
    • v.17 no.5
    • /
    • pp.819-833
    • /
    • 2009
  • The current research focused on exploration of a well known Korean fashion and clothing industry cluster, Dongdaemun Fashion Town(DFT). Many clothing and fashion wholesalers in DFT with various business formats are trying to obtain competitive advantages. For the empirical study, a questionnaire was developed. Items measuring descriptive statistics for each business and contractor selection criteria were included in the survey. 161 data from Employees of various wholesalers of DFT were used for statistical analysis. Majority of DFT customers were buyers of Internet shopping malls and street retail shops. 64% of them used domestic contractors for sourcing products. Most of them managed less than three contractors. Contractor selection criteria were factorized as flexibility, production ability, stability, fame and location. Wholesalers were segmented into three groups: product oriented, flexibility oriented and stability oriented groups. Group differences in terms of business practices were assessed and strategic implications were included.

  • PDF

A DFT Deblurring Algorithm of Blind Blur Image (무정보 blur 이미지 복구를 위한 DFT 변환)

  • Moon, Kyung-Il;Kim, Chul
    • Journal of The Korean Association of Information Education
    • /
    • v.15 no.3
    • /
    • pp.517-524
    • /
    • 2011
  • This paper presents a fast blind deconvolution method that produces a deblurring result from a single image in only a few seconds. The high speed of our method is enabled by considering the Discrete Fourier Transform (DFT), and its relation to filtering and convolution, and fast computation of Moore-Penrose inverse matrix. How can we predict the behavior of an arbitrary filter, or even more to the point design a filter to achieve certain specifications. The idea is to study the frequency response of the filter. This concept leads to an useful convolution formula. A Matlab implementation of our method usually takes less than one minute to deblur an image of moderate size, while the deblurring quality is comparable.

  • PDF

A Study on the Source Reconstruction Feature Usig the Extended Proy Method (확장 Prony법을 이용한 음원 재구성특성에 관한 연구)

  • 이금원;김경기
    • Journal of Biomedical Engineering Research
    • /
    • v.11 no.2
    • /
    • pp.289-294
    • /
    • 1990
  • In this paper, for acoustic source reconstruction using angular frequency propagation method, the extended Prony method is propsed which is useful due to not having the inherent property of DFT. The simulation is carried out and its improved results are shown explicitly by comparing with DFT case.

  • PDF

Growth and Flowering Responses of Carnation (Dianthus caryophyllus) as influenced by Hydroponic Systems and Nutrient Solutions (재배방식과 양액의 종류에 따른 카네이션(Dianthus caryophyllus)의 생장과 개화반응)

  • 정순주;이범선;강종구;서범석
    • Journal of Bio-Environment Control
    • /
    • v.6 no.3
    • /
    • pp.190-197
    • /
    • 1997
  • This study was conducted to determine the optimum hydroponic system and nutrient solution for promoting the growth and flowering of hydroponically grown carnation. DFT (deep flow technique) and NFT (nutrient film technique) systems were employed and four kinds of nutrient solution, which are Cooper solution, Yamasaki solution, balanced nutrient solution by Japanese Horticultural Experiment Station and PTG solution in the Netherlands were used and compared. pH was lowest in the PTG solution compared to the other nutrient solutions used. Plant height was highest in the DFT system in the plot of PTG solution as of 53.0 cm at 88 days after transplanting, while lowest in NFT system with Cooper solution. Stem diameter was more thickened in NFT system with PTG solution as of 7.2 mm at 88 days after transplanting. Days to flowering was shortened to 122.3 days in NFT system when PTG solution was used. This results suggested a combination of NFT system with PTG solution as optimum hydroponic system and nutrient solution for cut carnation production. Further trials as to the management of nutrient solution by glowing stages should be followed.

  • PDF

Physical Database Design for DFT-Based Multidimensional Indexes in Time-Series Databases (시계열 데이터베이스에서 DFT-기반 다차원 인덱스를 위한 물리적 데이터베이스 설계)

  • Kim, Sang-Wook;Kim, Jin-Ho;Han, Byung-ll
    • Journal of Korea Multimedia Society
    • /
    • v.7 no.11
    • /
    • pp.1505-1514
    • /
    • 2004
  • Sequence matching in time-series databases is an operation that finds the data sequences whose changing patterns are similar to that of a query sequence. Typically, sequence matching hires a multi-dimensional index for its efficient processing. In order to alleviate the dimensionality curse problem of the multi-dimensional index in high-dimensional cases, the previous methods for sequence matching apply the Discrete Fourier Transform(DFT) to data sequences, and take only the first two or three DFT coefficients as organizing attributes of the multi-dimensional index. This paper first points out the problems in such simple methods taking the firs two or three coefficients, and proposes a novel solution to construct the optimal multi -dimensional index. The proposed method analyzes the characteristics of a target database, and identifies the organizing attributes having the best discrimination power based on the analysis. It also determines the optimal number of organizing attributes for efficient sequence matching by using a cost model. To show the effectiveness of the proposed method, we perform a series of experiments. The results show that the Proposed method outperforms the previous ones significantly.

  • PDF

A Study on Automatic Multi-Power Synchronous Transfer Switch using New DFT Comparator (새로운 DFT 비교기를 이용한 자동 다전원 동기절체 스위치에 관한 연구)

  • Kwak, A-Rim;Park, Seong-Mi;Son, Gyung-Jong;Park, Sung-Jun;Kim, Jong-Cheol
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.25 no.3
    • /
    • pp.423-431
    • /
    • 2022
  • The UPS(Uninterruptible Power Supply) system operates in the battery charging mode when the grid is normal, and in the UPS mode, which is the battery discharge mode when a grid error occurs. Since the UPS must supply the same voltage as the grid to the load within 4 [ms] in case of a grid error, the switching time and power recovery time should be short when controlling the output voltage and current of the UPS, and the power failure detection time is also important. The power outage detection algorithm using DFT(Discrete Fourier Transform) proposed in this paper compares the grid voltage waveform with the voltage waveform including the 9th harmonic generated through DFT using Schmitt trigger to detect power outage faster than the existing power outage monitoring algorithm. There are advantages. Therefore, it is possible to supply instant and stable power when switching modes in the UPS system. The multi-power-applied UPS system proposed in this paper uses DFT, which is faster than the conventional blackout monitoring algorithm in detecting power failure, to provide stable power to the load in a shorter time than the existing power outage monitoring algorithm when a system error occurs. The detection method was applied. The changeover time of mode switching was set to less than 4 [ms], which is 1/4 of the system cycle, in accordance with KSC 4310 regulation, which was established by the Industrial Standards Council on the regulation of uninterruptible power supply. A 10 [kW] UPS system in which commercial voltage, vehicle generator, and auxiliary diesel generator can be connected to each of the proposed transfer devices was constructed and the feasibility was verified by conducting an experiment.

Dynamic Analysis of Structures under Moving Loads in Time and Frequency Domain (이동하중을 받는 구조물에 대한 시간영역과 주파수영역에서의 동적해석)

  • Kong, Min Sik;Yhim, Sung Soon
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.11 no.3
    • /
    • pp.87-94
    • /
    • 2007
  • A structural dynamic analysis can be divided into a time domain analysis and a frequency domain analysis. The time domain analysis makes use of a direct integration method or a mode superposition method and the frequency domain analysis applies a DFT method. Generally the DFT method is more effective method in case of calculating response of periodic excitation. But in case of transient excitation exact solution can not be acquired. So, by modifying the response or increasing the period accuracy of solution can be enhanced. Accordingly this study analyzed dynamic responses of structures under aperiodic moving load in time domain and frequence domain. Consequently it is concluded that exact solution would be get enough using DFT method by increasing the duration of free vibration or modifying the dynamic response.