• 제목/요약/키워드: DC line voltage

검색결과 409건 처리시간 0.028초

Initial Firing Angle Control of Parallel Multi-Pulse Thyristor Dual Converter for Urban Railway Power Substations

  • Kim, Sung-An;Han, Sung-Wo;Cho, Yun-Hyun
    • Journal of Electrical Engineering and Technology
    • /
    • 제12권2호
    • /
    • pp.674-682
    • /
    • 2017
  • This paper presents an optimal initial firing angle control based on the energy consumption and regenerative energy of a parallel multi-pulse thyristor dual converter for urban railway power substations. To prevent short circuiting the thyristor dual converter, a hysteresis band for maintaining a zero-current discontinuous section (ZCDS) is essential during mode changes. During conversion from the ZCDS to forward or reverse mode, the DC trolley voltage can be stabilized by selecting the optimal initial firing angle without an overshoot and slow response. However, the optimal initial firing angle is different depending on the line impedance of each converter. Therefore, the control algorithm for tracking the optimal initial firing angle is proposed to eliminate the overshoot and slow response of DC trolley voltage. Simulations and experiments show that the proposed algorithm yields the fastest DC voltage control performance in the transient state by tracking the optimal firing angle.

MMC VSC 기반 Point-to-Point HVDC Grid에서의 DC 고장 분석 (DC Fault Study in Point-to-Point HVDC Grid based on MMC VSC)

  • 이동수;김기석;장길수
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2015년도 제46회 하계학술대회
    • /
    • pp.161-162
    • /
    • 2015
  • 최근 세계적으로 전력계통의 대륙 간 연계나 신재생에너지, 분산전원의 계통 연계를 위해 HVDC(High voltage Direct Current)에 대한 연구가 활발히 진행되고 있다. 대용량, 장거리 송전이 필요한 경우 HVAC에서의 전력손실과 송전거리의 한계를 극복하기 위하여 HVDC가 새로운 대안으로 떠오르고 있으며, LCC(Line commutated Converter)와 VSC(Voltage Source Converter)의 기술발전이 비약적으로 이뤄지고 있다. 특히, DC Grid화를 위해서 유럽에서는 해상풍력을 연계한 Windfarm을 DC Grid화 하는 프로젝트가 활발히 진행되고 있다. 이러한 신재생 에너지의 계통 연계를 위해서 DC Grid가 본격적으로 논의가 되고 있고 관련분야에서는 기술개발을 앞다퉈 진행하고 있는 상황이다. DC Grid 구현을 위해 VSC HVDC가 최근 주목받고 있으며, VSC로 연계된 DC Grid의 AC 계통과의 연계를 위해 가장 필요한 것이 바로 DC 차단기라고 할 수 있겠다. 본 논문에서는 DC Grid의 고장분석을 위한 기초연구로써 MMC(Modular Multilevel Converter) VSC를 기반으로 한 Point-to-Point HVDC Grid에서의 DC 고장에 대한 분석을 실시하였으며 그 특징을 분석하였다.

  • PDF

입력전압 파형 검출만으로 구성된 단상 PFC 정류회로 (single-phase PFC rectifier circuit consonant to Input voltage waveform detection)

  • 정상화;이현우;전중함;서기영
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 학술대회 논문집 전문대학교육위원
    • /
    • pp.12-15
    • /
    • 2002
  • This propose a simple DC voltage sensor less single phase PFC(Power Factor Correction Circuit) converter by detecting a AC current sensors are not required to construct the control system. The DC voltage is directly controlled by the command input signal Kd($V_o/V_a$)for the boost chopper circuit. The DC voltage regulation is small because of the feed forward control for the AC line voltage VS and no dependence of the circuit parameters. The sinusoidal current waveform in phase with the AC input voltage can be obtained. These characteristics are confirmed by some experiment results.

  • PDF

고해상도 듀티비 제어가 가능한 디지털 제어 방식의 CMOS 전압 모드 DC-DC 벅 변환기 설계 (Design of digitally controlled CMOS voltage mode DC-DC buck converter for high resolution duty ratio control)

  • 윤광섭;이종환
    • 전기전자학회논문지
    • /
    • 제24권4호
    • /
    • pp.1074-1080
    • /
    • 2020
  • 본 논문은 공정, 전압 및 온도에 둔감하며, 출력전압 상태에 따라 3가지 동작모드가 가능한 디지털 제어 벅 변환기를 제안한다. 기존 디지털 제어 방식의 벅 변환기는 A/D 변환기, 카운터 및 딜레이 라인 회로를 사용하여서 정확한 출력 전압을 제어하였다. 정확한 출력 전압 제어를 위해서는 카운터 및 딜레이 라인 비트 수를 증가시켜서 회로 복잡성 증가 문제점을 지니고 있다. 이러한 회로의 복잡성 문제를 해결하기 위해서 제안된 회로에서는 8비트 및 16 비트 양 방향 쉬프트 레지스터를 사용하고 최대 128비트 해상도까지 듀티비 제어가 가능한 벅 변환기를 제안한다. 제안하는 벅 변환기는 CMOS 180 나노 공정 1-poly 6-metal을 사용하여 설계 및 제작하였으며, 2.7V~3.6V의 입력 전압과 0.9~1.8V의 출력 전압을 생성하고, 리플전압은 30mV, 전력 효율은 최대 92.3%, 과도기 응답속도는 4us이다.

직류 전원선을 이용한 다중 접속 양방향 직렬통신 프로토콜 구현 (Implementation of multiple access bidirectional serial communications protocol using DC power line)

  • 한경호;김원일;황하윤
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2008년도 춘계학술대회 논문집
    • /
    • pp.332-338
    • /
    • 2008
  • This paper handles, implementation of multiple access bidirectional serial communications protocol using two common DC power lines, whict are power supply and ground, connecting multiple devices. Communication between the host and the multiple clients are performed using unique packet data with device ID unique to each devices connected on the common power lines. Host initiates data communications by transmitting command packet to the designated client with the client's ID and the client responds by transmitting response packet to the host and in this way, multiple clients and host exchange the packet through the common power lines. The normal voltage of the power communication line maintains 24V corresponding to level 1 and the host drops the voltage to 12V on sending level 0 signal, also the clients normally keeps the line voltage to 24V use pull-down circuit to drop the voltage to 12V on sending level 1 signal. Power supply originates from the host, the host senses the voltage level of the power communication lines and when the clients activates pull down circuit to send level 0 signal and the voltage drops to 12V, the hosts switches power source from 24V to 12V. Also, when clients deactivate pull down circuit to send level 1 signal, the host senses the voltage increase and switches the power source from 12V to 24V. Experimental circuit is designed with one hosts and four clients and verified the power line voltage switching operation depending on the data signal levels on the power line. The proposed research result can be applied to two wire power communications system with one host and multiple low current consumption clients.

  • PDF

역률개선 위한 자기에어지 궤환기법의 간단한 삼상 단일전력단 AC/DC 컨버터 (A Simple Three-Phase Single-Stage AC/DC Converter with Magnetic Energy Feedback Technique for Power Factor Correction)

  • 문건우;윤석호;윤종수;이기선;추진부
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 1998년도 전력전자학술대회 논문집
    • /
    • pp.438-443
    • /
    • 1998
  • A simple single-stage AC/DC forward converter with transformer magnetic energy feedback technique for power factor correction is proposed. The operational principle of the proposed converter is presented. The proposed converter gives the good power factor correction, low line current harmonic distortions, and tight output voltage regulation. The prototype shows high power factor with low line current harmonics.

  • PDF

Design and Control Method for Sub-module DC Voltage Ripple of HVDC-MMC

  • Gwon, Jin-Su;Park, Jung-Woo;Kang, Dea-Wook;Kim, Sungshin
    • Journal of Electrical Engineering and Technology
    • /
    • 제11권4호
    • /
    • pp.921-930
    • /
    • 2016
  • This paper proposes a design and control method for a high-voltage direction current modular multilevel converter (HVDC-MMC) considering the capacitor voltage ripple of the submodule (SM). The capacitor voltage ripple consists of the line frequency and double-line-frequency components. The double line- frequency component does not fluctuate according to the active power, whereas the line-frequency component is highly influenced by the grid-side voltage and current. If the grid voltage drops, a conventional converter increases the current to maintain the active power. A grid voltage drops, current increment, or both occur with a capacitor voltage ripple higher than the limit value. In order to reliably control an MMC within a limit value, the SM capacitor should be designed on the basis of the capacitor voltage ripple. In this paper, the capacitor voltage ripple according to the grid voltage and current are analyzed, and the proposed control method includes a current limitation method considering the capacitor voltage ripple. The proposed design and control method are verified through simulation using PSCAD/EMTDC.

Sensor Fault Detection, Localization, and System Reconfiguration with a Sliding Mode Observer and Adaptive Threshold of PMSM

  • Abderrezak, Aibeche;Madjid, Kidouche
    • Journal of Power Electronics
    • /
    • 제16권3호
    • /
    • pp.1012-1024
    • /
    • 2016
  • This study deals with an on-line software fault detection, localization, and system reconfiguration method for electrical system drives composed of three-phase AC/DC/AC converters and three-phase permanent magnet synchronous machine (PMSM) drives. Current sensor failure (outage), speed/position sensor loss (disconnection), and damaged DC-link voltage sensor are considered faults. The occurrence of these faults in PMSM drive systems degrades system performance and affects the safety, maintenance, and service continuity of the electrical system drives. The proposed method is based on the monitoring signals of "abc" currents, DC-link voltage, and rotor speed/position using a measurement chain. The listed signals are analyzed and evaluated with the generated residuals and threshold values obtained from a Sliding Mode Current-Speed-DC-link Voltage Observer (SMCSVO) to acquire an on-line fault decision. The novelty of the method is the faults diagnosis algorithm that combines the use of SMCSVO and adaptive thresholds; thus, the number of false alarms is reduced, and the reliability and robustness of the fault detection system are guaranteed. Furthermore, the proposed algorithm's performance is experimentally analyzed and tested in real time using a dSPACE DS 1104 digital signal processor board.

전력선통신을 위한 중 전압용 전력선의 RF채널 특성 (RF Channel Characteristics of the Medium-voltage Power Line for PLC)

  • 김선효;김관호;이형철;신철재
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제51권7호
    • /
    • pp.316-321
    • /
    • 2002
  • In this Paper, the channel characteristics of the medium voltage(22.9kV) power line to analysis the broadband power line communication in the frequency range up to 30MHz was measured. With the sideband electrical coupler in the operating frequency range from DC to 30MHz, we measured characteristic impedance, noise and attenuation of the medium voltage power line, and then characteristic impedance was measured at the state of unloaded medium voltage power line by Scattering parameter method of Vector Network Analyzer. As a measurement result, Channel impedance shows 100~380$\Omega$ at the less than 15MHz and 70~230$\Omega$ at the more than 15 MHz. Noise characteristics of power line shows -75dBm at 20MHz and Narrowband interference noise was from 3 MHz to 7MHz.

PMSM의 퍼지 로직 최적 효율 제어 (A Fuzzy Logical Optimal Efficiency Control of Permanent Magnet Synchronous Motor)

  • 주광성;이동회;안진우
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 춘계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.97-99
    • /
    • 2007
  • This paper presents a fuzzy logical control method to implement an on-line optimum efficiency control for Permanent Magnet Synchronous Motor. This method real-timely adjusts the output voltage of the inverter system to achieve the optimum running efficiency of the whole system. At first, the input power is calculated during the steady state in the process of efficiency optimizing. To exactly estimate the steady state of the system, this section needs check up the speed setting on timely. The second section is to calculate input power of dc-bus. The exact measurement of the voltage and current is the vital point to acquire the input power. The third section is the fuzzy logic control unit, which is the key of the whole drive system. Based on the change of input power of dc-bus and output voltage, the variable of output voltage is gained by the fuzzy logical unit. With the on-line optimizing. the whole system call fulfill the minimum input power of dc-bus on the running state. The experimental result proves that the system applied the adjustable V/f control method and the efficiency-optimizing unit possesses optimum efficiency, and it is a better choice for simple variable speed applications such as fans and pump.

  • PDF