• Title/Summary/Keyword: DCM(Deep Cement Mixing) Method

Search Result 23, Processing Time 0.023 seconds

Stability Analysis of DCM treated Ground Using Centrifuge Test (원심모형시험을 이용한 DCM 처리지반의 안정성 평가)

  • Kim, Byoung-Il;Yoo, Wan-Kyu;Lee, Seung-Hyun;Han, Jin-Tae
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • v.11 no.3
    • /
    • pp.105-110
    • /
    • 2011
  • Recently, a deep mixture method as a soil improvement method of marine soft ground, which causes less noise and vibration than other methods, are widely used. In this study, for DCM(Deep Cement Mixing) method, one of the deep mixture method, optimum mixing ratio of clay-cement was suggested using uniaxial compression tests on specimens with various mixing ratio of claycement. In addition, the stability of a caisson on tangent circle-type and wall-type DCM treated ground was evaluated using centrifuge tests. As a result, optimum mixing ratio of clay-cement was 28.5% and the stability of the caisson on DCM treated ground was confirmed. However, the lateral displacement of the caisson on the wall-type DCM treated ground was 7% less and the settlement of that was 39% less than the case of the tangent-circle-type DCM method.

Application for Self-Supported Retaining Wall Using Deep Cement Mixing (DCM(심층혼합처리공법)에 의한 자립식 흙막이 적용사례)

  • Jeong, Gyeong-Hwan;Kim, Yong-Wan;Shin, Min-Sik;Han, Kyoung-Tae;Kim, Tae-Hyo
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2006.03a
    • /
    • pp.257-267
    • /
    • 2006
  • The earth retaining wall systems for excavation works in a populated urban area or a poor soil deposit can be limited due to various restriction. Thus there are various methods to be applied for them such as the soldier pile method, the diaphragm wall with counterfort and so on. In this study, the self-supported earth retaining wall using the DCM(Deep Cement Mixing) method, including its merits, demerits and some important characteristics occured in the design and the construction stage, was introduced. It might be reference for the other design and construction procedures using the DCM method.

  • PDF

Case Study of Stress Concentration Ratio of Composite Ground Improved by Deep Cement Mixing Method (심층혼합처리공법으로 개량된 복합지반의 응력분담비에 대한 사례 연구)

  • Yoo, Wan-Kyu;Kim, Byoung-Il;Kim, Young-Uk
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.13 no.7
    • /
    • pp.3216-3223
    • /
    • 2012
  • Deep cement mixing method (DCM) is one of the most effective improving methods for deep soft ground. The strength of soft soil can be increased in a short period of time with less noise and vibration. However, it is necessary to determine the stress transferring and concentration ratio of the composite soft ground for estimating the settlement behaviors. In this study, a model test was undertaken to investigate the stress distribution of the improved soil. Results of the model test shows that stresses were concentrated mainly on the improved areas by DCM and the concentration ratios (35.4, 28.6, 27.02) were obtained using several different techniques. These were well in accordance with other previous research results (26.52, 32.5).

Application to Breakwater Foundation by DCM (DCM 공법에 의한 방파제 기초 적용사례)

  • Gu, Im-Sik;Kim, Young-Sang;Jeong, Gyeong-Hwan;Choi, Jeong-Uk;Shin, Min-Sik;Kim, Jae-Hyon
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2006.03a
    • /
    • pp.372-382
    • /
    • 2006
  • The DCM(Deep Cement Mixing) Method was introduced domestically in 1985 and has been applied widely to improve stability, increase bearing capacity and reduce settlement of the structure. It has been only performed by the combined equipment to improve the soft ground in coastal areas. But it has qualify-control problems such as interference of waves and improving depth, etc. Therefore DCM Barge of specialist equipment, named by Dong Ji Ho, was equipped with three mixing shafts with four rod and installed GPS system In itself, had been developed in 2005 for the purpose of solving the above problems. This paper represents about Dong Ji Ho's qualify-control system as well as it's first domestic application to in-situ trial test and the original design of the Ulsan breakwater site.

  • PDF

Effects of DCM Column Properties in Softground on Stabilities of Underground Roadways (연약지반내 DCM 개량체의 특성이 지하차도의 안정성에 미치는 영향)

  • Ahn, Tae-Bong
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.30 no.2C
    • /
    • pp.77-84
    • /
    • 2010
  • In planning underground roadway foundation on soft ground, deep cement mixing method (DCM) is employed. The proper mixing ratio using batch test and replacement rates that meet strength criteria are used for deep cement mixing column. Stiffness ratio and distance between deep cement mixing columns (C.T.C) are varied to find out influences on stress, displacement, and differential settlement. The replacement ratios that meet settlement criteria are 10~35%. As stiffness varies, stress reaches at 769.kPa that exceed criteria due to stress concentration when stiffness ratio difference is over 30. Also, when C.T.C is 5 m, stress spreads to soils, so C.T.C need to be considered carefully. The vertical displacement is 0.6~1.56 cm, and angular distortion is 1/909~1/510.

Case Studies of Penetration Characteristics of DCM Wall Using Spiral Mixing Blades in Soil Layers (특수교반날개를 사용한 DCM 공법의 지반 관입 특성에 대한 사례연구)

  • Jung, Doo-Hoi;Jeong, Gyung-Hwan;Yang, Tae-Seon
    • Journal of the Korean Geotechnical Society
    • /
    • v.23 no.3
    • /
    • pp.133-140
    • /
    • 2007
  • DCM (Deep Cement Mixing Method) has been applied to build structures such as self-supported earth retaining walls. DCM columns should be penetrability into the stiff layer to assure the self-supporting ability. On the penetration increase of blade attached to the DCM mixing tools, a spiral mixing blade has been revised. Penetration characteristics of spiral blades in the stiff soil layer were evaluated through Gimhae and Incheon areas. The spiral mixing blades could penetrate into the stiff soil layers which have the N-value of greater than 30 although the penetration rate is somewhat slow. Penetration characteristics and economical efficiency should be discussed to determine the critical depth of the spiral mixing blade because the penetration efficiency can decrease in the stiff layer in this paper.

Technology Trends and Patents Analysis of Auger bit for Deep Cement Mixing (DCM) Method (심층혼합처리 공법용 오거비트의 기술동향 및 특허분석)

  • Min, Kyongnam;Lee, Dongwon;Lee, Jaewon;Kim, Keeseok;Yu, Jihyung;Jung, Chanmuk;Hoang, Truong Xuan;Kwon, Yong Kyu
    • The Journal of Engineering Geology
    • /
    • v.28 no.3
    • /
    • pp.431-441
    • /
    • 2018
  • To set up the future research and development direction for Auger bit, this study analyzed publicized patent trends of Deep Cement Mixing method (DCM) in Korea, USA, Japan, and Europe. DCM method was firstly classified into wing shapes and the number of rods according to the technical scope, and secondly, classified into 8 types according to type of screw and rotation axial. A total of 2,815 patents were searched and 448 validated patents were selected through de-duplication and filtering. As a result of the analysis of the portfolio through the number of patents and growth stages, it was selected as the core technology that auger is deemed to have high growth potential and if there is a patent similar to core technology through a patent barrier analysis, the basic data is suggested to develop the design around and differentiated technologies.

A Case Study on the High-quality DCM applied to the Foundation of Breakwater (방파제 기초에 적용된 고품질 DCM공법의 설계 및 시공 사례)

  • Kang, Yeoun-Ike;Shim, Min-Bo;Shim, Sung-Hyun;Kim, Ha-Young;Shim, Jae-Bum;Chun, Youn-Chul;Yoon, Jung-Ik
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2009.09a
    • /
    • pp.815-826
    • /
    • 2009
  • The paper presents a case study addressing the design and construction aspects for DCM(Deep Cement Mixing) method employed as the foundation of a caisson type breakwater with heavy weight(10,700 ton/EA) and a high design wave height($H_{1/3}$=8.7m). The DCM was designed for the project(Ulsan New Port North Breakwater Phase 1) by optimizing the pattern of DCM columns with a combination of short and long columns (i.e., block type(upper 3m)+wall type(lower)) and considering overlapped section between columns as a critical section against shear force where the coefficient of effective width of treated column($\alpha$) was estimated with caution. It was shown that the value can be 0.9 under the condition with the overlapped width of 30cm. In addition to that, a field trial test was performed after improving conventional DCM equipment (e.g., mixing blades, cement paste supplying pipes, multi auger motor, etc.) to establish a standardized DCM construction cycle (withdrawal rate of mixing blades) which can provide the prescribed strength. The result of the field strength test for cored DCM specimens shows that the averaged strength is larger than the target strength and the distribution of the strength(with a defect rate of 7%) also satisfies with the quality control normal distribution curve which allows defect rate of 15.9%.

  • PDF

The Case Study on the Design, Construction, Quality Control of Deep Cement Mixing Method (심층혼합처리공법(DCM)의 설계, 시공 및 품질관리 사례 연구)

  • Kim, Byung-Il;Park, Eon-Sang;Han, Sang-Jae
    • Journal of the Korean Geosynthetics Society
    • /
    • v.20 no.4
    • /
    • pp.19-32
    • /
    • 2021
  • In this study, evaluation and consideration of domestic/overseas design, construction, and quality control performed by the authors on the deep cement mixing method were performed, and improvements for the development of the DCM method were suggested in the future. As a result of this study, it was found that the cross-sectional area correction for strength is required during the laboratory test of mix proportion, and caution is required because the extrapolation method may lead to different results from the actual one. Applicable design methods should be selected in consideration of both the improvement ratio and the type of improvement during design, and it was confirmed that the allowable compressive strength to which the safety factor was applied refers to the standard value for stability review and not the design parameters. In the case of the stress concentration ratio, rather than applying a conventional value, it was possible to perform economical design by calculating the experimental and theoretical stress concentration ratio reflecting the design conditions. In the case where pre-boring is expected during construction, if the increased water content is not large compared to the original, there were cases where a major problem did not occur even if the result that did not consider the increase in water content was used. In addition, it was confirmed that when the ratio of the top treatment length to the improved length is high, a small amount of design cement contents per unit length can be injected during construction. In the case of quality control, it was evaluated that D/4~2D/4 for single-axis and D/4 point for multi-axis were optimal for coring of grouting mixtures. As an item for quality control, it is judged that the standard that considers the TCR along with the unconfined compressive strength of grouting mixtures is more suitable for the domestic situation.

Effect of Sea Water on Curing and Strength of Cemented Sand (해수가 고결모래의 양생 및 강도에 미치는 영향)

  • Park, Sung-Sik;Lee, Jun-Woo
    • Journal of the Korean Geotechnical Society
    • /
    • v.28 no.6
    • /
    • pp.71-79
    • /
    • 2012
  • Sand compaction pile and stone column replacement methods have been commonly used for improving soft ground in the nearshore. Recently, DCM (Deep cement mixing) method, which can harden soft clays by mixing with cement, is more popularly used in such soft ground improvement. Sandy soils also exist in the seashore. Therefore, in this study, the effect of salinity in sea water and curing methods on the strength of cemented sand was evaluated in terms of unconfined compressive strength (UCS). The sand was mixed with five different cement ratios and distilled water or sea water, and then compacted into a cylindrical specimen. They were cured for 3 days under sea water for DCM construction condition and air cured for onshore curing condition. When a specimen was cured under sea water without confinement, it was easily collapsed due to initiation of cracks. When the cement ratio and curing method were the same, the UCS of the specimen without sea water was at maximum 3.5 times higher than those with sea water. The sea water used for mixing sand had more influence on strength reduction than the sea water used for curing. When the cement ratio was the same, the UCS of air-cured specimen was at average 2 times higher than those of water-cured specimen, regardless of water used.