• 제목/요약/키워드: DC voltage decay

검색결과 8건 처리시간 0.026초

전력케이블 열화진단기법의 현장적용 (Field Application of Power Cable Diagnosis System)

  • 김주용;한재홍;송일근;김상준;이재봉;오재형
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2002년도 춘계학술대회 논문집 유기절연재료 전자세라믹 방전플라즈마 일렉트렛트 및 응용기술
    • /
    • pp.148-151
    • /
    • 2002
  • In order to prevent the failures of underground distribution power cables we need to measure insulation condition in the field. Until now we used DC high voltage as a power source for the cable diagnosis but it was not proper method to the XLPE insulation cables because DC high voltage can affect sound insulation and can't diagnose exactly insulation degradation. For these reasons we imported isothermal relaxation current measurement system called by KDA-1 from germany but it's reliability did not proved in our URD cables. DC voltage decay measurement system was developed by domestic company but they don't have field experience. In this paper we tried to prove reliability of these two systems in the field. Through the field diagnosis and Ac breakdown test the two systems showed similar results.

  • PDF

케이블 절연열화진단과 실 계통 적용 (Insulation Diagnostics of Power Cables and Application to Real Distribution System)

  • 이동영;김주용;송일근
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 하계학술대회 논문집 D
    • /
    • pp.1569-1571
    • /
    • 1999
  • In this work, we have performed the application experiment for real distribution line to diagnose the underground power cables using DC voltage decay measurement system. We have also performed the Isothermal Relaxation Current test for the same distribution line using KDA-l. We could confirmed possibility of grading the insulation aging state of underground power cables. Therefore, we conclude that it is possible to apply DC voltage decay method to the real distribution line.

  • PDF

전압인가식 제전기의 특성에 관한 연구 (A Study on Characteristics of a Volatage-Applied Electrostatic Reducer)

  • 이동훈;정용철
    • 한국안전학회지
    • /
    • 제10권2호
    • /
    • pp.77-83
    • /
    • 1995
  • An electrostatic reducer of a multi-pole high DC voltage applied type and a high frequency square wave voltage applied type have been studied to eliminate effectively and safely electrostatic charge on a dummy charged material. As a fundamental experiments, measurement were made on the decay time as a function of distance between electrostatic reducer and charged body, skewed angle of electrostatic reducer installed and wind speed of generated ions(+ or -) by electrostatic reducer with high DC voltage and high frequency square wave voltage. Based oil the results above, a appropriate installation and method were produced as a trial for factory.

  • PDF

직류전압감쇄법을 이용한 전력케이블의 절연열화진단 (Diagnostics of Power Cables using DC Voltage Decay method)

  • 이동영;김상준;김주용;송일근
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1997년도 하계학술대회 논문집 E
    • /
    • pp.1688-1691
    • /
    • 1997
  • In this work, we have developed the off-line diagnostic system for power cable insulation using DC voltage decay method to diagnose the insulation degradation of underground power cables. Measurement errors of diagnostic system are less than 1% for $1T{\Omega}$ internal resistor. We have also developed measurement and diagnostic programs for win95 which is suitable for the database construction and the management of data. We could conclude that it is possible to apply this system to the multi-grounded underground cable systems.

  • PDF

A DFT Based Filtering Technique to Eliminate Decaying dc and Harmonics for Power System Phasor Estimation

  • Oh Yong- Taek;Balamourougan V.;Sidhu T.S.
    • KIEE International Transactions on Power Engineering
    • /
    • 제5A권2호
    • /
    • pp.138-143
    • /
    • 2005
  • During faults, the voltage and current signals available to the relay are affected by the decaying dc component and harmonics. In order to make appropriate and accurate decisions, most of the relaying algorithms require the fundamental frequency phasor information that is immune to decaying dc effect and harmonics. The conventional Fourier ph as or estimation algorithm is affected by the presence of decaying-exponential transients in the fault signal. This paper presents a modified Fourier algorithm, which effectively eliminates the decaying dc component and the harmonics present in the fault signal. The decaying dc parameters are estimated by means of an out-of-band filtering technique. The decaying dc offset and harmonics are removed by means of a simple computational procedure that involves the design of two sets of Orthogonal digital OFT filters tuned at different frequencies and by creating three off-line look-up tables. The technique was tested for different decay rates of the decaying dc component. It was also compared with the conventional mimic plus the full cycle OFT algorithm. The results indicate that the proposed technique has a faster convergence to the desired value compared to the conventional mimic plus OFT algorithms over a wide range of decay rates. In all cases, the convergence to the desired value was achieved within one cycle of the power system frequency.

직접토크제어에 의한 브러시리스 직류전동기의 센서리스 속도제어 (A sensorless speed control of brushless DC motor by using direct torque control)

  • 윤경국;오세진;김덕기
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제39권9호
    • /
    • pp.935-939
    • /
    • 2015
  • 본 논문은 브러시리스 직류전동기의 센서리스 속도제어 방법에 관해 기술하며 센서리스 속도제어를 위해 직접토크제어 및 전류오차보상법을 사용하였다. 직접토크제어는 토크응답 속도가 빠르고 파라미터 변동에 강인하며 벡터제어 드라이브에 비해 하드웨어가 단순하고 적은 비용으로 시스템을 구성할 수 있다. 그리고 센서리스 속도제어를 위해 전류오차보상법을 사용하였는데 이 제어법은 실제 전동기 및 수식모델 전동기의 두 고정자 전류가 똑같아 지도록 제어된 전압을 전동기에 인가하여 전동기의 속도를 추정하는 방법이다. 본 논문에서 사용한 제어법은 제어기 구성이 간단하며 PI 제어기도 필요 없는 강인한 제어를 수행할 수 있다. 본 논문에서 제안하는 속도제어법의 검증을 위해 컴퓨터 모의실험을 실시하였으며 모의실험 결과 저속, 중속 및 고속영역에서의 양호한 속도특성 및 부하특성을 확인하였다.

전력케이블 열화진단용 측정장치 개발 (Development of Power Cable Diagnostic and Insulation Measurement System)

  • 이동영;권혁일;정진호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 하계학술대회 논문집 E
    • /
    • pp.2126-2129
    • /
    • 1999
  • We have developed the automatic diagnostic system for power cable insulation using DC voltage decay method in this work. Test condition, test method and diagnose criteria of our diagnostic system are adjustable to a class of power cables such as 3.3, 6.6, 11 and 22kV power cables. We have also developed measurement and diagnostic programs for win95 which is suitable for the management of database such as test condition, diagnose results and cable operation data.

  • PDF

Electra-Optic and Ionic Properties of Twisted Nematic Cells With Different Chiral Pitch

  • Kim, Sung-Woon;Park, Hee-Do;Kim, Hee-Cheol;Park, Young-Il;Suh, Dong-Hae;Lee, Won-Geon;Park, Hae-Sung
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2002년도 International Meeting on Information Display
    • /
    • pp.504-507
    • /
    • 2002
  • We investigated electro-optic and ionic properties of twisted nematic cells by using control of chiral pitch. These properties are observed in practical experiment and simulations. C-V and V-T curve characteristics were obtained from three types of cells with d/p. It is shown that d/p ratio of short cells exhibit faster response time improved by 20% than normal cell. Also, inter-gray response time is improved each rise time and decay time. And, the increase of saturation voltage is happened because of the small twist angel change from initial state at high voltage near 5V. To compensate for longer black level tail, gamma curve index was varied from g = 2.2 to g = 2.7 in module status. Additionally, adding chiral dopant into TN cells improved ionic characteristics such as increasing VHR, Ion density and DC Hysteresis were decreased..

  • PDF