• Title/Summary/Keyword: DC power transmission

Search Result 293, Processing Time 0.034 seconds

Apparent Viscosity Properties of Electro-Rheological Fluid by Using Rotational Viscometer (회전식 점도계를 이용한 ERF의 겉보기 점도 특성)

  • 장성철;이진우;김태형;박종근
    • Proceedings of the Korea Committee for Ocean Resources and Engineering Conference
    • /
    • 2001.05a
    • /
    • pp.196-201
    • /
    • 2001
  • Electro-Rheological(ER) fluids change their apparent viscosity according to the electric field strength. Therefore, there are many practical applications using the ER fluids. ER effect on the dispersive system of polarizable fine powder/dielectric oil has been investigated. The electrical and rheological properties of starch based ER fluid were reported. Yield stress of the fluids were measured on the couette cell type rheometer as a function of electric fields, particle concetrations, and temperatures. The electric field is applied by high voltage DC power supply, The outer cup is connected to positive electrode(+) and the bob becomes ground(-). And the temperatures the viscosity(or shear stress) versus shear rates were measured. In this experiment shear rates were increased from 0 to 200s$^{-1}$ in 2 minutes. This thesis presents Bingham properties of ER fluids subjected to temperature variations. The temperature dependence of the viscosity was determined for ER fluids consisting of 35 weight % starch particles in automatic transmission oil.

  • PDF

Design and implementation of dual band power amplifier for 800MHz CDMA and PCS handset (CDMA방식의 이중대역 전력증폭기의 설계 및 제작)

  • 윤기호;유태훈;유재호;박한규
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.22 no.12
    • /
    • pp.2674-2685
    • /
    • 1997
  • In this paper, the design and imprlementation of dual-band power amplifier which is used as a critical part for mobile phone to be simultaneously working at a dual band, 800MHz CDAM and PCS frequency band is described. DC operating point of power FET is limited to Class-B to enable long talk time considering that the tyupical power range of CDMA phones in working is around 10 to Class-B to enable long talk time considering that the typical power range of CDMA phones in working is around 10 to 15dBm, i.e., liner range. The power amplifier which employs two GaAs FETs with good linerity at a low operating point has duplexer cuplexer circuit to separate two frequency bands at input and output stage. Electromagnetic analysis for via holes and coupling between narrow transmission lines is included to design a circuit. Moduld size of 0.96CC($22{\times}14.5{\times}3mm^3$) and maximum module current of 130mA at output power range, 10 to 15dBm are attained. The power amplifer module has achieved ACPR performance with 2 to 3dB marging from IS-95 requirement at output powers, 23.5dBm for PCS and 28dBm for 800MHz CDMA respectively.

  • PDF

A Study on the Automation of MVDC System-Linked Digital Substation (MVDC 시스템연계 디지털변전소 자동화 연구)

  • Jang, Soon Ho;Koo, Ja Ik;Mun, Cho Rong
    • KIPS Transactions on Computer and Communication Systems
    • /
    • v.10 no.7
    • /
    • pp.199-204
    • /
    • 2021
  • Digital substation refers to a substation that digitizes functions and communication methods of power facilities such as monitoring, measuring, control, protection, and operation based on IEC 61850, an international standard for the purpose of intelligent power grids. Based on the intelligent operating system, efficient monitoring and control of power facilities is possible, and automatic recovery function and remote control are possible in the event of an accident, enabling rapid power failure recovery. With the development of digital technology and the expansion of the introduction of eco-friendly renewable energy and electric vehicles, the spread of direct current distribution systems is expected to expand. MVDC is a system that utilizes direct current lines with voltage levels and transmission capacities between HVDCs applied to conventional transmission systems and LVDCs from consumers. Converting existing lines in substations, where most power equipment is alternating current centric, to direct current lines will reduce transmission losses and ensure greater current capacity. The process bus of a digital substation is a communication network consisting of communication equipment such as Ethernet switches that connect installed devices between bay level and process level. For MVDC linkage to existing digital substations, the process level was divided into two buses: AC and DC, and a system that can be comprehensively managed in conjunction with diagnostic IEDs as well as surveillance and control was proposed.

High Speed InP HBT Driver Ie For Laser Modulation

  • Sung Jung Hoon;Burm Jin Wook
    • Proceedings of the IEEK Conference
    • /
    • 2004.08c
    • /
    • pp.883-884
    • /
    • 2004
  • High-speed IC for time-division multiplexing (TDM) optical transmission systems have been designed and fabricated by using InP heterojunction-bipolar-transistor (HBT) technology. The driver IC was developed for driving external modulators, featuring differential outputs and the operation speed up to 10 Gbps with an output voltage swing of 1.3 Vpp at each output which was the limit of the measurement. Because -3 dB frequency was 20GHz, this circuit will be operated up to 20Gbps. 1.3Vpp differential output was achieved by switching 50 mA into a 50 $\Omega$ load. The power dissipation of the driver IC was 1W using a single supply voltage of -3.5Y. Input md output return loss of the IC were better than 10 dB and 15 dB, respectively, from DC to 20GHz. The chip size of fabricated IC was $1.7{\Box}1.2 mm^{2}$.

  • PDF

An Algorithm for Generator Maintenance Scheduling Considering Transmission System (송전계통을 고려한 계통운용자의 발전기 예방정비계획 알고리즘에 관한 연구)

  • Han Seok-Man;Shin Young-Gyun;Kim Balho
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.54 no.7
    • /
    • pp.352-357
    • /
    • 2005
  • In competitive electricity markets, the System Operator (SO) coordinates the overall maintenance schedules when the collective maintenance schedule reported to 50 by Gencos not satisfy the specified operating criteria, such as system reliability or supply adequacy. This paper presented a method that divides generator maintenance scheduling of the 50 into a master-problem and a sub-problem. Master-problem is schedule coordination and sub-problem is DC-optimal power flow. If sub-problem is infeasible, we use the algorithm of modifying operating criteria of master-problem. And, the 50 should use the open information only, because the information such as cost function of a generator and bidding Price is highly crucial for the strategies of profit maximization.

A Fault Location Algorithm for a Transmission Line Using Travelling Waves (진행파를 이용한 송전선로의 고장점 표정 알고리즘)

  • Kang Sang-Hee;Kim Jin-Han
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.53 no.10
    • /
    • pp.542-549
    • /
    • 2004
  • The conventional fault location algorithms based on the travelling waves have an inherent problem. In cases of the close-up faults occurring near the relaying point and of the faults having zero degree inception angle of voltage signals, the conventional algorithms can not estimate an accurate fault distance. It is because the shapes of travelling waves are near sinusoidal in those cases. A new method solving this problem is presented in this paper. An FIR(Finite Impulse response) filter which makes high frequency components prominent and makes the power frequency component and dc-offset attenuated is used. With this method, the cross-correlation peak is to be very clear when a close-up fault or a fault having near zero-degree inception angle occurs. The cross-correlation peaks can be clearly distinguished and accurate fault location is practically possible consequently. A series of simulation studies using EMTP(Electromagnetic Transients Program) show that the proposed algorithm can calculate an accurate fault distance having maximum 2% or less error.

A Novel UPFC for Power Transmission System without Series Injection Transformers (송전계통에 적용 가능한 직렬주입변압기가 없는 새로운 UPFC)

  • Han, B.M.;Baek, S.T.;Lee, K.B.
    • Proceedings of the KIEE Conference
    • /
    • 2002.11b
    • /
    • pp.32-34
    • /
    • 2002
  • 본 논문에서는 직렬주업변압기가 없는 새로운 UPFC의 시뮬레이션모형을 개발하고 그 특성을 분석한 내용에 대해 기술하고 있다 송전계통에 적용 가능한 UPFC의 새로운 토폴로지를 제안하고 상세모델을 통하여 계통의 전력조류제어 및 과도상태시의 동특성을 시뮬레이션 한다. 전력시스템의 과도상태 및 제어에 대한 시간영역 시뮬레이션 프로그램인 EMTDC (Electro-Magnetic Transients in DC system)를 사용하여 계통의 전력조류제어인 유효전력과 무효전력의 제어를 수행하고 병렬측의 모선단 입력전압의 크기를 제어한다. 시뮬레이션 결과를 통하여 UPFC 상세모델의 제어성능을 검증한다.

  • PDF

Multi-Gbit/s Digital I/O Interface Based on RF-Modulation and Capacitive Coupling

  • Shin, Hyunchol
    • Journal of electromagnetic engineering and science
    • /
    • v.4 no.2
    • /
    • pp.56-62
    • /
    • 2004
  • We present a multi-Gbit/s digital I/O interface based on RF-modulation and capacitive-coupling over an impedance matched transmission line. The RF-interconnect(RFI) can greatly reduce the digital switching noise and eliminate the dc power dissipation over the channel. It also enables reduced signal amplitude(as low as 200 ㎷) with enhanced data rate and affordable circuit overhead. This paper addresses the system advantages and implementation issues of RFI. A prototype on-chip RFI transceiver is implemented in 0.18-${\mu}{\textrm}{m}$ CMOS. It demonstrates a maximum data rate of 2.2 Gbit/s via 10.5-㎓ RF-modulation. The RFI can be very instrumental for future high-speed inter- and intra-ULSI data links.

The Interference Measurement Analysis between 3.412 GHz Band Broadcasting System and UWB Wireless Communication System

  • Song Hong-Jong;Kim Dong-Ku
    • Journal of electromagnetic engineering and science
    • /
    • v.6 no.1
    • /
    • pp.76-81
    • /
    • 2006
  • Ultra wideband(UWB) technologies have been developed to exploit a new spectrum resource in substances and to realize ultra-high-speed communication, high precision geo-location, and other applications. The energy of UWB signal is extremely spread from near DC to a few GHz. This means that the interference between conventional narrowband systems and UWB systems is inevitable. However, the interference effects had not previously been studied from UWB wireless systems to conventional wireless systems sharing the frequency bands such as Broadcasting system. This paper experimentally evaluates the interference from two kinds of UWB sources, namely a orthogonal frequency division Multiplex UWB source and an impulse radio UWB source, to a Broadcasting transmission system. The receive power degradations of broadcasting system are presented. From these experimental results, we show that in all practical cases UWB system can coexist 35 m distance in-band broadcasting network.

The development of 60MW HVDC System Design (60MW급 HVDC 시스템 설계 기술 개발)

  • LEE, UK-HWA;CHUNG, YOUNG-HO;SHIM, J.W.;MOON, H.B.
    • Proceedings of the KIPE Conference
    • /
    • 2012.07a
    • /
    • pp.301-302
    • /
    • 2012
  • 국내에서 HVDC (High Voltage DC transmission System) 관련 기술은 한국전력공사 및 전력연구원 중심으로 제주와 해남간 설치된 HVDC시스템의 설치 및 운영 기술에 많이 국한되어 왔었다. 그러나 기술을 바탕으로 2010년부터 민간기업인 LS산전과 한국전력공사의 공동 개발을 통하여 60MW ${\pm}80kV$급 전류형 HVDC시스템 설계 및 제작을 추진하여 시스템 설계, 기기 설계 사양, 제작사양서 등의 설계 핵심 기술을 상당부분 확보하는 계기가 되었다. 현재 설계된 Pilot HVDC 시스템은 제작 완료되었고, 제주 실증단지에 설치 및 시험 중에 있으며 2012년 내에 실증운전을 통해서 최종적으로 시스템 설계 기술을 검증할 계획이다. 이 같은 연구를 통하여 상당부분 HVDC 시스템에 대한 독자적인 설계 능력을 갖추게 될 것이다.

  • PDF