• Title/Summary/Keyword: DC voltage decay

Search Result 8, Processing Time 0.027 seconds

Field Application of Power Cable Diagnosis System (전력케이블 열화진단기법의 현장적용)

  • Kim, Ju-Yong;Han, Jae-Hong;Song, Il-Keun;Kim, Sang-Jun;Lee, Jae-Bong;Oh, Jae-Hyung
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2002.05c
    • /
    • pp.148-151
    • /
    • 2002
  • In order to prevent the failures of underground distribution power cables we need to measure insulation condition in the field. Until now we used DC high voltage as a power source for the cable diagnosis but it was not proper method to the XLPE insulation cables because DC high voltage can affect sound insulation and can't diagnose exactly insulation degradation. For these reasons we imported isothermal relaxation current measurement system called by KDA-1 from germany but it's reliability did not proved in our URD cables. DC voltage decay measurement system was developed by domestic company but they don't have field experience. In this paper we tried to prove reliability of these two systems in the field. Through the field diagnosis and Ac breakdown test the two systems showed similar results.

  • PDF

Insulation Diagnostics of Power Cables and Application to Real Distribution System (케이블 절연열화진단과 실 계통 적용)

  • Yi, Dong-Young;Kim, Ju-Yong;Song, Il-Keun
    • Proceedings of the KIEE Conference
    • /
    • 1999.07d
    • /
    • pp.1569-1571
    • /
    • 1999
  • In this work, we have performed the application experiment for real distribution line to diagnose the underground power cables using DC voltage decay measurement system. We have also performed the Isothermal Relaxation Current test for the same distribution line using KDA-l. We could confirmed possibility of grading the insulation aging state of underground power cables. Therefore, we conclude that it is possible to apply DC voltage decay method to the real distribution line.

  • PDF

A Study on Characteristics of a Volatage-Applied Electrostatic Reducer (전압인가식 제전기의 특성에 관한 연구)

  • 이동훈;정용철
    • Journal of the Korean Society of Safety
    • /
    • v.10 no.2
    • /
    • pp.77-83
    • /
    • 1995
  • An electrostatic reducer of a multi-pole high DC voltage applied type and a high frequency square wave voltage applied type have been studied to eliminate effectively and safely electrostatic charge on a dummy charged material. As a fundamental experiments, measurement were made on the decay time as a function of distance between electrostatic reducer and charged body, skewed angle of electrostatic reducer installed and wind speed of generated ions(+ or -) by electrostatic reducer with high DC voltage and high frequency square wave voltage. Based oil the results above, a appropriate installation and method were produced as a trial for factory.

  • PDF

Diagnostics of Power Cables using DC Voltage Decay method (직류전압감쇄법을 이용한 전력케이블의 절연열화진단)

  • Yi, Dong-Young;Kim, Sang-Joan;Kim, Ju-Yong;Song, Il-Keun
    • Proceedings of the KIEE Conference
    • /
    • 1997.07e
    • /
    • pp.1688-1691
    • /
    • 1997
  • In this work, we have developed the off-line diagnostic system for power cable insulation using DC voltage decay method to diagnose the insulation degradation of underground power cables. Measurement errors of diagnostic system are less than 1% for $1T{\Omega}$ internal resistor. We have also developed measurement and diagnostic programs for win95 which is suitable for the database construction and the management of data. We could conclude that it is possible to apply this system to the multi-grounded underground cable systems.

  • PDF

A DFT Based Filtering Technique to Eliminate Decaying dc and Harmonics for Power System Phasor Estimation

  • Oh Yong- Taek;Balamourougan V.;Sidhu T.S.
    • KIEE International Transactions on Power Engineering
    • /
    • v.5A no.2
    • /
    • pp.138-143
    • /
    • 2005
  • During faults, the voltage and current signals available to the relay are affected by the decaying dc component and harmonics. In order to make appropriate and accurate decisions, most of the relaying algorithms require the fundamental frequency phasor information that is immune to decaying dc effect and harmonics. The conventional Fourier ph as or estimation algorithm is affected by the presence of decaying-exponential transients in the fault signal. This paper presents a modified Fourier algorithm, which effectively eliminates the decaying dc component and the harmonics present in the fault signal. The decaying dc parameters are estimated by means of an out-of-band filtering technique. The decaying dc offset and harmonics are removed by means of a simple computational procedure that involves the design of two sets of Orthogonal digital OFT filters tuned at different frequencies and by creating three off-line look-up tables. The technique was tested for different decay rates of the decaying dc component. It was also compared with the conventional mimic plus the full cycle OFT algorithm. The results indicate that the proposed technique has a faster convergence to the desired value compared to the conventional mimic plus OFT algorithms over a wide range of decay rates. In all cases, the convergence to the desired value was achieved within one cycle of the power system frequency.

A sensorless speed control of brushless DC motor by using direct torque control (직접토크제어에 의한 브러시리스 직류전동기의 센서리스 속도제어)

  • Yoon, Kyoung-Kuk;Oh, Sae-Gin;Kim, Deok-Ki
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.39 no.9
    • /
    • pp.935-939
    • /
    • 2015
  • This paper describes sensorless speed control of brushless DC motors by using direct torque control. Direct torque control offers fast torque response, robust specification of parameter changes, and lower hardware and processing costs compared to vector-controlled drives. In this paper, the current error compensation method is applied to the sensorless speed control of a brushless DC motor. Through this control technique, the controlled stator voltage is applied to the brushless DC motor such that the error between the stator currents in the mathematical model and the actual motor can be forced to decay to zero as time proceeds, and therefore, the motor speed approaches the setting value. This paper discusses the composition of the controller, which can carry out robust speed control without any proportional-integral (PI) controllers. The simulation results show that the control system has good dynamic speed and load responses at wide ranges of speed.

Development of Power Cable Diagnostic and Insulation Measurement System (전력케이블 열화진단용 측정장치 개발)

  • Yi, Dong-Young;Kwon, Hyuk-Il;Chung, Jin-Ho
    • Proceedings of the KIEE Conference
    • /
    • 1999.07e
    • /
    • pp.2126-2129
    • /
    • 1999
  • We have developed the automatic diagnostic system for power cable insulation using DC voltage decay method in this work. Test condition, test method and diagnose criteria of our diagnostic system are adjustable to a class of power cables such as 3.3, 6.6, 11 and 22kV power cables. We have also developed measurement and diagnostic programs for win95 which is suitable for the management of database such as test condition, diagnose results and cable operation data.

  • PDF

Electra-Optic and Ionic Properties of Twisted Nematic Cells With Different Chiral Pitch

  • Kim, Sung-Woon;Park, Hee-Do;Kim, Hee-Cheol;Park, Young-Il;Suh, Dong-Hae;Lee, Won-Geon;Park, Hae-Sung
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2002.08a
    • /
    • pp.504-507
    • /
    • 2002
  • We investigated electro-optic and ionic properties of twisted nematic cells by using control of chiral pitch. These properties are observed in practical experiment and simulations. C-V and V-T curve characteristics were obtained from three types of cells with d/p. It is shown that d/p ratio of short cells exhibit faster response time improved by 20% than normal cell. Also, inter-gray response time is improved each rise time and decay time. And, the increase of saturation voltage is happened because of the small twist angel change from initial state at high voltage near 5V. To compensate for longer black level tail, gamma curve index was varied from g = 2.2 to g = 2.7 in module status. Additionally, adding chiral dopant into TN cells improved ionic characteristics such as increasing VHR, Ion density and DC Hysteresis were decreased..

  • PDF